Tender For Repair And Rehabilitation Of Electrical Installations Work To Administrative Building Of Chief Construction Engineer, Anandapur Barrage Project At Salapada In The District Of Keonjhar
Tender Value
13.43 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
9 days left
EMD
13500
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kendujhar → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Rehabilitation Of Electrical Installations Work To Administrative Building Of Chief Construction Engineer, Anandapur Barrage Project At Salapada In The District Of Keonjhar
BOQ
| Sl. No. | Item Description |
| 1 | S/I/ T&Commissioning of LT indoor floor mounted cubical type electrical Block panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with bus bar should be installed. All the feeders shall have ON/OFF/ TRIP panel board including component list. 50X5MM Separate Aluminium Earth indication. Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P. MCB. C series, 10kA is to be given in the incomer including all taxes excluding GST. |
| 2 | Incomer 1- 400 Amp, 4P MCCB with ROM 36kA with LSIG microprocessor release with Ics-100% Icu. (Make- Legrand-DPX3/ Siemens-3VA Model Schneider CVS/ ABB Formula) with shunt trip.with axulary for BMS, One(1) set of 400/ 5A, 15VA, CL 1.0, CT with 3 Nos Phase indicating lamps with control fuse/ MCB. (with required other accesories.)Incomer 2- 250A 4P MCCB with ROM 25kA with adjustable Thermal Magnetic Release with Ics 100% Icu. (Make- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula) with shunt trip.with axulary for BMS One(1)- Multifunction digital meter suitable for three phase four wire system, unbalanced loading CL 1.0, flush mounting with Voltage, Current, pf. KW, KWH, KVA, KVAr, KVAh, KVArHr. One (1) COS-250 Amp, 4P Onload changeover switch with required Relay and accessories. The ATS must have manually operated mechanism.Busbar- 400 Amp Al busbar suitable for operation at 415 Volt, 50 Hz, 3 Phase Supply. 50X5MM Separate Aluminium Earth bus bar should be installed.Outgoing Feeders -7 Nos (5 nos for Floor Power DB Panel & 2No Spare) each comprising of One (1) 125A 4P MCCB with ROM 25kA with adjustable Thermal Magnetic Release with Ics 100% Icu. (Make- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula) with shunt trip.with axulary for BMS One Set ON/ OFF Indicating lamp with control fuse/ MCB with required other accesories.Outgoing Feeders -7 Nos (5 nos for Floor Light DB Panel & 2No Spare) each comprising of One (1)-63A 4P MCCB with ROM 16kA with adjustable Thermal Magnetic Release with Ics 100% Icu. (Make- Legrand-DPX3/ Siemens-3VA Model/Schneider- CVS/ ABB Formula) with shunt trip.with axulary for BMS One Set ON/OFF Indicating lamp with control fuse/ MCB with required other accesories.Outgoing Feeders for (4Nos spare) each Comprising of One (1) -63A FP 10KA MCB, C Series Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB200 with required other accesories.Outgoing Feeders for (8Nos spare) each Comprising of One (1) -63A DP 10KA MCB, C Series Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB200 with required other accesories.PANEL AS ABOVE DB, MCB, RCCB & AFDD including all taxes excluding GST. |
| 3 | Supplying and fixing of following mentioned way, three pole single pole and shall be as per IEC 61439-3,integrated door cathing system offering neutral, sheet steel,double door MCB distribution board, 415 volts/ 240 volts additional safety to the user, High quality polyurethane Gasket the box and cover shall be fabricated to withstand IK09, the DB should be properly pre-treated with 7 tarik process and duly powder coated, phosphatized with powder coated finish, on surface/ recess, complete with terminal Blocks with suitable size FR PVC insolated copper conducter us to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make- Legrand-Ekinox 3 DB/ Siemens-Betaguard/ Schneider Acti 9 ABB FTUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years including all taxes excuding GST. |
| 4 | 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming 1-8 modules, sub incommer-12 module & out going-12 modules, suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet. IP43-IK09 with metal door Warranty on DB is 3 years (FOR LDB) including all taxes excluding GST. |
| 5 | 8 Way(8+(4x3)+(3x8)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming 1-8 modules,sub incommer-12 module & out going-24 modules, suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet. IP43-IK09 with metal door Warranty on DB is 3 years (FOR PDB) including all taxes excluding GST. |
| 6 | Supplying and fixing 6-32 Amps rating, C series, 10KA breaking capacity, SP, 230 volts, MCB. Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year including all taxes excluding GST. |
| 7 | Supplying and fixing 32 amps rating, 240 volts, C series, 10KA breaking capacity, Double poles MCB of Make-Legrand-DX3/Siemens-Betaguard/Schneider- Acti 9/ ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. Warranty on MCB is 1 years including all taxes excluding GST. |
| 8 | Supplying and fixing 40 amps rating, 415 volts, C series, 10KA breaking capacity, FOUR poles MCB of Make- Legrand-DX3/ Siemens-Betaguard/Schneider- Acti 9/ ABB SB200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. Warranty on MCB is 1 year including all taxes excluding GST.. |
| 9 | Supplying and fixing 40 Amps rating, 4P 415 volt, RCCB 30mA. Make-Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The RCCB should be Replacement Warranty will be 1 year including all taxes excluding GST. |
| 10 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series, 10KA breaking capacity, Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB200 in the existing MCB DB with connections as per direction of Engg.-in-Charge. Warranty on MCB is 1 years including all taxes excluding GST. |
| 11 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3/Siemens-Betaguard/Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.. The MCB should be Replacement Warranty will be 3 years including all taxes excluding GST. |
| 12 | Supplying and fixing of Type (I+II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) us 7kA/ POLE and 25kA total and nanosec in the incommer of Distribution board, Make Legrand Siemens/maximum discharge current Imax(8/20) msec-50kA with response time 25 Schneider/OBO/ DEHN in the existing MCB DB with connections as per direction of Engg.-in-Charge. The SPD should have Replacement Warranty will be 1 year including all taxes excluding GST. |
| 13 | SUB MAIN WIRING |
| 14 | Recessed wiring for circuit/ submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make-Finolex/ Anchor/ Polycab/Havells/RR Kabel/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/ Precision/Norpak Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit (LDB to SB) (2X2.5+1X1.5) including all taxes excluding GST. |
| 15 | Recessed wiring for circuit/ submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make-Finolex/ Anchor/ Polycab/ Havells/ RR Kabel/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make- AKG/BEC/Precision/Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit. (PDB to PSB/AC POINT) (2X6+1X2.5) including all taxes excluding GST. |
| 16 | Receass wiring for circuit/ submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/ Havells/ RR Kabel/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit (FP TO LDB) (4X6+2X2.5) including all taxes excduding GST. |
| 17 | Receass wiring for circuit/ submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/Havells/ RR Kabel/ KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/ Precision/Norpak/Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 40 mm dia non metallic heavy duty conduit. (FP TO PDB) (4X10+2X6) including all taxes excluding GST. |
| 18 | CABLESCables supplySupplying & Testing of 1.1 KV grade Aluminium XLPE power cable of following size suitable for 415 Volt, 3Ph, 50 c/ s supply. (Make:- Polycab/Havells/KEI/Gloster/ Finolex/RR Kabel) including all taxes excluding GST. |
| 19 | 4.3 4C X 16 sqmm including all taxes excluding GST. |
| 20 | 3.5C X 95 sqmm including all taxes excluding GST. |
| 21 | CABLE LAYING |
| 22 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade of following size direct in ground including excavation (75) cm), sand cushioning,protective covering and refilling the trench etc as required Upto 25 sq. mm including all taxes excluding GST. |
| 23 | Laying of One No. PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing On Wall Surface(Clamped with saddle/ PVC & UPVC Pipe)/ CableTray as required including all taxes excluding GST. |
| 24 | Upto 25 sq. mm including all taxes excluding GST. |
| 25 | Above 25 sq. mm and upto 120 sq. mm including all taxes excluding GST. |
| 26 | TERMINATION OF CABLESSupply & Making end Termination with brass double compression gland and Cu/ aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable) (Make: Raychem/ M-seal/3M) including all taxes excluding GST. |
| 27 | 4C X 16 sqmm including all taxes excluding GST. |
| 28 | 3.5C X 95 sqmm including all taxes excluding GST. |
| 29 | square/round shape 18 W LED luminaire of dimension of consists of white powder coated, die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens,, CRI not less than 80,CCT of 6000 degree K, THD less than 10%, with electronic driver, internal surge protection of 3 KV, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro /Crompton/ Bajaj). The luminaire should be Replacement Warranty will be 5 including all taxes excluding GST. |
| 30 | S/F of 60 watt LED Street Light fittings (Make- Havells/ CGj/ Phillips/ Jaquar/ Panasonic/ Equivalent) including all taxes excluding GST. |
| 31 | Earthing |
| 32 | Supplying, installation, testing & commissioning of materials and installation of GI earth plate 600mm x 600mm x 6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, 3 water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge including all taxes excluding GST. |
| 33 | Providing and fixing 25 mm X 5 mm dia G.I strip on wall/ surface With required DMC insulator and nut bolt connection etc. as required including all taxes excluding GST. |
| 34 | Providing and fixing 50 mm X 5 mm dia G.I strip on wall/ surface With required DMC insulator and nut bolt connection etc. as required including all taxes excluding GST. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysSep 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender