Tender For annual repair & maintenance of Iei & Eei To Garacharma Hospital At Sri Vijaya Puram Under E&M Division Sub Division No-I(R), Apwd, Prothrapur During The Year 2026-27.Sw: Repair And Maintenance Of Air Conditioners In District Hospital At Ga
Tender Overview
Project Description
Tender for annual repair & maintenance of Iei & Eei To Garacharma Hospital At Sri Vijaya Puram Under E&M Division Sub Division No-I(R), Apwd, Prothrapur During The Year 2026-27.Sw: Repair And Maintenance Of Air Conditioners In District Hospital At Garacharma (2Nd Call)
BOQ
| Sl. No. | Item Description |
| 1 | A. Schedule (Staffs)A.C Mechanic (Skilled Worker) |
| 2 | Khalasi (Un-Skilled Worker) |
| 3 | B. Schedule (Materials)Supplying, Installation, Testing and Commissioning of condenser unit complete of split type A/C 1.5 ton capacity |
| 4 | Supplying, Installation, Testing and Commissioning of condenser unit complete of split type A/C 2.0 ton capacity |
| 5 | Pressure Testing for leakage flushing vaccummission the system, gas charging with Freon-R 22 servicing the unit testing for satisfactory performance, replacement of necessary spare parts i/c re-installation of the unit etc as required for AC (1.5 Ton) |
| 6 | Pressure Testing for leakage flushing vaccummission the system, gas charging with Freon-R 22 servicing the unit testing for satisfactory performance, replacement of necessary spare parts i/c re-installation of the unit etc as required for AC (2.0 Ton) |
| 7 | Replacement of defective compressor unit with new one suitable for 2 Ton capacity room AC i/c pressure testing for leakage flushing vaccummission the system, gas charging with freon-22 servicing the unit, painting and testing for satisfactory performance, replacement of necessary spare parts i/c reinstallation of the unit duly tested etc as required. |
| 8 | Replacement of defective compressor unit with new one suitable for 1.5 Ton capacity room AC i/c pressure testing for leakage flushing vaccummission the system, gas charging with freon-22 servicing the unit, painting and testing for satisfactory performance, replacement of necessary spare parts i/c reinstallation of the unit duly tested etc as required . |
| 9 | Supplying of 50 Mfd Capacitor for AC |
| 10 | Supplying of 60 Mfd Capacitor for AC |
| 11 | Supplying of Voltage Stabilizer for 2.0 Ton capacity |
| 12 | Supplying of Voltage Stabilizer (SYSCOM/V-Guard) for 1.5 Ton capacity |
| 13 | Supplying of AC Indoor Blower motor for 2.0 Ton capacity |
| 14 | Supplying of AC Indoor Blower motor for 1.5 Ton capacity |
| 15 | Supplying of Out Door Fan Motor for 2.0 Ton Capacity |
| 16 | Supplying of Out Door Fan Motor for 1.5 Ton Capacity |
| 17 | Supplying of Indoor Unit PC Board for 1.5 Ton Inverter AC Make: Lloyd / Carrier/ Hitachi or its equivalent |
| 18 | Supplying of Outdoor Unit PC Board for 1.5 Ton Inverter AC Make: Lloyd / Carrier/ Hitachi or its equivalent |
| 19 | Supplying of Indoor Unit PC Board for 2.0 Ton Inverter A.C Make Lloyd / Carrier or its equivalent |
| 20 | Supplying of Outdoor Unit PC Board for 2.0 Ton Inverter A.C Make Lloyd / Carrier or its equivalent Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender