Tender For Repair/Replacement Of Fire Alarm System At Mothala Under Ge (Af) Naliya.
Tender Value
10 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
19 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Fire Alarm System At Mothala Under Ge (Af) Naliya.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing & Commissioning in repair of SFS1-CPU card of EST3x fire alarm panel with below specifications:Voltage 24 VDC, Current: Standby 115 mA at 24 VDC Alarm 115 mA at 24 VDCRelay outputs: Quantity 3 (alarm, supervisory, and trouble) UL type CommonContact arrangement Form C Rating 30 VDC at 1 A resistive AUX power outputs: Quantity 2Voltage 24 VDC, resettable or continuous Current 1.0 A each circuit, 1.0 A total Data network (RS-485)Nodes 2 to 64 (requires optional network card) Performance class Class A or Class BWire type Twisted pair, 6 twists per foot, min.Circuit length 5,000 ft. (1,524 m) between any three panels Circuit resistance 90 Ω, max.Circuit capacitance 0.3 μF, max. Serial Port (RS-232) Annunciator port (RS-485)Performance class Class B and Redundant Class B Baud rate 9600 and 38400Wire type Twisted pair, 6 twists per foot, min. Circuit length 4,000 ft. (1,219 m)Circuit resistance 90 Ω, max. Circuit capacitance 0.3 μF, max. Make: EST/Bosch/Honeywell. |
| 2 | Supply, Installation, Testing & Commissioning in repiar of PS10-4B Power Supply board of existing Edwards Fire Alarm Panel (EST3x) 3X-SFS1R Red.SMPS Specifications :Mains voltage 94 to 264 VAC, 50/60 HzAC Input Current : Standby 1.5 amps, Alarm 3.0 amps. Brownout level 93 VRMSBattery charging capacity 65 Ah max. Total Power : Voltage 24vdcStandby Current : 88mA Alarm Current : 169mASupply Ratings : Current 10 amps (UL), 9.0amps (ULC). Output voltage: Special: 24 Vdc, Regulated: 24 Vdc Output current Special: 3 amps, Regulated: 1.5 amps.Operating environment : Temperature 32 to 120 °F (0 to 49 °C) Relative humidity 0 to 93% noncondensing.Make: EST/Bosch/Honeywell. |
| 3 | Supply, Installation, Testing & Commissioning in repiar of 4X-LCD Display unit of EST3x fire alarm panel with below specifications:Operating current:Standby Alarm 55mA 66mALCD display Backlit liquid crystal display 240 x 320 pixels 24 lines of 40 charactersOperating environment TemperatureRelative humidity32 to 120 °F (0 to 49 °C)0 to 93% noncondensing. Make:EST/Bosch/Honeywell. |
| 4 | Supply, Installation, Testing & Commissioning in repiar of Loop card 3-SDC1 of EST3x fire alarm panel with below specifications:Voltage 24 VDCOperating current with fully loaded loop:Standby 3-SSDC1 144 mA; 3-SDDC1 264 mA Alarm 3-SSDC1 204 mA; 3-SDDC1 336 mASmoke power 19.95 VDC max.1Circuit: Configuration Class B, Style 4, DCLB; Class A, Style 6, DCLA Capacity 125 Signature Series detectors and 125Signature Series modules per SLC Resistance 100 Ω with 250 devices Capacitance 0.5 μF max.Wire size 12 AWG (1.5 mm²) max.Termination Removable plug-in terminal strips on the SFS1-CPU main board and Signature moduleOperating environmentTemperature 32 to 120 °F (0 to 49 °C)Relative humidity 0 to 93% noncondensing. Make: EST/Bosch/Honeywell. |
| 5 | Supply, Installation, Testing & Commissioning in repiar of 3X-NET Network Card with the ability to network up to 64 nodes on an EST3 network.The card must support Class B, Class A, and Class X wiring.The 3X-NET adapter card provides two independent RS 485 circuits: one for network data communications and one for digital audio communications.Make: EST/Bosch/Honeywell. |
| 6 | Supply & Fix in repiar 12V/7AH SMF Battery for backup in case of power failure. Make : Exide/Solance/Amaron. |
| 7 | Supply, Installation, Testing & Commissioning in repiar of Programming card for programming of detectors and other devices in FACP Comm.Interface: USB interface Comm.Distance <15m <5m Baud Rate 2400bps Ambient Temperature 0℃~+40℃ Relative Humidity ≤95%, non condensing. Make: GST, Morley IAS, Honeywell. |
| 8 | Supply, Installation, Testing & Commissioning in repiar of RS485 TO RS232 AND VICE VERSA PROTOCOL CONVERTER WITH BELOW SPECIFICATIONS: SUPPLY: SINGLE PHASE 230V AC +/- 10% INPUT: 2 WIRE RS485 OUTPUT: RS232C ISOLATION: 1000V DC OPTICAL ISOLATION BETWEEN INPUT AND OUTPUT CABINET: DIN RAIL MOUNT, ABS MOULDED 12 TERMINAL BOX OF SIZE 70*60*114 MM (H*W*D) |
| 9 | Supply, Installation, Testing & Commissioning in repiar of Process Indicator with retransmission output for monitoring of temperature and humidity (to be installed in RTU panel). Make: MULTISPAN/Radix/Masibus |
| 10 | Supply, Installation, Testing & Commissioning in repiar of RTD/HUMIDITY SENSOR FOR THE MEASUREMENT OF ROOM TEMPERATURE WITH INSTALLATION ACCESSORIES (TO BE INSTALLED INSIDE ROOM TO MEASURE TEMPERTURE). Make –Waree,RADIX,Wika |
| 11 | Supply, Installation, Testing & Commissioning in repiar Remote terminal unit with below specifications: a. 02 nos DI/DO for communication with slave units. b. Digital microprocessor based automatic programmable. c. EEPROM 1000/6000 with soft touch programming buttons. d. SMS sending module to upto 08 mobile numbers. Make : CIMCON/Siemens/Motorola |
| 12 | Supply, Installation, Testing & Commissioning in repiar of GSM/GPRS Antenna compatible with Modem for wireless communication to and from RTU. Make: CIMCON/Siemens/Motorola |
| 13 | Supply, Installation, Testing & Commissioning in repiar of Wireless modem suitable for GSM/GPRS based communication system from RTU to MCS. GSM/GPRS modem to be mounted in RTU enclosureMake: CIMCON/Siemens/Motorola |
| 14 | Supply, Installation, Testing & Commissioning in repiar of Main Board of Siren control panel with the specifications as appended below:-a) Power- AC 230V, 50Hz, 0.5 Ab) configurable for PC Port- RS-232 interface & communication cardc) Battery backup of 04 Hours in non alarm condition and 15 Minutes in alarm condition.Make: Cimcon/Siemens/ABB. |
| 15 | Supply, Installation, Testing, Commissioning & recharge of 5 nos sim cards installed in each RTU panel of fire alarm and siren system installed at AF Stn Mothala & AF Stn Naliya with relevant sms pack. |
| 16 | Supply & Installation in repiar of Panel locks and Grommets of different sizes for cable entry/exit holes in the panel. |
| 17 | Supply, Installation, Testing & Commissioning in repiar of DI/DO, AI/AO circuit boards of siren system control panel. Input and Output range 24v DC. The card works on power supply of SMPS of 24v DC.Make: Frontier or Equivalent. |
| 18 | Supply & Fix in repiar conventional type resettable manual call point with mounting base complying with LPCB approved with the specifications as appended below:-a) Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current)b) Class A/Bc) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a Key,d) Ingress Protection IP-43 & Material-ABSMake: Agni/Ravel/Honeywell. |
| 19 | Supply & Fix in repiar Conventional type heat and photo electric smoke Multi detector with mounting base complying with LPCB approved with the specifications as appended below:-a) Power- 24V, ≤ 0.8 mA (Standby Current) ≤5.0mA (Alarm Current)b) Class A2R,c) Indicator- Red Flashes in normal and illuminates in alarm,d) Ingress Protection IP-22 & Material-ABSMake: Agni/Ravel/Honeywell. |
| 20 | Supply & Fix in repiar 24v 2A Power Supply Card for the power of circuit boards of RTU panel. Make- Altec/Silicon/MeTek. |
| 21 | Supply & Fix in repiar 12V/5V 2A Power Supply Card for the power of circuit boards of RTU panel. Make: Altec/Silicon/MeTek. |
| 22 | Supply & Fix in repiar 12V 3.5AH Backup Battery for power backup of Remote Terminal Unit of Intruder alarm system. Make: Altec/Silicon/MeTek. |
| 23 | M&L for visit of fire alarm engineer for Testing and Commissioning for entire fire alarm system of any one location which includes testing all the accessories and hardaware used for one panel and detect fault and rectify it with fixing of new material Complete all as specified by Engr -in-Charge. Note: Material cost seperately paid to contractor. |
| 24 | Supply & Fix Conventional Type fire alarm panel below specifications: CE Approved,16 X 2 Dot Matrix LCD Display. Standby battery backup with built in charging. Switch Mode Power Supply.Tactile Keypad for easy panel operation.System ON indication.Low Battery visual warning with audible tone.Fire / Fault status in unambiguous colored LED indication. 2 programmable relays for fire, supervisory and fault.All zones accept smoke detectors and any normally open contact device.Any Zone can be configured as alarm or supervisory.Zone wise isolation and one man walk test facility.Programmable Aux Outputs.Lamp test & Drill test facility. 100 All Events log with RTC.Date / Time / Password configuration.Programmable auto silence facility. Make: Agni/Ravel/Honeywell. |
| 25 | Supply & Fix in repiar Conventional type Sounder Cum strobe with mounting base, continuous normal operation for atleast 50 minutes with sound level 65db- 120db measured at 1.5m with sound output variation +5db complying with the specifications as appended below:-a) Power-12/ 24 V DC or 110 /220V AC, 1Ph, AC, 50Hzb) Range- As applicable.c) visual indication.Make: Agni/Ravel/Honeywell. |
| 26 | Supply & Fix in Replacement of GST Power Supply Card with below specifications for Storage building, mothala: Standard: EN54 Part 2/4 Main Input Voltage: 100-240VAC, 50/60Hz input Current Rating: 0.5A system Operating Voltage: 24 VDC Nominal Loop Capacity: Loop 1: 235; Loop 2: 242Outputs (3): Fire Alarm Output: 500mA /24Vdc/NO-NC F.P.E. Output: 500mA /24Vdc/NO-NC Sounder Circuit Output: 500mA /24Vdc/NO-NC. Make: GST/Agni/Ravel/Honeywell. |
| 27 | Supply & Fix in repiar 2 core 1.5 Sq MM Armoured copper cable for wiring of all the detectors and fire alarm sub-systems. Make: Havells/Polycab/Finolex/RR Kabel. |
| 28 | Supply & fix Intelligent Addressable fire alarm control panel with one Loop complying with EN 54 standard & LPCB approved and battery back up with the specifications as appended below:-a) Power- AC 230V, 50Hz, 0.5 Ab) 235 Devices including detectors, minimum 1 loop,c) Relay- Fire Alarm/ F.P.E/ Fault/ Sounderd) configurable for PC Port- RS-232 interface & communication carde) LCD Display and with battery backup of 24 Hours in non alaram condition and 15 Minutes in alaram condition (Battery type 2 X 12V 14AH, sealed typeMake of Battery- Exide/Amron/Solance. Make of panel: GST. |
| 29 | Supply & Fix electronically addressable intelligent combination of heat and photo electric smoke Multi detector with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:-a) Power- 24V, ≤ 0.8 mA (Standby Current) ≤5.0mA (Alarm Current)b) Class A2R,c) Indicator- Red Flashes in normal and illuminates in alarm,d) Ingress Prote |
| 30 | Supply & Fix electronically addressable intelligent Sounder Cum strobe with mounting base, continuous normal operation for atleast 50 minutes with sound level 65db- 120db measured at 1.5m with sound output variation +5db complying with the specifications as appended below:-a) Power-12/ 24 V DC or 110 /220V AC, 1Ph, AC, 50Hzb) Range-1000 mc) visual indication.Make: Agni/Honeywell/GST. |
| 31 | Supply & Fix intelligent loop isolator with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:-a) Power- 24V, ≤ 3 mA (Standby Current) ≤15mA (Action Current)b) Class A ,c) Initiating Mode- Yellow flashes when polling, illuminates in action,d) Ingress Protection IP-30 & Material-ABSMake: Agni/Honeywell/GST. |
| 32 | Supply & Fix in Replacement of electronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:-a) Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current)b) Class A ,c) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a special Key,d) Ingress Protection IP-43 & Material-ABSMake: Agni/Honeywell/GST. |
| 33 | M & L for software Logic deveplopment for Fire alarm control panel which includes the development of logic for false alarm which comes from Addressable fire alarm control panel and addressing of all the detectors, sounders, MCPs room wise for troubleshooting in alarm condition. Make: Agni/Honeywell/GST. |
| 34 | Supply & Fix Communication card for programming of detectors and other devices in FACP Comm.Interface: USB interfaceComm.Distance <15m <5mBaud Rate 2400bps Ambient Temperature 0℃~+40℃ Relative Humidity ≤95%, non condensing. Make: Agni/Honeywell/GST. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
TodaySep 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysOct 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender