Tender For Development Of Potable Water Supply And Sanitation Facility At Mahakali Pitha Complex (Religious Tourist Site) At Village Kharod Under Baramba Block Inthe District Of Cuttack.
Tender Value
1.41 Crore
Estimated cost
Bid Submission
28 Sep 2026
14 days left
EMD
1.50 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cuttack → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Development Of Potable Water Supply And Sanitation Facility At Mahakali Pitha Complex (Religious Tourist Site) At Village Kharod Under Baramba Block Inthe District Of Cuttack.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation in open well in all kinnds of Soil within 50mtr initial lead and 1.5mtr initial lift including rough dressing and breaking of clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3mtr in depth as per direction of Engineer-in-charge.1st depth of 1.50 mtr. |
| 2 | Earth work excavation in open well in stoney earth and gravel mixed with stone and boulders not exceeding 0.14cum in volume within 50mtr initial lead and 1.5mtr initial lift including rough dressing and breaking of clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3mtr in depth as per direction of Engineer-in-charge. 2nd depth of 1.50 mtr. (upto 3.0 mtr.) |
| 3 | 3rd depth of 1.50 mtr. (upto 4.5 mtr.) |
| 4 | 4th depth of 1.50 mtr. (upto 6.0 mtr.) |
| 5 | 5th depth of 1.50mtr. (upto 7.5 mtr.) |
| 6 | 6th depth of 1.50 mtr. (upto 9.0 mtr.) |
| 7 | 7th depth of 1.50 mtr. (upto 10.5 mtr.) |
| 8 | Supplying of all labour T & P matrials for rough stone dray massonary on guard wall and well retaing walls including all cost, coveyance royalty etc. all complete. |
| 9 | Supplying of all labour T & P matrials for filling 12 mm chips around dry stone masonary walls including all cost, coveyance royalty etc. all complete. |
| 10 | Supplying of all labour T & P materials etc. for rigid smooth centering shuttring for R.C.C. walls including all cost conveyance etc.all complete. |
| 11 | Supplying fitting and fixing & placing un coated HYSD bar rainforcement complete as per drawing and technical specification unit IMT taking out put 1 MT HYSD bar 5% overlaping & wastages. ( To be Paid as per actual |
| 12 | Providing all materials labour T & P etc, for R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusher broken) stone chips including hoisting and laying, lead, royality conveyance etc. all complete. |
| 13 | Supplying of all labour, T & P, matrials etc for fitting and fixing & placing in position of 20 mm dia Round Bar for Step inside well etc. all complete and as per the direction of Engineer In Charge. 20 mm dia Round bar Step Iron |
| 14 | Providing all labour T&P etc for Refilling in foundation and plinth with excaveted earth or materials .etc. all complete and as per the direction of Engineer In Charge. |
| 15 | Providing all labour T&P etc for hire charges of diesel pump with diesel, consumable,operator etc all complete. (To be paid as per actuals.)5 HP Diesel Pump 2 nos x 40 days x 5 hours daily |
| 16 | 6mm. Thick cemet plaster (1:4) per 1Sqm |
| 17 | Cement washing 1 coat over cement plastering |
| 18 | Wall painting two coats with plastic emulsion paint of approved shade on new work to give an even shade inculding cost of paint. |
| 19 | Earth work in all kinds soil within 50m.Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction Engineer-in-charge. |
| 20 | Providing all materials, labour, T&P etc. for Sand filling in all cost,conveyance,royalty etc.all complete.and as per the direction of the Engineer in charge. |
| 21 | Supplying of all labour T & P materials etc. for rigid smooth centering shuttring for R.C.C. walls including all cost conveyance etc. to complete. |
| 22 | Providing all materials, labour, T&P etc.for Supplying ,fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification. for R.C.C. works and as per the direction of the Engineer in charge. (0.20 Qtl/cum) |
| 23 | Providing all materials, labour, T&P etc.for Metal concrete (1:3:6) with 25mm.size broken hard granite chips including hoisting , laying and all cost,conveyance,royalty etc.all complete.and as per the direction of the Engineer in charge. |
| 24 | Providing all materials, labour, T&P etc.for 12 mm. thick cement plaster (1:4) for stone work including all cost,conveyance, royalty etc.all complete. and as per the direction of the Engineer in charge.(out side) |
| 25 | Providing all materials,labour,T&P etc.for Finishing walls with water proofing cement paint of approved shade on new work two coat to give an even shade inculding cost of cement paint with 1 coat of white washing etc.all complete.and as per the direction of the Engineer in charge. |
| 26 | Earth work in excavation of foundation in all kinds of soil with in initial lead of 50mtr and initial lift of 1.50mtr including rough dressing and levelling the bed as per the direction of Engineer in charge. |
| 27 | Supplying all materials ,labour,T&P for filling in foundatin and plinths with sand well watered and rammed including cost, carriage & royality of all materials etc. all complete & as per direction of Engineer in charge |
| 28 | Cement concrete (1:3:6) with 4cm size hard granite stone including cost, conveyance and royality etc |
| 29 | Cement concrete (1:1.5:3)) with 12 mm size C.B.H.G. chips for RCC work including hoisting & laying with cost conveyance, royality of all materials to site |
| 30 | Rigid and smooth centering and of materials complete in ground floor shuttering for R.C.C. works including false works and dismantling them after casting including cost. conveyance, royality etc.R.C.C. foundation , plinth band and footings bases of columns mass concrete slab etc |
| 31 | R.C.C. floor and roof slabs, landings, balconies, projecting sun shades and chajjas upt 4.30 m height |
| 32 | R.C.C. beams, column, grider and bressmer, etc. |
| 33 | Supplying all labour, T&P and material for cutting, bending, binding, straighting and laying in position M.S. rods cluding cost of binding wire and cost of MS rods as per the dirction of Engineer-in-charge. |
| 34 | Providing cement paint two coats to walls with good quality paint including all cost. |
| 35 | Supplying, all labour T&P,earthwork in excavation in foundation & plinth in all kinds of soil with in 50m initial lead & 1.5m initial lift including rough dressing & breaking clods to max. 5cm to 7cm laying in layers not exceeding 0.3min depth & as per directon of engineer-in-charge of the department. |
| 36 | Supplying all materials ,labour,T&P for filling in foundatin and plinths with sand well watered and rammed including cost, carriage & royality of all materials etc. all complete & as per direction of Engineer in charge |
| 37 | Supplying all labour, T&P materials providing cement concrete (1:3:6) with 40 mm size CBHG metal including hosting & laying cost, conveyance and royalty of materials etc. all complete as per directon of engineer-in-charge of the department. |
| 38 | Supplying all labour, T&P materials providing RCC work of M-20 grade with 20mm & down grade black hard granite crusher broken stone chips including hosting & laying cost, conveyance and royalty of materials etc. all complete as per directon of engineer-in-charge of the department. . |
| 39 | Supplying all labour T&P rigid & smooth Centering & Shuttering for RCC Works including false work & dismantling then after casting including cost of materials etc all complete in ground floor as per directon of engineer-in-charge of the department.. R.C.C. foundation , plinth band and footings bases of columns mass concrete pre-cast slabs etc |
| 40 | R.C.C. beams, column, grider and bressmer, etc. |
| 41 | Roof slab &chajja |
| 42 | Supplying all materials labour, T&P for cutting, bending binding & straightening & tying the grill and placeing in position includig cost of HYSD reforcement bar and binding wire 18 to 20 gauge etc all complete as per direction of E.I.C. |
| 43 | Supplying all labour T&P materials providing brick work with Fly ash bricks (25cm x 12cm x 8cm) size in cement mortar (1:6) as per directon of engineer-in-charge of the department.. |
| 44 | Supplying of all materials,labour and T&P for providing MS doors/windows/grills including supplying all fittings |
| 45 | Labour for fitting and fixing of M.S. Doors & Windows as per approved design including cost of all materials complete. |
| 46 | Supplying all labour, T&P materials providing 12mm thick cement plastering in C.M (1:6) including cost conveyance & royalty of materials etc. all complete as per directon of engineer-in-charge of the department. |
| 47 | 6 mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment. |
| 48 | Supplying all materials, labour and T&P for fixing tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete excluding cost of precast tiles (Ceramic Tiles)as per direction of Engineer-in-charge. |
| 49 | Supplying all labour, T&P materials fixing tiles in dados, skirting and risers of stepson 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigmentstone match the shade of the tiles including rubbing and polishing etc all completeas per direction of Engineer-in-charge. |
| 50 | Supplying all labour, T&P, materials providing painting two coats on new Ms/wood works with approved enamel paint including cost of paint. |
| 51 | Painting two coats with weather coat of approved shade on new work to give an even shade inculding cost of paint. |
| 52 | Distempering two coats to walls with distemper of approved shade on new work to give an even shade inculding cost of distemper. |
| 53 | Supplying all labour, T&P materials for writing information at wall of pump house display board etc. all complete as per direction of engineer in charge. |
| 54 | CONSTRUCTION OF COMPOUND WALL (1place): Earth work in exacavation for foundation in all kinds of soil with initial lead and lift including dressing and levelling the bed. |
| 55 | Filling in foundatin and plinths with sand watered and rammed (Labour only) |
| 56 | P.C.C(1:4:8) with 4cm. Size CBHG metal in F&P including cost, conveyance and royalty etc. complete. |
| 57 | Brick work with Fly ash bricks (25cm x 12cm x 8) cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±8 percent with all labour T&P etc complete. |
| 58 | In Super Structure with CM (1:4) |
| 59 | Fillig in foundation and plinth with excavated earth includig watering and ramming. |
| 60 | Cement concrete (1:2:4)with 12mm size hard broken granite chips & Dry cleancoarse River Sand per 1cum (DPC) |
| 61 | Supplying MS gate including cost of fabrication, all taxes etc. complete. |
| 62 | Fitting and fixing of MS Grill gate. |
| 63 | 12mm thick cement plaster in CM (1:6) over brick masonary including cost,lead,royality. |
| 64 | Providing weather coat paint two coats to walls with good quality paint including all cost. |
| 65 | Painting two coats with approved paint on new wood /MS work including cost of paint |
| 66 | CONSTRUCTION OF COMPOUND WALL (1place): Earth work in exacavation for foundation in all kinds of soil with initial lead and lift including dressing and levelling the bed. |
| 67 | Filling in foundatin and plinths with sand watered and rammed (Labour only) |
| 68 | Fillig in foundation and plinth with excavated earth includig watering and ramming. |
| 69 | P.C.C(1:4:8) with 4cm. Size CBHG metal in F&P including cost, conveyance and royalty etc. complete. |
| 70 | Brick work with Fly ash bricks (25cm x 12cm x 8) cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±8 percent in cement mortar (1:6) in F/P. |
| 71 | In Super Structure with CM (1:4) |
| 72 | Supplying fitting & placing uncoated HYSD bar reinforcement complete as per drawing & techinical specification. |
| 73 | Rigid & smooth centring & shuttering for R.C.C. work including false works and dismantling then after casting including cost of materials cmplete in ground floor . |
| 74 | Brick work with Fly ash bricks (25cm x 12cm x 8) cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±8 percent with all labour T&P etc complete. |
| 75 | Supplying MS gate including cost of fabrication, all taxes etc. complete. |
| 76 | Fitting and fixing of MS Grill gate. |
| 77 | 12mm thick cement plaster in CM (1:6) over brick masonary including cost,lead,royality. |
| 78 | Providing weather coat paint two coats to walls with good quality paint including all cost. |
| 79 | Painting two coats with approved paint on new wood /MS work including cost of paint |
| 80 | Electric driven Horizontal submersible pump set(SD) of 3-phase having Head of 56 mtr & Discharge 9.67 LPS, Kirloskar, KSB, LUBI make. (with 100 % Stand by) (5 HP) |
| 81 | Supplying ,installing commissionig & testing of ISI marked Motor control panel board suitable for above pump set with suitable volt meter & Ampere meter (if not in the control pannel volt meter & Ampere meter will be fitted separately). 1set as stand by. |
| 82 | 25 Sq. mm Armoured 4 core Aluminium cable reputed make FINOLEX / HAVELS / BCH / ANCHOR ( ISI Marked ) |
| 83 | 10 Sq. mm copper Submersiable flat cable reputed make like KSB / FINOLEX / HAVELS / BCH / ANCHOR ( ISI Marked ) |
| 84 | M.S. Angle frame with suitable nut & bolt with painting including Painting. |
| 85 | Double ended Flanged GI Pipe of 80 mm dia.each 3.00 mtr. Long D/F of medium quality with required nut, bolt, rubber insertion. |
| 86 | 80 mmX 900 G.I bend D/F of size 0.60 mtr Length |
| 87 | 80x150 mm both side flanged G.I tapper of 0.40 mtr. Length.. |
| 88 | Supplying all labour T&P for lowering of pump and motor into intake well up to the required depth including jointing to rising main, cable jointing with required materials & cost of transportation to site etc. all complete as per direction of Engineer in charge. |
| 89 | Electric driven Horizontal submersible pump set(SD) of 3-phase having Head of 75 mtr & Discharge 4.48 LPS, Kirloskar, KSB, LUBI make. (7.5 HP) |
| 90 | Supplying , installing commissionig & testing of ISI marked (SD) Control panel board suitable for above pump set with suitable volt meter & Ampere meter ( If not in the control pannel volt meter & Ampere meter will be fitted separately). 1set fitted as stand by. (7.5 HP to 10 HP) BCH/T&C/L&T/C&S/CG |
| 91 | 25 Sq. mm Armoured 4 core Aluminium cable reputed make FINOLEX / HAVELS / BCH / ANCHOR ( ISI Marked ) |
| 92 | 10 Sq. mm copper Submersiable flat cable reputed make like KSB / FINOLEX / HAVELS / BCH / ANCHOR ( ISI Marked ) |
| 93 | M.S. Angle frame with suitable nut & bolt with painting including Painting. |
| 94 | Double ended Flanged GI Pipe of 50 mm dia.each 3.00 mtr. Long D/F of medium quality with required nut, bolt, rubber insertion. |
| 95 | 80 mmX 900 G.I bend D/F of size 0.60 mtr Length |
| 96 | 80x150 mm both side flanged G.I tapper of 0.40 mtr. Length.. |
| 97 | Supplying all labour T&P for lowering of pump and motor into intake well up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge. |
| 98 | INTERNAL ELECTRIFICATION TO PUMP HOUSE - 3 PHASE Providing all materials labour T&P and Surface wiring to light point fan point with ISI marked 1.5 &2.5 insulator wire and PVC 5AMP Switch from board sunmika plate and all connection complete. (Concealed) |
| 99 | Surface wiring / Concealed 5 AMP plug fuse,indicator, with ISI marked 1.5 & 2.5 mm multi stain PVC copper wire PVC pipe from board complete. |
| 100 | Provision of 200 AMP Kit Kat including all taxes with fitting, fixing, testing at site. |
| 101 | Provision of Board with Volt Meter, Amp Meter, Selector Switch, Pilot Lamp, Indicator etc. including all taxes with fitting, fixing, testing at site. |
| 102 | Provision of PVC sheeted insulted 7/16 copper wire etc. including all taxes with fitting, fixing, testing at site |
| 103 | Provision of Bulket Complete Set etc. including all taxes with fitting, fixing, testing at site . |
| 104 | Provision of MS angle Stand frame for TPN Main Switch, panel Board Starter fixing in wall etc. all complete. including all taxes with fitting, fixing, testing at site. |
| 105 | Provision of 32 AMP Main Switch including all taxes with fitting, fixing, testing at site. |
| 106 | Provision of Tube light complete set. including all taxes with fitting, fixing, testing at site. |
| 107 | Provision of all materials for earthing complete set. including all taxes with fitting, fixing, testing at site. |
| 108 | Provision of all materials 36 Watt CFL full fitting with Nut bolt and Angle pipe etc all complete. including all taxes with fitting, fixing, testing at site. |
| 109 | Provision of 95 mm2 Copper Socket. including all taxes with fitting, fixing, testing at site. |
| 110 | Provision of 200 AMP TPN Main Switch 400/440 Volt including all taxes with fitting, fixing, testing at site. |
| 111 | RISING MAIN & DISTRIBUTION SYSTEM Supplying of all materials, labour, T&P etc for Earth work in all kinds of soil within 50mtrs. Initial lead and 1.50mtr. Initial lift including rough dressing and breaking clods to maximum 5 Cm to 7 Cm and laying in layers not exceeding 0.30 mtr. in depth including levelling and dressing the bed of foundation.as per direction of engineer in charge. |
| 112 | Supplying of all materials, labour, T&P etc for Filling in foundation and plinth with excavated materials including watering and ramming as of respective item of work directed by the Engineer-in-charge. |
| 113 | Supplying of all materials, labour, T&P etc for Laying in trenches High Density Polyethylene pipes conforming to IS: 4984/1985 and specials of following outside diameter and Class- I to Class-3 and jointing by fusion welding method including testing as per specification complete. ( Earth work in trenches to be measured separately).160 mm HDPE pipe (PN 6.0) (PE 80 Grade) |
| 114 | 110 mm HDPE pipe (PN 10) (PE 100 Grade) |
| 115 | 90 mm HDPE pipe (PN 6.0) (PE 80 Grade) |
| 116 | Supplying all labour ,materials & T&P for fitting & fixing of C.I. sluice valve ,N R Valve & Air valve of aproved make with supplying all materials etc all complete.150 mm dia sluice valve |
| 117 | 100 mm dia sluice valve |
| 118 | 80 mm dia sluice valve |
| 119 | 100 mm dia NR valve |
| 120 | Air valve 25mm |
| 121 | Supplying , Fabricating pressing in position of required Dia GI Pipe of 5mm Thick confirming to IS:3589 of the following diameter as per specificationcomplete. ( including all cost of special) Source, OGR to OHT Rising Main Distribution main pipe. 150 mm dia G.I pipe ( M ) |
| 122 | 100 mm dia G.I pipe ( M ) |
| 123 | Culvert crossing & road crossing. 150 mm dia G.I pipe ( M ) |
| 124 | 100 mm dia G.I pipe ( M ) |
| 125 | 80 mm dia G.I pipe ( M ) |
| 126 | Flame cutting of GI pipe,welding of mm GI flange including cost of flange,machining & grinding etc. complete as per specification & direction of Engineer-in-charge. (For 1 joint)150 mm dia GI pipe |
| 127 | 100 mm dia GI pipe |
| 128 | 80 mm dia GI pipe |
| 129 | Flame cutting of GI & jointing both ends by welding inluding cost of machining & grinding etc. complete as per specification & direction of Engineer-in-charge. (For 1 joint)150 mm dia GI pipe |
| 130 | 100 mm dia GI pipe |
| 131 | 80 mm dia GI pipe |
| 132 | Supplying all labour ,materials labour & T&P for construction of R C C sluice valve /N R Valve/AV chamber as per approved drawing design & specification. |
| 133 | Supplying all labour ,materials labour & T&P for construction of single mouth stand post as per approved drawing design & specification. |
| 134 | Supplying of all labour,T&P,materials including taxes for cutting CC roads for taking pipelines all. complete as per direction of the Engineer in charge. (After the permission granted from the department then road cutting should be done ) |
| 135 | Supplying of all labour,T&P,materials including taxes for making good to the damages of C.C Road in C.C (1:2:4) all. complete as per direction of the Engineer in charge |
| 136 | Supplying all labor T&P for Const. of Display Board |
| 137 | CONST. OF 100 KL ESR : Supplying of all labour,T&P,material for soil testing ,supply of design, drawing , construction, errection, testing & commissioning etc. of RCC elevated storage reservoir of 100 KL capacity with necessary staging height of 15.00 mtr consisting of 6 nos RCC column and spherical dome using R.C.C M-25 , 4 nos ISI marked 100 mm dia CI sluice valve, 1 no of 100 mm dia NR valve & it's Brick masonary valve chambers as per approved drawing, supplying, fitting & fixing of 100 mm dia GI pipe(M) of Tata/Jindal make confirming to IS specification of required length from Production well/ Perculation well/Intake well/UGR to ESR & ESR to distribution main including in-let, out-let, over flow & washing line ( double flanged GI column pipe) of ESR, RCC stair case with structural GI(M) pipe hand rail around dome and landing etc. and GI(M) ladder inside and outside the ESR, lightening arrester confirming to IS specification, water level indicator, 100 mm dia CI puddle collar, 0.60 m dia CI manhole cover at dome , RCC vent with SS brass jally etc. all complete and as per direction of the Engineer - in- Charge. (The contractor shall execute the work after preparing the design and detail drawing in 5 sets from qualified engineer and to approve all structural design & drawing from State Technical Agency(STA) IGIT, Saranga / CET, BBSR / VSSUI, Burla / NIT, Rourkela / IIT, BBSR at his own cost). |
| 138 | CONST. OF 200 KL UGR/OGR : Supplying of all labour,T&P, material for soil testing , supply of design, drawing , construction, erection, testing & commissioning etc. of RCC 200 KL. ltrs RCC UGR capacity spherical dome using R.C.C M-25 , 2 nos ISI marked 150 mm dia CI sluice valve 1 no, & it's NRV valve chambers as per approved drawing, supplying, fitting & fixing of 150 mm dia medium grade GI pipe confirming to IS 1239 (P-1) 2004, IS 1978 and IS 3598 of required length with required specials from risingmain to UGR & UGR to ESR distribution main including GI(M)TATA/JINDAL in-let, out-let, over flow & washing line( double flanged GI(M) column pipe) of OGR, RCC landings with 32mm size GI(M) hand rail around dome and landing etc. and GI (M) ladder up to top and outside the UGR, and GI (M) ladder inside the UGR, lightening arrester confirming to IS specification,water level indicator, 150 mm dia CI puddle collar, 0.60 m dia CI manhole cover at dome , RCC vent with SS / brass jally etc. all complete and as per direction of the Engineer - in- Charge. (The contractor shall execute the work after preparing the design and detail drawing in 5 sets from qualified engineer and to approve all structural design & drawing from State Technical Agency (STA) IGIT, Saranga / CET, BBSR / VSSUI, Burla / NIT, at his own cost ) |
| 139 | The contractor shall Operate & maintain the PWS project for Five (5) calendar years from the completion date of defect liability period of one year in such a manner that all the house hold of the PWS Scheme covered area will get (adequate) required quantity of supply water taking supply hour as 8hour/day without facing any problem.The contractor shall repair and replace any types of defect arise within 24 hr of receipt of complaint either from public or from Department . The contractor shall maintain all structure of the PWS schemes as per terms and conditions of DTCN & technical specification mentioned in Section-5. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysSep 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender