Defence Statutory Bodies & Commissions/Committees Closing in 29 days TDR #57459345

Tender For Replacement Of Defective 415Volt Lt Main Distribution Panel & 415 V Lt Main Distribution Board, Street Light Incoming Cables, Main Incoming Power Cables And Circuit Wirings At Officers Club Of Ordnance Factory Badmal.

Issued by Statutory Bodies & Commissions/Committees · Balangir, Odisha
Tender Value
27.49 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
29 days left
EMD
55000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Balangir → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Defective 415Volt Lt Main Distribution Panel & 415 V Lt Main Distribution Board, Street Light Incoming Cables, Main Incoming Power Cables And Circuit Wirings At Officers Club Of Ordnance Factory Badmal.

BOQ

Name of Work:- Replacement of Defective 415Volt LT Main Distribution Panel & 415 V LT Main Distribution Board, Street Light Incoming Cables, Main Incoming Power Cables and circuit Wirings at Officers Club of Ordnance Factory Badmal.
Sl. No. Item Description
1Replacement of Defective 415Volt LT Main Distribution Panel & 415 V LT Main Distribution Board, Street Light Incoming Cables, Main Incoming Power Cables and circuit Wirings at Officers Club of Ordnance Factory Badmal.
2Laying of one number of PVC insulated and PVC sheathed power cable of 1.1 KV grade of size upto 35 Sq. MM direct in ground including excavation, sand cushioning, protective covering with dry clay/fly ash bricks and refilling the trench etc. as required.
3Laying of one number of PVC insulated and PVC sheathed power cable of 1.1 KV grade of size above 35 Sq. MM and upto 95 sq.mm direct in ground including excavation, sand cushioning, protective covering with dry clay/fly ash bricks and refilling the trench etc. as required.
4Laying of one number of PVC insulated and PVC sheathed power cable of 1.1 KV grade of size above 95 Sq. MM and upto 185 sq.mm direct in ground including excavation, sand cushioning, protective covering with dry clay/fly ash bricks and refilling the trench etc. as required.
5Supplying & making end termination with brass compression gland and aluminium lugs for 3 Core 16 Sq. MM (25 MM) PVC Insulated and Sheathed aluminium conductor cable of 1.1 KV grade as required.
6Supplying & making end termination with brass compression gland and aluminium lugs for 3.5 Core 50 Sq. MM (35 MM) PVC Insulated and Sheathed aluminium conductor cable of 1.1 KV grade as required.
7Supplying & making end termination with brass compression gland and aluminium lugs for 3.5 Core 150 Sq. MM (50 MM) PVC Insulated and Sheathed aluminium conductor cable of 1.1 KV grade as required.
8Earthing with GI earth pipe 4.5 metre long, 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
9Supplying & fixing cable route marker with 10 cm x 10 cm x 5 mm (+/- 5%) thick GI plate with inscription there on, bolted/welded to 35 mm x 35 mm x 6 mm (+/-5%) angle iron, 50-60 cm long and fixing the same in the ground as required.
10Supplying & fixing 5/6 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make: Anchor/Poly Cab/V-Guard/Legrand/Cona.
11Supplying & fixing 3 pin 5/6 A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make: Anchor/Poly Cab/V-Guard/Legrand/Cona.
12Supplying & fixing 15/16 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make: Anchor/Poly Cab/V-Guard/Legrand/Cona.
13Supplying & fixing 6 pin 15/16 A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make: Anchor/Poly Cab/V-Guard/Legrand/Cona.
14Supplying & fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
15Supplying and fixing of 12 module (200 mm x 150 mm) GI box along with modular base & cover plate for modular switches in recess etc. as required. Make: Anchor/Poly Cab/V-Guard/Legrand/Cona.
16Supplying and fixing of 2 module (75 mm x 75 mm) GI box along with modular base & cover plate for modular switches in recess etc. as required. Make: Anchor/Poly Cab/V-Guard/Legrand/Cona.
17Supplying and fixing of 3 module (100 mm x 75 mm) GI box along with modular base & cover plate for modular switches in recess etc. as required. Make: Anchor/Poly Cab/V-Guard/Legrand/Cona.
18Supplying & fixing 3 pin, 5A ceiling rose on the existing junction box/wooden block including connections etc. as required. Make: Anchor/Poly Cab/V-Guard/Legrand/Cona or equivalent.
19Wiring for light point/fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessd with medium class PVC conduit or casing caping as per requirement, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Make: Anchor/Poly Cab/V-Guard/Cona/KEI/RR.
20Wiring for circuit/sub-main along with 2 x 6 sq.mm (For Phase & Neutral) + 1 x 6 sq.mm (For earth wire) with PVC insulated single core copper conductor of FRLS grade, in recess/surface in medium class PVC conduit as required. Make: Anchor/Poly Cab/V-Guard/Cona/KEI/RR.
21Material & Labour for point wiring with FRLS single core copper conductor cables of size 2.5 sq.mm in PVC conduit for one 3 pin 5 amps socket outlet independent .Cutting chases for concealed conduit wiring will be measured separately. The rate do not include supply & fixing of electric fittings & accessories such as ceiling roses, lamp holders, socket outlets, switches, call bells etc. The wiring material to be used shall be of ISI marked & of reputed make like Havells, V-Guard, Polycab, Finolex, Anchor, Cona, KEI, RR Cables.
22Material & Labour for point wiring with FRLS single core copper conductor cables of size 4 sq.mm in PVC conduit for one 3 pin 15 amps socket outlet independent .Cutting chases for concealed conduit wiring will be measured separately. The rate do not include supply & fixing of electric fittings & accessories such as ceiling roses, lamp holders, socket outlets, switches, call bells etc. The wiring material to be used shall be of ISI marked & of reputed make like Havells, V-Guard, Polycab, Finolex, Anchor, Cona, KEI, RR Cables.
23Cutting chases for concealed conduit wiring with cutting not exceeding 10 cm girth & making good with cement mortar 1:3 & paint as required.
24M & L for 100 MM Bore Dia Galvanised Tubes of Light Grade with all fittings Laid in Trenches.
25Supplying & laying of 40 mm dia low density polyethelene (LDPE) of pressure rating 6kgf/cm2 fixed complete to walls, ceiling or in floors etc.
26Labour for demolition of cement concrete or black bituminous hard standing of any description and in any position not otherwise specifically provided.
27Material & Labour for cement concrete of type C2 (1:3:6) with 40 mm graded aggregate in making cable trenches for power cable.
28Labour for excavating in hard/ dense soil not exceeding 1.5 m wide & not exceeding 1.5 m depth for construction of earth pit and getting earth out.
29Labour for excavating trenches in hard/ dense soil not exceeding 1.5 m wide & exceeding 1.5 m depth for construction of earth pit and getting earth out.
30Labour for returning the excavated earth in trench including spreading, levelling & well ramming in layers not exceeding 25 cm.
31M & L for rigid non metallic PVC junction boxes of 1 to 4 way with external dia of 32 mm as per requirement.
32Supply, fixing, testing and commissioning of FRP Street Light Marshalling Box of Size- 200 mm X200 mm x 125 mm with tolerance of +/-10mm. The marshalling box shall be fitted on pole of dia approx. 146-150 mm with two nos. of GI clamp with suitable nut, bolt and washers. The above marshalling box shall have one no. of 6 A MCB fitted on DIN rail and 4 Nos. of insulators fitted inside for termination of 3 core armoured aluminium conductor of size 16-25 Sq. mm. It shall have hole for bottom cable entry and out. It shall have door locking facility as well as proper gasket as rain water will not enter inside the box. Test certificate for IP 65 or better to be provided during the commissioning of material. It also includes removal of old existing marshalling boxes from pole.
33SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 415V, 50HZ, Indoor Type Floor Mounting LT PANEL FABRICATED OUT OF 2 MM THICK MS SHEET FOR LOAD BEARING PART & 1.6 MM THICK SHEET FOR OTHER BODY PART, DULY POWDER PAINTED, ALUMINIUM BUS BAR FOR THREE PAHSE & NEUTRAL WITH CURRENT CARRYING CAPACITY OF 800A, 1 NO. OF 500 AMP MCCB FOR INCOMER, 2 NOS. 160 A MCCB FOR OUTGOING FEEDER, 4 NOS. OF 125 AMP MCCB FOR OUTGOING FEEDER, 6 NOS. OF 100 AMP MCCB FOR OUTGOING FFEDER, R-Y-B LED INDICATOR FOR INCOMER AND ON, OFF, TRIP LED INDICATOR FOR ALL OUTGOING MCCB FEEDER. MFM WITH KWH, PF, V, A ETC. IN INCOMER & SUITABLE CABLE ALLEY FOR CABLE MOVEMENT AND TERMINATION, DETACHEABLE GLAND PLATE AT BOTTOM. ALL MATERIALS TO BE USED SHALL BE OF ISI MARKED OR CONFORMING TO RELEVANT IS STANDARDS. THIS INCLUDES REMOVAL OF EXISTING LT PANEL AND RE-APPROPRIATION OF TRENCH TO INSTALL NEW LT PANEL AT THE SAME POSITION. TYPE TEST CERTIFICATE ISSUED FROM NABL OR ANY CENTRAL GOVT. LABORATORY TO BE SUBMITTED BEFORE COMMISSIONING OF PANEL.HOWEVER, PANEL TO BE FABRICATED IN COMPLIANCE WITH IS: 8623 OR OTHER RELEVANT. IT INCLUDES ALL SWITCH GEARS LIKE MCCB/MCB, MFM ETC.INDOOR TYPE PANEL, IP 42 OR BETTER PROTECTION. APPROX. SIZE: 2700 MM (W) X 1800MM (H) X 600 MM (D).
34SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 415V, 50 HZ, Indoor Type Recess Mounting MAIN DISTRIBUTION BOARD FABRICATED OUT OF 2 MM THICK MS SHEET, DULY POWDER PAINTED, COPPER BUS BAR FOR THREE PHASE & NEUTRAL WITH CURRENT CARRYING CAPACITY OF 200A, 4 NOS. OF 40 A DIN RAIL MOUNTED DP MCB TO BE PROVIDED IN EACH PHASE FOR OUTGOING CIRCUIT & 1 NO. OF 125 AMP, FP MCCB TO BE PROVIDED AS INCOMER, R-Y-B LED INDICATOR FOR INCOMER, SEPARATED COMPARTMENT FOR EACH PHASE OUTGOING FEEDER WITH SEPARATE EARTH BAR, DETACHEABLE GLAND PLATE AT BOTTOM FOR INCOMER & AT SIDE & TOP FOR OUTGOING FEEDER. ALL MATERIALS TO BE USED SHALL BE OF ISI MARKED OR CONFORMING TO RELEVANT IS STANDARDS. THIS INCLUDES REMOVAL OF EXISTING DISTRIBUTION PANEL AND RE-APPROPRIATION OF WALL CUTTING TO INSTALL NEW DISTRIBUTION PANEL AT THE SAME POSITION. TYPE TEST CERTIFICATE ISSUED FROM NABL OR ANY CENTRAL GOVT. LABORATORY TO BE SUBMITTED BEFORE COMMISSIONING OF DISTRIBUTION PANEL. HOWEVER, PANEL TO BE FABRICATED IN COMPLIANCE WITH IS: 8623 OR OTHER RELEVANT. THIS INCLUDES ALL SWITCH GEARS LIKE MCCB/MCBs & OTHER ACCESSORIES AS REQUIRED. APPROX. SIZE: 1000 MM (W) X 1000MM (H) X 200 MM (D).
35SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 415V, 50 HZ, OUT DOOR TYPE STAND MOUNTING DOUBLE DOOR FEEDER PILLAR PANEL FABRICATED OUT OF 2 MM THICK MS SHEET, DULY POWDER PAINTED, AL. BUS BAR FOR THREE PHASE & NEUTRAL WITH CURRENT CARRYING CAPACITY OF 500-630 A, 3 NOS. OF 40 A DIN RAIL MOUNTED DP MCB & 1 No. of 40 A RCCB TO BE PROVIDED IN EACH PHASE FOR OUTGOING CIRCUIT & 1 NO. OF 400 AMP, FP MCCB TO BE PROVIDED AS INCOMER, R-Y-B LED INDICATOR FOR INCOMER, SEPARATED COMPARTMENT FOR EACH PHASE OUTGOING FEEDER WITH SEPARATE EARTH BAR, DETACHEABLE GLAND PLATE AT BOTTOM FOR INCOMER & AS WELL AS FOR OUTGOING FEEDER. ALL MATERIALS TO BE USED SHALL BE OF ISI MARKED OR CONFORMING TO RELEVANT IS STANDARDS. THIS INCLUDES REMOVAL OF EXISTING DISTRIBUTION PANEL AND RE-APPROPRIATION OF WALL CUTTING TO INSTALL NEW DISTRIBUTION PANEL AT THE SAME POSITION. TYPE TEST CERTIFICATE ISSUED FROM NABL OR ANY CENTRAL GOVT. LABORATORY TO BE SUBMITTED BEFORE COMMISSIONING OF DISTRIBUTION PANEL. HOWEVER, PANEL TO BE FABRICATED IN COMPLIANCE WITH IS: 8623 OR OTHER RELEVANT. THIS INCLUDES ALL SWITCH GEARS LIKE MCCB/MCBs & OTHER ACCESSORIES AS REQUIRED. APPROX. SIZE INCL. STAND: 1200 MM (W) X 2000MM (H) X 500 MM (D).
36Supply, fixing, testing and commissioning of LED rope/strip light along with electronics driver suitable to glow each segment, connector/plug & fixing accessories. The LED strip/rope will be of single colour and may require different colours LED strip/rope to meet functional requirement. The operating voltage will be 230 V AC, 50 Hz. 40 to 60 Numbers of LEDs shall be present in each meter of LED strip/rope.
37Supply, fixing, testing and commissioning of Round Shaped 50 Watt +/-10%, 230 V, 50 Hz, LED Stage Focus Light along with electronics driver, connector/plug & fixing accessories. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57459345
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 27.49 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Munitions India Limited
Work Description Tender for Replacement Of Defective 415Volt Lt Main Distribution Panel & 415 V Lt Main Distribution Board, Street Light Incoming Cables, Main Incoming Power Cables And Circuit Wirings At Officers Club Of Ordnance Factory Badmal.
Basic Detail
Tender No 3012/OFBL/RD2609/TE-09-2026-27
Bidding Type Tender
Location
City Balangir
State Odisha
Key Dates
Publish Date 10 Sep 2026
Submission Date 12 Oct 2026
Open Date 15 Oct 2026
Finance
Tender Value 27.49 Lakhs
Tender Fee Ref. Documents
EMD 55000
Exemption Not Available
Document List
008ba942-ba0a-410d-b484-c0c35d7c9cb6.html
1-BiddersComplianceforTE-_1.xls
2-IMPORTANT-NOTE-CIVIL-EL_2.pdf
3-Indemnity-Bond.pdf
4-Remedial-Measure-of-Saf_3.pdf
BOQ_338742.xls
ScopeofWork.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 29 days
Oct 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 32 days

Tender Documents

Download All (ZIP) ↓
html

008ba942-ba0a-410d-b484-c0c35d7c9cb6.html

xls

1-BiddersComplianceforTE-_1.xls

pdf

2-IMPORTANT-NOTE-CIVIL-EL_2.pdf

pdf

3-Indemnity-Bond.pdf

pdf

4-Remedial-Measure-of-Saf_3.pdf

xls

BOQ_338742.xls

pdf

ScopeofWork.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders