Banking and Finance Government Departments Closing in 2 days TDR #57461861

Tender For Rewiring Of The 16 Class Iv Type Flats At Banks Stafff Colony At Gandhinagar, Jaipur (Per Flat Amount In ₹)

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
9.60 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
2 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Rewiring Of The 16 Class Iv Type Flats At Banks Stafff Colony At Gandhinagar, Jaipur (Per Flat Amount In ₹)

BOQ

Name of Work:- Rewiring of the 16 Class IV type flats at banks Stafff colony at Gandhinagar, Jaipur (per flat Amount in ₹)
Sl. No. Item Description
1Carefully disconnecting and dismantling of existing wiring, electrical accessories and electrical gadgets such as Light fixtures, ceiling fans, cabin fans, exhaust fans, water purifier and keep it in Bank's custody in proper manner for reuse. Any damages or short coming found in the accessories /gadgets should be immediately brought to the notice of the Bank.
2Supply Installation Testing and commissioning of SPN MCB DB double door 12 way factory fabricated neatly housed on duly painted with following controls compressing of40 amps DP RCBO (sensitivity 30 mA) - 1 No.20 amps SP MCB C curve, Ik10 KA –6 Nos. 10 amps SP MCB C curve, Ik 10KA – 4 Nos to be fixed in nealtly concealed manner with all accessories and associated civil repairs and minimum damage to structure stability and proper finishing at the location inside the flat as decided by Bank’s Engineers including restoration of power supply in the flat .
3Wiring for circuit from Main DB to respective point in room using 2x2.5 sq. mm. +1x1.5 sqmm Multi-stranded PVC insulated flexible copper conductor FRLSH wire each for phase(Red) and neutral (Black) Multi-stranded (Green) for earth, 1100 volts grade, approved make from Main DB to respective points outlet/board with all accessories such as PVC bends , corners and junction boxes, ceiling rose/connectors etc, in concealed manner though PVC conduit(MMS/HMS) of suitable size for average length of 13 mtr. (Circuit shall be laid in straight concelaed manner with minimum damage to structure stability and proper finishing )
4Wiring for light, Ceiling fan, Exhaust fan, Cabin fan points, using 2x1.5 sq. mm.(Blue/Yellow for phase and black for neutral) Multi-stranded PVC insulated flexible copper conductor FRLS wire each for phase and neutral, 1.5 sq. mm. Multi-stranded to be provided for earth, 1100 volts grade, approved make from switchboard to respective points outlet and all accessories such as PVC bends , corners and junction boxes, ceiling rose/connectors, bulb holder etc, including concealed switchboard of suitable size for accommodating, sockets and switches on switchboard and ceiling fan electronics regulator etc. to be fixed with metal screws along with inter connections with angle, batten holders, 3 plate ceiling rose mounted on square junction box on approved make with required hardware etc. All the wiring should be done for each switch board in concealed manner in FRLS PVC pipe of medium/Heavy duty wherever possible and PVC casing-capping/conduit wherever concealed is not possible.
5Supply and fixing of electronic step regulator modular (2 Module, 100 W) type with necessary accessories etc. as required and as directed (to be installed in bed room/living room and kitchen)
6As per item no. A.4 above, but wiring for bell point using 1.5 sq.mm multi- standards PVC insulated flexible FRLSH copper wire each for phase and neutral 1100 volts grade approved make in PVC concealed conduit with all accessories such as PVC bends, corners and junction boxes etc.. along with fixing and commissioning of existing Slick model bell with existing concealed modular bell push switch complete with interconnection etc. as required and as directed (Note: the scope of work here refers to only supply and laying of circuit in concelaed manner and interconnection as required with existing door bell and existing concealed bell switch at entrance.)
7Same as item no.A.4 above but point wiring for independent 6 Amps plug point with modular type 5 pin socket controlled by one switch housed in the suitable size MS box and double face plate using 2 runs x 2.5 sq. mm and 1 run x 1.5 sq .mm PVC insulated flexible FRLSH copper wire for phase, neutral and earth laying through suitable PVC conduit in concealed systems etc. as required and as directed.
8Same as item no. A.4 above but point wiring for 6 amps 5 pin modular type sockets 2 nos. controlled by 6 amps modular type switches 2 nos housed in the suitable size MS box and double face plate using 2 runs x 2.5 sq. mm and 1 run x 1.5 sq .mm PVC insulated flexible FRLSH copper wire for phase, neutral and earth laying through suitable PVC conduit in concealed systems etc. as required and as directed (for TV etc)
9Same as item no. A.4 above but point wiring for 6 amps 5 pin modular type sockets 1 nos. controlled by 6 amps modular type switches 1 nos and 16 amps 5 pin(round) modular twin type sockets 1 nos. controlled by 16 amps modular type indicator switches 1 nos housed in the suitable size MS box and double face plate using 2 runs x 2.5 sq. mm and 1 run x 1.5 sq .mm PVC insulated flexible FRLSH copper wire for phase, neutral and earth laying through suitable PVC conduit in concealed systems etc. as required and as directed
10Point wiring for 6 Amps plug point with modular type 5 pin socket controlled by one switch within the switch board including inter connections using 2.5 sq.mm FRLSH flexible wire etc. as required and as directed.
11Point wiring for independent 16 amps power point with modular type 5pin(round) twin type socket controlled by one 16 amps modular type indicator switch housed in the suitable size MS box and double face plate using 2 runs x 2.5 sq.mm and 1 run x 1.5 sq.mm PVC insulated FRLSH flexible copper wire with laying through suitable PVC conduit concealed systems as required and as directed..
12Wiring for telephone point with two pair 0.5 sq. mm telephone wire laid from Telephone tag block/ junction box installed in the staircase up to first point in the drawing room along with modular double face plate type telephone socket RJ11 2 gang with shutter all in concealed manner in separate medium duty FRLS PVC pipe not used for electrical circuit wiring. Wiring should done in surface manner wherever concealed is not possible as required and as directed.
13Wiring for Cable TV point with RJ6 cable TV wire laying from cable TV operator junction box installed in the staircase up to first point in the drawing room along with modular plate type TV socket all in concealed manner but not in the same pipe used for electrical circuits,. as required and as directed. (for Bedroom ) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57461861
AUTHORITY Government Departments
TENDER VALUE 9.60 Lakhs
LAST DATE 24-09-2026
Authority
Authority Name reserve bank of india
Work Description Tender For Rewiring Of The 16 Class Iv Type Flats At Banks Stafff Colony At Gandhinagar, Jaipur (Per Flat Amount In ₹)
Basic Detail
Tender No RBI/JPR/Estate/2026-27/1/CPPP
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 10 Sep 2026
Submission Date 24 Sep 2026
Open Date 25 Sep 2026
Finance
Tender Value 9.60 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
5b78d6eb-874d-4307-b32c-c81b9f4f223c.html
BOQ_338518.xls
Tender-Part-I.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

5b78d6eb-874d-4307-b32c-c81b9f4f223c.html

xls

BOQ_338518.xls

pdf

Tender-Part-I.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders