Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57451700

Tender For Repair/Maintenance Of Ht Vcbs, Rmu And Allied Works At Mrs And Sub Station At North Area Under Age E/M (Es) At Ge (U) Meerut Cantt

Issued by Statutory Bodies & Commissions/Committees · Meerut, Uttar Pradesh
Tender Value
75 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
5 days left
EMD
1.37 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Meerut → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance Of Ht Vcbs, Rmu And Allied Works At Mrs And Sub Station At North Area Under Age E/M (Es) At Ge (U) Meerut Cantt

BOQ

Name of Work:- REPAIR/MAINTENANCE OF HT VCBs, RMU AND ALLIED WORKS AT MRS AND SUB STATION AT NORTH AREA UNDER AGE E/M (ES) AT GE (U) MEERUT CANTT
Sl. No. Item Description
1M & L for servicing and checking of EXISITING 11 KV Breakers any make and type make VCB with blower, cleaning of existing HT panel inside & outside with tighting of all bus bar, nut & bolt, alignment, adjustment of gaps between phase to phase as per manufacturer recommended, Checking and tightening of control wiring circuit as charging motor closing coil and tripping coil circuit, Manually tripping testing of VCB, Cleaning, removal of dust and dirt to male/Female contacts, greasing & lubrication all moving fixed part including replacement of minor parts such as spring, washers, etc. for smooth mechanical operation etc. complete with testing commissioning as required. Servicing, testing of ( one earth fault one over current) 11 KV /VCB, Operational testing through relay front pad as well as push button, Testing of safety relays, Tripping testing of VCB through over current and earth fault relay,testing and servicing of the existing 11 kV VCB panel, including high pot tests and submission of test certificates with proper sealing. Primary injection testing to verify tripping functionality. Opening of HT panel, removal of moisture from busbars, insulators, HT cable box, and heating of P.T. and C.T. chambers. Relay settings to be checked and configured as per the protection scheme. During breaker racking, inspection of jaw-type male/female contacts connected to the busbar is included—cleaning or replacement shall be done if found carbonized or damaged. Final insulation resistance (megger) testing of all components to be completed as per standard procedures and safety norms complete all as specified and directed. Note :- Minor spare part should incl in qouted rates for making functional & major spare may be pay separety as per BOQ Items.
2M & L for servicing and checking of EXISITING 33 KV Breakers along with 33kV CR Panel indoor type at MRS any make and type make VCB with blower, cleaning of existing HT panel inside & outside with tighting of all bus bar, nut & bolt, alignment, adjustment of gaps between phase to phase as per manufacturer recommended, Checking and tightening of control wiring circuit as charging motor closing coil and tripping coil circuit, Manually tripping testing of VCB, Cleaning, removal of dust and dirt to male/Female contacts, greasing & lubrication all moving fixed part including replacement of minor parts such as spring, washers etc. for smooth mechanical operation etc. complete with testing commissioning as required. Servicing, testing of ( one earth fault one over current) 33 KV /VCB, Operational testing through relay front pad as well as push button, Testingof safety relays, Tripping testing of VCB through over current and earth fault relay,testing and servicing of the existing 33 kV VCB panel, including high pot tests and submission of test certificates with proper sealing. Primary injection testing to verify tripping functionality. Opening of HT panel, removal of moisture from busbars, insulators. Relay settings to be checked as per UPPCL setting and configured as per the protection scheme. Final insulation resistance (megger) testing of all components to be completed as per standard procedures and safety norms complete all as specified and directed. Note : Minor spare part should incl in qouted rates for making functional & major spare may be pay separety as per BOQ items.
3M & L for Dismantling of old damaged /bursted bus bar insulators and replacement with new Environment Rating Moderately enabled insulators suitable for Indoor installation with 3-phase 50 Hz, 11 kV systems and they should be designed suitable for service under fluctuations in supply voltage up to ±12%. rules made there under. Nominal system Voltage 11 KV Minimum Specific Creepage Distance 12 KV 230 mm Minimum failing load Visible Discharge Voltage 5 KN 09 KVrms P.F Minimum flash over voltage a) Dry 75KVrms b) Wet 45KVrms , Impulse flashover voltage 1.2/50 micro second wave: a) Positive 95KVp b)Negative 100KVp , Withstand Voltage: a) Dry : 60KVrms b)Wet : 35KVrms 35KVrms Impulse withstand voltage 1.2/50 micro second wave: a) Positive 75KVp b) Negative 80 KVP, Power Frequency puncture withstand voltage 105KVrms complete all as specified and directed. Please Enable Macros to View BoQ information
4M & L for Dismantling of old damaged /bursted bus bar insulators and replacement with new Environment Rating Moderately enabled insulators suitable for Indoor installation with 3-phase 50 Hz, 11 kV systems and they should be designed suitable for service under fluctuations in supply voltage up to ±12%. rules made there under. Nominal system Voltage 11 KV Minimum Specific Creepage Distance 12 KV 230 mm Minimum failing load Visible Discharge Voltage 5 KN 09 KVrms P.F Minimum flash over voltage a) Dry 75KVrms b) Wet 45KVrms , Impulse flashover voltage 1.2/50 micro second wave: a) Positive 95KVp b)Negative 100KVp , Withstand Voltage: a) Dry : 60KVrms b)Wet : 35KVrms 35KVrms Impulse withstand voltage 1.2/50 micro second wave: a) Positive 75KVp b) Negative 80 KVP, Power Frequency puncture withstand voltage 105KVrms complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57451700
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 75 Lakhs
LAST DATE 08-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of Ht Vcbs, Rmu And Allied Works At Mrs And Sub Station At North Area Under Age E/M (Es) At Ge (U) Meerut Cantt
Basic Detail
Tender No 94411/MRT/2026-27/E8
Bidding Type Tender
Location
City Meerut
State Uttar Pradesh
Key Dates
Publish Date 10 Sep 2026
Submission Date 08 Oct 2026
Open Date 15 Oct 2026
Finance
Tender Value 75 Lakhs
Tender Fee 1000
EMD 1.37 Lakhs
Exemption Available
Document List
BOQ_884146.xls
c885ff02-e24a-4c6e-abed-1e4fd7436282.html
TD1.pdf
TD2.pdf
TD3.pdf
TD4.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Oct 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_884146.xls

html

c885ff02-e24a-4c6e-abed-1e4fd7436282.html

pdf

TD1.pdf

pdf

TD2.pdf

pdf

TD3.pdf

pdf

TD4.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders