Tender For Electrical Maintenance Contract For Installations Under Cmpdi Exploration C , Gopalpur, Orient Area, Dist.- Jharsuguda, Odisha, For A Period Of 02 Years
Tender Value
20.39 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
9 days left
EMD
25500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jharsuguda → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Maintenance Contract For Installations Under Cmpdi Exploration C , Gopalpur, Orient Area, Dist.- Jharsuguda, Odisha, For A Period Of 02 Years
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for circuit/submain wiring alongwith earth wire with the 2x1.5 sq.mm + 1X1.5 sq.mm of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 2 | Wiring for circuit/submain wiring along with earth wire with 2x2.5 sq.mm + 1x2.5 sq.mm of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 3 | Wiring for circuit/submain wiring alongwith earth wire with 2x4 sq.mm + 1x4 sq.mm of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 4 | Wiring for circuit/submain wiring alongwith earth wire with 2x6 sq.mm + 1x6 sq.mm of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 5 | Wiring for circuit/submain wiring alongwith earth wire with 2x10 sq.mm + 1x6 sq.mm of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 6 | Supplying and fixing of 25 mm size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 7 | Supplying and drawing of 3x1.5 sq.mm FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel / PVC conduit as required. |
| 8 | Supplying and drawing of 3x2.5 sq.mm FR PVC insulated copper conductor single core cable in the existing surface/recessed steel / PVC conduit as required. |
| 9 | Supplying and fixing of 5/6 amps switch on the existing switch box/cover including connections etc. as required |
| 10 | Supplying and fixing Bell push switch on the existing switch box/cover including connections etc. as required |
| 11 | Supplying and fixing of call bell/buzzer suitable for single phase, 230 volts, complete as required. |
| 12 | Wiring for light point / fan point/exhaust fan /call bell point with 1.5 sqmm FRLS PVC insulated,copper conductor, single core cable in surface/recessed steel / PVC conduit , with piano type switch , phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc as required. Group A - 3 mtrs |
| 13 | Wiring for light point / fan point/exhaust fan /call bell point with 1.5 sqmm FR PVC insulated,copper conductor, single core cable in surface/recessed steel / PVC conduit , with piano type switch , phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc as required. Group B - 4 mtrs |
| 14 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required. |
| 15 | Supply and fixing 5A to 32 A rating 240/415V ,10 kA \\"C\\"- curve miniature circuit breaker suitable for inductive load for Single pole in the existing MCB DBs complete with connections , testing , commissioning etc. as required. |
| 16 | Supply and fixing 5A to 32 A rating 240/415V ,10 kA \\"C\\"- curve miniature circuit breaker suitable for inductive load for Single pole and neutral in the existing MCB DBs complete with connections , testing , commissioning etc. as required. |
| 17 | Supply and fixing 5A to 32 A rating 240/415V ,10 kA \\"C\\"- curve miniature circuit breaker suitable for inductive load for Triple Pole and Neutral in the existing MCB DBs complete with connections , testing , commissioning etc. as required. |
| 18 | Supplying, erecting & marking FP MCB 40A to 63A, with rated short- circuit breaking capacity (Icn) 10 kA in provided distribution board as per specification no. SW-MCB |
| 19 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 20 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 21 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 22 | Earthing with GI earth plate 600mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required |
| 23 | Providing servicing of 1.5/2 TR capacity split/ window air conditioning unit complete with all necessary material. Job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indoor as well as outdoor unit and submitting report to Engineer incharge. |
| 24 | Providing vaccumising the air conditioner system and charging with R-22 refrigerant for air conditioning unit |
| 25 | Providing replacement of unserviceable running / Starting capacitor for A/C unit |
| 26 | Supplying and installing of new fan motor for condensor for air conditioning unit |
| 27 | Replacing the existing ball bearing of table/ cabin/ pedestal/ ceiling/ exhaust fan complete with alignment of shaft & testing the same |
| 28 | Replacing the existing bush / rubber with ring and washers of table/ cabin/ pedestal/ ceiling/ exhaust fan complete with alignment of shaft & testing the same. |
| 29 | Rewinding the motor of table / pedestal / wall bracket / cabin fans of all type and makes including minor repairs lubricating of ball bearings & bush bearing, replacing condenser, screws etc. & testing for original speed and consumption with guarantee for 1 year including transportation from site and back. |
| 30 | Rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types and makes and overhauling including minor repairs lubricating of ball bearings & bush bearing, replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year |
| 31 | Rewinding the motor of the exhaust fan 900 / 1400 RPM 300 mm of all types and makes and overhauling including minor repairs, lubricating of ball bearings & bush bearing, replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year |
| 32 | Supplying and erecting integrated LED street light fitting 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG ODF/SL |
| 33 | Supplying and erecting 12 V/80Ah to 88 Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete |
| 34 | Supply and fixing of 10 watt LED tube light batten (make wipro ,bajaj ,philips or equivelent.) |
| 35 | Supply and fixing of 20 watt LED tube light batten (make wipro ,bajaj ,philips or equivelent.) |
| 36 | Supply and fixing of R06 type (AA), 1.5V Battery |
| 37 | Supply and fixing of R03 type(AAA), 1.5V Battery |
| 38 | Supply and fixing of PVC board of 7\\"x4\\" sizes with backelite sheet on top. |
| 39 | Supply and fixing of PVC board of 8\\"x6\\" sizes with backelite sheet on top. |
| 40 | Supply and fixing of bolted fuse links (16 A to 32 A) |
| 41 | Supply and fixing of fuse holders 32 Amp. |
| 42 | Electrician for maintenance - comprising of Electrical fault rectification, Generator operation, etc. ( detailed scope provided in NIT) by deployment of two electrician with valid wireman licence per shift for two shifts per day . |
| 43 | Servicing and Maintenance of DG set 1 x 5 KVA - Air Filter |
| 44 | Servicing and Maintenance of DG set 1 x 5 KVA - Fuel filter pre element |
| 45 | Servicing and Maintenance of DG set 1 x 25 KVA - Lub Oil Filter element |
| 46 | Servicing and Maintenance of DG set 1 x 5 KVA - Lub oil 20Ltr Pack |
| 47 | Servicing and Maintenance of DG set 1 x 5 KVA - belt |
| 48 | Servicing and Maintenance of DG set 1 x 5 KVA - packing & forwarding charges |
| 49 | Servicing and Maintenance of DG set 1 x 5 KVA - Servicing of DG set such as replacement of spares, tuning and adjustment & testing |
| 50 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer