Communications and Information Technology Government Departments Closing in 16 days TDR #57466146

Tender For Supply Installation Testing and Commissioning of 1X250 Kva Outdoor Transformer Sub Station For O/O Cca Up(E) Te Compound Vikash Khand-I, Gomti Nagar, Lucknow.

Issued by Government Departments · Lucknow, Uttar Pradesh
Tender Value
19.58 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
16 days left
EMD
39178
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of 1X250 Kva Outdoor Transformer Sub Station For O/O Cca Up(E) Te Compound Vikash Khand-I, Gomti Nagar, Lucknow.

BOQ

Name of Work:- SITC of 1x250 KVA outdoor transformer sub station for O/o CCA UP(E) TE compound Vikash Khand-I, Gomti Nagar, Lucknow.
Sl. No. Item Description
1Supplying, installation, testing and commissioning of 250KVA capacity continuous loading BEE 5 Star rated Corresponding Level as per BIS amended upto date of receipt of tender , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN Oil Natural Air Natural copper wound transformer Electrolytic grade 99.9 percentage pure copper, Core made of first grade Cold Rolled Grain Oriented CRGO Core grade MOH or better, suitable for out door applications with Offload Tap Changer on HV side with manual operation complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil , i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS 2026 Part 1 to Part 5, IS 1180 and as per CPWD specifications complete in all respects etc as required at site. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS 1180 Part 3 shall be referred to for paint thickness for normal to medium corrosive atmosphere Fitting and Accessories The following fittings shall be provided , a. Two earthing terminals with the earthing symbol, b. Oil level gauge indicating oil level at minimum, 30degree C and maximum operating temperature, c. Air release device for non sealed type transformers, d. Rating and terminal marking plates, e Silica gel breather f. Drain cum sampling valve ¾ inch nominal size thread, IS 554 preferably steel with plug for three phase transformers, g. Thermometer pocket with cap, h. Oil filling holes having 1.25inch nominal size thread with cover, i. Lifting lugs for the complete transformer as well as for core and winding assembly, j. One filter valve on the upper side of the tank for transformers, k. Unidirectional flat rollers, l. Inspection hole, m. HV side neutral grounding strip where one of the HV bushing terminal is connected to earth , n. Oil temperature indicator and winding temperature indicators for transformers , o. Additional Neutral separately brought out on bushing for earthing. , p. Monogram Plate , q. Inspection cover , r. Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. , s. Necessary hardware, clamps, lugs etc. for termination on HV/MV etc.
2Provisioning of 9 mtr height swaged type steel tubular pole confirming IS 2713, duly pained suitable for 11KV supply complete with MS base plate etc as required
3Erection of steel tubular or rail pole strut in cement concrete 1 retio 3 retio 6, 1 cement: 3 coarse sand 6 graded stone aggregate 40 mm nominal size foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
4Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in a Cement mortar 1 ratio 4, 1 cement 4 coarse sand
5Pdg 15 mm cement plaster on the rough side of single or half brick wall of mix a. 1 ratio 4 , 1 cement 4 fine sand
6Supplying and installaton 300 mm width X 50 mm depth X 1.6 mm thickness of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5 percetage, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts and nuts, painting uspenders, fastener etc as required.
7Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
8Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re filling etc. as required.
9Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
10Supplying and erection of 11 KV triple pole suitable capacity Gang operated air break switch 6 insulator, 3 Pc. set complete with 25 mm dia. 3m long operating pipe, lock and handle etc. as reqd.
11Supplying and erection of two lengths of channel iron 75 mm X 40 mm X 6 mm 7.14 kg per metre double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc as per drawing and painting with primer and finish paint as required.
12Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
13Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
14Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV rms with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
15Pdg/ fixing ABC cable of 11 KV grade with fresh Aerial Bunched power cable ABC Cable of 11 KV grade of size 3 core x 35 Sq. mm. Aluminum conductor Cross Linked Polyethylene Insulated XLPE individual core screened a/w load bearing messenger conductor 25 sq mm , confirming to IEC 60502 part 1 complete with laying as per site requirement ISI.
16Pdg/ fixing 3core 95Sq.mm 11KV grade Aluminium HT Cables, Stranded Compacted Circular Aluminium Conductor, Conductor Screen with Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with Extruded Semi Conducting Compound in Combination with Copper Tape, Cores Laid Up, Innersheath of PVC, Galvanised Steel Flat Strip armoured, and Overall PVC Sheathed Cable Conforming to IS 7098 Part 2 2011 with upto Date Amendments.
17Pdg and fixing 11KV rating heat shrinkable HT cable termination kit suitable of 3core 95 Sq.mm HT cable complete with lugs etc as required M/s Raychem / SS make
18Supply of following size of pvc insulated pvc sheathed 1.1 kv grade Aluminium conductor unarmoured/ armoured cable confirming to relevant IS Specification etc complete as reqd. Make BSNL Approved make. a. 3.5 x 120sqmm armoured
19Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a. 3.5 X 120 sq. mm
20Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size bove 95 sq. mm and upto 185 sq. mm in following manners. a. in the existing RCC/ HUME/ METAL pipe
21b. in the existing masonry open duct
22c. on surface
23d. on cable tray
24Pdg and fixing fencing all around transfomer made out of suitable size MS angle iron, MS flat iron, min 3mm dia wire mesh/ jali with provision of lockable gate with in fencing complete as reqd.
25S/fixing 4.5kg CO2 type fire extinguisher with 1.5mtr hose and horn complete as required. ISI marked
26Pdg 6mtr length B Class 50mm dia GI pipe pole complete with all accessoroies including s/f of socket, suitable size base plate at bottom etc i/c cutting, threading complete as required.
27Erection of metallic pole of following length in cement concrete 1 ratio 3 ratio 6 , 1 cement 3 coarse sand 6 graded stone aggregate 40 mm nominal size foundation including excavation and refilling etc. as required. A. Above 4.5 Meter and upto 6.5 Meter Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57466146
AUTHORITY Government Departments
TENDER VALUE 19.58 Lakhs
LAST DATE 30-09-2026
Authority
Authority Name Bharat Sanchar Nigam Limited
Work Description Tender for Supply Installation Testing and Commissioning of 1X250 Kva Outdoor Transformer Sub Station For O/O Cca Up(E) Te Compound Vikash Khand-I, Gomti Nagar, Lucknow.
Basic Detail
Tender No SEET/LKO/2026-2027 /NIT/18, and GEM BID No. GEM/2026/B/8018280
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 11 Sep 2026
Submission Date 30 Sep 2026
Open Date 01 Oct 2026
Finance
Tender Value 19.58 Lakhs
Tender Fee Ref. Documents
EMD 39178
Exemption Not Available
Document List
56705e96-928e-41dc-b082-667c8140ca73.html
ATCTF1.pdf
BOQ_338970.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Oct 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

56705e96-928e-41dc-b082-667c8140ca73.html

pdf

ATCTF1.pdf

xls

BOQ_338970.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender