Power Boards / Undertakings / PSU Closing in 5 days TDR #57466642

Tender For For New Connection Work In Full Deposit Item In The Area Of ​​Work Of Electricity Distribution Section Palia

Issued by Boards / Undertakings / PSU · Kheri, Uttar Pradesh
Tender Value
23.60 Lakhs
Estimated cost
Bid Submission
18 Sep 2026
5 days left
EMD
20000
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kheri → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For For New Connection Work In Full Deposit Item In The Area Of ​​Work Of Electricity Distribution Section Palia 1 Safe Loading Carriage & Unloading Of Following Materials From Centre Store, Lakhimpur To Different Work Sites And Its Stacking Distance Approx (0-100) Kms 2 Line Material 3 Pcc Pole 8.5 Mtr.Long 4 Pcc Pole 9.0 Mtr.Long 5 Pcc Pole 11.0 Mtr.Long 6 Stp Pole 11 Mtr. Long 7 T/F 10/16 Kva 8 T/F 25 Kva 9 T/F 63 Kva 10 T/F 100 Kva 11 T/F 250 Kva 12 Acsr Weasel Conductor 13 Acsr Rabbit Conductor 14 Acsr Dog Conductor 15 Lt Abc (1X25+1X16) Sqmm 16 Lt Abc (3X50+1X35+1X16) Sqmm 17 Lt Abc (3X95+1X70+1X16) Sqmm 18 Lt Abc (3X120+1X95+1X16)Sqmm 19 11Kv Xlpe Cable (3X70) Sqmm 20 11Kv Xlpe Cable (3X120) Sqmm 21 11 Kv Pilfer Resistant Material Cubical 22 11 Kv Ct 15/5 Amp 23 Dp Box 1 Phase / 3 Phase 24 Carriging Of 11 Kv Cable Jointing Kit Od And Id 25 Fabrication, Erection Of Sub-Station Type Double Pole On 8.5 Mtr Long Pcc Pole Along With Fixing Of Necessary Hardware Of Double Pole Along With Necessary Pin Insulator As Per Resspo Specification Complete In All Respect. 26 Fabrication, Erection Of Sub-Station Type Double Pole On 9 Mtr Long Pcc Pole Along With Fixing Of Necessary Hardware Of Double Pole Along With Necessary Pin Insulator As Per Resspo Specification Complete In All Respect. 27 Fabrication, Erection Of Sub-Station Type Double Pole On 11 Mtr Long Pcc Pole Along With Fixing Of Necessary Hardware Of Double Pole Along With Necessary Pin Insulator As Per Resspo Specification Complete In All Respect. 28 Fabrication, Erection Of Sub-Station Type Double Pole On 11 Mtr Long St Pole Along With Fixing Of Necessary Hardware Of Double Pole Along With Necessary Pin Insulator As Per Resspo Specification Complete In All Respect. 29 Dragging Of Pcc Pole 8.5 Mtr To Pit Site Digging Of Pit Erection Including Providing All Decentralised Material Required For Completion Of Work . Work Is To Be Carried Out As Per Resspo Specification Complete In All Respect. 30 Dragging Of Pcc Pole 9.0 Mtr To Pit Site Digging Of Pit Erection Including Providing All Decentralised Material Required For Completion Of Work . Work Is To Be Carried Out As Per Resspo Specification Complete In All Respect. 31 Dragging Of St Pole 11 Mtr To Pit Site Digging Of Pit Erection Including Providing All Decentralised Material Required For Completion Of Work . Work Is To Be Carried Out As Per Resspo Specification Complete In All Respect. 32 Grouting Of Pcc/St Pole With Cement, Bricks Ballat And River Sand Ratio 1:4:8 33 Fabrication And Erection T-Off Pole Single Section Pole Alongwith T Off Channel Clamp Disc Fittign And Pin Accessories 34 Providing Nut Bolts Washers Of Different Sizes 35 Ordinary Earthing By Ms Earth Rod 2500Mm Long As Per Resspo Schedule. Only Gi Wire & Earth Rod Shall Be Supplied By The Department 36 Grouting And Nuzzling Of Stay Set Complete Including Its Grouting By Civil Material (Cement, Brick Ballast And River Sand ) Only Stay Set Shall Be Supplied By The Department. 37 Laying And Sagging Of 03 Phase 03 Wire 11Kv Line On Acsr Weasel Conductor As Per Resspo Specification And Direction Of E/I 38 Laying And Sagging Of 03 Phase 03 Wire 11Kv Line On Acsr Rabbit Conductor As Per Resspo Specification And Direction Of E/I 39 Laying And Sagging Of 03 Phase 03 Wire 11Kv Line On Acsr Dog Conductor As Per Resspo Specification And Direction Of E/I 40 Providing And Fixing Of Guarding Angle On Existing 11Kv Support With Clamp And Nut Bolts 41 Laying & Commisioning Of 11 Kv Xlpe Cable (3X70) Sqmm 42 Laying & Commisioning Of 11 Kv Xlpe Cable (3X120) Sqmm 43 Laying Of Cable 11Kv Xlpe Cable (3X70) Sqmm In Pakka Road By Boring Method Laying Cable As Per Resspo Specification & Direction Of E/I 44 Stringing Of Lt Abc (1X25+1X16) Sqmm 45 Stringing Of Lt Abc (3X50+1X35+1X16) Sqmm 46 Stringing Of Lt Abc (3X95+1X70+1X16) Sqmm 47 Stringing Of Lt Abc (3X120+1X95+1X16)Sqmm 48 Hoisting Of 11Kv Xlpe Cable Will Be Passed Through Ms Pipe Of Required Size Duly Clamped With Pole At The Bottom Middle And Top Of The Pole 49 Fixing Of 11 Kv Cable Jointing Kit O/D I/D 50 Construction Of Brick Masonry Plinth Suitable For Installation Of 11Kv Pilfer Metering Cubical Along With Plastering. 51 Dragging Of 11Kv Pilfer Metering Cubical Inside The Metering Room, Its Installation And Commisioning. 52 Cutting And Chopping Of Tree Branches For Clearence Of Ht/Lt Line After Clearance Line Throughout Pieces Of Tree Branches Of Site As And When Required For Completion Of Work. 53 Safe Installation & Energisation Of 16/25/63 Kva T/F On Double Pole By Providing And Fixing Of L Piece Lugs Making Ht/Lt Connection And Its Commisioning Only Transformer Shall Be Supplied By The Deparment. 54 Safe Installation & Energisation Of 250 Kva T/F On Plinth By Providing And Fixing Of L Piece Lugs Making Ht/Lt Connection And Its Commisioning Only Transformer Shall Be Supplied By The Deparment. 55 Fixing Of Well Type Earthing 01 No Nutral Body And 01 No Body Complete In All Respect As Per Resspo Specification. 56 Construction Of Plinth 2 Meter X 2 Meter X 1.5 Meter For 100/250 Kva. Transformer Plinth Wall Shall Be Brick/ Stone Masonry Of 230 Mm Thick, Outside Of The Wall To Be Plastered With 18 Mm Thick Cement Mortar (1:3), Inside Of The Plinth Shall Be Filled With Borrowedsand Duly Compacted R.C.C. Top Slab (1:2:4) Shall Be 75 Mm Thick (Construction Of Plinth Should Comply With Resspo Norms) 57 Poper Wire Mesh Fencing Of Transformer Along Side The Plinth The Height Of The Fence Should Be Feets Above From Ground,Providing Fabrication And Fixing Main Gate In Fromt Of The Plint With Provision For Locking System.Painting Of Entire Metal Works/Main Gate Wire Mesh With Super Enameled Paint In Two Coat Of Red 58 Providing And Fixing Of Dead End Clamp 59 Providing Of Fixing Of Eye Hook 60 Providing Of Fixing Of J- Hook 61 Providing Of Fixing Of Suspension Clamp 62 Providing Of Holding Clamp For Top Dropper T/F 63 Providing Of Holding Clamp For Pcc/Stp Poles 64 Providing Of F Clamp For Pcc /Stp Poles

BOQ

Name of Work:- fo|qr~ forj.k [kaM ify;k ds dk;Z{ks= esa iw.kZ tek en esa uohu la;kstu dk;Z gsrq
Sl. No. Item Description
1SAFE LOADING CARRIAGE & UNLOADING OF FOLLOWING MATERIALS FROM CENTRE STORE, LAKHIMPUR TO DIFFERENT WORK SITES AND ITS STACKING DISTANCE APPROX (0-100) KMS
2LINE MATERIAL
3PCC POLE 8.5 MTR.LONG
4PCC POLE 9.0 MTR.LONG
5PCC POLE 11.0 MTR.LONG
6STP POLE 11 MTR. LONG
7T/F 10/16 KVA
8T/F 25 KVA
9T/F 63 KVA
10T/F 100 KVA
11T/F 250 KVA
12ACSR WEASEL CONDUCTOR
13ACSR RABBIT CONDUCTOR
14ACSR DOG CONDUCTOR
15LT ABC (1X25+1X16) SQMM
16LT ABC (3X50+1X35+1X16) SQMM
17LT ABC (3X95+1X70+1X16) SQMM
18LT ABC (3X120+1X95+1X16)SQMM
1911KV XLPE CABLE (3X70) SQMM
2011KV XLPE CABLE (3X120) SQMM
2111 KV PILFER RESISTANT MATERIAL CUBICAL
2211 KV CT 15/5 AMP
23DP BOX 1 PHASE / 3 PHASE
24CARRIGING OF 11 KV CABLE JOINTING KIT OD AND ID
25FABRICATION, ERECTION OF SUB-STATION TYPE DOUBLE POLE ON 8.5 MTR LONG PCC POLE ALONG WITH FIXING OF NECESSARY HARDWARE OF DOUBLE POLE ALONG WITH NECESSARY PIN INSULATOR AS PER RESSPO SPECIFICATION COMPLETE IN ALL RESPECT.
26FABRICATION, ERECTION OF SUB-STATION TYPE DOUBLE POLE ON 9 MTR LONG PCC POLE ALONG WITH FIXING OF NECESSARY HARDWARE OF DOUBLE POLE ALONG WITH NECESSARY PIN INSULATOR AS PER RESSPO SPECIFICATION COMPLETE IN ALL RESPECT.
27FABRICATION, ERECTION OF SUB-STATION TYPE DOUBLE POLE ON 11 MTR LONG PCC POLE ALONG WITH FIXING OF NECESSARY HARDWARE OF DOUBLE POLE ALONG WITH NECESSARY PIN INSULATOR AS PER RESSPO SPECIFICATION COMPLETE IN ALL RESPECT.
28FABRICATION, ERECTION OF SUB-STATION TYPE DOUBLE POLE ON 11 MTR LONG ST POLE ALONG WITH FIXING OF NECESSARY HARDWARE OF DOUBLE POLE ALONG WITH NECESSARY PIN INSULATOR AS PER RESSPO SPECIFICATION COMPLETE IN ALL RESPECT.
29DRAGGING OF PCC POLE 8.5 MTR TO PIT SITE DIGGING OF PIT ERECTION INCLUDING PROVIDING ALL DECENTRALISED MATERIAL REQUIRED FOR COMPLETION OF WORK . WORK IS TO BE CARRIED OUT AS PER RESSPO SPECIFICATION COMPLETE IN ALL RESPECT.
30DRAGGING OF PCC POLE 9.0 MTR TO PIT SITE DIGGING OF PIT ERECTION INCLUDING PROVIDING ALL DECENTRALISED MATERIAL REQUIRED FOR COMPLETION OF WORK . WORK IS TO BE CARRIED OUT AS PER RESSPO SPECIFICATION COMPLETE IN ALL RESPECT.
31DRAGGING OF ST POLE 11 MTR TO PIT SITE DIGGING OF PIT ERECTION INCLUDING PROVIDING ALL DECENTRALISED MATERIAL REQUIRED FOR COMPLETION OF WORK . WORK IS TO BE CARRIED OUT AS PER RESSPO SPECIFICATION COMPLETE IN ALL RESPECT.
32GROUTING OF PCC/ST POLE WITH CEMENT, BRICKS BALLAT AND RIVER SAND RATIO 1:4:8
33FABRICATION AND ERECTION T-OFF POLE SINGLE SECTION POLE ALONGWITH T OFF CHANNEL CLAMP DISC FITTIGN AND PIN ACCESSORIES
34PROVIDING NUT BOLTS WASHERS OF DIFFERENT SIZES
35ORDINARY EARTHING BY MS EARTH ROD 2500MM LONG AS PER RESSPO SCHEDULE. ONLY GI WIRE & EARTH ROD SHALL BE SUPPLIED BY THE DEPARTMENT
36GROUTING AND NUZZLING OF STAY SET COMPLETE INCLUDING ITS GROUTING BY CIVIL MATERIAL (CEMENT, BRICK BALLAST AND RIVER SAND ) ONLY STAY SET SHALL BE SUPPLIED BY THE DEPARTMENT.
37LAYING AND SAGGING OF 03 PHASE 03 WIRE 11KV LINE ON ACSR WEASEL CONDUCTOR AS PER RESSPO SPECIFICATION AND DIRECTION OF E/I
38LAYING AND SAGGING OF 03 PHASE 03 WIRE 11KV LINE ON ACSR RABBIT CONDUCTOR AS PER RESSPO SPECIFICATION AND DIRECTION OF E/I
39LAYING AND SAGGING OF 03 PHASE 03 WIRE 11KV LINE ON ACSR DOG CONDUCTOR AS PER RESSPO SPECIFICATION AND DIRECTION OF E/I
40PROVIDING AND FIXING OF GUARDING ANGLE ON EXISTING 11KV SUPPORT WITH CLAMP AND NUT BOLTS
41LAYING & COMMISIONING OF 11 KV XLPE CABLE (3X70) SQMM
42LAYING & COMMISIONING OF 11 KV XLPE CABLE (3X120) SQMM
43LAYING OF CABLE 11KV XLPE CABLE (3X70) SQMM IN PAKKA ROAD BY BORING METHOD LAYING CABLE AS PER RESSPO SPECIFICATION & DIRECTION OF E/I
44STRINGING OF LT ABC (1X25+1X16) SQMM
45STRINGING OF LT ABC (3X50+1X35+1X16) SQMM
46STRINGING OF LT ABC (3X95+1X70+1X16) SQMM
47STRINGING OF LT ABC (3X120+1X95+1X16)SQMM
48HOISTING OF 11KV XLPE CABLE WILL BE PASSED THROUGH MS PIPE OF REQUIRED SIZE DULY CLAMPED WITH POLE AT THE BOTTOM MIDDLE AND TOP OF THE POLE
49FIXING OF 11 KV CABLE JOINTING KIT O/D I/D
50CONSTRUCTION OF BRICK MASONRY PLINTH SUITABLE FOR INSTALLATION OF 11KV PILFER METERING CUBICAL ALONG WITH PLASTERING.
51DRAGGING OF 11KV PILFER METERING CUBICAL INSIDE THE METERING ROOM, ITS INSTALLATION AND COMMISIONING.
52CUTTING AND CHOPPING OF TREE BRANCHES FOR CLEARENCE OF HT/LT LINE AFTER CLEARANCE LINE THROUGHOUT PIECES OF TREE BRANCHES OF SITE AS AND WHEN REQUIRED FOR COMPLETION OF WORK.
53SAFE INSTALLATION & ENERGISATION OF 16/25/63 KVA T/F ON DOUBLE POLE BY PROVIDING AND FIXING OF L PIECE LUGS MAKING HT/LT CONNECTION AND ITS COMMISIONING ONLY TRANSFORMER SHALL BE SUPPLIED BY THE DEPARMENT.
54SAFE INSTALLATION & ENERGISATION OF 250 KVA T/F ON PLINTH BY PROVIDING AND FIXING OF L PIECE LUGS MAKING HT/LT CONNECTION AND ITS COMMISIONING ONLY TRANSFORMER SHALL BE SUPPLIED BY THE DEPARMENT.
55FIXING OF WELL TYPE EARTHING 01 NO NUTRAL BODY AND 01 NO BODY COMPLETE IN ALL RESPECT AS PER RESSPO SPECIFICATION.
56CONSTRUCTION OF PLINTH 2 METER X 2 METER X 1.5 METER FOR 100/250 KVA. TRANSFORMER PLINTH WALL SHALL BE BRICK/ STONE MASONRY OF 230 MM THICK, OUTSIDE OF THE WALL TO BE PLASTERED WITH 18 MM THICK CEMENT MORTAR (1:3), INSIDE OF THE PLINTH SHALL BE FILLED WITH BORROWEDSAND DULY COMPACTED R.C.C. TOP SLAB (1:2:4) SHALL BE 75 MM THICK (CONSTRUCTION OF PLINTH SHOULD COMPLY WITH RESSPO NORMS)
57POPER WIRE MESH FENCING OF TRANSFORMER ALONG SIDE THE PLINTH THE HEIGHT OF THE FENCE SHOULD BE FEETS ABOVE FROM GROUND,PROVIDING FABRICATION AND FIXING MAIN GATE IN FROMT OF THE PLINT WITH PROVISION FOR LOCKING SYSTEM.PAINTING OF ENTIRE METAL WORKS/MAIN GATE WIRE MESH WITH SUPER ENAMELED PAINT IN TWO COAT OF RED
58PROVIDING AND FIXING OF DEAD END CLAMP
59PROVIDING OF FIXING OF EYE HOOK
60PROVIDING OF FIXING OF J- HOOK
61PROVIDING OF FIXING OF SUSPENSION CLAMP
62PROVIDING OF HOLDING CLAMP FOR TOP DROPPER T/F
63PROVIDING OF HOLDING CLAMP FOR PCC/STP POLES
64PROVIDING OF F CLAMP FOR PCC /STP POLES
65PROVIDING OF LT INSULATOR FOR PCC /STP POLES
66PROVIDING OF STAY INSULATOR FOR PCC /STP POLES
67PROVIDING OF LT CLAMP FOR PCC /STP POLES
68PROVIDING OF STAY CLAMP FOR PCC /STP POLES
69DRILLING CUTTING AND MAKING OF HOLE.
70उक्त कार्यो के अलावा यदि कोई कार्य पूर्ण करने ने किसी एनी वस्तु उपकरण या कार्य की आवश्यकता होगी टो इन्ही दरो के अन्दर सम्पादित करना होगा
71INCLUDING GST Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57466642
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 23.60 Lakhs
LAST DATE 18-09-2026
Authority
Authority Name Madhyanchal Vidut Vitran Nigam Limited
Work Description Tender For For New Connection Work In Full Deposit Item In The Area Of ​​Work Of Electricity Distribution Section Palia 1 Safe Loading Carriage & Unloading Of Following Materials From Centre Store, Lakhimpur To Different Work Sites And Its Stacking Distance Approx (0-100) Kms 2 Line Material 3 Pcc Pole 8.5 Mtr.Long 4 Pcc Pole 9.0 Mtr.Long 5 Pcc Pole 11.0 Mtr.Long 6 Stp Pole 11 Mtr. Long 7 T/F 10/16 Kva 8 T/F 25 Kva 9 T/F 63 Kva 10 T/F 100 Kva 11 T/F 250 Kva 12 Acsr Weasel Conductor 13 Acsr Rabbit Conductor 14 Acsr Dog Conductor 15 Lt Abc (1X25+1X16) Sqmm 16 Lt Abc (3X50+1X35+1X16) Sqmm 17 Lt Abc (3X95+1X70+1X16) Sqmm 18 Lt Abc (3X120+1X95+1X16)Sqmm 19 11Kv Xlpe Cable (3X70) Sqmm 20 11Kv Xlpe Cable (3X120) Sqmm 21 11 Kv Pilfer Resistant Material Cubical 22 11 Kv Ct 15/5 Amp 23 Dp Box 1 Phase / 3 Phase 24 Carriging Of 11 Kv Cable Jointing Kit Od And Id 25 Fabrication, Erection Of Sub-Station Type Double Pole On 8.5 Mtr Long Pcc Pole Along With Fixing Of Necessary Hardware Of Double Pole Along With Necessary Pin Insulator As Per Resspo Specification Complete In All Respect. 26 Fabrication, Erection Of Sub-Station Type Double Pole On 9 Mtr Long Pcc Pole Along With Fixing Of Necessary Hardware Of Double Pole Along With Necessary Pin Insulator As Per Resspo Specification Complete In All Respect. 27 Fabrication, Erection Of Sub-Station Type Double Pole On 11 Mtr Long Pcc Pole Along With Fixing Of Necessary Hardware Of Double Pole Along With Necessary Pin Insulator As Per Resspo Specification Complete In All Respect. 28 Fabrication, Erection Of Sub-Station Type Double Pole On 11 Mtr Long St Pole Along With Fixing Of Necessary Hardware Of Double Pole Along With Necessary Pin Insulator As Per Resspo Specification Complete In All Respect. 29 Dragging Of Pcc Pole 8.5 Mtr To Pit Site Digging Of Pit Erection Including Providing All Decentralised Material Required For Completion Of Work . Work Is To Be Carried Out As Per Resspo Specification Complete In All Respect. 30 Dragging Of Pcc Pole 9.0 Mtr To Pit Site Digging Of Pit Erection Including Providing All Decentralised Material Required For Completion Of Work . Work Is To Be Carried Out As Per Resspo Specification Complete In All Respect. 31 Dragging Of St Pole 11 Mtr To Pit Site Digging Of Pit Erection Including Providing All Decentralised Material Required For Completion Of Work . Work Is To Be Carried Out As Per Resspo Specification Complete In All Respect. 32 Grouting Of Pcc/St Pole With Cement, Bricks Ballat And River Sand Ratio 1:4:8 33 Fabrication And Erection T-Off Pole Single Section Pole Alongwith T Off Channel Clamp Disc Fittign And Pin Accessories 34 Providing Nut Bolts Washers Of Different Sizes 35 Ordinary Earthing By Ms Earth Rod 2500Mm Long As Per Resspo Schedule. Only Gi Wire & Earth Rod Shall Be Supplied By The Department 36 Grouting And Nuzzling Of Stay Set Complete Including Its Grouting By Civil Material (Cement, Brick Ballast And River Sand ) Only Stay Set Shall Be Supplied By The Department. 37 Laying And Sagging Of 03 Phase 03 Wire 11Kv Line On Acsr Weasel Conductor As Per Resspo Specification And Direction Of E/I 38 Laying And Sagging Of 03 Phase 03 Wire 11Kv Line On Acsr Rabbit Conductor As Per Resspo Specification And Direction Of E/I 39 Laying And Sagging Of 03 Phase 03 Wire 11Kv Line On Acsr Dog Conductor As Per Resspo Specification And Direction Of E/I 40 Providing And Fixing Of Guarding Angle On Existing 11Kv Support With Clamp And Nut Bolts 41 Laying & Commisioning Of 11 Kv Xlpe Cable (3X70) Sqmm 42 Laying & Commisioning Of 11 Kv Xlpe Cable (3X120) Sqmm 43 Laying Of Cable 11Kv Xlpe Cable (3X70) Sqmm In Pakka Road By Boring Method Laying Cable As Per Resspo Specification & Direction Of E/I 44 Stringing Of Lt Abc (1X25+1X16) Sqmm 45 Stringing Of Lt Abc (3X50+1X35+1X16) Sqmm 46 Stringing Of Lt Abc (3X95+1X70+1X16) Sqmm 47 Stringing Of Lt Abc (3X120+1X95+1X16)Sqmm 48 Hoisting Of 11Kv Xlpe Cable Will Be Passed Through Ms Pipe Of Required Size Duly Clamped With Pole At The Bottom Middle And Top Of The Pole 49 Fixing Of 11 Kv Cable Jointing Kit O/D I/D 50 Construction Of Brick Masonry Plinth Suitable For Installation Of 11Kv Pilfer Metering Cubical Along With Plastering. 51 Dragging Of 11Kv Pilfer Metering Cubical Inside The Metering Room, Its Installation And Commisioning. 52 Cutting And Chopping Of Tree Branches For Clearence Of Ht/Lt Line After Clearance Line Throughout Pieces Of Tree Branches Of Site As And When Required For Completion Of Work. 53 Safe Installation & Energisation Of 16/25/63 Kva T/F On Double Pole By Providing And Fixing Of L Piece Lugs Making Ht/Lt Connection And Its Commisioning Only Transformer Shall Be Supplied By The Deparment. 54 Safe Installation & Energisation Of 250 Kva T/F On Plinth By Providing And Fixing Of L Piece Lugs Making Ht/Lt Connection And Its Commisioning Only Transformer Shall Be Supplied By The Deparment. 55 Fixing Of Well Type Earthing 01 No Nutral Body And 01 No Body Complete In All Respect As Per Resspo Specification. 56 Construction Of Plinth 2 Meter X 2 Meter X 1.5 Meter For 100/250 Kva. Transformer Plinth Wall Shall Be Brick/ Stone Masonry Of 230 Mm Thick, Outside Of The Wall To Be Plastered With 18 Mm Thick Cement Mortar (1:3), Inside Of The Plinth Shall Be Filled With Borrowedsand Duly Compacted R.C.C. Top Slab (1:2:4) Shall Be 75 Mm Thick (Construction Of Plinth Should Comply With Resspo Norms) 57 Poper Wire Mesh Fencing Of Transformer Along Side The Plinth The Height Of The Fence Should Be Feets Above From Ground,Providing Fabrication And Fixing Main Gate In Fromt Of The Plint With Provision For Locking System.Painting Of Entire Metal Works/Main Gate Wire Mesh With Super Enameled Paint In Two Coat Of Red 58 Providing And Fixing Of Dead End Clamp 59 Providing Of Fixing Of Eye Hook 60 Providing Of Fixing Of J- Hook 61 Providing Of Fixing Of Suspension Clamp 62 Providing Of Holding Clamp For Top Dropper T/F 63 Providing Of Holding Clamp For Pcc/Stp Poles 64 Providing Of F Clamp For Pcc /Stp Poles
Basic Detail
Tender No 31/EDCG/2026-27
Bidding Type Tender
Location
City Kheri
State Uttar Pradesh
Key Dates
Publish Date 10 Sep 2026
Submission Date 18 Sep 2026
Open Date 18 Sep 2026
Finance
Tender Value 23.60 Lakhs
Tender Fee 3540
EMD 20000
Exemption Available
Document List
BOQ_2227736.xls
ceac8491-251c-4742-9ff9-2793df2c7f53.html
TENDERFOMR31.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2227736.xls

html

ceac8491-251c-4742-9ff9-2793df2c7f53.html

pdf

TENDERFOMR31.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender