Tender For Construction Of 200 Bedded Boys Hostel For 2Nd Sainik School At Sambalpur, Odisha Buildings.
Tender Value
8.41 Crore
Estimated cost
Bid Submission
28 Sep 2026
5 days left
EMD
8.41 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sambalpur → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 200 Bedded Boys Hostel For 2Nd Sainik School At Sambalpur, Odisha Buildings.
BOQ
| Sl. No. | Item Description |
| 1 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness including cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-charge. |
| 2 | Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge.Upto 1.5 Mtr Depth |
| 3 | From 1.5 Mtr upto 3.0 Mtr Depth |
| 4 | Disposal of building rubbish / malba /rock/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved dumping ground or as approved /directed by Engineer-in-charge, including all lifts involved.etc as per the direction of Engineer-in-charge. |
| 5 | Supplying, diluting and preparing chemical emulsion like CHLORPYRIPHOS or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-constructional anti termite treatment and creating a chemical barrier under and around wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, surrounding the pipes and conduits etc. complete at the rate of 7.5 liters (or as directed by the manufacturer) per sqm on vertical and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center etc.complete as per IS:6313/1981(Part-II) and as per the direction of the Engineer -in-charge including all cost of materials, labour and T&P etc all complete. |
| 6 | Supplying and filling with sand in foundation and plinth in layers not exceeding 20 cm in depth, well watered and compacted , top surface dressed and levelled to proper level and gradient including cost of all materials, conveyance,royalties, loading, unloading, cost of all labour, T&P, etc. all complete as per the direction of Engineer-in-Charge. |
| 7 | Providing and laying Plain Cement Concrete of proportion (1:4:8) using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. |
| 8 | Providing and laying Plain Cement Concrete of proportion (1:3:6) using 40 mm size grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. |
| 9 | Providing and laying Brick masonry work in Foundation & Plinth using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. |
| 10 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.a) Footing |
| 11 | R.C.C. Grade beams |
| 12 | R.C.C. Beams, columns, grider and bressmer etc.Ground Floor |
| 13 | First Floor |
| 14 | Terrace |
| 15 | R.C.C. Floor and Roof slab, landing, balconies up to 4.3Mtr. Height.Ground Floor |
| 16 | First Floor |
| 17 | Terrace |
| 18 | R.C.C. stairs excluding landing but including railing Ground Floor |
| 19 | First Floor |
| 20 | R.C.C. Lintels.Ground Floor |
| 21 | First Floor |
| 22 | Terrace |
| 23 | ChhajasGround Floor |
| 24 | First Floor |
| 25 | Straightening bent up or coiled M.S. rod or HYSD steel (Fe-415 / Fe-500), cutting, bending, cranking, hooking, welding or jointing (if required), the M.S. rod or HYSD steel and binding, tying the grills, hoisting, lowering and placing in proper position as per drawing & design required for R.C.C. works including cost, conveyance and taxes of M.S. rod or HYSD steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc. complete as per approved drawing and technical specification and as per clause-1600 of MoSRTH specification for road & bridge works (Latest Revision ) complete in all respect as directed by Engineer-in-Charge.(weight of binding wires will not be considered for payment and payment will be made on weight of M.S. rod or HYSD steel only. Steel bars of only MAJOR INTEGRATED STEEL PLANTS like SAIL, RINL, TATA, JINDAL & SHYAM STEEL, etc. of Fe-415 / Fe-500 grade are to be used in the work & if required original bill of . steel has to be produced by the contractor)Ground floor |
| 26 | First Floor |
| 27 | Terrace |
| 28 | Fly Ash. brick masonry of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-chargeGround floor |
| 29 | First Floor |
| 30 | Terrace |
| 31 | Fly Ash. brick masonry of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:4) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-chargeGround floor |
| 32 | First Floor |
| 33 | Providing 12mm thick cement plaster in cement mortar (1:6) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.Ground Floor |
| 34 | First Floor |
| 35 | Terrace |
| 36 | Providing 16mm thick cement plaster in cement mortar (1:6) to the surfaces of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading,royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.Ground FLoor |
| 37 | First Floor |
| 38 | Terrace |
| 39 | Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening/ chipping, scraping and cleaning and finishing the plastered surface smooth using wooden floats, bars, etc. only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawing including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.Ground Floor |
| 40 | First Floor |
| 41 | Terrace |
| 42 | Providing average 25mm thick grading Concrete with (1:2:2) using 6mm hard granite chips mixing of water proofing cement compound of approved quality over top of Roof, Terrace, including cost of scaffolding, scraping and cleaning the roof surface, plastering and finishing smooth to proper slope and gradient including cost of all materials, conveyance, taxes and sundries, T&P etc. All complete in all respect as per direction of the Engineer -in-charge. |
| 43 | Providing & installing two component acrylic modified cementitious waterproofing coating with masterseal 551/ Equivalent over roof slab after carrying out pond test on roof slab, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 kg/sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect as per direction of the Engineer -in-charge. |
| 44 | Providing and laying Vitrified Floor Tiles of size 600x600mm confirming to IS : 15622 of of approved make, quality and colour without any warpage,with intermidiate spacers of 4 mm width laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) with intermidiate spacers of 4 mm including cutting to size, laying and filling the joints with epoxy tile grout of approved shade and colour, cleaning the surfaces with oxlaic acid, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.Make: Tiles-Kajaria/ Somany/ Equivalent. Grout-Fosroc/ Kerakoll/ Weber/ Equivalent(Note- Sample of tiles shall be approved before procurement and use.Ground FLoor |
| 45 | First Floor |
| 46 | Providing and laying Vitrified Floor Tiles of size 600x600mm in Dado/Skirting confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance,royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.Ground FLoor |
| 47 | First Floor |
| 48 | Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.Ground Floor |
| 49 | First Floor |
| 50 | Fixing granite tiles of approved dimension area above 0.1 up to 0.4 sqm (10mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.Ground Floor |
| 51 | First Floor |
| 52 | Providing and fixing cement concrete tiles of average 22 mm thick jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).as per the design & drawing with cost of all materials, labour, conveyance, taxes, T&P etc. All complete as per the direction of Engineer -in-charge. |
| 53 | Providing and fixing ISI marked both side laminated flush door shutters with hard wood frame confirming to IS 2202(Part 1) of 34mm thickness with approved colour paint over a coat of primer etc including ISI marked necessary hardware fittings such as, SS Concealed Hinges (6\\"), stopper, Door eye & magnet, SS Tower bolt-8\\", Mortise lock Handle, Cylinder coin & knob key & knob, SS lock body etc. including cost of all labours, materials, conveyance, hardware fixing, loading and unloading and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge. |
| 54 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer using M.S. angles 40x40x6 mm for diagonal braces.etc including cost of all labours, materials, conveyance, hardware fixing,loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge. |
| 55 | Supply and fixing of UPVC Sliding glazed Window made out of hollow multi-chambered uPVC sections having isolated drainage system with the design 3 Track 3 Panel System. The 2 track outer frame of the window having over all size of 98 x 52 mm (with mosquito mesh) having internal wall thickness of 2.50 mm. The glass sashes / shutters shall be made out of Upvc sections with over all size of 42 x 70 mm with internal thickness of 2.50 mm. The mosquito mesh shutter having over all size of 25 x 52 mm with internal wall thickness of 2.50 mm. Reinforcement of galvonised mild steel with thick ness of 1.50 mm has to put through out the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with EPDM gaskit to keep glass tight and unmoved. Single point locking system (called touch lock) made out of casted zamac with white powder coated and locking hook will make of SS 304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon an having capacity of 40 - 120 kg depends on glass weight. Finseal will be provided to protect the dust in between closing point & interlocking point of glass & mesh shutters. The Interlock of the uPVC window should be approved by the Engineer-in- charge before fixing. Glass thickness and colour can be changed as per requirement. |
| 56 | Supply and fixing of uPVC Top Hung glazed uPVC ventilator made out of hollow multi chambered uPVC sections having isolated drainage system with the design Casement (Outside open) The casment frame of the window having over all size of 60 x 52 mm having internal wall thickness of 3.00 mm. The glass panel shall be made out of Upvc sections with over all size of 52 x 78 mm with internal thickness of 3.00 mm. Reinforcement of galvonised mild steel with thickness of 1.20 mm has to put throughout the frame, glass panel. Glass support beading make of upvc sections will be fixed with EPDM gaskit to keep glass tight. Single point locking system (called Cockspur) made out of casted zamac with white powder coated and Friction and Stray Hinges will be made of SS 304 grade material. Multipoint locking system (called Espag) made out of casted zamac with white powder coated can be used if height goes beyond 4.50 feet. The model and brand of the uPvc window shall be approved by the Engineer -in- charge before fixing. Glass thickness and colour will be change as per requirement. |
| 57 | Supplying, Fitting and Fixing M.S works of approved designs made out of M S Flat, hollwo section, i Section, Square bars/ Round bars etc. in railings, grills, gates etc of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming of approved quality metallic primer, making required holes in Masonary Walls / R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Masonary Walls / R.C.C Structures including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, staging, scaffolding, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. |
| 58 | Supplying, fitting and fixing of stainless steel of 304 grade in hand rail using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mt c/c and stainless square pipe bacing of size 32mm x 32mm x 2mm in three rows in staircase as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials, labour T&P etc. required for the complete in all respect as per the direction of Engineer -in- charge. |
| 59 | Providing & Painting with synthetic enamel paint of approved brand and manufacture over a coat of primer to give an even shade as per the including cost of scaffolding staging charges with cost, conveyances, taxes of all materials, cost of labour, T&P required for the work etc. complete for all floors as per specification & direction of the Engineer-in-charge. Ground floor instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete.Ground floor |
| 60 | First Floor |
| 61 | Terrace |
| 62 | Providing and applying 2 coats plastic emulsion paint of approved quality and shade over a coat of wall primer after finishing wall surface of walls with Acrylic wall putty (water based) of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats, providing necessary putty & primer including of all materials, labour, conveyance, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use)Ground FLoor |
| 63 | First Floor |
| 64 | Terrace |
| 65 | Providing and applying two coats of Weather Coat Paint of approved make, quality and shade to the external surface of the building over a coat of primer after finishing wall surface of walls with Acrylic wall putty (water based) of approved make and finished smooth and even surface to receive painting of approved shade and quality after cleaning the plastered surface perfectly by watering and brushing including cost of material, putty, paint, brushes, all labour, taxes, loading, unloading, scaffolding, T&P etc. as required for the work as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use)Ground Floor |
| 66 | First Floor |
| 67 | Terrace |
| 68 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20mm nominal size well rammed ,with side rcc wall and consolidated and grouted with fine sand including finishing the top smooth including watering, curing, cost, conveyance, royalties, taxes of all materials, cost of all labour, T&P etc. complete as required for the finished item of work as directed by the Engineer-in-charge. |
| 69 | ELECTRICAL WORKRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-A |
| 70 | GROUP-B |
| 71 | GROUP-C |
| 72 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 73 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 74 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 75 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)(FLAME retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 76 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (2X1.5+1X1.5) |
| 77 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (2X2.5+1X1.5) |
| 78 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit (2X4+1X1.5) |
| 79 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit . (2X6+1X2.5) |
| 80 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit (4X6+2X4) |
| 81 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 82 | Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 83 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 84 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 85 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 86 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 87 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 88 | Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery greater than or equal to 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. |
| 89 | Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of 2 ftsx2fts CRCA powder coated sheet steel of 25W (595mmx595mmx70mm)and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 90 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 91 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 92 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 93 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 94 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 95 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 96 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD)Warranty on DB is 3 years |
| 97 | Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 1 years. |
| 98 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9./ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 years. |
| 99 | Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years.. |
| 100 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 /ABB FB 200in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 1 years. |
| 101 | Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 1 years. |
| 102 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 1years. |
| 103 | Supplying and fixing 40Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 1years. |
| 104 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 105 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 106 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 107 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade (make-Polycab/ RR/ Finolex/ Havells/ KEI/ Gloster ) of following size cables as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials3.5core x 95 sq mm 2 runs for main |
| 108 | 3.5core x35 sq mm |
| 109 | 4 core x 16 sq mm |
| 110 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 111 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 112 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 113 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 114 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. |
| 115 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 116 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 117 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 118 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 119 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 4 core x16sq mm |
| 120 | 3.5 core x95 sq mm |
| 121 | 3.5 core x35 sq mm |
| 122 | Providing,fixing and laying of following 50mm dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 123 | Providing,fixing and laying of fallowing 200mm dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 124 | S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed.. 2 nos of 3P+N Type 1+2 SPD65kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. |
| 125 | In commer - 200A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Busbar-1&2 04 numbers of 250Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) outgoing - 2 nos 63A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Out going- 08 nos 63A 4P MCB 10kA,C series for power BDB. (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) Out going- 06 nos 40A 4P MCB 10kA,C series for light BDB. (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) Out going- 03 nos 40A 2P MCB 10kA,C series for power BDB. (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 02 set of digital type multifunction meter r(Make-Siemens/Schneider/ABB/Secure) with CT CTs 100/5A 3 nos class 1 type(Make-KAPPA /AE)for voltage,current,frequency,PF,THD indication.Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 126 | Supplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame.(Make:PUMP:KBL/ Grundfos / KSB/ Wilo) |
| 127 | Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge Control panel for fire pumps for auto action.make-Legrand/schneider/Siemens/ABB |
| 128 | 1100 V GRADE POWER/CONTROL CABLES :SITC of FRLS,PVC outer sheateh, steel armoured, aluminium, 1100v grade power cables with glands etc. The minimum size of the cables shall as mentioned below as per direction of engineer in charge.Make-Polycab/Havells/KEI/Finolex/RR Kabel /Gloster 4C x 16 mmsq |
| 129 | 1100 V GRADE POWER/CONTROL CABLES :SITC of FRLS,PVC outer sheateh, steel armoured, aluminium, 1100v grade power cables with glands etc. The minimum size of the cables shall as mentioned below as per direction of engineer in charge.Make-Polycab/Havells/KEI/Finolex/RR Kabel /Gloster .Size-2 C x 1.5 mmsq |
| 130 | Supply,Installation,Testing & Commissioning of 'C' Class heavy duty MS pipe (as per IS 1239 upto 100 mm NB and IS 3589 for above 100 mm 6.33mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size on surface along wall / shaft with MS bracket, suspended from ceiling/ beam with suspenders duly painted with two coats of primer and finished with enamel paint of approved colour laid through pipe or in trench after wrapping with hassen cloth after applying coal tar primer as required as per direction of Engineer-in- charge.Make-TATA/JINDAL/SAIL100mm NB |
| 131 | 80mm NB |
| 132 | Providing, fixing, testing and commissioning of following 100mm NB size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C. Make-Zoloto/AUDCO/Leader |
| 133 | Providing, fitting & fixing of following 100mm NB size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Make-Zoloto/AUDCO/Leader |
| 134 | Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.Make-H.Guru/G.Guru |
| 135 | Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.Make-Danfoss/Indfoss/Grundfoss |
| 136 | Supply,Installation,Testing & Commissioning of stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia hloes with stainless steel flange as required. Make-Zoloto/AUDCO/Leader 100mm NB |
| 137 | Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex |
| 138 | Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge. Make-Minimax/Newage/Fireshield/Safex |
| 139 | Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm intstantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge. Make-Minimax/Newage/Fireshield/Safex |
| 140 | Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge. Make-Minimax/Newage/Fireshield/Safex |
| 141 | Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge. Make-Minimax/Newage/Fireshield/Safex |
| 142 | Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge. |
| 143 | Providing, fitting & fixing of 2-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 150mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Zoloto/Karatr/Kirloskar |
| 144 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories Make-Morley IAS/Siemens/Bosch/Edward/NOTIFIER |
| 145 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories Make-Morley IAS/Siemens/Bosch/Edward/NOTIFIER |
| 146 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket. |
| 147 | SIGNAGES:-Providing and installing in position the following type of sign boards made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over3 mm thick cast acrylic from front side with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, greenish yellow, glow visible upto 4-6 hr in total darkness.Make-Prolite/Bajaj |
| 148 | Illumination Glow light for Exit Indication with Battery Back-up. |
| 149 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent |
| 150 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder. With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent |
| 151 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent |
| 152 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB/Equivalent |
| 153 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn |
| 154 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn |
| 155 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB/Equivalent |
| 156 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB/Equivalent |
| 157 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB/Equivalent |
| 158 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB/Equivalent |
| 159 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent |
| 160 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB/Equivalent |
| 161 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent |
| 162 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB/Equivalent |
| 163 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB/Equivalent |
| 164 | Supply of universal clamp made of SS to connect rod with flat conductor Make-BO/Dehn/ABB/Equivalent |
| 165 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB/Equivalent |
| 166 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB/Equivalent |
| 167 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 168 | Supplying, Erection, Fixing, connection & testing of LED Street light with braket Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 50 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge. |
| 169 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Make- POLYCAB/KEI/HAVELLS /GLOSTER/FINOLEX/RR KABEL |
| 170 | P.H WORKProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25mm dia PVC ASTM pipe (sch-80)Ground Floor |
| 171 | First Floor |
| 172 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.Second Floor32mm dia PVC ASTM pipe (sch-80) |
| 173 | 40mm dia PVC ASTM pipe (sch-80) |
| 174 | 50mm dia PVC ASTM pipe (sch-80) |
| 175 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP angle stop cock(FLR-ACR-5053N) |
| 176 | 15mm dia CP two way bib cock(FLR-CHR-5041N) |
| 177 | 15 mm dia CP S.B. Bib cock(CON-CHR-037KN) |
| 178 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 179 | 20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make) |
| 180 | 15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make) |
| 181 | 25mm dia brass full way valve (Shakti make) |
| 182 | 32mm dia brass full way valve (Shakti make) |
| 183 | 40mm dia brass full way valve (Shakti make) |
| 184 | 50mm dia BFW Valve (Shakti make) |
| 185 | 15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make) |
| 186 | 15mm CP Extension piece |
| 187 | 15mm size C.P. flange |
| 188 | 125mm CP grating |
| 189 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge 2000 liters capacity PVC water storage tank roof of 1st floor |
| 190 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.Ground Floor |
| 191 | First Floor |
| 192 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-chargeGround Floor |
| 193 | First Floor |
| 194 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.Ground Floor |
| 195 | First Floor |
| 196 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Supreme /Ashirvad) |
| 197 | 110mm U-PVC P Trap(Ori Plast/Finolex/Supreme Make) |
| 198 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 199 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 200 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 201 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 202 | 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 203 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 204 | 110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make) |
| 205 | 110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) |
| 206 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 207 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.580mm size Orissa pan (Hindware/Parryware/Neycer make) |
| 208 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
| 209 | Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal |
| 210 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-chargeEuropean water closet with 'p' trap plain(Hindware/Parryware/Neycer make) |
| 211 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Plaza make) with 22inch x 16inch pedestal |
| 212 | Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24inch x 18inch x 10inch sink |
| 213 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail |
| 214 | Towel ring |
| 215 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.600mmx125mm plate glass shelf with CP/NP guard rails. |
| 216 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.600mmx450mm size B.E mirror (swivelled type) |
| 217 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 218 | Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge.½inch x 5inch CP Shower (Plaza Deluxe Make) |
| 219 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 220 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 221 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-chargeInside size 76cmx76cmx46cm with 18inch dia RCC MH cover |
| 222 | Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge |
| 223 | Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site. |
| 224 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 225 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-chargeGround Floor |
| 226 | First Floor |
| 227 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 30cmx30cm special printed series to be pre-approved by the Engineer-in-charge )Ground Floor |
| 228 | First Floor |
| 229 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.Ground Floor |
| 230 | First Floor |
| 231 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 45cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge )Ground Floor |
| 232 | First Floor |
| 233 | Granite Tiles 10mm thick for Sink - Ground Floor |
| 234 | First Floor |
| 235 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 236 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 237 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge100mm dia P.V.C. pipe |
| 238 | 150mm dia P.V.C. pipe |
| 239 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.91 m with 0.45 m (18inch dia RCC Cover ) |
| 240 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 241 | 4 nos 50 Users septic tank of size Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 242 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 243 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. |
| 244 | Supplying all labor T&P &Providing C.C. (1:2:4) with 12mm size broken hard granite chips including watering curing & lead of all materials to site etc. all complete. |
| 245 | Providing C.C. (1:1½:3) with 12mm size hard granite chips of RCC work including hoisting and laying and curing with lead of all materials to site. |
| 246 | Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges. |
| 247 | Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor.RCC floor, roof slab chhaja up to 4.430 m height |
| 248 | Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:3) in foundation and plinth including watering and curing and lead of materials to site. |
| 249 | Supplying all materials labour T&P and providing 12mm thick C.P (1:3) including watering curing and conveyance of all materials to site. |
| 250 | Supplying all materials labour T&P and providing 12mm thick C.P (1:6) including watering curing and conveyance of all materials to site.(out side) |
| 251 | Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site. Same as plaster |
| 252 | Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification. |
| 253 | Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge. |
| 254 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. |
| 255 | 1 no 30,000ltr R.C.C. Sump (6.00x2.50x3.00)Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 256 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 257 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. |
| 258 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge |
| 259 | Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 40mm size crusher broken hard black granite metal including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 260 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 261 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 262 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-chargeRCC floor, roof slab chhaja up to 4.430 m height |
| 263 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 264 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 265 | Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge. |
| 266 | Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge |
| 267 | Construction of 2nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessoriesLabour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 200mm dia bore00 mtr to 30mtr |
| 268 | 30 mtr to 45mtr |
| 269 | Drilling of 150mm dia bore45 mtr to 195.00mtr |
| 270 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.Lowering of 200mm dia P.V.C casing pipes00 mtr to 30 mtrs |
| 271 | 30 mtr to 60mtr |
| 272 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.200mm dia PVC (sch-80) pipe |
| 273 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 274 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
| 275 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: |
| 276 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) |
| 277 | DOL Control panel |
| 278 | 40mm dia steel short piece |
| 279 | Well cap |
| 280 | 50mm size CI bracket |
| 281 | 2.50sqmm flat cable |
| 282 | 20mm dia rigid UPVC pipes |
| 283 | Steel rope with cover |
| 284 | Labour charges for lowering including transportation |
| 285 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.32mm HDPE pipes (Finolex/Supreme make) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysSep 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender