Tender For Repair/ Replacement Of Street Lights, Pathway Lights, Garden Lights, Flood Lights And Connected Works At Outlaying Area Of Nofra, installation Shikra, Nt Pool , Boat Pool Under Ge (Nw) Nofra.

Issued by Statutory Bodies & Commissions/Committees · Mumbai, Maharashtra
Tender Value
47.99 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
14 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Street Lights, Pathway Lights, Garden Lights, Flood Lights And Connected Works At Outlaying Area Of Nofra, installation Shikra, Nt Pool , Boat Pool Under Ge (Nw) Nofra.

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF STREET LIGHTS, PATHWAY LIGHTS, GARDEN LIGHTS, FLOOD LIGHTS AND CONNECTED WORKS AT OUTLAYING AREA OF NOFRA, INS SHIKRA, NT POOL , BOAT POOL UNDER GE (NW) NOFRA.
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 Mtrs. wide and not exceeding 1.5 Mtrs. in depth for foundation, laying of cables etc. and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
2Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25cm depth in soil complete all as specified and directed by Engineer-in-Charge.
3Removing excavated material (Soil) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs. above the starting point complete all as specified and directed by Engineer-in-Charge.
4Cutting and removing grass, vegetation bushes etc and brooming in side/outside of water supply electric supply installation and removing all rubbish to a distance not exceeding 50 m as directed and cleaning/ brooming in water /electric supply station complete all as specified and directed by Engineer-in-Charge.
5Trimming tree branches on the route of LT line nearer to LT/HT line, pump house, pipe, roof, street light fitting & poles complete all as specified and directed by Engineer-in-Charge.
6Taking down and Checking and repairs to street light fitting from Truss ,Highbay light, flood light , Perimeter light , Post Top Lanterns , Obstruction light, Avaition light fittings inside / out side of NT POOL, SASSON COMPLEX , BOAT POOL, TALWAR CAMP, REIVERA & HARBOUR HEIGHTS, DUXBURY, ADITI AHILYA, VISHAKHA , VANDNA AND FOMA HOUSE , fitting any height street light pole (7/9/11) mtrs, hanger, truss, wall repair and checking and cleaning internal complete wiring, bulb, ignator, holder, rectifying the defects and removing of burnt cable if any including repair/replacing the unserviceable items as mentioned in below items (wherever necessary) and testing the same on ground at site for its serviceability and refixing the same at original place/location complete all as specified and directed by Engineer-in-Charge. Note :- (a) If the contractor have not given job card to his tradesman in any working day and have not attended any complaint , the necessory recovery of Rs. 500/- per day shall be imposed by Engineer-in-charge . (b) Routine check shall be done for all types of non opps street / secutity light fitting in each and every location in routine wise manner every day by tradesman.(c) Driver and cable shall be measured paid and separately.
7S&F in repair cable junction boxes IP 66/67 weather proof for out door installation with knock outs cable entry junction box size not less than 205x255x112 with terminals including complete all accessories, all as specified and directed by Engineer-in-Charge.
8S&F in repair cable junction boxes IP 66/67 weather proof for outdoor installation (with knock outs cable entry junction box size not less than 300x100x450 mm aluminium bus bar 4 strip mounted on protection insulator with two Nos and front openable hinged and locking arrangements including complete all accessories , all as specified and directed by Engineer-in-Charge.
9S&F in repair of LED garden light 9 W cylindrical shaped integral decorative LED bollard with Opal acrylic diffuser and IP 65 With all acessories including PCC foundation tapper plug bolts,nuts,screwed and GI pipe of suitable dia etc complete all as specified and directed by Engineer-in-Charge.
10Supply and fix in repair generation ruby LED post top series IP 65 LED post-top 35 Watt, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source Clear Cover offers bright illumination for different applications including suitable dia of GI pipe and foundation as per OEM complete all as specified and directed be Engr in Charge.
11Supply and fix in repair Cone NXG series 8 watt LED Bollard acts as an imposing street furniture with touch of aesthetic innovative design with uniformly lit diffuser at the upper portion acts a beacon of path guidance in a landscape environment with robust IP 65 rating including PCC foundation, nut bolts etc complete all as specified and directed by Engr in Charge.
12S&F in repair Street light timer, Astronomical time operation, sunrise sunset based operations, Current Rating (In Amps) 63 Amp, Display : Digital, Operating Temperature: -10 to 55, Power/Voltage: 110 - 240VAC including contactor, relay and CRCA enclosure complete all as specified and directed.
13Material and Labour for Attending Faults/Trippings and rectifying /repairing the faults in street light panel/ Junction box/ cable fault/ connection/ busbar including PVC insulating Tapes/Nut bolts/lugs and all as specified and directed by Engineer-In-Charge.(Note : Damaged/Burnt MCCB/MCB/cable/chageover switch will be measured and paid separately)
14Supply only MCCB,4Pole,250 Amps,25kA, 415Volts,50Hz AC including taking down old MCCB complete all as specified and directed by Engr-in-charge.
15Supply only MCCB,4Pole,160 Amps,25kA, 415Volts,50Hz AC including taking down old MCCB complete all as specified and directed by Engr-in-charge.
16Supply only MCCB,4Pole,100 Amps,25kA, 415Volts,50Hz AC including taking down old MCCB complete all as specified and directed by Engr-in-charge.
17Supply only MCCB,4Pole,63 Amps,25kA, 415Volts,50Hz AC including taking down old MCCB complete all as specified and directed by Engr-in-charge.
18Supply only Change Over Switch ,4Pole, 63 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC including taking down old changeover switch complete all as specified and directed by Engr-in-charge.
19Supply only Change Over Switch ,4Pole, 100 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC including taking down old changeover switch complete all as specified and directed by Engr-in-charge.
20Supply only Change Over Switch ,4Pole, 250 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC including taking down old changeover switch complete all as specified and directed by Engr-in-charge.
21Supply only LED driver for street light / highbay light fitting / flood light from 45 watt to 250 Watt 230 volt of any type and size etc to match with existing complete all as specified and directed by Engineer-in-Charge.
22Supply and fixing in repair Steel tubular swaged street light poles complete with pole arms 1.2 m & cast iron base plate ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 , 8.5 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole including taking down old rusted pole complete all as specified and directed by Engineer-in-Charge.(NOTE- Excavation & PCC will be measured and paid separately)
23Supply & fix hot dip galvanized anti corroded weather proof octagonal electric poles 6 mtrs long top mounting on foundation complete with base plate and final including PCC foundation as per manufacturer design with 1500 mm long Arms bracket,tapper plug,bolts nuts and screws incl aluminium painting etc as specified complete all as specified and directed including taking out existing damaged pole with street light bracket complete.
24S&F in repair of new 45 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting Source and LENs embedded toughned glass cover with IP66 Protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge.
25S&F in repair LED Bldg security light 70 Watt indus series powder coated pressure die cast aluminium high power LED bldg security light with heat resistant toughned glass with lens with IP66 Protection complete all as specified and directed by Engineer-in-Charge.
26S&F in repair 120 WATT LED street light made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge.
27S&F in repair 150 WATT LED street light made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge.
28Supply & fix in repair of Industrial highbay integral LED fittings of capacity 120 watt complete and all accessories at top of any height of workshop hanger including proper hanging fixing with angle/rond bar flat iron with clamping as good appearance t complete all as specified and directed by Engineer-in-Charge.
29Supply & fix in repair of Industrial highbay integral LED fittings of capacity 150 watt complete and all accessories at top of any height of workshop hanger including proper hanging fixing with angle/rond bar flat iron with clamping as good appearance complete all as specified and directed by Engineer-in-Charge.
30S&F in repair driver for 2 x 2 feet, 36 Watt 230 volt recess mounted LED light of suitable size and capacity complete all as specified and directed by Engineer-in-Charge.
31S & F in replacement of MCB, SPN 40/63 Amps 10 KA capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed by Engineer-in-Charge.
32S&F in replacement MCB SP 6-32 Amps, 240 Volts complete all as specified and directed by Engineer-in-Charge.
33S&F in replacement MCB , TPN 40-100 Amps capacity, C Curve type suitable for 240 volts AC supply short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed by Engineer-in-Charge.
34S&F in replacement 120 Watt LED flood light with high performance luminare with pressure die- cast housing toughened glass and secondary lens optics with IP 66 ingress protection efficency 120 lm/W complete all as specified and directed.
35S&F in replacement 150 Watt LED flood light with high performance luminare with pressure die- cast housing toughened glass and secondary lens optics with IP 66 ingress protection efficency 120 lm/W complete all as specified and directed.
36S&F in replacement 250 Watt LED flood light with high performance luminare with pressure die- cast housing toughened glass and secondary lens optics with IP 66 ingress protection efficency 120 lm/W complete all as specified and directed.
37Supply and fix in repair of test Link for connecting the earth pit and down conductor complete all as specified and directed by Engineer-in-Charge.
38Supply and fix 1x 50 sqmm copper conductor with 0.5 mm thick PVC sheathed cable including taking down old cable complete all as specified and directed.
39Supply and fix iron clamp (flate 25 x 4 MM) with nuts, bolts, washers and removing old clamps complete all as specified and directed by Engineer-in-Charge.
40Supply and fix bracket for street/security light fitting made of GI pipe 25 / 40 mm light grade 1.2 m long bend to shape including two Nos of clamps nuts and bolt as required including taking down old bracket complete all as specified and directed by Engineer-in-Charge.
41supply and fix bracket for street/security light fitting made of GI pipe 50 mm light grade 1.2 m long bend to shape including two Nos of clamps nuts and bolt as required including taking down old bracket complete all as specified and directed by Engineer-in-Charge.
42M&L for straight through jointing heat shrinkable kit for cable of 240/300 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge.
43M&L for straight through jointing heat shrinkable kit for cable of 95 to 185 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge.
44Supply and lay Insulated screened PVC bedded, copper electric cables 1100 Volts grade with stranded Copper conductor of size 1.5 sq mm 2 core. laid in duct / along pole/wall etc including making connection and taking down old cable complete all as specified and directed.
45Supply and laying Insulated screened PVC , copper electric cables 1100 Volts grade with stranded Copper conductor of size 2.5 sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge.
46Supply and lay copper cable PVC bedded, electric power cables (heavy duty) 1100 Volts grade with stranded sheathed copper conductor of size 4 Sq mm 2 core. laid in junction box / along pole /street light fitting /wall etc including making connection and taking down old unsv rusted cable complete all as directed.
47Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 10 sq mm 3 core laid in duct / along pole/wall etc including making connection and taking down old cable complete all as specified and directed by Engineer-in-Charge.
48Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 3.5/4core laid in duct / along pole/wall including making connection complete all as specified and directed by Engineer-in- Charge. Please Enable Macros to View BoQ information
49Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 3.5/4core laid in duct / along pole/wall including making connection complete all as specified and directed by Engineer-in- Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57464387
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.99 Lakhs
LAST DATE 30-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Street Lights, Pathway Lights, Garden Lights, Flood Lights And Connected Works At Outlaying Area Of Nofra, installation Shikra, Nt Pool , Boat Pool Under Ge (Nw) Nofra.
Basic Detail
Tender No GE (NW) NOFRA 8579
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 11 Sep 2026
Submission Date 30 Sep 2026
Open Date 05 Oct 2026
Finance
Tender Value 47.99 Lakhs
Tender Fee 500
EMD 96000
Exemption Available
Document List
61fdf01d-2d41-4d48-b547-2f4cf47a6ae3.html
BOQ_884299.xls
Tendernotice_1 (10).pdf
TenderPages8579.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

61fdf01d-2d41-4d48-b547-2f4cf47a6ae3.html

xls

BOQ_884299.xls

pdf

Tendernotice_1 (10).pdf

pdf

TenderPages8579.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders