Tender for Tender for Under The Electricity Distribution Division, Muradnagar, The Work Of Shifting 02 33 Kv Electric Poles In Khasra No. 947 Of Village Mehrauli And 33 Kv, 11 Kv Ht Line And Pole In Village Alupur Under The Full Deposit Scheme.
Tender Overview
Project Description
Tender for Under The Electricity Distribution Division, Muradnagar, The Work Of Shifting 02 33 Kv Electric Poles In Khasra No. 947 Of Village Mehrauli And 33 Kv, 11 Kv Ht Line And Pole In Village Alupur Under The Full Deposit Scheme.
BOQ
| Sl. No. | Item Description |
| 1 | Carriage of line material from Electricity Store Center, Modinagar to site of work with loading and unloading at both ends on Kachha Packka road Like Earth Rod 05 Nos, Ms Channel 66 KG., MS Angle 66 Kg,Cable Box O/D 11 KV 3x185 Sq mm-6 Nos.,GI Wire-15 Kg, Stay Wire-32 Kg, Stay Set-8 Nos. 33 KV Pin Insulator-18 Nos, 33 KV Cross Arm- 6 Nos. |
| 2 | Carriage of Cable HT XLPE 11 KV 3x185 Sq MM from Electricity store center, Modinagar/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road. |
| 3 | Carriage of ACSR Dog Conductor from Electricity store center, Modinagar to site of work with loading and unloading at both ends on Kachha Packka road. |
| 4 | Carriage of PCC Pole 11 Mtr Long . from Electricity store center, Modinagar to site of work with loading and unloading at both ends on Kachha Packka road. |
| 5 | Carriage of PCC Pole 8.5 Mtr Long . from Electricity store center, Modinagar to site of work with loading and unloading at both ends on Kachha Packka road. |
| 6 | Carriage of STP Pole 13 Mtr Long from Electricity store center, Modinagar to site of work with loading and unloading at both ends on Kachha Packka road. |
| 7 | Providing & Erection of Paint of Poles Red Oxide Paint |
| 8 | Providing & Erection of Paint of Poles Aluminium Paint |
| 9 | Erection & Fixing of PCC Pole 11 mtr. long in 33 KV line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/Norms by providing F-Bracket made of M.S. Flat of size 50x6 mm, Cross Arm holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts. |
| 10 | Erection & Fixing of STP Pole 13 mtr. long in 33 KV line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/Norms by providing F-Bracket made of M.S. Flat of size 50x6 mm, Cross Arm holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts. |
| 11 | Erection & Fixing of PCC Pole 8.5 mtr. long in 11 KV line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/Norms by providing F-Bracket made of M.S. Flat of size 50x6 mm, Cross Arm holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts. |
| 12 | Laying of Cable 11 KV XLPE Cable Underground/Open Cut Method with Sand & Bricks Spare Cable shall be in the loop Shape at both ends as per RESPO |
| 13 | Laying of Cable 11 KV XLPE Cable Overhead Spare Cable shall be in the loop Shape at both ends as per RESPO |
| 14 | Making and filling of 11KV Cable Jointing Kit, Indoor/outdoor type, after duly plumbing and taping of suitable XLPE Cable, providing, fixing and crimping of proper size good quality lugs, including cost of lugs and tape etc., as per RESPO Norms. |
| 15 | Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing/Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops. |
| 16 | Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts. |
| 17 | Grouting of ST/PCC supports in CC 1:4:8 (Cement, sand & 40mm brick ballast) Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials. |
| 18 | Wrapping of barbed wire on 33/11KV ST/PCC poles as anti-climbing device for a length of 0.9mtrs. Wire pitch/gap 13mm and fixing upper and lower end keeping lower end at a hieght of 2.75 mtr from the ground complete, including providing & fixing of lower end & upper end clamps made of M.S. Flat 40X5mm complete with nuts & bolts and all other required material and T&P. |
| 19 | Laying , Stringing and final sagging of ACSR Dog Conductor after binding from Insulator, as per RESPO/Drawing Norms. |
| 20 | Providing & Fixing of G.I. pipe 6\\"dia Class-B over 11KV XLPE cable before mounting the cable at double pole. The work includes fitting of clamps, sealing of top and bottom of pipe and one end of pipe is to be burried under earth about 500mm earch including mounting and clamping the cable on double pole structure and making connection with overhead line at both ends. |
| 21 | Providing & Erection of MS Holding Clamps With Nut & Bolt |
| 22 | Providing & Fixing of Danger Board, including fixing of all accessories by providing all required materials (like suitable clamps, nuts & bolts etc.) as per RESPO/Drawing Norms. |
| 23 | Providing & Fixing of Number Plate alongwith all required accessories (like suitable clamps, nuts & bolts etc.) as per RESPO/Drawing Norms. |
| 24 | Dismantling & Removal of old existing STP/PCC pole after digging of pit and opening of all accessories |
| 25 | Removal of old & used ACSR Conductor and opening form insulator and bundling of the same. |
| 26 | Carriage of old & used STP/PCC from site of work to store center with loading and unloading at both ends. |
| 27 | Carriage of old & used ACSR Conductor and opening form insulator and bundling of the same. |
| 28 | Jumpering work properly as per RESPO/Norms. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender