Tender For Repair/ Maintenance Of Building Security Light, Eathing, Mccbs/ Mcbs Db Box/ Tpn And Connected Work Of Building At D-Iv And D-V Zone & Mes Office Area Under Age E/M-Ii Of Ge(N) Mamun.
Tender Value
20 Lakhs
Estimated cost
Bid Submission
02 Oct 2026
21 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Building Security Light, Eathing, Mccbs/ Mcbs Db Box/ Tpn And Connected Work Of Building At D-Iv And D-V Zone & Mes Office Area Under Age E/M-Ii Of Ge(N) Mamun.
BOQ
| Sl. No. | Item Description |
| 1 | S&F in replacement SPN MCB DB 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating not less than 100Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket, making good the disturbed surface to match the existing wall by painting and plastering with same colour, complete all as specified and directed. |
| 2 | S&F in replacement Triple pole and neutral DB 4 way sheet metal enclosures double door 415 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating not less than 200Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket making good the disturbed surface to match the existing wall by painting and plastering with same colour, complete all as specified and directed. |
| 3 | S&F in replacement sheet metal enclosures double door VTPN MCB DB 4 way, 415 V AC, 50 Hz AC with 200 amps copper bus bar complete with IP54,IK09 protection suitable for wall including MCCB 160 amps, 4P, 16KA with fixed magnetic and thermal setting of same make as of DB and making good the disturbed surface to match the existing wall by painting and plastering with same colour complete all as specfied and directed. |
| 4 | S&F in replacement MCCB 160 Amps, 4P, 16kA rating as per site requirement, complete all as specified and directed. |
| 5 | S&F in replacement Sub main wiring with two run single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2 x 6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor cable green colour of size 6 sqmm as earth lead in & including concealed rigid medium grade PVC conduit not less than 25mm 1.2mm thick dia ISI marked with all accessories and making good disturbed surface of wall/ floor with cement mortar 1:4 and finishes to match exisiting surface, including taking down old submain wiring, complete all as specified and and directed. |
| 6 | Point wiring using 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.5mm thick and connected to common earth dolly with 1.2mm thick cadmium plated CI/GI pressed steel sunken box and 3mm thick plastic laminated sheet cover fixed with brass screws complete including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. Note :-1. Connections of cable with MCBs/Switch sockets shall be done through proper size copper/ brass thimbles2. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit not feasible.3. Proper colour code will be used for wiring as per the electrical rule and as directed by GE/ Engineer-in-Charge. |
| 7 | Switch piano flush button single pole one way 5/6 Amp 240 volts complete all as specified and as directed. |
| 8 | S&F in replacement MCB, TPN, AC, 415 volts 'C' series capacity of 40-100 Amps, 50 Hz, 10kA and making connections, complete all as specified & directed. |
| 9 | MCB, SPN, AC, 240 volts 'C' series capacity of 32 Amps, 50 Hz, 10kA and making connections, complete all as specified & directed. |
| 10 | MCB, SP, AC, 240 volts 'C' series capacity of 5-32 Amps, 50 Hz, 10kA and making connections, complete all as specified & directed. |
| 11 | Replacement of LED street/ building light fitting 60 watt 230 V AC outdoor type with high pressure die-cast aluminum hosing, PC diffuser, and heat resistant complete with integrated electronic driver with high efficiency including 32mm bore GI pipe bracket mounted on wall or roof using clamps, nuts, bolts, washers, fasteners etc.complete with polycarbonated cover, IP 65/66 protection and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 12 | Earthing complete in repair with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to 4mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009.Note :-1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. 2. On testing after completion if the desired earth resistance is not obtained the earthing will be re-done at no extra cost. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
TodayOct 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysOct 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender