Tender For Renovation Of Room No 303 & 305 For Cgl
Tender Value
27.50 Lakhs
Estimated cost
Bid Submission
02 Oct 2026
18 days left
EMD
55005
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Room No 303 & 305 For Cgl
BOQ
| Sl. No. | Item Description |
| 1 | APPENDIX - A-CIVIL WORKS |
| 2 | Man mazdoor for cutting,conveying and removing the old & deteriorated log pieces lying on the premises |
| 3 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 4 | Demolishing R.C.C. work manually/ or by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 5 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin-charge |
| 6 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 7 | In cement mortar |
| 8 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 9 | Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. |
| 10 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 11 | Labour for cutting C.I. pipe with steel saw. Or labour for cutting C I. pipe wrapped with insulation materials by steel saw |
| 12 | 100 mm diameter C.I. pipe |
| 13 | 125 mm diameter C.I. pipe |
| 14 | 150 mm diameter C.I. pipe |
| 15 | 200 mm diameter C.I. pipe |
| 16 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : or Dismantling C I. (centralised) Air-Conditioner pipes wrapped with insulation materials including stacking the materials within 50m lead |
| 17 | 100 mm dia pipe metre |
| 18 | 150 mm dia pipe metre |
| 19 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix) |
| 20 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 21 | Of area 3 sq. metres and below |
| 22 | Of area beyond 3 sq. metres |
| 23 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : |
| 24 | Of area 3 sq. metres and below |
| 25 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 26 | All kinds of soil |
| 27 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 28 | All kinds of soil. |
| 29 | CC 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources |
| 30 | Providing and laying in position specified grade of Reinforced Cement Concrete(RCC), excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level -- 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 31 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 32 | cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 33 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 34 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 35 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 36 | Centering and shuttering including strutting, propping etc. and removal of form for- columns |
| 37 | Centering and shuttering including strutting, propping etc. and removal of form for- Foundations, footings, bases of columns, etc. for mass concrete |
| 38 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 39 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 40 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 41 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:- Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 42 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 43 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 44 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 45 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 46 | 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) |
| 47 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.- |
| 48 | Hot finished welded type tubes |
| 49 | Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 micronsminimum to avoid scratches during transportation and should besupplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto anypitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shape wherever required. |
| 50 | Structural steel work in single section fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. For Grills |
| 51 | Providing & fixing Stainless fly proof wire gauze to windows clerestory windows & doors with steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides - and fixing it with suitable Aluminium locking clips or sections |
| 52 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 53 | 50mm average thickness |
| 54 | 75mm average thickness |
| 55 | 25 mm average thickness |
| 56 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge |
| 57 | Bars upto 12 mm diameter metre |
| 58 | Bars above 12 mm diameter metre |
| 59 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 60 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 61 | Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make |
| 62 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge |
| 63 | 12 mm average thickness. |
| 64 | Providing, mixing and applying SBR polymer (of approved make @minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness |
| 65 | 50mm thick in Grade M 25 with cement content not less than 330 kg per cum |
| 66 | 75mm thick in Grade M 25 with cement content not less than 330 kg per cum |
| 67 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 68 | Size of Tile 600x600 mm |
| 69 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 70 | Size of Tile 600x600 mm |
| 71 | Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. |
| 72 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 73 | Size of Tile 600x600 mm |
| 74 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work - Exposed on wall) |
| 75 | 25mm nominal dia pipe |
| 76 | 32 mm nominal dia Pipes |
| 77 | 40 mm nominal dia Pipes |
| 78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge- Concealed work, including cutting chases and making good the walls etc. |
| 79 | 20 mm nominal dia Pipes |
| 80 | 25 mm nominal dia Pipes |
| 81 | for fixed portion- Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): |
| 82 | For fixed portion |
| 83 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 84 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 85 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 86 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. Pre-laminated particle board with decorative lamination on both sides |
| 87 | Providing and fixing 04 mm thick Aluminium Composite Panel(ACP) double side coated and factory finished decorative lamination on both sides or faces , in panelling fixed in aluminum doors, windows shutters and partition frames with aluminium clips,beedings or aluminium locking arrangements or C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in-charge. |
| 88 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 89 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 90 | With Frosted glass panes of 4 mm thickness (weight not less than 12.50 kg/sqm) |
| 91 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 92 | 200x10 mm |
| 93 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 94 | 125mm |
| 95 | Supplying and fixing Aluminium handle with locking arrangements suitable for aluminium windows |
| 96 | Supplying and fixing 300 mm Aluminium aldrop |
| 97 | Supplying and fixing I-max hinges |
| 98 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineerin-charge complete. |
| 99 | 205 X 19 mm |
| 100 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 101 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. |
| 102 | Powder coated minimum thickness 50 micron aluminium |
| 103 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 104 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete |
| 105 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm |
| 106 | fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 107 | GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. sqm 1591.70 |
| 108 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) |
| 109 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall bepaid for separately). |
| 110 | Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 111 | Frame size 65 x 100 mm |
| 112 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of Shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 113 | 35 mm thick |
| 114 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : |
| 115 | 25x64x2.50 mm |
| 116 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : |
| 117 | 250x10 mm |
| 118 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete |
| 119 | Providing and fixing bright finished brass handles with screws etc. complete: |
| 120 | 125 mm |
| 121 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 122 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 123 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 124 | Finishing with Delux Multi-surface paint system for interios and exteriors using primer as per manufactures specification - Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 125 | Applying priming coats with primer of apprd brand and manufact, having low VOC content -- with water thinnable cement primer on walls surface having VoC content less than 50gm/lit |
| 126 | Finishing walls with Acrylic Smooth exterior paint with Silicone additives of required shade Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface |
| 127 | Wall painting with premium acrylic emulsion paint of interior grade having VOC content less than 50 gm/l of apprd , including applying additional coats wherever required to achieve even shade and colour on old work - two coats |
| 128 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete |
| 129 | On concrete work |
| 130 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: one or more coats on old work |
| 131 | Melamine polishing on wood work (one or more coat) |
| 132 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineerin-Charge.- (apply DrFixit Roof seal select/ultra like material for horizontal surface and DrFixit Rain coat select/ultra like material for vertical surfaces- work shall be carried out by engaging company/ manufacture approved trained water-proof applicators after the removal of fungas & dirt by using pressure wash of water and filling the cracks with suitable sealents or crack filler by using putty blade) |
| 133 | Sub Total-A |
| 134 | Total Amount for Non-DSR Items |
| 135 | Total Amount for DSR Items |
| 136 | Modified cost on DSR item after using Correction factor on DSR 2023 on account of GST@ 0.973 |
| 137 | add 36% towards cost index |
| 138 | Grand Total -(Civil)-A |
| 139 | APPENDIX - B-ELECTRICAL WORKS |
| 140 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C |
| 141 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 142 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 143 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 144 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 145 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 146 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 147 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit /CMS as required. |
| 148 | 6 x 1.5 sq. mm |
| 149 | 3 x 4 sq. mm |
| 150 | 6 x 4 sq. mm |
| 151 | 9 x 1.5 sq. mm |
| 152 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 153 | 20 mm |
| 154 | 25 mm |
| 155 | Supplying and fixing of uPVC cable management system (wall trunking) of following sizes on surface with all accessories etc required.105mm x 50mm |
| 156 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 157 | 1 or 2 Module (75mmX75mm) |
| 158 | 3 Module (100mmX75mm) |
| 159 | 6 Module (200mmX75mm) |
| 160 | 12 Module (200mmX150mm) |
| 161 | 8 Module (125mmX125mm) |
| 162 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 163 | 15/16 A switch |
| 164 | 6 pin 15/16 A socket outlet |
| 165 | Telephone socket outlet |
| 166 | Data socket outlet |
| 167 | Supply,Installation, testing and commissioning following sizes of 250 mm plastic body exhaust fan in the existing opening including making good the damages, connections, etc. as required. |
| 168 | SITC of Indoor 2feet x2feet square type 30/36W LED lighting luminaire of cool day light output and the following specifications: Lumen output: Not less than 3300lm; Efficiency: 100 lumen/watt; Make: Philips / Wipro , Bajaj or Crompton ,Havells |
| 169 | Supplying and Installing Surface mounted 4 feet linear LED batten fitting with extruded aluminium / metal housing and of the following specifications: Lumen output: not less than 4000 lumen; System efficacy: not less than 100 Lumen/Watt i/c connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 170 | SITC of indoor Surface mounting LED downlighter having high efficiency diffuser along with suitable constant current driver and complying to the following specifications: Lumen output: not less than 1500 lm; Efficacy: not less than 100 lumen/W i/c connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 171 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 172 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door |
| 173 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 174 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 175 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 176 | 100 A |
| 177 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A |
| 178 | Supplying and fixing following rating,TP MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required .63 A |
| 179 | Sub Total-B |
| 180 | Total Amount for Non-DSR Items |
| 181 | Total Amount for DSR Items |
| 182 | add 32.04% towards cost index |
| 183 | Grand Total -(Electrical)-B |
| 184 | Grand Total -(A+B) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender