Tender For Electrical Renovation Work At Ped Lab Of Electrical Engineering Department At Nit Silchar
Tender Value
9.67 Lakhs
Estimated cost
Bid Submission
26 Sep 2026
14 days left
EMD
19354
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cachar → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Renovation Work At Ped Lab Of Electrical Engineering Department At Nit Silchar
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 3 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wir |
| 5 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 6 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 7 | 4 X 10sq. mm + 2 X6 sq. mm earth wire |
| 8 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 5 x 6 sq. mm |
| 9 | 5 x 4 sq. mm |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 11 | 15/16 A switch |
| 12 | 3 pin 5/6 A socket outlet |
| 13 | 6 pin 15/16 A socket outlet |
| 14 | Supplying and fixing two module stepped typeelectronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 15 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required |
| 16 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required |
| 17 | Installation, Testing and Commissioning of pre-wired,fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required |
| 18 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required. |
| 19 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.300-450 mm sweep |
| 20 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way , Double door |
| 21 | 12 way Double door |
| 22 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 23 | Single pole and neutral |
| 24 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 25 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 26 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. a)900mm, service value ≥ 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum) |
| 27 | 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) |
| 28 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.250 A,50KA,FPMCCB |
| 29 | Supplying of following type and watt LED light including necessarry connection wires etc as required.a)18-20 Watt LED batten light |
| 30 | b)20-22 Watt Surface LED round light |
| 31 | Supplying and fixing 400 mm sweep Wall fan with all necessary connections and materials required etc. |
| 32 | Supply of following sizes of single phase 240 volts heavy duty exhaust fan complete with including all accessories as required. 450mm dia, 900 RPM. |
| 33 | Supplying and fixing following rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.TPN MCB 63 amps |
| 34 | Supplying and fixing following Size, tin copper busbar along with enclosure as required.and as approved by the deptt. 300 Amps |
| 35 | Supplying and fixing following rating and pole, MCCB enclosure in the wall as directed and approved by the deptt 250Amps four pole |
| 36 | Providing and fixing 8 SWG dia G.I. wire on surface with PVC piep/cassing capping for loop earthing as required. |
| 37 | Dismantling of existing wiring system where necessarry including disconnection of every equipments etc and depositing the materials in a specified location as directed by the department |
| 38 | Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium 1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable as specified and directed by the deptt. ( Havells/ RPG/CCI/Polycab/ Finolex make) A2XFaY 240 Sq.mm 4Core armoured U.G. cable |
| 39 | Supplying and fixing including connections of the Aluminium Lugs for following size of PVC insulated and PVC sheathed/XLPE Aluminium conductor cable of 1.1 KV grade as required.a) 240 Sqmm four core cable |
| 40 | Supply and installation of terminal box of ABS type in both side to be fixed in the wooden table(approx size :210 X 260 x 120 )with cable terminals(banana) 4 nos(preferably 4 coulour)and having provision for incoming and outgoing cable with necessary clamps nut bolts etc as required comlete and as per the instruction of the department |
| 41 | Supply and installation of terminal box of ABS type in both side to be fixed in the wooden table(approx size :210 X 260 x 120 )with cable terminals(banana) 2 nos(preferably 2coulour)and having provision for incoming and outgoing cable with necessary clamps nut bolts etc as required comlete and as per the instruction of the department. |
| 42 | Supplying and fixing following size PVC modular box with front plate complete as instructed by the department9 module |
| 43 | Supplying and fixing of following sizes of flexible conduit pipe along with necessary accessories to fix in surface etc. as required |
| 44 | Supplying and fixing following rating,SPN , 240 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amps Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysSep 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender