Housing Urban and Rular Development Local Bodies Closing in 18 days TDR #57466217

Tender For Proposed Construction Of Multi-Purpose Community Hall, At Chawainamei Khullen Village, Senapati District, Manipur.

Issued by Local Bodies · Kangpokpi, Manipur
Tender Value
2.43 Crore
Estimated cost
Bid Submission
01 Oct 2026
18 days left
EMD
4.86 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kangpokpi → Manipur
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Proposed Construction Of Multi-Purpose Community Hall, At Chawainamei Khullen Village, Senapati District, Manipur.

BOQ

Name of Work:- Proposed Construction of Multi-Purpose Community Hall, at Chawainamei Khullen Village, Senapati District, Manipur.
Sl. No. Item Description
1A:Civil Work
2Sub-Head 1 :-Surface Dressing
3Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead upto 50m and lift upto 1.5m.All kinds of soil.
4Sub-Head 2:-Earth Work
5Earth work in excavation in foundation trenches or drains including dressing of sides ramming of bottoms lift up to 1.5 metres including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres
6Extra for additional lift of 1.5m or part thereof in.All kinds of soil
7Filling available excavated earth (excluding rock) in trenches , plinth side of the foundation etc. in layers not exceeding 20 cm in depth ,consolidating each deposited layer by ramming and watering lead up to 50 metres and lift upto 1.5 metres
8Supply and filling in plinth with sandy soil under floors including watering, ramming consolidating and dressing complete
9Sub-Head 3:-Concrete & RCC Work
10Providing and Laying in position cement concrete of specified grade excluding the cost of centering & shuttering ,1:4:8(1cement:4coarse sand : 8 graded stone aggregate 40 mm nominal size).
11Providing and laying in position ready mixed plain concrete or site batched design mix cement concrete for reinforced cement concrete work,using coarse aggregate and fine aggregate derived from naturalsources,Portland Pozzolana/Ordinary Portland /Portland slag cement,admixture in recommended proportions as per IS:9103 to accelerate / retard setting of concrete , to improve ductility and workability without imparting strength;including pumping of concrete to site laying, curing, carriage for all leads, but excluding the cost of centering, shuttering, finishing and reinforcement as per directionofEngineer-in-charge;for the following grades of concrete:All works upto plinth Level: Concrete of M25 grade with minimum cement content of 330kg/cum
12Providing and laying in position ready mixed plain concrete or site batched design mix cement concrete for reinforced cement concrete work,using coarse aggregate and fine aggregate derived from naturalsources,Portland Pozzolana/Ordinary Portland /Portland slag cement,admixture in recommended proportions as per IS:9103 to accelerate / retard setting of concrete , to improve ductility and workability without imparting strength;including pumping of concrete to site laying, curing, carriage for all leads, but excluding the cost of centering, shuttering, finishing and reinforcement as per directionofEngineer-in-charge;for the following grades of concrete:All works above plinth Level up to Floor V level: Concrete of M25 grade with minimum cement content of 330kg/cum
13Reinforced cement concrete work in beams,suspended floors, roofs having slope upto 15 deg landings, balconies, shelves,chajas, lintels, bands,plain window sills, staircase and spiral staircases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing, and reinforcement with 1:5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregates 20 mm nominal size).
14Providing and laying damp proof course 50 mm thick with concrete cement 1:2:4(1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size)
15Applying a coat of residua lpetroleum bitumen of penetration 80/100 of approved qualit yusing 1.7kg per sqm on damp-proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in Kerosene oil.
16Sub-Head 4:-Reinforcement Steel/ Rebar work
17Steel reinforcement for RCC work i/c straightening , cutting , bending , placing in position and binding all complete upto plinth Level.Thermo Mechanically Treated Bars
18Steel reinforcement for RCC work i/c straightening , cutting , bending , placing in position and binding all complete above plinth Level.Thermo Mechanically Treated Bars
19Sub-Head 5:-Form work
20Foundation, footings, bases of columns etc. for mass concrete.
21Columns, pillars, Piers, Abutments, Posts and Struts.
22Stairs except spiral staircases.
23Suspended floors, roofs, landings, balconies and access platform, with water proof 12mm ply
24Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof 12mm ply
25Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc
26Sub-Head 6:-Brick work
27Brick work with 1st class common burnt clay F.P.S (non modular) bricks in foundation and plinth in:
28Half brick masonry with first class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in Cement mortar 1:4 (1 cement: 4 coarse sand)
29Sub-Head 7:-Wood work / alluminium work
30Providing woodwork in frames of doors, windows, celestory windows and other frames wrought, framed and fixed in position with hold fast lugs or with dash fastner of required dia and length (hold fast lugs or with dash fastner shall be pais separately) with Local best quality Teak
31Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws with Local best quality Teak wood 35mm thick
32Providing and fixing aluminium sliding bolts ISI marked anodised (anodic coating not less than garde AC 10 as per IS 1868) transparent or dyed to required colour or shade with nuts nad screws etc complete with 300x16mm
33Providing and fixing aluminium Tower bolts ISI marked anodised (anodic coating not less than garde AC 10 as per IS 1868) transparent or dyed to required colour or shade with nuts nad screws etc complete with 300x10mm
34Providing and fixing chromium plated Brass handles with necessary screws etc.complete.125mm
35Providing 40x5mm flat iron hold fast 40cm long I/c fixing to framed with 10 mm dia .bolt nuts and windows plugs and wooden plugs and embedding in cement concrete block 30x10x15mm 1:3:6(1cement:3 coarse sand:6 graded stone aggrt.20mm nominal size)
36Providing and fixing aluminium work for doors, windows & ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sectioons of approved make conforming to IS:733 and IS:1285, fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprone gasket etc. Aliminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ panelling, CP brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer in charge.(Glazing and panelling to be paid seperately). Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15)
37Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neprone gasket etc. as per the architectural drawings and the directions of Engineer in charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness.
38Filling the gap in between aluminium frame & adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer in Charge complete. Upto 5 mm depth and 5 mm width
39Sub-Head 8:-Finishing work
4015 mm thick plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 ( 1 cement : 3 fine sand )
4120mm cement plaster of mix 1:4(1 cement:4 fine sand ) .
42Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacture over the plastered wall surface to prepare the surface even and smooth complete.
43Finishing walls with water proofing cement paint of of required shade: New work (two or more coats applied @ 3.84Kg/10sqm)
44Painting with oil type wood preservatives of approved brand and manufacture: New work (two or more coats)
45Polishing on wood work with ready made wax polish of approved brand and manufacture: New work
46Varnishing with varnish of approved brand and manufacturer:Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish.
47Applying one coat of water thinnable cement primer of approved brand and manufacture: Water thinnable cement primer
48Finishing walls with textured exterior paint of required shade:New work(two or more coats [email protected]/1sqm)overandincluding base coat of water proofing cement paint applied @2.2kg/10sqm.
49Wall painting with premium acrylic emulsion pain to interior grade,having VOC(Volatile Organic Compound )conten tless than 50grams/ litre of approved brand and manufacture,including applying additional coats wherever required to achieve even shade and colour. Two coats
50Sub-Head 9:-Flooring work
5162 mm thick concrete flooring with concrete hardener toping under layer 40mm thick cement concrete 1:2:4 (1 cement:2 coarse sand :4 graded stone aggregates of nominal size 20 mm) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix :2 graded stone aggregates 6 mm nominal size ) by volume hardeneing compound is mixed @ 2lit per 50 kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
52Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622,of approved brand and manufacturer,in all colour sandshade,laid on 20mm thick cement mortar1:4(1cement:4coarsesand)joining with grey cement [email protected]/sqm including grouting the joints with white cement and matching pigmentsetc.: Size of tiles 600x600mm
53Marble stone flooring with 18mm thick marble stone(sample of marble shall be approved by Engineer-in-charge)over 20mm(average)thick base of cement mortar1:4(1Cement:4coarsesand)laid and jointed with grey cement slurry including rubbing and polishing complete with: Udaipur green marble
54Extra for prefinished nosing to treads of steps of marble stone
55Tile work in skirting,riser of steps and dado(upto2mheight)over 12mm thick bed of cement mortar1:3(1cement:3coarsesand)andjointed with grey cement [email protected]/sqm including pointing in white cement mixed with pigment of matching shade complete: 8mm thick
56Sub Head 10: Steel work & Accessories
57Providing and fixing stainless steel (Grade304) railing made of Hollow tubes,channels,plates etc,including welding,grinding,buffing,polishing and making curvature (whereever required) and fitting the same with necessary stainless steel nuts and bolt complete,i/c fixing the railing with necessary accessories & stainless steel dash fastners,stainless steel bolts etc,of required size,on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolt, fastners etc)
58P/F M.S. fan clamps type-I or II of 16mm dia. and M.S.bar bent to shape with hooked ends in RCC slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete.
59Providing and fixing in position vertical collapsible steel shutter with vertical channels 20mm x 10mm x 2 mm and braced with flat iron diagonals 20 mm x 5 mm sizes with top and bottom rails of T iron 40 mm x 40 mm x 6 mm with 40 mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers handles including applying a priming coat of Steel primer.
60Sub Head 11: Ceiling work
61Providing and fitting at all height false ceiling including providing and fixing of framework made of specia lsectios ,power pressed from MS sheet and galvanised with zinc coating of 120gms/sqm (both sided inclusive)as perIS:277 and consisting of angle cleats of size 25mm widex1.6 mm thick with flanges of 27 mm and 37mm ,at 1200 mm centre to centre,one flange fixed to the ceiling with dash fastner 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixedto the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required GI channels 45x15x0.9mm running at the spacing of 1200mm c/c,to which the ceiling section 0.5mm thick bottom wedge of 80mm witht appered flanges of 26mm each having clips of 10.5mm at450mm c/c,shall b e fixed in direction perpendicular to GI intermmediate channel with connecting clips made out of2.64mm dia x230 mm long GI wire at every junction,including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long,............
62Steel work in built up tubular (round, square, or rectangular tubes etc) trusses etc, including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc complete with Electric resistance or induction butt welded tubes
63Providing and fixing precoated galvanised iron profile sheets (size, shape, and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120gsm as perIS:277, in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and poluester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desire by Engineer-in-charge. The sheet shall be fixed using self drilling/ self tapping screws of size (5.5+55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with Precoated galvanised iron profile sheets 0.50mm thick/4.2Kg/sqm
64Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS:277 in 240mpa steel grade 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I seam bolts and nuts, GI plain and bitumin washers complete:
65Ridges plain(500-600mm), Precoated galvanished iron profile sheets 0.50mm thick
66Gutter(500-600mm), Precoated galvanished iron profile sheets 0.50mm thick
67B:Internal water supply and saniatary installation
68P/F white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape i/c providing and fixing white vitreous china cistern with dual flush fiiting of flushing capacity 3 lit/6 lit (adjustable to 4 lit/ 8 lit) i/c seat cover and cistern fittings, nuts, bolts and gasket etc. complete
69Providing and fixing wash basin with CI brackets, 15mm dia CP brass pillar taps, 32 mm C.P brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White vitreous china wash basin size 550x400mm with a pair of 15mm CP brass pillar tap.
70Providing and fixing PTMT Waste Coupling for wash basin and sink of approved quality and colour
71Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete.24.37.1 Flexible pipe: 40mm diameter
72Providing and fixing 600 x 450 mm levelled edge mirror of Indian make superior glass (of approved quality) quality complete with asbestos sheet ground, fixed to wooden cleat with C.P. brass screws and washers.
73Providing and fixing PTMT towel rail complete with bracket fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms
74Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings arrangement of approved quality and colour, weighing not less than 105gms
75Providing and fixing CPVC. pipes having thermal stability for hot o& cold water supply ,including all CPVC plain & brass threaded fotting, including fixing the pipe with clamps at 1.00 m spacng.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.
7620 mm diameter
7725 mm diameter
7832 mm diameter
79Providing and fixing CP brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms .15mm nominal bore.
80Providing and fixing of C.P brass stop cock (concealed) of approved quality . 15 mm diameter
81Providing and fixing PTMT pillar cock of approved qualityand colour . 15 mm nominal bore ,98 mm long,weighing not less than 75 gms
82Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but withou fittings and the base support for tank.
83Providing and fixing PTMT extension nipple fro water tank pipe, fittings of approved quality and colour.25 mm nominal bore weighing not less than 62 gms
84Providing and fixing CPVC. pipes having thermal stability for hot o& cold water supply ,including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in charge.
85100 mm nominal outer dia pipes
8680 mm nominal outer dia pipes
87P/F unplasticised PVC connection pipe with PTMT nuts, collar and bush of approved quality and colour
8815 mm nominal bore,with 30 cm length
8915 mm nominal bore,with 45 cm length
90P/F G.I union in G.I pipe i/c cutting and threading the pipe and making long screws etc. complete
9120 mm nominal bore
9225 mm nominal bore
9332 mm nominal bore
94Providing flanged joints to double flanged C.I/D.I pipes and specials, i/c testing of joints
95100 mm dia pipes
96150 mm dia pipes
97P/F C.P brass shower rose with 15 or 20 mm inlet
98150 mm diameter
99Providing and fixing PTMT swivelling shower, 15 mm nominal bore weighing not less than 40 gms
100C:Internal electrification and installation
101Wiring:
102Wiring for light point / fan point / exhaust fan point / call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc. as reqd.
103Group A
104Group B
105Group C
106Wiring for light point / power plug with 2x4mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping along with 1 no. 4mm2 FR PVC insualted copper conductor single core cable for loop earthing etc. as reqd.
107S/F suitable size GI box with modular plate and cover in front on surface /recess i/c P/F 3 pin 5/6 amp socket outlet and 5/6 amp modular switch, connection painting etc. as reqd. (for light plugs to use in non-residential building).
108S/F suitable size GI box with modular plate and cover in front on surface /recess i/c P/F 6 pin 15/16 and 5/6 amp modular socket outlet 15/16 amp modular switch, connection painting etc. as reqd.
109Wiring for circuit / sub-main wiring along with earth wire with (the following sizes of) FR PVC insulated copper conductor single core cable in PVC casing & capping etc. as reqd.
1101. 2x2.5mm2 +1x2.5mm2 earth wire.
1112. 2 x 4mm2 + 1 x 4mm2 earth wire.
1123. 2 x 6mm2 + 1 x 6mm2 earth wire.
113S/D (following size) of FR PVC insulated copper conductor single core cable in existing surface /recessed steel/PVC conduit as reqd.
114a) 2x4mm2
115b) 2x6mm2
116c) 4x6mm2
117Supply for 50mm2 4core PVC/XLPE insulated heavy duty armoured cable 1.1KV grade.
118Accessories:
119S/F 15W Surface mounting LED down light with white powder coated aluminum housing with integrated electronic driver i/c connection as reqd.(HAVELLS)
120S/F 305mm sweep exhaust fan complete with all accessories i/c connection etc. As reqd.
121S/F 450mm sweep fan complete with all accessories i/c connection etc. As reqd.
122Switch Gear:
123S/F (2+8 way) single pole and neutral, prewired, sheet steel, MCB distributon board, 240 V on surface/recessd complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for MCB knobs, detachable gland plate, interconnection, phosphatized and powder painted including earthing etc. as reqd. (but without MCB/RCCB/Isolator).
124S/F 63 amp,double pole, 240 volts, isolator in the existing MCB DB comlete with connections, testing and commissiong etc. as required.
125S/F of metal boxes with phenolic laminated sheet cover in front 250mmx300mmx100mm deep.
126S/F 5amp to 32amp rating 230V 'B' series MCB for lighting and other load of single pole in the existing MCB DB complete with connection testing and commissioning etc. as reqd.
127Earthing Items:
128Earthing with copper earth plate 600mm x 600mm x 6mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe ec. (but without charcoal or coke and salt).
129Extra for using salt & charcoal for copper plate earth electrode as reqd.
130P/L earth connection from earth electrode with 8 SWG dia G.I. wire in 15mm dia G.I. pipe as reqd.
131P/F 8SWG dia GI copper wire on surface or in recessed for loop earthing along with existing surface/ recessed conduit /sub-main wiring /cable as reqd.
132D:Land Development
133Excavation in hilly areas in ordinary rock by mechanical means not requiring blasting.(Excavation in ordinary rock in hilly area by manual means including cutting and trimming of side slopes and disposing of excavated earth with all lifts and lead upto 1000 metres.)
134Supply and filling in plinth with sandy soil under floors including watering, ramming consolidating and dressing complete
135Felling trees of girth including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable materials.
136Beyond 30 cm girth upto and including 60 cm girth
137Beyond 60 cm girth upto and including 120 cm girth
138E:Fire Fighting
139Supplying and fixing of firefighting equiment and material Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57466217
AUTHORITY Local Bodies
TENDER VALUE 2.43 Crore
LAST DATE 01-10-2026
Authority
Authority Name Rural Development And Panchayats Department
Work Description Tender for Proposed Construction Of Multi-Purpose Community Hall, At Chawainamei Khullen Village, Senapati District, Manipur.
Basic Detail
Tender No 7/DRDA(SPT)/CSR/2023/Pt-I(CHK)
Bidding Type Tender
Location
City Kangpokpi
State Manipur
Key Dates
Publish Date 11 Sep 2026
Submission Date 01 Oct 2026
Open Date 03 Oct 2026
Finance
Tender Value 2.43 Crore
Tender Fee 5000
EMD 4.86 Lakhs
Exemption Not Available
Document List
3c5ba458-15ab-4c32-9fe8-cb730ed7b855.html
BOQ_3776.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Oct 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

3c5ba458-15ab-4c32-9fe8-cb730ed7b855.html

xls

BOQ_3776.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders