Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #57466102

Tender For Repair/ Maintenance Of Building Security Light, Eathing, Mccbs/ Mcbs Db Box/ Tpn And Connected Work Of Building At D-Iv And D-V Zone & Mes Office Area Under Age E/M-Ii Of Ge(N) Mamun.

Issued by Statutory Bodies & Commissions/Committees · Pathankot, Punjab
Tender Value
20 Lakhs
Estimated cost
Bid Submission
02 Oct 2026
21 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Building Security Light, Eathing, Mccbs/ Mcbs Db Box/ Tpn And Connected Work Of Building At D-Iv And D-V Zone & Mes Office Area Under Age E/M-Ii Of Ge(N) Mamun.

BOQ

Name of Work:- REPAIR/ MAINT OF BUILDING SECURITY LIGHT, EATHING, MCCBs/ MCBs DB BOX/ TPN AND CONNECTED WORK OF BUILDING AT D-IV AND D-V ZONE & MES OFFICE AREA UNDER AGE E/M-II OF GE(N) MAMUN.
Sl. No. Item Description
1S&F in replacement SPN MCB DB 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating not less than 100Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket, making good the disturbed surface to match the existing wall by painting and plastering with same colour, complete all as specified and directed.
2S&F in replacement Triple pole and neutral DB 4 way sheet metal enclosures double door 415 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating not less than 200Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket making good the disturbed surface to match the existing wall by painting and plastering with same colour, complete all as specified and directed.
3S&F in replacement sheet metal enclosures double door VTPN MCB DB 4 way, 415 V AC, 50 Hz AC with 200 amps copper bus bar complete with IP54,IK09 protection suitable for wall including MCCB 160 amps, 4P, 16KA with fixed magnetic and thermal setting of same make as of DB and making good the disturbed surface to match the existing wall by painting and plastering with same colour complete all as specfied and directed.
4S&F in replacement MCCB 160 Amps, 4P, 16kA rating as per site requirement, complete all as specified and directed.
5S&F in replacement Sub main wiring with two run single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2 x 6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor cable green colour of size 6 sqmm as earth lead in & including concealed rigid medium grade PVC conduit not less than 25mm 1.2mm thick dia ISI marked with all accessories and making good disturbed surface of wall/ floor with cement mortar 1:4 and finishes to match exisiting surface, including taking down old submain wiring, complete all as specified and and directed.
6Point wiring using 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.5mm thick and connected to common earth dolly with 1.2mm thick cadmium plated CI/GI pressed steel sunken box and 3mm thick plastic laminated sheet cover fixed with brass screws complete including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. Note :-1. Connections of cable with MCBs/Switch sockets shall be done through proper size copper/ brass thimbles2. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit not feasible.3. Proper colour code will be used for wiring as per the electrical rule and as directed by GE/ Engineer-in-Charge.
7Switch piano flush button single pole one way 5/6 Amp 240 volts complete all as specified and as directed.
8S&F in replacement MCB, TPN, AC, 415 volts 'C' series capacity of 40-100 Amps, 50 Hz, 10kA and making connections, complete all as specified & directed.
9MCB, SPN, AC, 240 volts 'C' series capacity of 32 Amps, 50 Hz, 10kA and making connections, complete all as specified & directed.
10MCB, SP, AC, 240 volts 'C' series capacity of 5-32 Amps, 50 Hz, 10kA and making connections, complete all as specified & directed.
11Replacement of LED street/ building light fitting 60 watt 230 V AC outdoor type with high pressure die-cast aluminum hosing, PC diffuser, and heat resistant complete with integrated electronic driver with high efficiency including 32mm bore GI pipe bracket mounted on wall or roof using clamps, nuts, bolts, washers, fasteners etc.complete with polycarbonated cover, IP 65/66 protection and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
12Earthing complete in repair with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to 4mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009.Note :-1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. 2. On testing after completion if the desired earth resistance is not obtained the earthing will be re-done at no extra cost. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57466102
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20 Lakhs
LAST DATE 02-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Building Security Light, Eathing, Mccbs/ Mcbs Db Box/ Tpn And Connected Work Of Building At D-Iv And D-V Zone & Mes Office Area Under Age E/M-Ii Of Ge(N) Mamun.
Basic Detail
Tender No GE(N)/M-68/2026-27
Bidding Type Tender
Location
City Pathankot
State Punjab
Key Dates
Publish Date 11 Sep 2026
Submission Date 02 Oct 2026
Open Date 09 Oct 2026
Finance
Tender Value 20 Lakhs
Tender Fee 500
EMD 40000
Exemption Not Available
Document List
03eb0d47-97df-4603-bf77-38341fe2e7d4.html
BOQ_884356.xls
Tender68.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Oct 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
html

03eb0d47-97df-4603-bf77-38341fe2e7d4.html

xls

BOQ_884356.xls

pdf

Tender68.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail