Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #57464391

Tender For Special Repair To Sewage Line , Manhole And Septic Tank At Ge Sagar

Issued by Statutory Bodies & Commissions/Committees · Sagar, Madhya Pradesh
Tender Value
30 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
12 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sagar → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Sewage Line , Manhole And Septic Tank At Ge Sagar

BOQ

Name of Work:- SPECIAL REPAIR TO SEWAGE LINE , MANHOLE AND SEPTIC TANK AT GE SAGAR
Sl. No. Item Description
1Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed.
2All as per item No. 01 above but depth of excavation exc 1.50 M but n'exc 3.00m
3Removal of excavated material (soil) to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
4Returning filling in excavated material including spreading, levelling, watering and well ramming in layer n.exc 25 cm thick complete all as specified and directed.
5Demolition and breaking up drain pipes (salt glazed ware)/ RCC/HDPE pipe of 150mm bore/dia pipe set in cement mortar, including bedding, hunching pcc etc, complete all as specified and directed.
6All as per Srl item No 05 above but 200mm bore / dia pipe.
7All as per Srl item No 05 above but 300mm bore / dia pipe.
8S&F HDPE double wall corrugated (DWC) sewage pipe of 150 mm internal bore, SN-8 grade, as per IS 16098 Part-II 2013 laid in trenches, jointed and tested as per manufacturer's instruction complete all as specified and directed
9S&F HDPE double wall corrugated (DWC) sewage pipe of 200 mm internal bore, SN-8 grade, as per IS 16098 Part-II 2013 laid in trenches, jointed and tested as per manufacturer's instruction complete all as specified and directed
10S&F HDPE double wall corrugated (DWC) sewage pipe of 300 mm internal bore, SN-8 grade, as per IS 16098 Part-II 2013 laid in trenches, jointed and tested as per manufacturer's instruction complete all as specified and directed
11Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
12M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundations/ mass concrete complete all as specified and directed.
13Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
14M&L for Brick work with sub- class ‘B’ old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and directed
15M&L for Brickwork with sub- class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar (1:4) complete all as specified and directed
16M&L Brick work with subclass 'B' old size bricks in one brick thick honey comb walling built in CM 1:4 complete all as per specified and directed.
17M&L for Loose filling with Broken bricks aggregates of gauge 80 to 150 mm in soakage pits, soakage wells etc complete all as per specified and directed.
18M&L for 15 mm thick rendering in cement mortar (1:4) on brick / concrete/ stone walls, surfaces finished even and fair without using extra cement complete all as specified and directed.
19M&L for cutting into existing manholes for connecting new or old drains of dia 150mm / 200mm, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete all as specified and directed
20Cleaning of Septic tank of any capacity and in any location by mechanical means using truck mounted vacuum suction pump/machine, capacity not less than 15 cum/hr, taking off complete sludge including water and cleaning the tank with entire satisfaction of Engr-in-charge and deposited outside the MOD land complete all as specified and directed.Note: All T&P required for completing the job shall be arrange by contractor and rates shall be deemed included in quoted unit rates (ii) Net volume (internal dimension and fluid height shall be measured for calculating cum qty)
21Demolition of cement concrete (reinforced) below or above the ground floor, not exc 15cm thickness (reinforcement cut as required to facilitate demolition) such as in cooking platform, chajja etc complete all as specified and directed.
22M&L for RCC( Nominal mix), 1:2:4 type B-1 (using 20mm graded stone aggregates) as in slabs supported on walls complete all as specified and directed.. .
23M&L for use and waste of form work to soffits of suspended slabs, flat or curved roof slabs, floor slabs, n'exc 200mm thick, fair finished concrete surface complete all as specified and directed..
24M&L for use and waste form work to edges of concrete flats, treads, breaks in floors, window cills, concrete rail-ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide; rough finished concrete surface, complete all as specified and directed.
25M&L for mild steel TMT bars 10 mm dia and above cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
26M&L for mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Gde Fe complete all as specified and directed.
27M&L for mild steel round bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending as in manhole covers handles, steps, rungs etc complete all as specified and directed.
28M&L for dewatering of soak well of any dia and depth completely by pumping out the water by mechanical means and removing it to nearby nala complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57464391
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 05-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Sewage Line , Manhole And Septic Tank At Ge Sagar
Basic Detail
Tender No GE/SGR/TOK-84 OF 2026-27
Bidding Type Tender
Location
City Sagar
State Madhya Pradesh
Key Dates
Publish Date 11 Sep 2026
Submission Date 05 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
BOQ_884341.xls
f8bfbce1-5943-4fbc-828f-486852e89647.html
GP_SC_SC_PSTOK84.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_884341.xls

html

f8bfbce1-5943-4fbc-828f-486852e89647.html

pdf

GP_SC_SC_PSTOK84.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders