Tender For Comprehensive Maintenance Of Fire Fighting And Fire Hydrant System And Reapir To Fire Alarm System In Af Stn Agra Under Ge (Af) Tech Area Agra
Tender Value
45 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
22 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Comprehensive Maintenance Of Fire Fighting And Fire Hydrant System And Reapir To Fire Alarm System In Af Stn Agra Under Ge (Af) Tech Area Agra
BOQ
| Sl. No. | Item Description |
| 1 | Comprehensive monthly maintenance of auto fire alarm system installed at Annex 'A', 'B' , & 'C' of 50 SQN in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Microprocessor based fire alarm detection system 04 Zone fire alarm panel- 03 No.(b) Multi-criteria fire detector with base- 130 Nos.(c) Fire Alarm Hooters-12 Nos(d) Fire alarm response Indicators-40 Nos(e) Fire alarm Manual call Point-12 Nos. |
| 2 | Comprehensive monthly maintenance of auto fire alarm system installed at Annex 'D', & 'E' of 50 SQN in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Microprocessor based fire alarm detection system 04 Zone fire alarm panel - 02 No.(b) Multi-criteria fire detector with base- 105 Nos.(c) Fire Alarm Hooters-08 Nos(d) Fire alarm response Indicators-36 Nos(e) Fire alarm Manual call Point-08 Nos. |
| 3 | Comprehensive monthly maintenance of auto fire alarm system installed at Annex 'A', (IPSS Control Room) & 'B' 251 SU in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Microprocessor based fire alarm detection system 08 loop fire alarm panel- 01 No.(b) Multi-criteria fire detector with base- 30 Nos.(c) Fire Alarm Hooters-05 Nos(d) Fire alarm response Indicators-04 Nos(e) Fire alarm Manual call Point-05 Nos. |
| 4 | Comprehensive monthly maintenance of auto fire alarm system installed at New ATC in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Microprocessor based fire alarm detection system 16 loop fire alarm panel- 01 No(b) Multi-criteria fire detector with base- 116 Nos.(c) Fire Alarm Hooters-07 Nos(d) Fire alarm response Indicators-79 Nos(e) Fire alarm Manual call Point-07 Nos. |
| 5 | Comprehensive monthly maintenance of auto fire alarm system installed at POD section in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Microprocessor based fire alarm detection system 4 zone fire alarm panel- 01 No(b) Multi-criteria fire detector with base- 30 Nos.(c) Fire Alarm Hooters-03 Nos(d) Fire alarm response Indicators-30 Nos(e) Fire alarm Manual call Point-01 Nos. |
| 6 | Comprehensive monthly maintenance of auto fire alarm system installed at SRE Bldg in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Microprocessor based fire alarm detection system 04 Zone fire alarm panel - 02 No.(b) Multi-criteria fire detector with base- 130 Nos.(c) Fire Alarm Hooters-12 Nos(d) Fire alarm response Indicators-40 Nos(e) Fire alarm Manual call Point-12 Nos. |
| 7 | Comprehensive monthly maintenance of auto fire alarm system installed at GCA Building in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Microprocessor based fire alarm detection system 08 loop fire alarm panel- 01 No.(b) Multi-criteria fire detector with base- 36 Nos.(c) Fire Alarm Hooters-04 Nos(d) Fire alarm response Indicators-04 Nos(e) Fire alarm Manual call Point-04 Nos. |
| 8 | Comprehensive monthly maintenance of auto fire alarm system installed at Hangar No-04, POL Store, Adwitya -1 ,Adwitya -2,Adwitya -3 of 50 Sqn in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Microprocessor based fire alarm detection system 16 loop fire alarm panel- 05 No(b) Beam fire detector - 04 Nos.(c) Fire Alarm Hooters -16 Nos(d) Flame fire detector - 04 Nos(e) Fire alarm Manual call Point-22 Nos. (f) Multi-criteria fire detector with base- 12 Nos. (g) Fire alarm response indicators - 04 Nos |
| 9 | Comprehensive monthly maintenance of auto fire alarm system installed at PP&RS building 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Microprocessor based fire alarm detection system 16Zone fire alarm panel- 01 No(b) Fire Alarm Hooters -10 Nos(c ) Smoke detector - 65Nos(d) Fire alarm Manual call Point-10 Nos. (e) Fire alarm response indicators - 05 Nos |
| 10 | Comprehensive monthly maintenance of auto fire alarm system installed at 716 SU, IT Cell, AFNET, IMMOLS SA Mafi at AF building 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Microprocessor based fire alarm detection system 04 Zone fire alarm panel- 01 No(b) Fire Alarm Hooters -10 Nos(c ) Smoke detector - 65Nos(d) Fire alarm Manual call Point-10 Nos. (e) Fire alarm response indicators - 05 Nos |
| 11 | Notes For Ser Item No 01 to 10 :- (i) Cleaning inspecting, checking and repairing all the equipments of fire detection system.(ii) 100% operational of all the equipment of fire detection system should be maintained at all time.(iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge(iv) The maintenance shall be carried out through experienced technician.(v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule. (vii) Testing of the entire fire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge. |
| 12 | S&F in replacement lead acid battery of 12 Volt, 7 AH as per site requirement complete all as specified and directed. Make: EXIDE / OKAYA / AMARON |
| 13 | S&F in replacement low intensity Fire Alarm sounders / Sirens electronic type horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measuredat 1.5m with sound output Variation of + 5 db 500m rangecomplete all as specified and directed. |
| 14 | S&F in replacement Detectors Complying with and type certified to EN-45 Addressable type smoke Detector Photoelectric/Optical with base with self built intelligence as per IS:11360 complete all as specified and directed. Make:-Apollo/system senser/Siemens |
| 15 | S&F in replacement remote response indicator complete all as specified and directed. |
| 16 | S&F in replacement XLPE insulated ,PVC sheathed armoured wire/strip ,copper conductor cable of size 1.5 Sqmm 2 core complete all as specified and directed. |
| 17 | S&F in replacement XLPE insulated ,PVC sheathed sheathed armoured wire/strip, copper conductor cable of size 1.5 Sqmm 4 core complete all as specified and directed. |
| 18 | S&F in replacement XLPE insulated ,PVC sheathed sheathed armoured wire/strip, copper conductor cable of size 1.5 Sqmm 8 core complete all as specified and directed. |
| 19 | S&F in replacement XLPE insulated ,PVC sheathed sheathed armoured wire/strip, copper conductor cable of size 1.5 Sqmm 12 core complete all as specified and directed. |
| 20 | Supply and fix in replacement of 2 loop fire alarm control panel complying with BS EN 54 single loop of capacity from 200 detectors & 99 modules upto 200 detector and module per each loop complete all as specified and directed. Make: Honeywell/APOLLO/Siemens/Moorley Note :- Panel should be match with existing system. |
| 21 | Supply and fix in replacement of 4 loop fire alarm control panel complying with BS EN 54 single loop of capacity from 200 detectors & 99 modules upto 200 detector and module per each loop complete all as specified and directed. Make: Honeywell/APOLLO/Siemens/Moorley Note :- Panel should be match with existing system. |
| 22 | S&F in replacement external Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB (Range up to 2000m) complete all as specified and directed. Make: Kheraj / KPT / National / System senser |
| 23 | Repairing, servicing of Diesel Engine Driven Fire Pump suitable for automatic operation of cap 55HP, 1500 RPM complete checking of condition and making serviceable of engine compression, exhaust system, tappet mechanism, lubricating system, cooling system, replacement of oil filter, fuel filter, air filter and any other associated filter and protecting accessories all sorts of oil leakeage by renewal of necessary gasket, replacement of engine oil, chekcing and making alignment of engine with pump ,cleaning of fuel tank and fuel line etc including disconnecting and refixing of Suction and delivery pipe, and transporting to work shop incl loading/unloading for necessary repairs such as remetaling, turning of Pump shaft, bearing case of suction & delivery and replacement of impeller, stage bush, alongwith renewal of unserviceable minor parts, with new spare parts, carrying back from workshop, re-installation of the Pump set all as specified all as specified and directed. Make : Kirloskar. |
| 24 | Repairing, servicing and overhauling of electric induction motor driven Fire Pump suitable for automatic operation of cap 60HP, 1500 RPM 3 Phase 415 Volt, 15 HHZ discharge appx 1620 LPM at 70 Mtr head multi-stage including disconnecting and refixing of Suction and delivery pipe, and transporting to work shop incl loading/unloading for necessary repairs such as remetaling, turning of Pump shaft, bearing case of suction & delivery and replacement of impeller, stage bush, alongwith replacement of unserviceable minor parts, with new spare parts, carrying back from workshop, re-installation of the Pump set complete with existing motor alongwith proper coupling and alignment, complete all as specified and directed. MAKE : Kirloskar |
| 25 | Repairing, servicing and overhauling of Jockey pump 15 HP, centrifugal Pump and Squrrel Cage induction Motor 15 HP, 2900 RPM 3 Phase 415 Volt, 15 HHZ discharge appx 180 LPM at 70 Mtr head, multi-stage including disconnecting and refixing of Suction and delivery pipe, and transporting to work shop incl loading/unloading for necessary repairs such as remetaling, turning of Pump shaft, bearing case of suction & delivery and replacement of impeller, stage bush, alongwith replacement of unserviceable minor parts, with new spare parts, carrying back from workshop, re-installation of the Pump set with existing motor alongwith proper coupling and alignment, complete all as specified and directed. MAKE : Kirloskar.. |
| 26 | M&L For rewinding the Main pump of 60 HP capacity by disconnecting the electrical connections and transporting the work shop and back after rewinding the same by adequate size/guage of copper wire with insulating materials and varnishing the winding and all as specified and directed. |
| 27 | M&L For rewinding the jockey pump of 15HP capacity by disconnecting the electrical connections and transporting the work shop and back after rewinding the same by adequate size/guage of copper wire with insulating materials and varnishing the winding and all as specified and directed. |
| 28 | Comprehensive monthly maintenance of fire fighting and fire hydrant system installed at 50 Squadron in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Electriclal motor driven fire pump of 55 HP- 01 No(b) Disel engine driven fire pump of capacity 55 HP - 01 Nos.(c) Electrical motor driven jockey pump - 01 Nos(d) Electriclal control panel for fire fighting system - 01 Nos(e) MS Pipes 150mm dia-3200 RM(f) 63mm dia gumetal landing valve-44 Nos(g) CI slunice valve 150mm-15 Nos(h) NRV 150mm dia- 15 Nos(j) Butterfly valve 80mm - 33 Nos.(k) Periodical checking and servicing of 63mm dia fire hose pipe 88 Nos at every month , opening and applying the chalk powder and ensuring the no leakage at hose and keeping safely in hose container. |
| 29 | Comprehensive monthly maintenance of fire fighting and fire hydrant system installed at ATC Building in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Electriclal motor driven fire pump of 55 HP- 01 No(b) Disel engine driven fire pump of capacity 55 HP - 01 Nos.(c) Electrical motor driven jockey pump - 01 Nos(d) Electriclal control panel for fire fighting system - 01 Nos(e) MS Pipes 150mm dia-3200 RM(f) 63mm dia gumetal landing valve-44 Nos(g) CI slunice valve 150mm-15 Nos(h) NRV 150mm dia- 15 Nos(j) Butterfly valve 80mm - 33 Nos.(k) Periodical checking and servicing of 63mm dia fire hose pipe 88 Nos at every month , opening and applying the chalk powder and ensuring the no leakage at hose and keeping safely in hose container |
| 30 | Comprehensive monthly maintenance of fire fighting and fire hydrant system installed at PP&RS in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Electriclal motor driven fire pump of 55 HP- 01 No(b) Disel engine driven fire pump of capacity 55 HP - 01 Nos. (c ) Electrical operated motor squirrel cage induction motor 5 HP terrus motor for Fire Alarm system -01 No. (d) Electrical operated submersible pump 5 HP for water lifting to PP&RS building storage tanks -0-1 No.(e) Electrical motor driven jockey pump 15 HP - 01 Nos(f) Electriclal control panel for fire fighting system - 01 Nos(g) MS Pipes 150mm dia-300 RM(h) 63mm dia gumetal landing valve-06 Nos(j) CI slunice valve 150mm-08 Nos(k) NRV 150mm dia- 06 Nos(l) Butterfly valve 80mm - 08 Nos.(m) Periodical checking and servicing of 63mm dia fire hose pipe 12 Nos at every month , opening and applying the chalk powder and ensuring the no leakage at hose and keeping safely in hose container. |
| 31 | Comprehensive monthly maintenance of fire fighting and fire hydrant system installed at SRE Building in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:-(a) Electriclal motor driven fire pump of 55 HP- 01 No(b) Disel engine driven fire pump of capacity 55 HP - 01 Nos. (c ) Electrical operated motor squirrel cage induction motor 5 HP terrus motor for Fire Alarm system -01 No. (d) Electrical operated submersible pump 5 HP for water lifting to PP&RS building storage tanks -0-1 No.(e) Electrical motor driven jockey pump 15 HP - 01 Nos(f) Electriclal control panel for fire fighting system - 01 Nos(g) MS Pipes 150mm dia-300 RM(h) 63mm dia gumetal landing valve-06 Nos(j) CI slunice valve 150mm-08 Nos(k) NRV 150mm dia- 06 Nos(l) Butterfly valve 80mm - 08 Nos.(m) Periodical checking and servicing of 63mm dia fire hose pipe 12 Nos at every month , opening and applying the chalk powder and ensuring the no leakage at hose and keeping safely in hose container. |
| 32 | Notes for Item No 27to 30 :- (i) Cleaning, inspecting, checking and trial run of all the equipments of fire fighting system.(ii) 100% operational of all the equipment of fire fighting system should be maintained at all time.(iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge.(iv) The maintenance shall be carried out through experienced technician.(v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule. (vii) Testing and trial run of the entire fire fighting and fire hydrant system and servicing the all pump sets and all rotor parts of pumps by applying the lubricants as per OEm recommandations and all eqpts servicing report shall be carried out and report shall be submited regardinding functioning of the system complete all as specified and directed by Engr-in-charge. |
| 33 | Taking up or down old MS pipe with all fitting from trenches in any length from site a complete all as specified and directed for the following sizes :- |
| 34 | (a) 150 mm dia |
| 35 | (b) 100 mm dia |
| 36 | (c) 80 mm dia |
| 37 | Supply, laying, jointing, testing and commissioning of ISI marked ERW MS pips heavy duly welded the joints with and including specials etc like bends, tees, reducers, flanges etc. incl all supports and coating with anticorrosion treatment etc., providing tapping for pressure guage and other instruments, making holes/chasing in wall/ RCC slab if required, including making good the same as original complete all as specified and directed for the following sizes:-. |
| 38 | (a) 150 mm dia |
| 39 | (b) 100 mm dia |
| 40 | (c) 80 mm dia |
| 41 | Excavating in trenches in soft/loose soil n.exc 1.5M wide and n.exc 1.5M in depth for foundation, laying pipes, cables etc n.exc 10Sqm on plan and getting out in soft/loose soil etc complete all as specified and directed. |
| 42 | M&L for returning, filling of soft/loose soil including spreading, leveling watering and well ramming in layers n.exc 25 cm etc complete all as specified and as directed. |
| 43 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point etc complete all as specified and as directed.. |
| 44 | M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings all as directed. |
| 45 | Supply & installation, testing and commissioning in renewal of ISI marked single headed 63mm dia Hydrant valve single headed inlet with 63mm dia female intantaneous outlet confirming to IS 5290 on the fire wet riser/down comer including making 80NB pipe connection with riser fixing the landing valves including nuts, bolts, gaskets, caps, chains etc. testing the hydrant and completing the work in all respect complete all as specified and directed. |
| 46 | Supply and fixing in replacement of ISI marked cast iron double flanged sluice valve of 150mm size rising type stainless steel spindle as per IS : 13095, PN 1.6 class including nuts, bolts, gaskets, flanges & washers etc and testing complete all as specified and directed.Make : Kirloskar/Kartar/Venus/Zaloto/Kalpana. |
| 47 | Supply and fixing in replacement ISI marked cast iron double flanged Non Return sluice valve 150mm dia as per IS : 5312, part I including nuts, bolts gaskets, and washers etc. complete all as specified and directed. Make : Kirloskar/Kartar/Venus/Zaloto/Kalpana |
| 48 | Supply and fixing in replacement ISI marked cast iron double flanged Non Return sluice valve 100mm dia as per IS : 5312, part I including nuts, bolts gaskets, and washers etc. complete all as specified and directed. Make : Kirloskar/Kartar/Venus/Zaloto/Kalpana |
| 49 | Supply and fixing in replacement ISI marked cast iron double flanged Non Return sluice valve 80mm dia as per IS : 5312, part I including nuts, bolts gaskets, and washers etc. complete all as specified and directed. Make : Kirloskar/Kartar/Venus/Zaloto/Kalpana |
| 50 | Supply, fixing ,testing & commissioning in renewal of 150mm dia Butterfly valve ISI marked including nuts, bolts gaskets, and washers etc. complete all as specified and directed. Make : Kirloskar/Kartar/Venus/Zaloto/Kalpana |
| 51 | Supply, fixing ,testing & commissioning in renewal of 100mm dia Butterfly valve ISI marked including nuts, bolts gaskets, and washers etc. complete all as specified and directed. Make : Kirloskar/Kartar/Venus/Zaloto/Kalpana |
| 52 | Supply, fixing, testing & commisioning in renewal of 20mm bore and 30 meter long hose (Rubber lined Dunlop pipe) and hose reel drum for first aid fire fighting conforming to IS :5132, with full swing drum, fixing brackets, 5mm dia shut off gun metal nozzle, 32mm dia, hand lever operated ball valve, connecting directly from the riser through 25 mm dia GI pipe with sockets, elbows, nipple etc. including providing operating instructions on a metal plate and fixing it near hose reel drum. The system shall be complete in all respects complete all as specified and directed. |
| 53 | S&F in renewal gun metal ISI marked 63mm dia instataneous pattern short branch pipes with 15 mm dia Nozzle suitable for interconnections to hose pipe coupling complete all as specified and directed. |
| 54 | S&F in renewal water monitor branch pipe of twisted neck of long nose made by aluminum alloy and body is cast iron made anf haviong the one MS handle the whole assemble having the flexible neck to rotate 360 degree and connected accessories and all as specified and directed. |
| 55 | S&F in renewal ISI marked RRL (IS : 636 type II) fire hose pipe 15meter long and 63mm dia with ISI marked (IS : 903) gun metal male and female coupling complete all as specified and directed. |
| 56 | Supply and fix Gun metal fire brigade in let connection for connecting to external fire hydrant ring main consisting of 2 way 63mm dia instantaneous type male coupling with built in check valves 150mm dia, flanged outlet complete with all accessories complete all as specified and directed |
| 57 | Supply & fixing in renewal of Pressure Switch complete all as specified and directed. |
| 58 | Supply & fixing in renewal dial type Pressure gauge with isolation cock at hydrant station of dial dia 150 mm and calibration 0-14 Kg/Sqcm complete all as specified and directed. |
| 59 | Supply and fixing in renewal of weather proof standard fire hose cabinet of size750mm x 600mm x 250mm outdoor type suitable for accommodating single headed hydrant valve made of not less than 16 SWG MS sheet having central opening glassed door of size 1M X 0.3M (4mm thick clear glass) including necessary locking arrangement with two numbers MS handle of size 150mm for housing, 15 meter long fire hose pipes, branch pipe and hydrant valve as required including painting (Two coats of the fire red colour over one coat primer). The cabinet shall be mounted on brick masonry (i.e) platform (brick work with sub class 'B' bricks in CM 1:4 of size 1.2M X 1M and 0.3M height, two coats of white wash over 10 mm thick rendering in CM 1:4) and supported with MS frame made of Angle iron (75X75X6 mm size) as desired. The words \\"FIRE HOSE\\" to be painted on the box with one coat of synthetic emamel paint of red colour complete all as specified and directed. |
| 60 | Supply and fix in renewal addressable type Manual Call Point break glass type compatible with main fire alarm control board microprocessor based as per IS-2189 and including chain hammer facility and blinking facility complete all as specified and directed. |
| 61 | Supply & fixing repair indicating lamps 22.5 mm dia LED type, 230 V AC to show three pase avalibility complete all as specified and diredted by Engr-in-charge. |
| 62 | Supply and fix in repair fire alarm sounders/sirens electronic type horizontal two stage continious normal operating for atleast 50 minuteswith sound level 65db to 120 db measured at 1.5m with sound output variation+5db 1000m range, |
| 63 | Supply and fix in replacement of brass body open head type automatic sprinkler quick/early response type as per IS 15105/TAc guidelines, 79 degree te,perature rating, pendent type of following types:- (i)Type- pendent type, (ii) Size: 15 mm dia, (iii) Finish: Brass, (iv) Operating temp- 79° C complete all as specified and directed. |
| 64 | Supply and fix in renewal of 15 mm dia surface captive rosette operating temp 57° C |
| 65 | Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 but Addressable type multisensor detector with heat and smoke combination |
| 66 | Supply & fixing repair/ replacement of Ammeter 0-100 volts digital type complete all as specified and diredted by Engr-in-charge. |
| 67 | Supply & Fixing in renewal of steel water Tubes, 'Medium grade' of size 40mm galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors of complete all as specified and directed |
| 68 | Supply & Fixing in renewal of steel water Tubes, 'Medium grade' of size 25mm galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors of complete all as specified and directed |
| 69 | Supply and fix in renewal XLPE insulated steel wire/armoured stranded copper conductor of size 1.5 sqmm x 3 core, 230 Volt grade, fixed on wall/surface with MS saddles complete all as specified and directed. |
| 70 | Supply and Fixing in replacement of contactor 3 pole 415 volts 100 Amps with operating voltage 440 Volts and fixing on existing LT panel for Fire fighting motor of capacity 60 HP along with disconnecting the electrical cionnetions of old one and fixing the nbew one with proper electrical connection and all as specified and direted. |
| 71 | All as per Ser No.66 above but of capacity 32 Amp |
| 72 | S&F in replacement of sub main wiring drawing in and including concealed PVC conduit not less than 25mm dia medium grade with PVC cable 1.5 Sqmm nominal area 2run single core PVC insulated unsheathed cable with stranded copper conductor incl 1.5 Sqmm size PVC cable stranded copper conducter as earth continuity wire and connected to earth dolly with proper crimping of thimbles bottle type and all as specified and directed. |
| 73 | All as per Ser No.68 above but size of wire is 2.5 sqmm |
| 74 | S& F in repair brass heavy duty foot valve of size 80 mm complete all as directed by Engr-in-charge. |
| 75 | S& F in repair brass heavy duty foot valve of size 100 mm complete all as directed by Engr-in-charge. |
| 76 | S& F in repair brass heavy duty foot valve of size 150 mm complete all as directed by Engr-in-charge. |
| 77 | M&L for preparation of old painted surface of DG Set/ Motor/ All sizes of pipes complete by scrapping / removing old paint / dust etc and painting with two coats of synthetic enamel paint (colur & tint as approved) over a coat of primer including caliberatation of capacity complete all as specified and diredted by Engr-in-charge. |
| 78 | Supply & fixing repair/ replacement of voltmeter 0-500 volts digital type complete all as specified and diredted by Engr-in-charge. |
| 79 | M&L for earthing in replacement with galvanized steel earth plate electrode of size 600cm x 600cm x 6 mm thick buried directly in ground earth pit not less than 2.25 mtr below normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth, GI strip of size 25x4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point ,PCC pit with angle iron frame 300 x 300mm size, Machine cut Jodhpur stone slab pit cover 300x300 mm size with 12mm MS Rod handle for lifting, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work complete all as specified and directed by Engr in Chanrge.Note :- (i)The earth pit shall be refilled by boulders free from vegetable soil.(ii) Earthing shall be tested by contractor in presence of JE /Engr-in-Charge. Record shall be maintained. Payment shall be admissible only after satisfactory test results. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
TodayOct 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysOct 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 29 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender