Tender For Special Repair To Bldg No. P-42 (Cook House) At Umroi Mil Stn Under Ge Umroi
Tender Value
41.80 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
22 days left
EMD
83600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ri Bhoi → Meghalaya
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Bldg No. P-42 (Cook House) At Umroi Mil Stn Under Ge Umroi
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkats or frames exceeding 1.50 sqm but not exceeding 4.00 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed |
| 2 | Taking down chowkats or frames not exceeding 1.50 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 3 | Taking down shutter of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each complete all as specified and directed. |
| 4 | Supply and fixing aluminium anodised (powder coated) three track sliding window frame with shutters with ( 2 Nos glazed and one wire gauzed shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete and glazing with and including 4 mm thick plain glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc including aluminium grill of thickness 5mm and opening not exceeding 75mmx75mm etc with the following section of frame and shutter complete all as specified and directed:-(a) Sections for shutter:- (i) 'H' section: 39 x 20 x 1.20 mm thick (ii) 'Interlock' section: 39 x 20 x 1.20 mm thick(iii) 'Edge & Bottom' section: 41 x 20 x 1.20 mm thick (b) Section for frame:-(i) Top & Sides: 92 X 29.50X 1.20mm thick (ii) Bottom: 92 X 29.70 X 1.20mm thick |
| 5 | Supply and fixing aluminium anodised (powder coated) ventilator frame (section for frame 63.5 X 38.1 X 1.20mm thick) with shutter(section for shutter 41 x 20 x 1.2mm thick)(bottom half portion fixed and top half portion with louver) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete and glazing with and including 4 mm thick frosted glass to aluminium frame work and louver using rubber gasket and fixed with stainless steel wire cloth of 0.36 mm dia and average width of aperture 1.40 mm outside vent with staple and suitable wall angle of size 25.4 x 25.40 x 1.1mm thick and fillets with screws and washers etc including Deco Grill of Model / Design No. DG 104 and 6.3mm thick etc. complete all as specified and as directed. |
| 6 | S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed single side prelamaminated PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelamaminated sheet complete all as specified and directed. |
| 7 | Supply and fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppyling & fixing in the frame at site as per specification & drawing, etc complete all as specified and as directed. |
| 8 | S&F Pressed steel frames for doors of frame size 105x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and directed.Note: Filling of hollow portion of frames with PCC shall be measured and paid separately. |
| 9 | S&F Pressed steel frames for doors of frame size 125x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and directed.Note: Filling of hollow portion of frames with PCC shall be measured and paid separately. |
| 10 | Material & Labour for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in filling of pressed steel frame complete all as specified and as directed. |
| 11 | Material & labour for PCC type B0 1:2:4 (12.5mm graded stone aggregate) for fixing hold fasts, angle, etc including necessary form work complete all as specified and directed. |
| 12 | S & F mild steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 13 | S&F 100 mm long butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 14 | S&F 35 mm thick factory made second class hard wood plain framed panelled shutter (two panel) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rails and style as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 15 | S&F second class hard wood 35mm glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) and fitted to chowkhats complete all as specified and directed. |
| 16 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 17 | Supply and fixed stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks, or stainless steel wire staples including all cuttings, wastage etc, complete all as specified and directed. |
| 18 | S&F 150 mm long extruded aluminium alloy handles, fabricated type, anodized complete all as specified and directed. |
| 19 | S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 20 | S&F 100 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 21 | S & F in repairs 20mm dia tubular curtain rod, brass chromium plated including brass chromium plated brackets for curtain rod of any size complete all as specified and directed. |
| 22 | S&F 300 mm long aluminium alloy, anodised sliding door bolt with hasp and staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy and fixed complete all as specified and directed. |
| 23 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons, walls etc, laid, bedded and pointed in any mortar complete all as specified and directed. |
| 24 | M&L for machine cut kota stone slab flooring 18-20 mm thick over and including 20mm thick cement screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick screed bed/bedding layer in cement mortar 1:6 complete all as specified and directed |
| 25 | M & L for Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15 mm thick backing coat in cement mortar (1:4) complete all as specified and directed. |
| 26 | M&L for non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing floor over and including 15mm thick screed bed/bedding layer in cement mortar 1:6 complete all as specified and directed. |
| 27 | M&L for joint free non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering (backing coat) in cement mortar 1:4 complete all as specified and directed. |
| 28 | M&L for non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing floor over and including 15mm thick screed bed/bedding layer in cement mortar 1:6 complete all as specified and directed. |
| 29 | M&L for joint free non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering (backing coat) in cement mortar 1:4 complete all as specified and directed. |
| 30 | Material and labour for coloured glazed ceramic tiles in vertical surfaces 350 x 250 x 7mm/450 x 350 x 7 mm/450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering (backing coat) in cement mortar 1:4 complete all as specified and directed. |
| 31 | Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 32 | M & L for taking down of existing roof treatment from roof and terrace, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following specification :-(a) Apply cement slurry over concrete surface @ 3Kg/Sqm.(b) Rendering 15mm thick in cement mortar (1:4) mixed with water proffing compound as per manufactures instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course).(c) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25 litres per Sqm conforming to IS: 3384-1986.(d) Applying evenly one coat of blown hot bitument of grade 85/25@ 1.20 Kg per square metre on primed surfaces.(e) A layer of APP based polymeric membrane, 3mm thick (minimum), weighing 3.5 kg/m2 reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (f) Applying evenly one coat of aluminium paint @ 0.10 litre per square metre over the APP based polymeric membrane. |
| 33 | Dismantling water tanks exceeding 500 litre capacity and not exceeding 1000 litre capacity and removing to store, complete all as specified and directed. |
| 34 | Supply and fixing of rotational moulded, multilayer HDPE water storage tank of 1000 litres capacity( tripple layer wall construction, cylindrical vertical with closed top) ISI marked hoisted and fixed in position all as specified in SSR Part I including 02 Nos 20 mm bore full threaded GI nipple of required size including ball valves 20 mm bore high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm - 210gms including refixing of inlet, outlet & over flow pipe etc complete all as specified and directed. |
| 35 | S&F 20 mm bore gun metal, glove or gate valves ISI marked with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 36 | S&F in repairs 15mm dia bib tap, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 37 | S&F in repairs 15 mm dia pillar tap, fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe & fixed complete all as specified and directed. |
| 38 | S&F in repair 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets & flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern including PVC connection pipe of size 15 mm dia, 450 mm long with PTMT nuts complete all as specified and directed. |
| 39 | S&F in repair wash hand basin, white flat back of size 550 x 400mm excluding pillar taps but including waste coupling, waste pipe and bracket, PVC connection pipe of 15 mm size with PTMT nuts of length 600mm, etc. including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. |
| 40 | Supply and fixed in repairs vitreous china squatting pan, Orissa pattern of size 580 mmx440mm white with P or S trap, front or back inlet and integral foot rest ( Excluding flushing cistern and flush pipe) including provision of cement concrete bedding (PCC 1:4:8, type D2) complete all as specified and directed. |
| 41 | M&L for 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washers complete all as specified and directed. |
| 42 | S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. including taking out old steel tubing of 15mm bore and connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 43 | S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. including taking out old steel tubing of 20mm bore and connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 44 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 20 cm girth in brick walls etc complete all as specified and directed. |
| 45 | M&L for Providing and fixing false ceiling of designer tiles (High Pressure steam cured) of 4 mm thickness (as per IS : 14862) of Size 595 X 595 mm and any of the design (Cascade or electra) in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 grams, both side inclusive and black painted groove on all T webs) consisting of Main T runner with suitably spaced joints to get required length and 15 X 32 mm made from 0.30 mm thick sheet 1200 mm long spaced between main \\"T\\" at 600 mm C/C to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 15x32 mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x20x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc Main \\"T\\" runners to be suspended from trusses/ceiling using suitable suspension arrangement as per manufacturers instruction/literature, GI adjustable wire of 4mm dia with galvanized butterfly level clips, spaced at 1200 mm C/C along main \\"T\\", bottom exposed width of 15 mm of all \\"T\\" sections of 4 mm dia GI wire shall be pre-Painted with polyester paint and black painted groove at centre of Size 4mm depth and 4.5 mm width, including dismantlingof old existing false ceiling and connected accessories at any heights complete all as specified and directed. |
| 46 | S & F Soap dish chromium plated of size not less than 100mm, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed |
| 47 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including taking down soil pipe/ rainwater pipes (any size or pattern) and all fittings (heads, shoes, bends, swan-necks,etc.) including cleaning or refixing (measured overall as fixed along the centre line over fitting and accesories) complete all as specified and directed. |
| 48 | S&F for 110mm dia PVC bend fixed with rubber ring fixed to wall including scafolding complete all as specified and directed. |
| 49 | S&F for 110mm dia PVC (SWR) branch piece,single (single Y) equal or unequal with access door including scafolding complete all as specified and directed. |
| 50 | S&F for 110mm dia PVC (SWR) junction single (single T) equal or unequal with access door including scafolding complete all as specified and directed. |
| 51 | M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, including making good disturbed area/surfaces with cement concrete/cement mortar 1:2:4 type B-0, etc including taking down old unserviceable nahani/floor trap complete all as specified and directed. |
| 52 | S & F PVC (SWR) vent cowl 110mm dia complete all as specified and directed. |
| 53 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 54 | M&L for 75 mm thick cement concrete type C2 1:3:6 using 20 mm graded aggregate as in plinth protection finished fair and even with using extra cement complete all as specified and directed. |
| 55 | M&L for cement concrete type C2 1:3:6 using 40 mm graded aggregate in surface channels and drains complete all as specified and directed. |
| 56 | M & L for rendering 15mm thick plaster in CM (1:4) on fair faces of brick work or on concrete surfaces in two layers (10mm thick 1st layer + 5mm thick finishing layer) finished even and smooth with out using extra cement mixed with liquid water proofing compound (for 5mm thick finishing layer only) @ 2% by weight of cement or as per manufacturer's instruction including taking down existing plaster of any description complete all as specified and directed. Note: Liquid water proofing compound will be measured and paid separately |
| 57 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 58 | Material and labour for 10 mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces as in walls, finished even and smooth without using extra cement including taking down old existing plaster complete all as specified and directed. |
| 59 | Material and labour for 5 mm thick rendering in cement mortar (1:3) on fair faces of exposed/non exposed concrete surfaces such as soffits of slabs, chajja, facia and simillar work including mixing & application of integral water proofing compound as per manufacture instruction of finishing the surfaces fair and even including taking down of cement plaster of any description including racking out joints for key scrubing with water complete all as specified and directed. |
| 60 | Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqmm over new surfaces including necessary scaffolding work upto tripple storey buildings complete all as specified and directed. |
| 61 | M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed. |
| 62 | Material and labour for three coats of white wash on newly plastered surfaces of ceiling including preparation of new plastered surfaces complete all as specified and directed. |
| 63 | M&L for complete removal of existing treatment on walls and applying two coats of distemper oil emulsion over alkali resistant primer complete all as specified and as directed |
| 64 | Material & Labour for complete removal of the existing treatment of old plastered surface of wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on old surfaces complete all as specified and as directed. |
| 65 | Material and labour for preparation of old surfaces of ceiling and applying two coats of white wash surfaces on ceiling including preparation of old surfaces complete all as specified and directed |
| 66 | Dismantling AC/CGI/PPGI corrugated or semi corrugated sheets in wall cladding or roof coverings and hanger doors including ridges and making good the aluminium earthing strips after fixing of sheets complete all as specified and directed. |
| 67 | S&F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed . |
| 68 | S&F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed . |
| 69 | Fixing only plain or corrugated steel sheet of any guage or thickness as obtained from dismantling item and shall be fixed with 'L' or 'J' type hooks or cranked hook bolts as in roof all as specified and directed. |
| 70 | S & F weather boarding clean sawn/plain, 25mm thick and 225mm wide (V jointed to give 20mm laps) to replace old decayed boarding including cutting out old pieces and removing dismantling boarding complete all as specified and directed. |
| 71 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed. |
| 72 | Material and labour for hard core with broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rolled/ rammed to a true surface complete all as specified and directed. |
| 73 | M&L for cement concrete 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 74 | M & L for Chequered cement concrete tiles of size 30cm x 30 cm x 25mm thick with mixture of white and grey cement in equal portions and no pigment, set over 20mm thick screed bed or bedding layer of cement mortar of 1:4 for laying floor finishes, jointed and pointed in neat cement slurry in floors complete all as specified and directed. |
| 75 | S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm complete all as specified and as directed, |
| 76 | S&F in repair 15 mm size stop valve, fancy type, chromium plated, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union & fixed complete all as specified and directed. |
| 77 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 78 | Taking down carefully MCB DBs SP/TP by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for re-use at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed. |
| 79 | M & L for point wiring for one light/fan point controlled by one, one way switch with 1.5 Sqmm single core, PVC FRLSH insulated unsheathed, multistranded copper conductor drawn through and including PVC casing and caping including necessary accessories like bends, tees, PVC square and elbow etc fixed to wall/ceiling with and including 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth continuity wire (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes with plastic laminated white/coloured top sheet cover 3 mm thick complete all as specified and directed. |
| 80 | All as per serial item No 79 here in before but for one 3 pin 5 Amp socket outlet on independent board. |
| 81 | All as per serial item No 79 here in before but for one 3 pin 5 Amp socket outlet on same board with other switches. |
| 82 | All as per serial item No 79 here in before but for one light/fan point controlled by two 2 way switches. |
| 83 | All as per serial item No 79 here in before but for one bell point controlled by one push button switch. |
| 84 | M&L for point wiring with 2.5 sqmm FRLSH PVC insulated and sheathed multi stranded (FRLSH) flexible copper conductor cable drawn in PVC casing and caping on surface wall, ceiling with sunk cast iron/pressed steel terminal boxes of adequate size with suitable thickness plastic laminated sheet, cover for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm copper conductor cable (FRLSH) (multistanded) PVC insulated and unsheathed cable as earth wire to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes with plastic laminated white/coloured top sheet cover 3mm thick complete all as specified and directed. |
| 85 | Supply and fixing switch piano flush type 240 Volts 5 Amps, SP, one way complete all as specifed and directed. |
| 86 | Supply and fixing switch piano flush type 240 Volts 5 Amps, SP, two way complete all as specifed and directed. |
| 87 | Supply and fixing bell push piano flush type 240 Volts 5 Amps, SP, one way complete all as specifed and directed. |
| 88 | Supply and fixing switch socket outlet combination 3 Pin,5 Amps, 240 volts flush type (non shuttered) with white colour complete all as specified/ directed. |
| 89 | Supply and fixing socket outlet 5 pin 5 Amps 240 Volts flush type (non shuttered) complete all as specified and directed. |
| 90 | Supply and fixing switch socket out let combination multipurpose 3 pin, 5/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) with white colour complete all as specified and directed. |
| 91 | Supply and fixing ceiling rose surface 3Phase/PVC/Polycarbonate, isolated body complete all as specified and directed. |
| 92 | Supply & fixing ceiling fan regulator electronic, Deluxe, rotary, step type, 120/280 V complete all as specified and directed. |
| 93 | Supply and fix in repairs MCB SPN DB 8 way double door, IP 43 protection, glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09 complete all as specified and directed. |
| 94 | S&F in repairs MCB SPN 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed. |
| 95 | S&F MCB, SP 6 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed. |
| 96 | S&F lamp holder, 240 volt 50 HZ, white PVC/Polycarbonate type angle/batten fittings complete all as specified and directed. |
| 97 | S&F LED fitting 1x20 watts (4 ft, 100 lm/W) including tube rod, 230 Volts, bipin holders connector block etc. complete with all accessories internally pre-wired and including provision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with flexible cable from ceiling rose to light fitting complete all as specified and directed. |
| 98 | S&F inverter LED batten with square profile and polycarbonate channel, Lithium iron battery with charging time 8-10 hours and backup time upto 04 hours, capacity 10W, length 2' complete all as specified and directed. |
| 99 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cables of suitable size complete all as specified and directed. |
| 100 | S&F recessed mounted 2' x 2' feet inverter LED panel light main housing duly powder coated CRCA Sheet steel ,Lion battery of 3-4 hours backup after fully charge, system lumen efficiency ≥ 100lm/W,CRI ≥ 80, THD≤10%, Driver efficiency ≥ 85% including taking down of old unserviceable fitting complete all as specified and directed. |
| 101 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of SSR Part-I (2009) including filling of charcoal dust, common salt all around earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thick RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced with 6mm dia MS bars @ 75mm C/C both ways and provision of suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. including testing on completion complete all as specified and as directed . Note: The rate quoted is deemed to be inclusive of minimum 7.5 metre earthing wire. |
| 102 | Material & labour for sub main wiring with two runs of single core, FRLSH 6 sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi-standed copper conductor cable LT 1100 volts grade drawn through PVC casing capping of adequate size fixed on surfafce of wall/ceiling with all necessary fittings and accessaries and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 6 sqmm as earth wire (green in colour) run through casing capping and connected common earth dolly including taking down of old unserviceable submain wiring complete all as specified and directed. Note : Two run of 6 Sqmm cable, one run of casing caping and one run of 6 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed. |
| 103 | Supply only LED Inverter bulb of 9 Watt (Warm white) compatable with B22 holder |
| 104 | Supply and fixing of LED building security light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with inbuilt surge protection of minimum 5 kV and repair/replacement warranty of minimum 3 years of capacity 35W complete all as specified and directed. |
| 105 | S&F for 32 mm dia GI tubing light grade bracket over all 1.2 m length with cutting as required and bend to shape with flat iron clamp of size 32 mm 2 Nos, suitable size of nut bolts and washers complete for fixing street light fittings on electric poles including taking down old unserviceable/fully rusted existing one complete all as specified and directed. Please Enable Macros to View BoQ information |
| 106 | S&F for 32 mm dia GI tubing light grade bracket over all 1.2 m length with cutting as required and bend to shape with flat iron clamp of size 32 mm 2 Nos, suitable size of nut bolts and washers complete for fixing street light fittings on electric poles including taking down old unserviceable/fully rusted existing one complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysOct 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender