Educational and Research Institute Boards / Undertakings / PSU Closing in 12 days TDR #57466071

Tender For Conversion Of Overhead Lines To Underground Electrical Cables At P Type Quarters And Providing Input Power To Newly Constructed Community Shed At Nit Silchar

Issued by Boards / Undertakings / PSU · Cachar, Assam
Tender Value
35.09 Lakhs
Estimated cost
Bid Submission
26 Sep 2026
12 days left
EMD
70196
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Cachar → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Conversion Of Overhead Lines To Underground Electrical Cables At P Type Quarters And Providing Input Power To Newly Constructed Community Shed At Nit Silchar

BOQ

Name of Work:- Conversion of Overhead lines to underground electrical cables at P type quarters and providing input power to newly constructed community shed at NIT Silchar
Sl. No. Item Description
1Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
2Above 35 sq. mm and upto 95 sq. mm
3Above 185 sq. mm and upto 400 sq. mm
4Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
5Above 35 sq. mm and upto 95 sq. mm
6Above 185 sq. mm and upto 400 sq. mm
7Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
8Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
9Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required 125 A,36KA,FPMCCB
10250 A,36KA,FPMCCB
11630 A,50KA,FPMCCB
12Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required.
13Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
14Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and neutral
15Triple pole and neutral
16Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium 1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable as specified and directed by the deptt. ( Havells/ RPG/CCI/Polycab/ Finolex /RR make)16 sqmm Three core Armoured UG cable
1725Sq mm Three and half Core armoured U.G. cable
1850Sq. mm. Three and half Core armoured U.G. cable
1970Sq. mm. Three and half Core armoured U.G. cable
20300Sq. mm. Three and half Core armoured U.G. cable
21Supplying and fixing including connections of the Aluminium Lugs for following size of PVC insulated and PVC sheathed/XLPE Aluminium conductor cable of 1.1 KV grade as required.a) 25Sqmm Three and Half core cable
22b) 50 Sqmm Three and Half core cable
23b)70 Sqmm Three and Half core
24C)300 Sqmm Three and Half core
25Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:1(1/2):3 (1 Cement :1(1/2) coarse sand (zone-III) : 3graded stone agreegate20 mm normal size.
26Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) including concrete/road cutting and re-filling etc as required 63 mm dia
27100 mm dia
28Supplying and fixing following rating, four pole, 415 V,MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 Amps
29Supplying and fixing following rating, four pole, 415 V,Change over in the existing panel complete with connections, testing and commissioning etc. as required and directed by the department 125 Amps
30Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical outdoor, compartmentalize cubical type panel board of suitable size made of 18 SWG sheet with a provision for 200 Amps Aluminium busbar, One 125 Amps change over as incomer from two sources,for one 125 AMPs MCCB ,provision for 4 nos 32 Amps DP as outgpoing,one 32 Amps TPN MCB,one 63 AMPS TPN MCB as outgoing etc as specified and directed by the deptt. The panel board is to be erected in 1 : 3 : 6 PCC foundation including excavation of trench and brick soling etc. complete . confirming to IP 65 protection ..The Panel drawing should be approved by the deopartment
31Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical outdoor, compartmentalize cubical type panel board of suitable size made of 16 SWG sheet with a provision for 400 Amps Aluminium busbar, One 250 Amps MCCB as incomer ,provision for 16 nos 32 Amps DP as outgpoing,one 32 Amps TPN MCB,one 63 AMPS TPN MCB as outgoing etc as specified and directed by the deptt. The panel board is to be erected in 1 : 3 : 6 PCC foundation including excavation of trench and brick soling etc. complete . confirming to IP 65 protection ..The Panel drawing should be approved by the department
32Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical outdoor, compartmentalize cubical type panel board of suitable size made of 16 SWG sheet double door with a provision for 800 Amps Aluminium busbar, One 630 Amps MCCB as incomer ,provision for incoming and outgoing cable etc as specified and directed by the deptt. The panel board is to be erected in 1 : 3 : 6 PCC foundation including excavation of trench and brick soling etc. complete . confirming to IP 65 protection .The Panel drawing should be approved by the department Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57466071
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 35.09 Lakhs
LAST DATE 26-09-2026
Authority
Authority Name National Institute Of Technology
Work Description Tender for Conversion Of Overhead Lines To Underground Electrical Cables At P Type Quarters And Providing Input Power To Newly Constructed Community Shed At Nit Silchar
Basic Detail
Tender No NIT-E/Estate/2026-27/05 Sl. No. 02
Bidding Type Tender
Location
City Cachar
State Assam
Key Dates
Publish Date 11 Sep 2026
Submission Date 26 Sep 2026
Open Date 28 Sep 2026
Finance
Tender Value 35.09 Lakhs
Tender Fee 2000
EMD 70196
Exemption Not Available
Document List
6b62ff59-a745-4154-bbdb-cd16f2150b8f.html
BOQ_972843.xls
EMDandtenderfee.pdf
TechnicalBidUpdated.pdf
Tendernotice_1 (10).pdf
TermsconditionsUpdtd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Sep 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

6b62ff59-a745-4154-bbdb-cd16f2150b8f.html

xls

BOQ_972843.xls

pdf

EMDandtenderfee.pdf

pdf

TechnicalBidUpdated.pdf

pdf

Tendernotice_1 (10).pdf

pdf

TermsconditionsUpdtd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders