Drinking Water Supply and Sanitation Government Departments Closing in 9 days TDR #57459740

Tender For Construction Of C-Type Quarter For Chief Construction Engineer Of Khairibhandan And Deo Irrigation Project At Deo Irrigation Colony, Karanjia.

Issued by Government Departments · Mayurbhanj, Odisha
Tender Value
94.71 Lakhs
Estimated cost
Bid Submission
25 Sep 2026
9 days left
EMD
94800
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mayurbhanj → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of C-Type Quarter For Chief Construction Engineer Of Khairibhandan And Deo Irrigation Project At Deo Irrigation Colony, Karanjia.

BOQ

Name of Work:- Construction of C-type Quarter for Chief Construction Engineer of Khairibhandan and Deo Irrigation Project at Deo Irrigation Colony, Karanjia.
Sl. No. Item Description
1Earth work in excavation of foundation trenches in all kinds of soil including moorum stoney earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and leveling the bed upto the required depth and depositing the excavated materials away from the work site with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Hire & Running charges of the water pumps, Sundries, T & P required for the work complete but excluding GST as directed by the Engineer- in- charge.
2Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional antitermite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. but excluding GST as directed by the Engineer -in -charge.
3Filling in foundation trenches and plinth with excavated earth well watered and rammed in layers not exceeding 23 c.m in depth including all lead and lift, cost of all labour, sundries, T&P required for the work etc. complete in all respect but excluding GST as directed by the Engineer- in- charge.
4Supplying & Filling foundation trenches , plinth & ditches with river sand well watered and rammed in layers not exceeding 23 c.m in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and taxes of all Materials, cost of all Labour,Sundries, T&P required for the work etc. complete in all respect but excluding GST as directed by the Engineer- in -charge. (Measurement will be taken on finished compacted section only.)
5Providing and Laying Plain Cement Concrete of proportion (1:3:6) in foundation and floors (i.e. below the base course of the flooring) using 40 mm size crusher broken H.G Stone Metal free from weathered skins , cement and screened & washed sharp river sand for mortar of approved quality & from approved quarry including hoisting, lowering and laying concrete to the required level, ramming, watering & curing etc complete to required levels, laid in layers not exceeeding 15cm thick in each layer including cost, conveyance , loading,unloading, stacking ,royalties and taxes of all materials, cost of all labour, Sundries, T&P required for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of the water pump required for the work etc complete in all respect but excluding GST as directed by the Engineer-in-charge.
6Providing Fly Ash Brick Masonry using bricks of size 25 c.m. x 12 c.m. x 8 c.m. having crushing strength not less than 75 kg per square c.m. in cement mortar of mix (1:6) with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in the works in Foundation & Plinth of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,scaffolding, sundries and T&P required for the works etc. complete in all respect but excluding GST as directed by the Engineer-in-charge.
7Providing Fly Ash Brick Masonry using bricks of size 25 c.m. x 12 c.m. x 8 c.m. having crushing strength not less than 75 kg per square c.m. in cement mortar of mix (1:6) with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in the works in superstructure and similar such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,scaffolding, sundries and T&P required for the works etc. complete in all respect but excluding GST as directed by the Engineer-in-charge. (7.01-Ground Floor)
8First Floor
9Providing Fly Ash brick masonry using Fly Ash bricks of size 23 c.m. x 11 c.m. x 8 c.m.having crushing strength not less than 75 kg per square c.m in cement mortar of mix (1:4) (for half brick masonry wall) with provision of 2 nos of 6mm. dia M.S. Round Reinforcement bars at each 4th layers) with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth, basement and for ornamental flower beds, plinth moulding and similar such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, royalties and taxes of all materials ,cost of all labour, sundries, T&P required for the works etc. complete but excluding GST in all respect as directed by the Engineer-in-charge.(8.01-Ground floor)
10First Floor
11Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 grade , as per approved designs and drawings having a minimum compressive strength ( in work test) 250Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips( of required quantities) from weathered skins of approved quality & from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P but excluding GST as per direction of Engineer-incharge. ( 9.01- Foundation)
12Plinth beam
13Column in Superstructure (Ground Floor)
14First Floor
15LINTELS (Ground Floor)
16First Floor
17CHAJJA AND SILL PROJECTION (Ground Floor)
18First Floor
19STAIRCASES (Ground Floor)
20ROOFSLAB (Ground Floor)
21First Floor
22Roof Slab Beam (Ground Floor)
23First Floor
24Cutting, Straightening coiled or bent up HYSD / TMT Reinforcement Bars of Fe 500 welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing Fan Hooks where necessary and hoisting, lowering and placing the same in proper position according to the approved designs and drawings in all floors at all height including cost, coveyance, loading, unloading ,stacking & taxes of HYSD/ TMT Reinforcement Bars and Binding Wires of 18 to 20 Gauge as required for the work , cost of all Labour ,Sundries, T&P,Staging and Scaffolding complete in all respect but excluding GST as directed by Engineer-in-charge. (Payment will be made according to the actual / proper weight of the HYSD / TMT Reinforcement Bars & Binding Wires consumed in the particular work only) . (10.01- Ground Floor)
25First Floor
2616 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the rough surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete etc. but excluding GST as directed by the Engineer- in -charge. (11.01-Ground Floor)
27First Floor
2812 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the even surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete etc. but excluding GST as directed by the Engineer- in -charge.(12.01-Ground Floor)
29First Floor
306 m.m thick cement plaster in cement mortar of mix (1:4) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking and taxes of all Materials, cost of all Labour,Sundries, T&P, Scaffolding,Watering, Curing etc. complete in all respect but excluding GST as directed by the Engineer- in- charge. (13.01-Ground Floor)
31First Floor
3225 mm. thick Grading Concrete of proportion (1:2:2) on top of the Roof Slab using approved quality of cement, 6 mm. size hard crusher broken granite stone chips with screened & washed sharp sand for mortar of approved quality from approved quarry, washed & cleaned, free from all debrises and silt along with providing a layer of waterproofing treatment by using pedicrete (URP/SBR) Latex before grading concret (Mix - Latex @ 0.54 Ltr/Sqm & Cement @ 0.008Qntl /Sqm) including hoisting, lowering and laying concrete in all floors at all height after chipping, chiseling and cleaning the entire roof surface by using wire brush, finished smooth to proper required slope and gradient including cost, conveyance, royalties, loading, unloading,stacking and taxes of all Materials, cost of all Labour, T &P, Sundries, Watering ,Curing etc.required for the work complete in all respect but excluding GST as directed by the Engineer-in-charge.(sika/pidilite/equivalent) . (14.01 -Ground Floor)
33First Floor
34Providing Chequered Tile Flooring using Chequered Tile (25mm thick) of approved quality, colour and size in floors at all height on 25 m.m thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened & washed sharp river sand for mortar ,grouted with neat cement slurry joining the Ultra Designer Tile with neat cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Ultra Designer Tile if required (Tiles are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T&P required for the work , Watering, Curing for required days, including rubbing and wax polishing etc. complete in all respect but excluding GST as directed by the Engineer-in-charge.
35Providing , Fitting & Fixing Anti-Skid Ceramic Floor Tiles in flooring using special plain / printed series Anti-Skid Ceramic Floor Tile of premium grade ( having minimum thickness 7 mm to 8 mm & size 300 m.m x 300 m.m OR 400 m.m x400 m.m) confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings in all floors at all height on 25 m.m thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry, joining the Anti-Skid Ceramic FloorTiles with neat white cement slurry,mixed with required (Tiles are to be immersed in the water for required time before use) quantities of pigments of approved marks to match the shades of the Anti-Skid Ceramic FloorTiles if required including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect but excluding GST as directed by the Engineer-in-charge. (16.01-Ground Floor)
36First Floor
37Supplying, Fitting & Fixing Ceramic Glazed Wall Tiles in Dados Skirting and Riser of Steps using approved shade,quality and size of Ceramic Glazed Wall Tiles (having thickness of 6.5 mm to 6.7 mm & 300 mm X450.mmsize) confirming to IS.13753 in proper position in all floors at all heights on 12 mm. thick cement plaster (1:3) using screened and washed sharp river sand for mortar with cement, grounted with neat cement slurry and jointed with neat cement mixed with required approved shade of pigment to match the shade of the Ceramic Glazed Wall Tiles (Tiles are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading,stacking, royalties and taxes of all Materials, cost of all Labour, Curing, Sundries and T&P, etc. required for the work complete but excluding GST as directed by the Engineer-in-charge. (17.01-Ground Floor)
38First Floor
39Providing, Fitting and Fixing minimum 8 m.m to 10 m.m thick double charge Vitrified Tile in flooring using vitri Tile in flooring using vitrified Tile of approved quality, colour and size (600 mmx 600 mm coloured printed series homogeneous) in floors , treads on steps landings in all floors at all height on 25 m.m thick bed of cement mortar of mix(1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry joining the Vitrified Tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Vitrified Tile if required (Tile are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials , cost of all Labour , sundries, T&P required for the work, Watering, Curing for required days including cleaning the flooring space but excluding GST as directed by the Engineer-in-charge. (18.01-Ground Floor)
40First Floor
41Providing, Fitting & Fixing of 8 mm. to 10mm. thick Vitrified Tile (of size 600mm.x600mm.) of approved make confirming to specifications having minimum breaking strength 1400 kg/sq.cm in dados skirting and riser of steps in all floors at all height on 12m.m thick cement mortar (1:3) to proper slope , line and level including cutting to required size and shape ,fixing at corners and splays etc. including filling the joints with silicon sealant to match the shade of Vitrified Tile as per the design & drawing including cost, conveyance, loading , unloading , stacking, royalties and taxes of all materials, cost of all labour, T&P , sundries , watering & curing etc. required for the work complete in all respect but excluding GST as directed by the Engineer-in-charge. (19.01-Ground Floor)
42First Floor
43Providing and fixing factory made single extruded WPC wood polymer composite doors , windows and other frame with high density rigid solid wood polymer composite of 0.7 DWPC foam sheet ,mitre cut at two corners abd joined and the two vertical door profile are to be reinforced to horizontal member .The door frame shall be fixed to the wall using 6nos 150mm long M.S holdfastners through the frame by using etc. complete but excluding GST as per manufacturers specification and direction of Engineer -in -charge. ( 20.01- Ground Floor size(125mmx65mm)
44Ground Floor Toilet (85mm x45mm)
45First Floor size(125mmx65mm)
46First Floor Toilet (85mm x45mm)
47Supply and fixing doors as per drawing with WPC solid 3layer and ISI marked door shutter of 30 mm thick single shutter with bond wood solid block board type of 0.7 D WPC sheet incluiding cost of convinience to site of WPC shutter incluiding supplying and fixing cost of ISI mark alluminium fixtures of 3 nos. butt hinges ( IS: 205) 150 mm long , one number of aldrop ( IS: 2681) 300 mm long, one number of tower bolt (IS: 204) of 200 mm x 10 mm dia at top , two numbers 150 mm long handles ( IS : 208) , one number door stoper and one number rubber / nylon door stop bushes incluiding fixing the fixtures to doors with required number of screws, bolt and nuts incluiding labour charges for fixing the frame in position, fixing the shutter to the frame etc. incluiding over head and contractor profit but excluding GST as per direction of Engineer -in -charge. (21.01- Ground Floor)
48First Floor
49Providing, fitting, fixing UPVC windows( sliding type) including providing stainless steel hinges, locking arrangement and other requisite fittings and fixtures including cost, coveyance, loading, unloading and taxes of all materials,cost of all labour,scaffolding, staging, sundries and T&P required for the works etc. complete in all respect as per approved drawing,design & specification but excluding GST as directed by the Engineer-in-charge all complete. (Fenest/ Wintek make). (22.01-Ground Floor)
50First Floor
51Supplying , fitting and fixing of unplasticised poly vinyle chloride ( UPVC ) (FENESTA/ VEKA LTD) ventilator top hang 60 series duly manufactured using upvc reinforced profile of 60 mm x 55 mm x 2.5 mm outer frames, 75 mm x 60 mm x 2.25 mm for casement window sash profile capable of mounting single glazing system , structurally reinforced with hot dip galvanised upto 50 micrones of minimum thickness of 1.5 mm prefabricated and welded so through fusion welding the window sash shall be fitted with 6 mm thick clear toffen glass of saint Gobain make duly fixed with EPDM weathering seal resistance accessories like cliping locking system made of alluminium one number per set shases and the system is to be instalised at the site using anchoring fastner silicon rubber sealant, easy glazing/ deglazing at the site incluiding cost of convinience of all materials, accessories, labour charges , materials and product conferming to ASDM D 638-14, EN-477-95 and other applicable codes and standardsand direction of Engineer -in -charge but excluding GST. (23.01-Ground Floor)
52First Floor
53Frosted Glass 12mm thickness Balcony Railing Supplying, Fitting and Fixing of Stainless Steel of 304 grade in Handrail using 50mm dia of 2mm thick circular pipe with stainless steel balustrade of size 32 m.m x 32 m.m x 2 m.m @ 0.90mtr.centre to centre and stainless steel square pipe bracing of size 32m.m x 32m.m x 2m.m in 3 (Three) rows in stair case and at required places as per approved Drawings, Design and Specification,welding, buffing, polishing etc with cost, conveyance,loading,unloading ,stacking & taxes of all materials,cost of all labour, T&P etc. required for the work complete in all respect in all floors at all height but excluding GST as directed by the Engineer-in charge. (24.01-First Floor)
54Supplying, Fitting and Fixing of Stainless Steel of 304 grade in Handrail using 50mm dia of 2mm thick circular pipe with stainless steel balustrade of size 32 m.m x 32 m.m x 2 m.m @ 0.90mtr.centre to centre and stainless steel square pipe bracing of size 32m.m x 32m.m x 2m.m in 3 (Three) rows in stair case and at required places as per approved Drawings, Design and Specification,welding, buffing, polishing etc with cost, conveyance,loading,unloading ,stacking & taxes of all materials,cost of all labour, T&P etc. required for the work complete in all respect in all floors at all height but excluding GST as directed by the Engineer-in charge. (25.01-Ground Floor)
55Supplying, Fitting and Fixing M.S Grills of approved designs made out of M S Square bars etc. of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming of approved quality metallic primer, making required holes in Massonary Walls / R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Massonary Walls / R.C.C Structures including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, staging, scaffolding, sundries, T&P etc. complete but excluding GST as per the direction of the Engineer-in-charge.( Weight to be taken properly prior to fixing the grills in the works and payment to be made accordingly ) (26.01-Ground Floor)
56First Floor
57Painting 2(two) or more coats with premium quality exterior emulsion paint (weather shield max ) of approved Brand/Quality & colour on the finished external plasterd surface using required quantities of paint by the concerned manufacturer to give an even shade over a coat of primer in all floors at all height, watering the surface before applying the Weather Coat paint and curing for the required period including cost , onveyance, loading , unloading , stacking, royalties and taxes of all materials, cost of all labour, T&P , sundries , watering & curing etc. required for the work complete in all respect but excluding GST as directed by the Engineer-in-charge. (27.01-Ground Floor)
58First Floor
59Finishing surface of interior walls with premium quality interior acrrylic emulsion paint over a coat of wall priming of approved make and finished smooth & even surface with two coats of wall putty to receive painting in all floors at all height including cost, coveyance, loading , unloading ,stacking and taxes of all Materials, cost of all Labour, Sundries ,Scafffolding ,Staging and T&P etc. required for the work complete in all respect but excluding GST as directed by the Engineer-in-charge. (28.01-Ground Floor)
60First Floor
61Painting with synthetic enamel paint of approved colour, shade and brand like ICI/ Asian/ Berger on Steel work / New wood work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete but excluding GST as directed by the Engineer-in-charge. (29.01-Ground Floor)
62First Floor
63Providing Plinth Protection of 600 m.m Width all around the plinth area of the proposed building with an under layer of 75m.m thick Plain Cement Concrete of proportion (1:4:8) using 40mm size hard crusher broken black granite stone metal compacted over a consolidated rigid ground and top of 50m.m thick Cement Concrete of proportion (1:2:4) with 12mm size hard crusher broken black granite stone chips laid to proper slope and gradient and top to be finished smooth with 12mm thick cement plaster in C.M(1:4) and protected the edges with 1st class K.B.brick massonary walls ( using the K.B Bricks of crushing strength not less than 75Kg/Sqcm) (half brick masonry 125mm deep) in Cement Mortar (1:6) including execution of required earth work, cost , conveyance, loading, unloading,royalities & taxes of all materials, cost all labour,Sundries, T&P, watering, curing etc complete in all respect but excluding GST as directed by the Engineer-in-charge.
64Providing minimum 20 m.m thick Granite Slab Flooring using approved quality, shade and size of Granite Slab above 0.40sqm specially in floors, treads on steps and landings in all floors at all height on 25 m.m thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry joining the Granite Tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Granite Tile if required including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T&P required for the work , Watering,Curing for required days including rubbing mechanically and wax polishing etc. complete in all respect as directed by the Engineer-in-charge.(31.01-Ground Floor)
65Supplying,Fitting & Fixing minimum 20mm.Thick Granite slab in Dadoos Skirting using approved shade,quality and size of Granite slab of 10mm.Thick above 0.40 sqm) in all floors at all heights on 12 m.m thick cement plaster (1:3) using screened & washed sharp river sand for mortar with cement, grouted with neat white cement slurry and jointed with neat white cement slurry mixed with required approved shade of pigment to match the shade of the Granite slab including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour,Watering, Curing,Sundries and T&P, etc. required for the work complete but excluding GST as directed by the of Engineer-in-charge. (32.01-Ground Floor)
66Providing edge moulding to 18 mm /20mm thick marble stone/Granite counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete but excluding GST as per design approved by Engineer-in-Charge. (33.01-Ground Floor)
67Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (DSR 2014 Item No. 22.5 converted OSR-2014) but excluding GST as directed by the Engineer-in-charge. (34.01-First Floor)
68Providing and filling AAC block inside the sunken floor with all cost, conveyance, taxes transportation loading, unloading etc complete but excluding GST as directed by the Engineer-in-Charge. ( 35.01-First Floor) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57459740
AUTHORITY Government Departments
TENDER VALUE 94.71 Lakhs
LAST DATE 25-09-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Construction Of C-Type Quarter For Chief Construction Engineer Of Khairibhandan And Deo Irrigation Project At Deo Irrigation Colony, Karanjia.
Basic Detail
Tender No 03/SEDHWD/2026-27
Bidding Type Tender
Location
City Mayurbhanj
State Odisha
Key Dates
Publish Date 11 Sep 2026
Submission Date 25 Sep 2026
Open Date 28 Sep 2026
Finance
Tender Value 94.71 Lakhs
Tender Fee 10000
EMD 94800
Exemption Available
Document List
0d0579e4-b95f-4157-9fe7-9b3f9c01326d.html
BidCType.pdf
BOQ_609131.xls
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

0d0579e4-b95f-4157-9fe7-9b3f9c01326d.html

pdf

BidCType.pdf

xls

BOQ_609131.xls

pdf

Tendernotice_1 (19).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender