Tender For Electrification Of Construction Of Centre For Regional Studies Including Shifting Of Main Electric Control System Of Normal And Emergency Power Feeding To Dhanvantri Library And Library Sciences At New C Us University Of Jammu
Tender Overview
Project Description
Tender for Electrification Of Construction Of Centre For Regional Studies Including Shifting Of Main Electric Control System Of Normal And Emergency Power Feeding To Dhanvantri Library And Library Sciences At New C Us University Of Jammu
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with modular type switch,modular plate and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Wire Make ISI Marked Havells/Anchor /HPL /KEI/Polycab Conduit Make - ISI Marked Anchor/High Power /AKG/Equivalent make of required specification to be approved by the Engineer In charge (Group ‘C’) |
| 2 | Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /AKG/) Equivalent make of required specification to be approved by the Engineer In charge 25 mm dia |
| 3 | Supplying and fixing 5 Amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. i. Single pole (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 4 | Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Wire Make ISI Marked Havells/Anchor/KEI/polycab Equivalent make of required specification to be approved by the Engineer In charge )i. 2x1.5 +1x1.5 Sq mm |
| 5 | i. 2x2.5+ 1x2.5 Sq mm |
| 6 | ii. 2x4 +1x4 Sq mm |
| 7 | iv. 4x6+ 2x6 Sq mm |
| 8 | iv. 4x10+ 2x6 Sq mm |
| 9 | Supply and Fixing following ratings, double pole, 240 volts, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as reqd. 63 Amp ratings (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 10 | c.63 Amp 415 volt Four Pole Isolator. |
| 11 | Supply and fixing of following size/module, GI box along with modular base and cover plate for modular switches in recess etc. as reqd A.12 Module |
| 12 | B.6 Module |
| 13 | C. 4 Module (125mmX75mm) |
| 14 | D. 1 or 2 Module |
| 15 | E.8 Module |
| 16 | Supply & fixing 16 amp Modular type switch on the existing switch box or cover including connection as required. (Make: Anchor/Havells /HPL/Sanchi major) |
| 17 | Supply & fixing 6 pin 16 amp Modular type socket outlet on the existing switch box or cover including connection as required (Make: Havells/ Anchor/Sanchi major |
| 18 | Supply & fixing 6 amp Modular type switch on the existing switch box or cover including connection as required (Make :Havells/ Anchor /Sanchi major) |
| 19 | Supply & fixing 3 pin 6 amp Modular type socket outlet on the existing switch box or cover including connection as required(Make: Havells/ Anchor /Sanchi major/) |
| 20 | Supply and fixing of metal Box of following size(nominal size) on the surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required 100mm x 100mm x 60mm deep |
| 21 | 200mm x 125mm x 60mm deep |
| 22 | Supplying and fixing following way, horizontal type three pole and neutral,sheet steel,MCB distribution board,415 V,on surface/recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators)( Havells/Anchor /I.A /HPL Equivalent make of required specification to be approved by the Engineer In charge)i. 8 way(4+24), Double door |
| 23 | Supplying and drawing of following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (Wire Make ISI Marked Havells/HPL/Anchor/KEI/Polycab/ Equivalent make of required specification to be approved by the Engineer In charge) i 1x1.5 sq mm |
| 24 | Supply & fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Make Havells/ Anchor /Major Equivalent make of required specification to be approved by the Engineer In charge) |
| 25 | Supplying and fixingPVC batten/Angle holder including connection etc. as required. (Make Havells/ HPL / Anchor / Sanchi Major Equivalent make of required specification to be approved by the Engineer In charge) |
| 26 | Supplying and fixing 3 pin, 5 A Ceiling Rose on the existing junction box/wooden block including connection etc. as required. (Make Havells/ Anchor / Sanchi Major Equivalent make of required specification to be approved by the Engineer In charge) |
| 27 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Anchor /Havells /HPL Equivalent make of required specification to be approved by the Engineer In charge) i. 400 AMP 35kA TP MCCB |
| 28 | ii. 100 AMP 16kA TP MCCB |
| 29 | Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required. |
| 30 | Supply and erection of galvanized ‘D’ iron clamps complete with shackle insulator (100 mm x 110 mm), G.I bolts, nuts and washers, coach screws etc. as required. |
| 31 | Dismantling of pole /street light standard in brick ballast foundation etc. as required |
| 32 | Earthing with Copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required. |
| 33 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 34 | Non-Schedule Items Supply Installation and Testing of energy efficient LED Lumainiers complete with connection testing and commissioning. Make (Halonix/ Havells/Anchor/Bajaj) Equivalent make of required specification to be approved by the Engineer In charge) 4 feet 18 to 22 watt ,230 volts LED batten type tube light fitting complete . |
| 35 | 2 feet 9 to 12 watt ,230 volts LED batten type tube light fitting complete |
| 36 | 20 to 24 Watt LED recessed/surface mounting 6500 K, 240 Volts Slim Panel down light fittings/luminaries Square 1 Ft X 1Ft Dimensions. Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge) |
| 37 | b. 600mmX600mm surface mounted LED luminaire CRCA sheet housing comprising of White (WH) LED’s connected in series parallel. Fixture should have minimum system lumen of 4500lm & minimum efficiency at System level >=100lumens/ watt, Life of fixture : 50K Hrs. @ L70B50 Lumen maintenance, CCT 5700k with same lumens/w. CRI >80, THD <10%@ 240v ac. An operating Voltage Range of 140 - 270 V. Minimum Internal Surge Protection 3kv, IP 20. Anchor/Helonix/Philips/Havewlls/equivilant make of required specification to be approved by engineer in charge 36W >105<120IM/watt |
| 38 | Supply, Installation , Testing and commissioning of 10W Bulk Head Light. |
| 39 | Supply, Installation , Testing and commissioning of 10 W surface mounted LED Track Light. |
| 40 | Supply/installation of the energy efficient LED flood light luminaries complete with all accessories connection testing and commissioning as required.Make (Bajaj/Surya /Havells/ C&S/ HPL /compact/ Halonix)100 watt,230 volts IP 66/IP65. >135/M/watt |
| 41 | Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/ insulated conductors/strips etc. (Make Electric Field/ Bharti Engineers/Gupta & Friends/ Jai maa/KED) MAIN OUTDOOR /BUILDING CONTROL PANEL a. INCOMING Space for 1 No. 400 Amp 4 pole MCCB of 30 KASpace for 1 No. 150 Amp Changeover Switchb. INDICATING PANEL The indicating panel of the incomer shall be provided with the following:i. Ammeter of required range with ASS, CT's.ii.Voltmeter of required range with VSS.c.Space for 1 No. 400 Amp TPN Al. Bus bar of equal cross section for power load/light load. OUTGOING Space for 4 No. 100 Amp 4 pole MCCB of 30 KADimensions4’0\\"x3’0\\"x1’6\\" |
| 42 | Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/ insulated conductors/strips etc. (Make Electric Field/ Bharti Engineers/Gupta & Friends/ Jai maa/KED) MAIN OUTDOOR /BUILDING CONTROL PANEL a. INCOMING Space for 1 No. 630 Amp TPN Al. Bus bar of equal cross section for Main Power/Light connectionSpace for 1 No. 630 Amp Changeover Switchb. INDICATING PANEL The indicating panel of the incomer shall be provided with the following:i. Ammeter of required range with ASS, CT's.ii.Voltmeter of required range with VSS.c.Space for 1 No. 630 Amp TPN Al. Bus bar of equal cross section for power load/light load. OUTGOING Space for 2 No. 100 Amp 4 pole MCCB of 30 KADimensions4’0\\"x3’0\\"x1’6\\" |
| 43 | Supply, testing and commissioning and Laying of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPE Cable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make: Havells / General/Polycab / Gloster) Equivalent make of required specification to be approved by the Engineer In charge) 2 core 16 sq mm armoured cable |
| 44 | 3.5 core 95 sq mm armoured cable |
| 45 | 3.5 core 185 sq mm armoured cable |
| 46 | 3.5 core 50 sq mm armoured cable |
| 47 | 3.5 core 70 sq mm armoured cable |
| 48 | 3.5 core 150 sq mm armoured cable |
| 49 | 1 core 240 sq mm armoured cable |
| 50 | Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 3 to 5 star rated energy efficient .(Make: Havells /Anchor/USHA /Crompton) Equivalent make of required specification to be approved by the Engineer In charge) |
| 51 | Supply, installation, testing, commissioning of heavy duty 300 mm sweep BEE 1 to 3 star rated energy efficient exhaust fan. Make: ( Anchor/Havellls/Bajaj/Crompton Equivalent make of required specification to be approved by the Engineer In charge) |
| 52 | P/F following rating 230 volts energy saver LED Lamps(Make :Philip /Havells/Bajaj/ Surya/ Crompton/Compact/Halonix Equivalent make of required specification to be approved by the Engineer In charge)i.8 to12 watt LED |
| 53 | Providing/fixing 32 to 40 amp rating , 230 volts SPN MCB in the existing MCB DB or enclose complete with connection testing and commissing complete Job. (Havells/Anchor/HPL make Equivalent make of required specification to be approved by the Engineer In charge) |
| 54 | P/F of 3mm thick phenolic laminated sheets of following size.Crown /Hylam. 9'X6'’ |
| 55 | Supplying and fixing 4 way horizontal type MCB Distribution Board 415V on surface/in recess complete connection as required (But without MCB/RCCB/Isolators. i.4 way, DD For A.C Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge |
| 56 | Supply of swaged type steel tubular pole of following height duly painted with two coats of red oxide and two coats of silver paint made of Mild Steel conforming to IS 2713 part III of 1980 designated as 410 SP15 LT 8 mtr planted in 1.5 m deep pole pit to be dug for the purpose, welded with (300x300x6) mm base plate at bottom including filling back the pit with cement concrete excavation 1:3:6 (1 cement: 3 corse sand:6 graded stone aggregate 40 mm nomial size) (excluding the cost of CC). The planting depth of the pole shall be 1/6 th 0f pole a) 8 mtr height. |
| 57 | Supply and fixing of (50X50)mm press fit type PVC Trunking for drawing the electric wires/Cables. |
| 58 | S/F of 32mm dia G.I pipe for flood light bracket including bending to shape, (40x3)mm flat iron clamp and wiring with 1.5 sqmm PVC insulated wire complete wire complete as reqd. |
| 59 | Supply and fixing of following rating onload I-O-II Four pole with advanced neutral on load change over switch confirms to IS 13947 (Part-3) IEC:609473) (Make I.A/Havells/HPL/Crompton Equivalent make of required specification to be approved by the Engineer In charge)150 Amp |
| 60 | 630Amp. |
| 61 | Supply and Fixing of Fan Down Rod Upto 2 feet Length including nut bolts and rubber insulator. |
| 62 | 3.5 core 185 sq mm armoured cable |
| 63 | 3.5 core 70 sq mm armoured cable |
| 64 | 3.5 core 150 sq mm armoured cable |
| 65 | 1 core 240 sq mm armoured cable |
| 66 | Supply of following size ACSR conductor of required aluminum and steel strands including binding etc. as required as per IS O 398 part 2a) 7/2.11 mm to 7/4mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender