Rural Development Government Departments Closing in 9 days TDR #57451149

Tender For Repair And Maintenance Of Phc (Ama Hospital) Building At Judabali For The Year 2025-26

Issued by Government Departments · Kandhamal, Odisha
Tender Value
75.84 Lakhs
Estimated cost
Bid Submission
22 Sep 2026
9 days left
EMD
75850
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kandhamal → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Phc (Ama Hospital) Building At Judabali For The Year 2025-26

BOQ

Name of Work:- Repair and Maintenance of PHC (AMA Hospital) Building at Judabali for the year 2025-26
Sl. No. Item Description
1GROUND FLOORRemoving old lime or cement plaster from walls including racking out joints 12mm deep and removing debris etc with all labour, T&P and cess etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
2Earth work excavation in foundation hard soil including moorum, stoney earth mixed with boulders with all leads and lifts including dressing.Complete in all respect as per specificationand direction of the Enginineer in Charge
3Supplying, filling in foundation and plinth with sand in layers well watered and rammed including cost, conveyance, royalty of all the materials.etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
4Providing cement concrete (1:3:6) in foundation and plinth using 4cm size clean hard black granite metal of approved quality. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
5R.R.H.G stone masonry in cement mortar (1:6) in foundation and plinth with hard black broken granite stone of approved size and quality. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
6Cement concrete of proportion (1:2:4) using 12mm size hard granite chips of approved quality from approved quarry including hoisting, lowering. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
7R.C work (1:1½:3) with clean hard crusher broken granite chips of 12mm size of approved quality from approved quarry including etc. Complete in all respect as per specificationand direction of the Enginineer in ChargeColumn base
8Columns & BeamsRoof Beams
9Plinth beams
10Lintels
11Chajja
12Roof Slab
13Cutting, bending, binding and tying the grills and placing in proper position as per drawing and design including cost, conveyance and taxes of M.S. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
141st class well Clamp Burnt brick masonry in cement mortar (1:6) in super structure using clamp burnt bricks of 23x11x8cm size. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
1520mm th Cement plaster in C.M (1:4) including punning over walls, finished smooth including watering curing and scaffolding with cost. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
1616mm th Cement plaster in C.M (1:6) to brick work finished smooth including watering curing and scaffolding with cost. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
1712mm th Cement plaster in C.M (1:6) to brick work finished smooth including watering curing and scaffolding with cost. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
1820mm th Cement plaster in C.M (1:6) to stone work finished smooth including watering curing and scaffolding with cost. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
19Finishing surface of walls with cement based wall putty (Water based) of approved make and finished smooth and even surface to receive. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
20Wall priming one coat with approved primer with brush to wall surface after cleaning the surface including cost, conveyance, taxes of all the. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
21Wall painting two coats with plastic emulsion paint of approved shade over a coat of priming on new work to give an even shade with approved. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
22Distempering two coats with approved shade, over a coat of priming with cost, conveyance, taxes of all the materials required for the work. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
23Finishing walls with water proofing cement paint (Weather coat) of approved shade on new work two coats, over a coat of priming, to give. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
24Supplying, fitting, fixing of Aluminium door with OEL anodized Al door section of 9202 as vertical member, 9201 as top member and 9200. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
25Supplying, fitting, fixing of fully glazed aluminium framed openable window using 15 micron anodized OEL aluminium section 2082 as out. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
26Supplying, fitting and fixing of M.S doors and windows shutters of approved design in proper position making good to the damages of walls. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
27Labour for fixing of M.S doors and windows shutters of approved design in proper position making good to the damages of walls of R.C.C or. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
28Painting two coats over a coat of primer with any approved paint with brush to wood/iron work including cost, conveyance, taxes of all the. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
29Providing fitting and fixing of false ceiling with aluminium anodised T section no. 3215 with 2' - 0\\" center to center, L section no. 1705 upto 15. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
30Providing and fixing Vitrified tiles in floors, treads of steps and landing on 20mm th bed of cement mortar (1:4) (1 cement:4 sand) joined with. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
31Providing and fixing Glazed tiles in dados, skirting and rises of steps on 12mm th cement plaster (1:3) (1cement:3sand) joined with. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
32Providing and fixing Chequered tiles in floors, treads of steps and landing on 25mm th bed of cement mortar (1:1) (1 cement:1 sand) joined with. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
33Providing and fixing Chequered tiles in dados, skirting and rises of steps on 12mm th cement plaster (1:3) (1cement:3sand) joined with. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
34Providing, fabricating, transporting and supplying at site of M.S. roof trusses and members etc. including all cost, conveyance, taxes of all. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
35Hoisting joists & trusses and placing in position etc. complete including all cost, conveyance, taxes of all the materials required for the work. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
36Providing, fitting and fixing of GCI sheets in roof including drilling holes in wind ties & fixing of ridges, vallies, wind ties etc. including cost. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
37COMPOUND WALLEarth work excavation in foundation hard soil including moorum, stoney earth mixed with boulders with all leads and. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
38Supplying, filling in foundation and plinth with sand in layers well watered and rammed including cost, conveyance etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
39Providing cement concrete (1:3:6) in foundation and plinth using 4cm size clean hard black granite metal of approved. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
40R.R.H.G stone masonry in cement mortar (1:6) in foundation and plinth with hard black broken granite stone of. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
41Cement concrete of proportion (1:2:4) using 12mm size hard granite chips of approved quality from approved quarry. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
421st class well Clamp Burnt brick masonry in cement mortar (1:6) in super structure using clamp burnt bricks of 23x11x8cm size. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
4312mm th Cement plaster in C.M (1:6) to brick work finished smooth including watering curing and scaffolding with. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
44Finishing walls with water proofing cement paint (Weather coat) of approved shade on new work two coats, over etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
45Supplying, fitting and fixing of M.S doors and windows shutters of approved design in Comp Gate. etc. Complete in all respect as per specificationand direction of the Enginineer in Charge
46Labour for fixing of M.S doors and windows shutters of approved design in proper Comp Gate.
47Painting two coats over a coat of primer with any approved paint with brush to wood/iron Comp Gate.
48C.C ROADEarth work excavation in foundation hard soil including moorum, stoney earth mixed with boulders with all leads and lifts including dressing and levelling the bed and depositing.
49Supplying, filling in foundation and plinth with sand in layers well watered and rammed including cost, conveyance, royalty of all the materials required for the work.
50Providing cement concrete (1:3:6) in foundation and plinth using 4cm size clean hard black granite metal of approved quality from approved quarry including hoisting, lowering.
51Cement concrete of proportion (1:2:4) using 12mm size hard granite chips of approved quality from approved quarry including hoisting, lowering and laying.
52PH. WORK30 User Septic Tank reapirSupplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 12 mm thick C.P in C:M (1:3) 2 x ( 3.12 + 1.93 ) m x 1.90 m =19.19 sqm + 3.12 x 1.93 m = 6.021 sqm + 4 x 0.40 x 0.60 m = 0.96 sqm
53Supplying all materials, labour, T&P and providing cement punning on plastered surface including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. Same as above item 20mm C.P in 1:3
54Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling them after casting including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the Engineer-in-charge.2 x (3.82 + 2.63 ) m x 0.125 m =1.612 sqm + 3.12 x 1.93 m = 6.021 sqm
55Supplying all materials, labour, T&P and providing M.S.reinforcements for RCC work including cutting, bending, binding, straightening and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the Engineer-in-charge.
56Supplying all materials, labour, T&P and providing Reinforced cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.3.82 m x 2.63 m x 0.125 m
57Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing etc all complete as per P.H specification and direction of the E.I.C. 110mm diameter U-PVC SWR pipes
58110mm U-PVC SWR P-trap
59110mm U-PVC SWR single junction door
60110mm U-PVC SWR door bend
61110mm U-PVC SWR Offset
62110mm U-PVC SWR plain bend
63110mm U-PVC SWR vent cowl
6475 mm diameter U-PVC SWR pipes
6575mm U-PVC SWR door bend
6675 mm U-PVC SWR plain bend
67125 mm dia C.P Grating
68Supplying all materials, labour, T&P and laying in trenches 4kg/cm2 U-PVC SWR soil waste ventilating pipes for sewer line of following dia in trenches (to slope or level)and jointing with supply of approved solvent cement by non-heat application method C.C (1:3:6) using 40mm size hard granite metal on bed of the trenches and all round concrete encashing with C:C (1:4:8) using 40 mm size H.G. metal, earthwork in excavation in trenches in all kinds of soil, refilling the same in a layer of 0.30mtr with watering, ramming and removing of surplus earth, testing the S.W. pipeline etc. all complete as per approved drawing, specification and direction of the E.I.C. 160 mm dia PVC Pipe all round
69110 mm dia PVC Pipe all round
70Supplying all materials, labour, T&P and providing, laying soakway gallary with SW/PVC pipes, jointing lead loose packed allround with stone boulders 50mm to 150mm other than granite, covered at top with a layer of flat tiles 300mmx300mmx25mm including earthwork in excavation of trenches in all kinds of soil to an average depth of 1.5 mtr, covering of earth at the gallary top etc. all complete as per approved drawing and direction of the E.I.C. 160 mm dia PVC gallary
71Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, 1st class KB Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, earth work excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved specification and direction of E.I.C Inside size 760mm x 760mm x 460mm
72Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8 cm thick precast cover slab in CC (1:2:4) mix using 12 mm size H.G chips, foundation concrete (1:4:8) using 40 mm size HG metal on bed and around trap , !st class KB Brick work in CM (1:6) in F & P and inside 12 mm thick cement plaster (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap 150mmx150mm size C.I grating etc. all completed as per approved drawing, specification and direction of E.I.C.
73Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class KB brick work in CM (1:6) for the remaining height at top, 12mm thick Cement Plaster (1:4) inside and outside over masonry brick work, gravel packing in the rear of well steining, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C. 0.90 m dia x 2.00 m deep Soakway pit
74Supplying all materials, labour, T&P and Fitting and Fixing of Rotational moulded polythene cylindrical vertical water storage tank conforming to 15701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5 mtr above G.Land placing the tank in required position including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 2000 lits capacity on the roof of G. floor
75Supplying all materials, labour, T&P and construction of masonry staging with providing 1st class K.B. Brick work in C.M.(1:6) of 0.46mtr height in staging, 12 mm cement plaster in C.M (1:6), R.C.C. Beam of 0.25mx0.30mx2.60m & roof slab of 1.40mx1.40m in C.C (1:1.5:3) using 12mm size H.G.Chips including centering, shuttering, bending and binding of rod etc watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 2000 lits capacity on the roof of G.floor
76Supplying all materials, labour, T&P and fixing porcelain glazed tiles in floors, on 25mm thick bed of cement mortar 1:1 joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. all complete as per specification and direction of the E.I.C. G.F 1x1.20x1.95m = 2.34 sqm + 1x1.20x3.04m = 3.648 sqm + 1x3.04x4.57m = 13.892 sqm + 3x0.75mx0.30 m = 0.675sqm - (-1)x 0.58m x 0.44m=0.255
77Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados/skirtings on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing etc. all complete as per direction of the E.I.C. G.F 1x5.74mx2.10m =12.05 sqm + 1 x7.88m x 2.10m = 16.548 sqm + 1 x14.62m x 2.10m = 30.70 sqm + 1x 8.0m x 0.90m= 7.20 sqm
78Supplying all materials, labour, T&P and fixing water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest etc all complete as per specification and direction of the E.I.C.580mm size Orissa pan(Hindware,Parryware)
79Supplying all materials, labour, T&P and fixing wash down water closet(E.W.C) with integral 'S' or 'P' trap(Hindware,Parryware,Cera) to the floor with wooden plug and C.P screw including jointing the trap with soil waste pipe in C.M(1:1) etc all complete as per specification and direction of the E.I.C. Anglo Indian water closet(E.W.C) with 'P' trap plain
80Supplying all materials, labour, T&P and fixing of plastic seat cover for E.W.C with chromium plated brass hinges and rubber buffer etc all complete as per specification and direction of the E.I.C.
81supplying all materials, labour, T&P and cutting holes through existing brick/stone masonry walls for taking HCI/PVC pipes and fittings including making good the damages in cement mortar (1:4) etc. all complete as per P.H. specification and direction of E.I.C.375 mm thick wall
82250 mm thick wall
83Supplying all materials, labour, T&P and providing and fixing to wall or ceiling or floor G.I. pipes and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling,and floor, testing all complete as per specification and the direction of the E.I.C.15mm dia C-PVC pipes
8420mm dia C-PVC pipes
8525mm dia C-PVC pipes
8632mm dia C-PVC pipes
87Supplying all materials, labour T&P and fitting and fixing of C.P Shower(Jaquar Make) with 15mm or 20mm inlet with C.P Shower arm including polishing etc all complete as per specification and direction of the E.I.C15 mm x 150mm dia C.P Shower with arm
8815 mm dia C.P Health Faucet ( Jaquar Make )
89Supplying all materials, labour, T&P and fitting and fixing Brass/CP fittings(Jaquar Make) of the following nominal bore with supply of all jointing materials etc. all complete as per specification and the direction of the E.I.C.15mm dia CP Bib Cock
9015mm dia CP long body Bib Cock
9115mm dia CP Bib Cock with long nose elbow action
9215mm dia CP Two way angle/Bib Cock
9315 mm dia CP Angle cock
9415mm dia CP Concealed Stop Cock
9515mm dia CP Pillar Cock
9615mm dia CP nipple
9715mm dia CP Flange
9825mm dia Metal Full Way Valve
99Supplying all materials, labour T&P and fixing wash basins(Hindware,Parryware,Cera) with C.I. or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the E.I.C.550mmx400mm W.H.basin
100Counter top basin 560 x 455
101Supplying all materials, labour, T&P and fixing pedestrial for wash hand basin complete recessed at the back for the reception of pipes and fittings etc all complete as per specification and direction of the E.I.C. Porcelain Pedestal
102Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the E.I.C.Mirror with plastic moulded frame
103Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the E.I.C20mmx450mm long CP towel rail
104CP towel ring
105Supplying all materials, labour, T&P and fixing Stainless Steel kitchen sink/laboratory sink with C.I/M.S brackets paintedwhite including holes in walls and making good the damages fixing PVC waste pipe of 32mm nominal diameter including brass check nut complete, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the E.I.C. stainless steel kitchen sink
106Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the E.I.CCP soap holder
107Providing fitting fixing Al door with anodized Al door section of 9202 as vertical member, 9201 as top, 9200 as bottom and middle member with frame section as 9221 with tapered clip no 4660 and frame to be completed by means of jointing angle no 1855 including cost of labour T&P hire charges of drilling machine labour charges etc complete with cost of laminated board. and as per direction of the Engineer in charge. 5 x 0.72m x 1.95m= 7.02 sqmt
108Supplying all materials, labour T&P and fitting and fixing 10 Ltrs capacity PVC low level flushing cistern(Hindware,Parryware,Cera) with a pair of C.I. or M.S.brackets complete with fittings such as syphonic arrangement, 15mm nominal size Brass/PVC ball valve with polythene float, CP/Brass handle, unions and couplings for connection with inlet, outlet, overflow pipes, 32mm dia PVC flush bend, 15mm dia PVC connection pipes including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main with etc all complete as per specification and direction of the E.I.C 10 lit PVC L/L Cistern
109ELECTRICAL WORKRecessed wiring to Light point/Fan point/Call Bell/Exhaust Fan Point with 1.5 sqmm, FR PVC Insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduct with 5 Amp. 250 V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size, MS box with 1.5 sqmm FR PVC insulated single core multistrand copper conductor and earth wire incouding all accessories and connection as per direction of engineer in charge (Make of wire Finolex/L&T/Anchor/V-Guard) deducting the cost of 2M Box with cover Plate-1 No.)(1.1.1-1.24.2)-do-Group A
110(1.1.2-1.24.2)-do-Group B
111(1.1.3-1.24.2)-do-Group C
112S/F of Angle holder replacing Ceilling Rose
113S/F to 16/18 SWG Modular GI box of following sizes (normal size) in recess with suitable size of Modular Base & Cover in front including cutting the wall and making good the same in case of recessed conduit as required.for 2 Module (1.24.1)do 4 Module
1146 Module
115do 8 Module
116do 12 Module
117do 18 Module
118S/F of 5/6 Modular Switch & 3pin 5/6A Modular Socket on existing board (1.25.1+1.25.4)
119S/F of Extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp piano type modular switch, connection, painting etc as required.
120S/F of Power point with 4 modular & 2 modular metal box with modular base & cover in recess including providing and fixing of 32A DP Modular Switch with neon Indicator & 5 pin 15/16 amp. piano type Modular Socket & Mini DP MCB, connection, painting etc as required for AC
121S/F of 1 no of 5 pin 15/16 amp. Modular Socket, 1 no of 15/16A Modular switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection
122S/F of computer board consisting of 3 nos of 5amp modular plug and modular switch & 1 no of Mini MCB complete with wiring on 12 modular M.S. box with modular cover.
123S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required
124Wiring for circuit/sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire Finolex/L&T/Anchor/Havels/V-guard)2x1.5+1x1.5 (1.8.1)
1252x2.5+1x1.5 (1.8.2)
1262x4+1x1.5 (1.8.3)
1272x6+1x2.5 (1.8.4)
128Inverter wiring (1x1.5smm) Copper wire (1.19.1)
129S/F of 'B/C/D' series SP MCB of 5-32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1)
130S/F of 'B/C/D' series DP MCB of 5-32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required (2.6.2a)
131Supply and fixing of following size MCB box with sheet steel enclosure, distribution board, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland/plate, interconnection, phosphate and powder painted including earthing etc. as required (But without MCB/RCCB/ISOLATOR)6 way Single door (2.3.1(a) + 2.3.1(b))
1328 way Double door (2.3.6)
133Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following capacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/HPL/Anchor/L&T /Havels/C&S/R. K.)S/F of 63A ICDP main switch with MS box of 250mmx300mmx60mm deep ((2.15A)+(1.24.16)
134Earthing with G.I. Earth pipe 3 mtr Long 40mm dia ISI marked including accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe with charcoal & salt as required (3.2)
135Supply & laying 8 SWG Cu wire in recess for loop earthing as required (3.18)
136Supply and fixing of 300mm Exhaust fan with all accessories and connections (Make:Usha-Aero Clean Plus DBB/Crompton-Trans Air 12\\" reversible /Havells-Venti Air DS (HS)/Anchor- Anmol delus R/Orient-Power Flow DBB// Pollycab -Fresh on DBB)
137S/F of Call bell/Buzzer(Ding dong type) ISI marked suitable for DC/AC single phase 230 volts complete as required. (1.30)
138S/F of 18-25Watt LED Tube light fitting with all accessories and connections (Make:HPL/ Havells/PAC/Crompton/Polycab)
139Supply and fixing of 1200mm A.C. Ceiling fan (1 star) with all accessories and connections with out fan regulator (Make:Usha-Striker neo HS/Crompton-Highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/Great White - Aldous/Pollycab - Vital HS)
140S/F step type modular fan regulator
141Supply and fixing of 400 mm wall fan with all accessories and connections (Make:Usha-Maxx Air Ultra/Crompton-WM Hiflow wave /Havells-Accelro (HS)/Anchor- Altrix HS-OWH/Orient-Wall 43/Great White WYNO WF/Pollycab-Aery HS)
142S/F of 10w Watt LED Bulb
143S/F of portico lamp.
144Provision of Armoured cable size 2x6sqmm (15)
145Supply & fixing of 63A TPN Panel board 1. 63A MCCB (Make-Legrand/Seimens/L&T/C&S/)2. 63A kitkat & bus bar3. 32A DP MCB-4 nos4. 63 A 4P load changeover switch (Legrand/Seimens/L&T/C&S)- 1 nos5. Digital Volt meter & Ameter three phase6. All accessories & Connection (Rating & Danger board) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57451149
AUTHORITY Government Departments
TENDER VALUE 75.84 Lakhs
LAST DATE 22-09-2026
Authority
Authority Name Rural Works Department
Work Description Tender for Repair And Maintenance Of Phc (Ama Hospital) Building At Judabali For The Year 2025-26
Basic Detail
Tender No Online Tender- 07/SERWDBLG/2026-27
Bidding Type Tender
Location
City Kandhamal
State Odisha
Key Dates
Publish Date 10 Sep 2026
Submission Date 22 Sep 2026
Open Date 23 Sep 2026
Finance
Tender Value 75.84 Lakhs
Tender Fee 10000
EMD 75850
Exemption Available
Document List
BOQ_609171.xls
dd0f83c5-5d81-4085-8031-4f6f91438018.html
Tendernotice_1 (19).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_609171.xls

html

dd0f83c5-5d81-4085-8031-4f6f91438018.html

pdf

Tendernotice_1 (19).pdf

pdf

Tendernotice_2.pdf