Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #57451662

Tender For Provn Of Cook House Cum Dining Hall For 50 Per At Cul-G West C , Provn Of 20 Men Or Living Shelter At Cul-I At East C , Provn Of Cooling Health Room At North C , Drainage System In North C , Provn Of Drainage At South C And Provn Of 09 Acs

Issued by Statutory Bodies & Commissions/Committees · Bikaner, Rajasthan
Tender Value
1.02 Crore
Estimated cost
Bid Submission
08 Oct 2026
13 days left
EMD
1.77 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Cook House Cum Dining Hall For 50 Per At Cul-G West C , Provn Of 20 Men Or Living Shelter At Cul-I At East C , Provn Of Cooling Health Room At North C , Drainage System In North C , Provn Of Drainage At South C And Provn Of 09 Acs At Various Authorized Locations At Mffr Under Age (I) Mffr

BOQ

Name of Work:- PROVN OF COOK HOUSE CUM DINING HALL FOR 50 PER AT CUL-G WEST C , PROVN OF 20 MEN OR LIVING SHELTER AT CUL-I AT EAST C , PROVN OF COOLING HEALTH ROOM AT NORTH C , DRAINAGE SYSTEM IN NORTH C , PROVN OF DRAINAGE AT SOUTH C AND PROVN OF 09 ACS AT VARIOUS AUTHORIZED LOCATIONS AT MFFR UNDER AGE (I) MFFR
Sl. No. Item Description
1Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in loose/soft soil complete all as specified and as directed by Engineer-in-Charge.
2M&L for PCC (1:4:8) type D2 using 40mm graded stone agg as in mass filling and foundation complete all as specified and as directed by Engineer-in-Charge.
3M&L for Brick work with fly ash bricks old size straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed by Engr-In-Charge.
4M&L for Brick work with fly ash bricks old size straight or curved on plan exceeding 6m mean radius built in CM 1:4 complete all as specified and as directed by Engr-In-Charge.
5M&L for Form work to sides of concrete foundations, footings, bases of columns, sides and soffits of foundation and plinth beams complete all as specified and as directed by Engineer-in-Charge.
6M&L for Form work to sides and soffits of floor or roof beams, lintels, cantilevers etc complete all as specified and as directed by Engineer-in-Charge.
7M&L for Form work to sides of pillars, posts and columns complete all as specified and as directed by Engineer-in-Charge.
8M&L for M-25 Design mix type B1 (20mm graded aggreate) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by Engineer-in-Charge.
9M&L for M-25 Design mix type B1 (20mm graded aggreate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer-in-Charge.
10M&L for M-25 Design mix type B1 (20mm graded aggreate) Columns, pillars, piers, posts and struts complete all as specified and as directed by Engineer-in-Charge.
11M&L for Pre cast RCC type M-25 using 20 mm graded crushed stone aggregate as slabs supported on walls, manhole cover slab, beams & columns in floors, roofs, landings, balconies and in shelves and the like including necessory form work complete all as specified and as directed by Engineer-in-Charge.
12M&L for steel reinf TMT bars 10 mm dia and over cut to length and bent to shape required including cranking, bending spirally for hoping for columns,beam, hooking end and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.
13M&L for steel reinf TMT bars but 5mm dia and over upto and including 10mm dia as in stirrups spacer and binders complete all as specified and as directed by Engineer-in-Charge.
14Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and as directed by Engineer-in-Charge.
15Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by Engineer-in-Charge.
16M&L for 15mm thick Rendering in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, finished fair and even without using extra cement complete all as specified and as directed by Engineer-in-Charge.
17M&L for 10 mm thick Rendering in cement mortar 1: 6 on fair faces of brick work or concrete surfaces, finished fair and even without using extra cement complete all as specified and as directed by Engineer-in-Charge.
18M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of cement paint white or tinted over a coat of alkali resistance priper complete all as specified and as directed by Engineer-in-Charge.
19M&L for preparation of newly plastered surfaces of wall & chajjas and applying two coats of Acrylic emulsion paint (Exterior grade) of approved shade/tint over a coat of suitable priming paint complete all as specified and as directed by Engineer-in-Charge.
20M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of oil Bound Distemper white or tinted over a coat of primer complete all as specified and as directed by Engineer-in-Charge.
21M&L for sand filling under floors or in foundation inxluding watering abd consolidations complete all as specified and as directed by Engineer-in-Charge.
22M&L for broken stone Hardcore of broken stone or boulders of gauge n. exc 63 mm, deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge.
23M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone agregate as sub base of floors complete all as specified and as directed by Engineer-in-Charge.
24M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate in any position in floor/roof complete all as specified and as directed by Engineer-in-Charge.
25M&L for 18-20 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including 20mm thick screed bed in cement and sand mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
26M&L 18-20 mm thick machine cut kota stone slab as in skirting/dado etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including 10mm thick rendering in cement and sand mortar 1:4 complete all as specified and as directed by Engr-in-Charge.
27M&L for coloured Non skid ceramic joint free floor tiles 7 to 8 mm thick (Square/rectanguler) of size 600x600 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge.
28M&L for Glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick rendering in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
29M & L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engineer-in-Charge.
30Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engineer-in-Charge.
31M&L for machine pressed precast concrete interlocking paver block of approved shape and size of 60 mm thickness, with minimum compressive strength of 35 N / Sqmm (M-35 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating, and top surface with white cement and pigment complete all as specified and as directed by Engineer-in-Charge.
32S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed by Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
33S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed by Engineer-in-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
34Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash 'extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and all necessary fittings complete all as specified and as directed by Engineer-in-Charge.
35S&F 10mm thick toughned glass as in hinged doors, partitions automatic doorsand similar work including cutting to shape, drilling holes and all fixing accessories required complete all as specified and as directed by Engineer-in-Charge.
36M&L for MS work as in hold hast etc. complete all as specified and as directed by Engineer-in-Charge.
37M&L for Cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in filling in hold fast area in walls etc complete all as specified and as directed by Engineer-in-Charge.
38S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain glazed and skeleton door shutter of 30 mm thick open rebated and prepared to receive glass , guaze etc without sash bar , edges of framing plain , chamfered or rounded fitted with cut and mitred beads for securing guaze etc, size of members as directed suplied and fixed to chowkhat complete all as specified and as directed by Engineer-in-Charge.
39Supply, fabricate & fix in position aluminium powder coated (minimum thickness of powder coating 50 micron) two track window (two shutter glazed) with frame, glazed with 4mm thick tinted glass, including rubber bead joining cleat for fixing in position, concealed type lock for all two shutter, PVC roller etc all as specified below including taking down old window, complete all as specified and directed by Eng-in-Charge.(a) Frame (top & side ) section shall of size 92.00x31.75x1.50mm (Section o 20831).(b) Frame (bottom) section shall of size 92.00x31.75x1.50mm (section No 20832).(c) Top & side members of shutter section shall be of size 18.00x40.00x1.55mm (Section No 20738).(d) Shutter interlock section shall be size 18.00 x 40.00x1.45mm (Section 20737)(e)Bottom members of shutter section shall be size 18x40.00x1.55mm (Section No 20736)Note : Section No given above are of make Jindal, contractor may use similar section of other make mention in Appx B
40S&F stainless steel wire netting of , 0.36 mm nominal dia fixed with tinned tacks of stainless stell wire staples with average width of aperture 1.40mm, complete all as specified and as directed by Engineer-in-Charge.
41S&F Anodised aluminium frame /truck for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-Charge.
42S&F Anodised aluminium window and ventilator shutters,/ sliding shutter , fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, wire mesh and grills etc. complete all as specified and as directed by Engineer-in-Charge.
43S&F 4.8mm thick sheet glass, ordinary quality and glazing with oil putty/rubber gasket in square of any thickness in each pane for metal frames complete all as specified and as directed by Engineer-in-Charge.
44S&F 5.50mm thick sheet glass, ordinary quality and glazing with oil putty/rubber gasket in square of any thickness in each pane for metal frames complete all as specified and as directed by Engineer-in-Charge.
45S & F Neoprene/ EPDM rubber gasket complete all as specified and as directed by Engineer-in-Charge.
46S&F 100mm lomg butt hinges, stainless steel medium weight complete all as specified and as directed by Engineer-in-Charge.
47S&F SS barrel tower bolt SS with bright bolt of length 200mm complete all as specified and as directed by Engineer-in-Charge.
48S&F SS sliding door bolts, plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 300mm long complete all as specified and as directed by Engineer-in-Charge.
49S&F 125mm long SS pressed handles, oval type, complete all as specified and as directed by Engineer-in-Charge.
50M&L for MS work as in framed work such as grills, gratting, guard bars, etc confirming to Fe-290 gde E-165 complete all as specified and as directed by Engineer-in-Charge.
51M&L for Plain cement concrete (1:2:4) type B-0, 40 mm thick as in damp proof course to horizontal or vertical surfaces including necessary form work using water proofing compound as per manufacturer’s instructions complete all as specified and as directed by Engineer-in-Charge.
52M&L for Cement concrete type B2 1:2:4 B, 40mm thick stone aggregate in surface channels and drains complete all as specified and as directed by Engineer-in-Charge.
53Supply only liquid water proofing compound complete all as specified and as directed by Engineer-in-Charge.
54M&L for Roughly squared stone lintels hammer dressed on face and soffits, hoisted, set and pointed in cement mortor 1:6 n.exc 3 m in length complete all as specified and as directed by Engineer-in-Charge.
55S&F joist , channel, angle, tee section, fixed independently without connecting plates etc. including welding as necessary confirming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-Charge.
56M&L for preparation of new steel surface of any description n. exc 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
57S&F rolled mild steel in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-290 (Gde E- 165) complete all as specified and as directed by Engineer-in-Charge.
58S& F rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410 Gde E-250 complete all as specified and as directed by Engineer-in-Charge.
59S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt 5 cm to 10cm and dia of neck 11 to 15 mm complete all as specified and as directed by Engineer-in-Charge.
60S & F Pre-painted galvatume ( Sand Colour ) aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of sand colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as complete all as specified and as directed by Engineer-in-Charge.
61S & F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of sand colour having tensile strength of 550 Mpa as in roof covering /cladding to wall and ridge , fixed with self tapping screws as complete all as specified and as directed by Engineer-in-Charge.
62Supply and installation of 50/80 mm PPGI PUF PPGI Roofing corrugated sandwich panel (PUF having density 40+- 2 Kg/m3 +PPGI sheet both side) complete all as specified and as directed by Engineer-in-Charge.
63M&L for 75mm thick PCC 1:3:6 type C-1 (Using 20mm gradede crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
64Supply and fixing Gl frame work of size of grid 605 X 605mm for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and gypsum board 12mm thick false ceiling board in grid as per specification complete all as specified and as directed by Engineer-in-Charge.
65M&L for Anodised aluminium ( size of grid 605x605mm) snap grid frame work for false ceiling . Snap grid ( main/cross tee section ) shall be supported at the ends all along the wall with anodized aluminium angle of size 40mmx25mmx2mm , weighing 0.36 kg per R/M as per SSR-2009 para 10.38.01 complete all as specified and as directed by Engineer-in-Charge.
66M&L 6mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed by Engineer-in-Charge.
67S&F Harrison rails,mild steel,curtain rod chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed by Engineer-in-Charge.
68M&L for 5cm thick Sand stone slabs in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
69M&L for Jodhpur stone of roof slab self faced ,7.5cm to 10 cm thick ,25 cm to 35cm wide ,hoisted and set ,jointed and grouted in cement and sand mortar (1:6) complete all as specified and as directed by Engineer-in-Charge.
70M&L for 50mm thick P.C.C 1:3:6 C2 using 40 mm graded stone agg. As in floors over stone patti roof slab finished the surface even and fair complete without using extra cement complete all as specified and as directed by Engineer-in-Charge.
71S&F Vitreous china wash basin, white, flat back, size 550 x 400mm, including brackets and cutting for and pinning in ends of brackets, and including waste Pipe and waste Coupling complete all as specified and as directed by Engineer-in-Charge.
72S & F in looking mirror 600mm x 450mm bevelled edge mirror of selected quality glass 5.5mm thick mounted on 6mm plywood with aluminium frame fixed to wooden plugs with CP brass screws & cup washers complete all as specified and as directed by Engineer-in-Charge.
73S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110mm bore complete all as specified and as directed by Engineer-in-Charge.
74S&F PVC (SWR) pipes, single socketed,in any length with rubber ring joints, fixed to walls, 75mm bore complete all as specified and as directed by Engineer-in-Charge.
75S&F PVC (SWR) bends any radius, 110mm bore complete all as specified and as directed by Engineer-in-Charge.
76S&F PVC (SWR) couplers, 110mm bore complete all as specified and as directed by Engineer-in-Charge.
77PVC (SWR) floor trap, plain with grating including jointing with solvent cement, dia of outlet 75 mm complete all as specified and as directed by Engineer-in-Charge.
78M&L for 15mm bore steel water tubes, medium grade. ISI marked, galvanised with all fittings, fixed to walls and ceilling or laid in floors complete all as specified and as directed by Engineer-in-Charge.
79M&L for 20mm bore steel water tubes, medium grade. ISI marked, galvanised with all fittings, fixed to walls and ceilling or laid in floors complete all as specified and as directed by Engineer-in-Charge.
80S&F angle valves, cast copper alloy, cp fancy type screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, 15mm bore complete all as specified and as directed by Engineer-in-Charge.
81S&F Rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of 2000 litres capacity, hoisted and fixed in position including connecting up pipes ccomplete all as specified and as directed by Engineer-in-Charge.
82S&F Bib taps cast copper alloy Chromium Plated fancy type with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and as directed by Engineer-in-Charge.
83S&F pillar tapes, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore complete all as specified and as directed by Engineer-in-Charge.
84S & F soap dish any type fixed to plugs with chromium plated brass screws complete all as specified and as directed by Engineer-in-Charge.
85S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (Minimum weight 210 gms) complete all as specified and as directed by Engineer-in-Charge.
86S&F waste fittings 32 mm bore, brass, chromium plate for glazed ware sinks, basins, etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer-in-Charge.
87S&F Tower Rail 600 mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190 gms) complete all as specified and as directed by Engineer-in-Charge.
88S&F PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by Engineer-in-Charge.
89M&L for Soakage well of size 1.2m dia and 3 m effective depth, excavation in any type of soil, foundation in PCC 1:3:6, walls of honeycommed masonary with top ring of M-25 RCC concrete including intercepting camber and screen chamber made of brick masonary in CM, RCC cover slab in M-25/ SFRC cover, interconnecting pipes or RCC/PVC complete all as specified and as directed by Engineer-in-Charge.
90M & L for treating the bottom and sides of excavation at the rate of 5 liters of emulsion per square meter area of surface complete all as specified and as directed by Engineer-in-Charge.
91M & L for treating the back fill in contact with backfill in contact with foundation at the rate 7.5 liters of the emulsion per sq meter area (area of the sub structure in contact with the backfill to be measured) complete all as specified and as directed by Engineer-in-Charge.
92M & L for treating the top surafce of filled earth and under plinth area at rate of 5 liters of emulsion per square meter area of the surface area complete all as specified and as directed by Engineer-in-Charge.
93M & L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed by Engineer-in-Charge.
94M&L for Maroom/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled & rammed including watering complete all as specified and as directed by Engineer-in-Charge.
95M&L for PCC 1:3:6 type C2 using 40mm graded stone as in surface channel and drains, packing under and haunching to hume pipes etc complete all as specified and as directed by Engineer-in-Charge.
96M&L for PCC 1:3:6 type C1 using 20 mm graded stone as in coping and like weathering slightly round or chamfered angles and throating as directed and including necessary use and wase of formwork complete all as specified and as directed by Engineer-in-Charge.
97M&L for Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement incl forms, mould, mitred, stopped ends etc complete all as specified and as directed by Engineer-in-Charge.
98M&L for laying 300mm bore reinforced cement concrete pipes, class NP2 laid and jointed complete with collers complete all as specified and as directed by Engineer-in-Charge.
99M&L for Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested in cement concrete 1:3:6 type C-2 (using 20mm graded stone aggregate) 300mm dia pipe complete all as specified and as directed by Engineer-in-Charge.
100S&F single pole and neutral enclosure with two pin and earth plug and socket including 1Nos MCB 20Amps capacity complete all as specified and as directed by Engr-in-charge
101M&L for sub main wiring in PVC concealed conduit with 2 single core 6sqmm multi-stranded PVC insulated cable sheathed 1100 volts grade with one earth wire of 6 sqmm copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge. (Note two run of 6 sqmm and one run of 6 sqmm will be measured as 1 RM.
102Supply, installation, testing and commissioning of Mitsubishi Heavy Industries Split Type High Wall Inverter Air Conditioner, Model No. SRK24YVS-W6 (or equivalent approved make), having minimum cooling capacity 7.7 kW, BEE 5-Star rating with ISEER not less than 5.41, operating on 230V, single phase, 50 Hz AC supply. The unit shall be complete with DC PAM Twin Rotary Inverter Compressor, R-32 refrigerant, 100% copper condenser and evaporator coils, electronic expansion valve (EEV), 3D auto swing, jet flow technology, washable air filters, self-cleaning function, auto restart, sleep mode, timer, self-diagnosis facility, wireless remote controller and all standard accessories.The scope shall include indoor and outdoor units, interconnecting insulated copper refrigerant piping, control cable, drain pipe, mounting brackets/stands, vibration isolators, electrical connections, earthing, refrigerant gas charging (if required), testing, commissioning and handing over complete in all respects as directed by Engineer-in-Charge.
103S&F wall mounted digital Voltage Stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 130V - 290 V with output voltage stabilized at 230V with accuracy of + 2.5% suitable for 2 Ton AC complete all as specified and as directed by Engr-in-charge.
104Supply, installation, testing and commissioning of Refrigerator, 195 Litres capacity, Single Door, Direct Cool type, minimum 5 Star BEE Energy Rating (latest applicable), equipped with Inverter/Digital Inverter Compressor, operating on 230V AC, 50 Hz single phase supply, using eco-friendly R600a refrigerant, having toughened glass shelves, large vegetable crisper, freezer compartment with ice tray, egg tray, bottle storage, door lock, anti-bacterial removable door gasket, LED internal lamp, stabilizer-free operation (approximately 135–290V), adjustable front legs, low noise operation, and complete with all standard accessories, warranty card, installation and commissioning complete all as specified and as directed by Engr-in-charge. The refrigerator shall carry a minimum 1-year comprehensive warranty.
105Supply, installation, testing and commissioning of Glass Top Deep Freezer of minimum 200/205 litres gross storage capacity, suitable for operation on 230–240 Volts AC, 50 Hz, single phase supply, complete with heavy-duty hermetically sealed compressor, static cooling system, eco-friendly R290/R600a refrigerant, high-density PUF insulation (minimum 60 mm), corrosion-resistant pre-coated steel outer body, stucco aluminium/PCM inner liner, hard top hinged lid with lock and key, adjustable thermostat, wire baskets, heavy-duty castor wheels, drain plug for defrosting, recessed handle, interior illumination (if provided by OEM), and all standard accessories. The unit shall be capable of maintaining a storage temperature of –18°C or lower and suitable for tropical climatic conditions. The freezer shall have a minimum 5-Star energy rating (where applicable) and shall be supplied complete with factory-fitted power cord, 3-pin plug, user manual, installation, commissioning, testing, and demonstration to the user complete all as specified and as directed by Engr-in-charge. The item shall include minimum 1-year comprehensive warranty as per OEM standard.
106Supply, installation, testing and commissioning of fully stainless steel water cooler, electrically operated on 230-240 Volts AC, 50 Hz, single phase supply, having minimum storage capacity of 80 litres and nominal cooling capacity of 40 litres per hour (LPH) at ambient temperature up to 43°C. The unit shall be provided with heavy-duty hermetically sealed compressor, eco-friendly refrigerant (R134a/R290 or equivalent), stainless steel body and tank (SS-304 grade), high-density PUF insulation, automatic thermostat control, efficient condenser and evaporator assembly, food-grade water storage tank, anti-corrosive construction, sturdy faucet(s), overload protection, power cord with plug, and all standard accessories. The cooler shall be capable of delivering chilled potable water suitable for continuous operation under tropical climatic conditions. The item shall include all necessary fittings, connections, testing, commissioning, demonstration, and handing over complete all as specified and as directed by Engr-in-charge.
107Supply, Installation, Testing & Commissioning of Split Type Air Conditioner of 1.65 TR nominal cooling capacity, Mitsubishi Heavy Industries Model No. SRK18YXS2-W6 or equivalent approved make, suitable for operation on 220–240 V AC, 50 Hz, single phase, complete with Hyper Inverter DC rotary compressor, 100% copper condenser and evaporator coils with Blue Fin anti-corrosion coating, R-32 eco-friendly refrigerant, electronic expansion valve, BEE 5-Star rating (ISEER minimum 5.7), cooling capacity 5.825 kW, air throw up to 17 m, operating ambient temperature up to 55°C, 3D auto swing, auto restart, self-diagnosis, auto clean, LCD wireless remote, washable anti-bacterial filters, refrigerant piping, control cable, drain pipe, outdoor mounting brackets, vibration isolators, electrical connections, testing, commissioning, demonstration and handing over complete all as specified and as directed by Engr-in-charge. Installation shall include all accessories necessary for satisfactory operation.
108Suply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for inpur variation between 130V to 290 V with out put voltage stablized at 230 V with accuracy of +2.5% andf capacity 5 kVA complete all as specified and as directed by Engr-in-charge.
109Suply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for inpur variation between 130V to 290 V with out put voltage stablized at 230 V with accuracy of +2.5% andf capacity 3 kVA complete all as specified and as directed by Engr-in-charge.
110M&L for Point wiring for one light point/fan point/exhaust fan/bell point with FRLS copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and sheathed of size 2.5 Sq mm single core multistand in and including PVC concealed conduit Medium class 25 mm dia ISI marked with all fittings such as tees, bends, MS sunken box,modular plates as per site requirement for one fan/ light/Exhaust fan or 5/15Amps socket or bell/buzzer point controlled by one switch including provision of 2.5 Sqmm PVC insulated sheathed copper conductor cable, single core multistand as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
111All as per item No 110 here-in-before but socket point on the 5/6A independent board with other switches complete as specifed as directed by Engineer - In - Charge.
112All as per item No 110 here-in-before but socket point on the same board with other switches complete as specifed as directed by Engineer - In - Charge.
113All as per item No 110 here-in-before but cable of 4 Sq mm for 15 Amp switch socket outlet on independent board including provision of 4 Sqmm PVC insulated unshethed multistranded copper conductor as earth wire complete as specifed as directed by Engineer - In - Charge.
114Supply and fix Modular switch 1 way 6A, 1 modul complete all as specified and as directed by Engineer-in-Charge .
115Supply and fix Modular switch 1 way 16A, 1 modul complete all as specified and as directed by Engineer-in-Charge .
116Supply and fix Socket, 6A - 2/3 pin combined 2 modul complete all as specified and as directed by Engineer-in-Charge.
117Supply and fix Socket, 16A - 2/3 pin combined 2 modul complete all as specified and as directed by Engineer-in-Charge .
118Supply and fix LED inverter battery 20W CDL, tube light energy efficient with backup of 3 hrs autocut off features atfull charge, high lumen 100 lum/W complete as specifed as directed by Engineer - In - Charge.
119S&F in replacement of ceiling rose PVC/poly carbonate insulated body three terminal ISI marked, complete all as specified and as directed by Engineer-in-Charge.
120S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete as specifed as directed by Engineer - In - Charge.
121Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete as specifed as directed by Engineer - In - Charge.
122Supply, installation, testing and commissioning of wall mounted oscillating air circulator fan of 450 mm sweep, suitable for operation on 230 Volts AC ±10%, 50 Hz, single phase supply, complete with heavy-duty continuously rated copper wound induction motor,Motor Rating minimum 120 W,Speed Minimum 1350 RPM,Air Delivery Minimum 140 m³/min,Oscillation Angle Minimum 80°,Blade Material Aluminium, dynamically balanced,Number of Blades 3 Nos,Bearing Type Double Ball Bearing dynamically balanced aluminium aerofoil blades, automatic oscillation mechanism, adjustable vertical tilt arrangement, powder-coated heavy-duty steel wire safety guards on both sides, sturdy wall mounting bracket with fixing hardware, speed regulator, connecting cable, terminal box, all accessories and connected items complete.The fan shall be designed for industrial/ commercial applications and capable of continuous operation under tropical climatic conditions. The motor shall be provided with permanently lubricated ball bearings, thermal overload protection and Class ‘B’ or better insulation. The fan shall deliver high air circulation with low vibration and noise levels complete as specifed as directed by Engineer - In - Charge.
123Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) complete as specifed as directed by Engineer - In - Charge.
124Supply & fix exhaust fan, steel body, AC single phase, 230 Volt, size 300 mm sweep with blades, frame, louvers complete with fitting complete as specifed as directed by Engineer - In - Charge.
125Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc. complete as specifed as directed by Engineer - In - Charge.
126Supply and Fixing MCB single pole, 240 volts of rating 6-32 Amps of C curve breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge.
127Supply and Fixing MCB suitable for 6 to 32 Amps, 240 Volt AC supply C Curve single pole and neutral(SPN) with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.
128M&L for sub main wiring in PVC concealed conduit with 2 single core 6sqmm multi-stranded PVC insulated cable sheathed 1100 volts grade with one earth wire of 6 sqmm copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge. (Note two run of 6 sqmm and one run of 6 sqmm will be measured as 1 RM.
129S&F Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar, SPN 12 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall,and blanking plate as reuired complete all as specified and as directed by Engineer-in-Charge. Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate
130S&F Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar, SPN 8 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall,and blanking plate as reuired complete all as specified and as directed by Engineer-in-Charge. Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate
131S&F Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar, SPN 4 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall,and blanking plate as reuired complete all as specified and as directed by Engineer-in-Charge. Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate
132Supply, laying and testing 1100 volts grade heavy duty cable with PVC insulated aluminium conductor of size 4 Sq mm 2 core served with inner sheathing of PVC tape armoured with galvanised steel wire or tape complete as specifed as directed by Engineer - In - Charge.
133Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 2 core complete as specifed as directed by Engineer - In - Charge.
134Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sq mm 4 core complete as specifed as directed by Engineer - In - Charge.
135Supply,laying of double wall corrigated pipe of outer dia 77mm and inner dia 63 mm with connector for cable protection as per IS-16205 complete all as specified and directed by Engineer-in-charge.
136Supply, installation, testing and commissioning of LED Building Light 35/36 Watt, suitable for operation on 230V AC, 50Hz single phase supply, with minimum IP-65 protection, pressure die-cast aluminium housing, powder-coated finish, high efficiency LEDs, toughened glass/polycarbonate diffuser, integral electronic constant current driver with surge protection, power factor not less than 0.95 and system efficacy not less than 110 lm/W.The item shall include GI/MS wall mounting bracket fabricated from 40mm × 40mm × 5mm MS angle or suitable approved design, hot dip galvanized/powder coated, complete with base plate, anchor fasteners, nuts, bolts, washers, clamps and all fixing accessories. The fitting shall be mounted on wall/building structure at required height and connected complete all as specified and directed by Engineer-in-charge.
137M&L for Earthing complete with galvanised steel perforated pipes of electrode size 40mm bore buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing the same upto 30 cm above normal ground level with plug at top including pipe fittings etc complete and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No3 SSR Part-I complete as specifed as directed by Engineer - In - Charge.
138Supplying, installation, testing & commissioning CPRI approved outdoor cubical type LT feeder pillar box suitable for 415V, 3 phase, 4 wire 50 Hz, AC supply system fabricated from stainless steel (SS 316) totally enclosed, dust, weather & vermin proof, 3.0 mm thick for outer shell and 2 mm thick for inner shell having TPN copper busbars of rating 1.5 times that of controlling MCCB supported on SMC insulators with short circuit withstand capacity 35 MVA for 1 second, bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switchgears with required size of copper bus bars and control wiring with minimum 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates in two half including tamper proof digital energy meter to measure voltage, current, PF, KWH, KVAH, KVARH (Make - Secure / L&T / HPL / Schneider) and general construction confirming to IS:8623/93 and mounted on suitable PCC foundation with following detailed specifications & controls :-OUTER SHELL:- The outer shell shall be made of 3.0 mm thick stainless steel (SS 316) & MS angle section 50x50x6 mm frame with front & back openable, single door system lockable/openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The dimension of the outer shell should be adequate to accommodate inner shell described below giving 50 mm space all around & shall be fabricated in such a way that the complete inner shell alongwith its control gears & accessories could be taken outside without disturbing outer shell. The outer shell shall be mounted on a zinc metal coated stand. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The degree of protection of outer shell shall be IP-54.
139INNER SHELL:- Inner shell made of 2.0 mm thick stainless steel (SS 316) compartmentalized for each control gear, front openable single door system lockable/openable by keys from both sides having chromium plated fancy locks (2 Nos in each compartment) having louvers & air vent gasket for natural flow of air. ‘U’ type gasket shall be used to make the inner shell completely vermin proof & to accommodate incomer/outgoing MCCBs and TPN copper bus bar. extension links of rating not less than the 1.5 times the rated capacity of the respective MCCB. The TPN bus bar and extension links shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made of nonhygroscopic, noncombustible, track resistant, high strength SMC material at suitable interval throughout the length of the TPN bus bar. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided on bus bar chamber. All control wires shall be with not less than 1.5 sqmm multi strand copper conductors and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. The cubical shall have a bottom channel of size 75x40 mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness 3.15 mm zinc metal coated should be used at the bottom. Indicating lamps LED type, 230 volt, AC at the incomer of the unit to show three phase availability at the outgoing of incomer. An inspection lamp with 11 watt LED shall be fitted on top side of inner shell. The degree of protection for inner shell shall be IP-42 & carry the following controls:-1. Incoming:- One number MCCB 100 amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz with thermal, magnetic & microprocessor release adjustable between 40% to 100% against overload setting. 2. Outgoing:-(a) MCB two pole, 63 Amp -06 (b) MCB TPN, 63 Amp -01 Nos
140Supply, installation, testing and commissioning of Outdoor Desert Air Cooler of minimum 6000 CFM air delivery capacity suitable for operation on 230 Volts, 50 Hz, single phase AC supply, with suitable stand complete with all accessories and controls, comprising the following specifications:- (a) Body made of heavy-duty galvanized steel sheet not less than 22 gauge thickness, duly pre-treated with anti-corrosive treatment and finished with powder coating. (b) Minimum air delivery capacity : 6000 CFM. (c) Copper wound motor of minimum 1/2 HP rating, suitable for continuous duty operation, with low noise and energy-efficient performance. (d) Fan assembly comprising heavy-duty balanced axial/centrifugal fan made of aluminium/GI, capable of delivering the specified air quantity. (e) Cooling media consisting of high-efficiency honeycomb cellulose cooling pads of minimum 100 mm thickness on three sides. (f) Water tank of minimum 100 litres capacity, leak-proof construction, complete with drain plug. (g) Heavy-duty water circulating pump of suitable capacity for uniform water distribution over cooling pads. (h) Float valve arrangement for automatic maintenance of water level. (i) Air deflecting louvers with manual adjustment facility. (j) Complete electrical controls including ON/OFF switch, fan speed regulator (minimum three-speed operation), pump switch, indicator lamp, internal wiring, terminal connections and power cord. (k) Suitable mounting arrangement, vibration-free operation and all accessories required for proper functioning. (l) Provision of earthing and connection to existing electrical supply and water source. (m) The cooler shall be complete with all fittings, accessories, fasteners, nuts, bolts and consumables required for satisfactory operation. (n) Testing and commissioning complete and demonstrating satisfactory performance to the Engineer-in-Charge.
141M&L for Cutting existing steel tubing of size upto 50mm bore for alterations or additions (each cut measured) done in position without taking down complete all as specified and as directed by Engr-in-charge.
142Screwing existing steel tubing for alterations or additions (or lenghtening screw on pipe to form connector) done in position without taking down complete all as specified and as directed by Engr-in-charge.
143M&L for steel water tubes, medium grade, galvanised, with all fittings , laid in trenches fixed to wall of size 25mm dia and connecting with existing lines with suitable GI Tee including testing complete all as specified and as directed by Engr-in-charge.
144S&F Gun Metal gate valve with iron wheel head, screwed both ends for iron pipe of size 25mm dia complete all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57451662
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.02 Crore
LAST DATE 08-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Cook House Cum Dining Hall For 50 Per At Cul-G West C , Provn Of 20 Men Or Living Shelter At Cul-I At East C , Provn Of Cooling Health Room At North C , Drainage System In North C , Provn Of Drainage At South C And Provn Of 09 Acs At Various Authorized Locations At Mffr Under Age (I) Mffr
Basic Detail
Tender No CA No CWE BKN-Token No 46/2026-2027
Bidding Type Tender
Location
City Bikaner
State Rajasthan
Key Dates
Publish Date 10 Sep 2026
Submission Date 08 Oct 2026
Open Date 15 Oct 2026
Finance
Tender Value 1.02 Crore
Tender Fee 1000
EMD 1.77 Lakhs
Exemption Available
Document List
7522ff6e-cd75-4502-abf1-7168d6ede1e3.html
BOQ_884177.xls
BTD804SoakWell.pdf
Tender46.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Oct 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

7522ff6e-cd75-4502-abf1-7168d6ede1e3.html

xls

BOQ_884177.xls

pdf

BTD804SoakWell.pdf

pdf

Tender46.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders