Tender For Annual Plan-Akalakkunnam Gp Project No:310/26-Motor Installation - Kdakkuzhy Sc Colony Drinking Water Project-General Electrical Work
Tender Value
1.65 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
11 days left
EMD
4141
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kottayam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Plan-Akalakkunnam Gp Project No:310/26-Motor Installation - Kdakkuzhy Sc Colony Drinking Water Project-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Kdakkuzhy DWSS (Approved List of Materials Uploaded in Attachments & is Part of Tender/Agreement Document) |
| 2 | OD536835/2025-2026:Supply Conveyance Installation, testing & commissioning of 440V,50Hz Bore well pump set of Deccan EKKI make model -ER61/15,7.5HP 15 stage pump of Head Range-92 to 150mtr,Discharge of 225 to 100lpm and 50mm outlet or equivalent spec models. |
| 3 | OD536834/2025-2026:Supply Conveyance Installation of BCH make DOL Starter of 7.5HP Borewell Motor of range 13 to 20A |
| 4 | OD536830/2025-2026:Supply & Laying HDPE pipes PE 100,12.5Kg,63mm Outer dia |
| 5 | 90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm |
| 6 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 7 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm |
| 8 | 1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm |
| 9 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 10 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 11 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 12 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 13 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 14 | OD536825/2025-2026:Supply and fixing the following Power capacitors three phase delta connected in position and giving connection |
| 15 | OD536824/2025-2026:Supply and providing 63A HRC fuse with fuse holder and giving connection as required |
| 16 | OD536827/2025-2026:Supply and fixing 63A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter board and giving connections etc. |
| 17 | OD536826/2025-2026:Supply and fitting 63 mm Non Return Valve using required bolt and nut and flange etc |
| 18 | OD536823/2025-2026:Supply and fitting 63 mm KARTAR Sluice valve CI on existing GI pipe with flanges etc |
| 19 | OD536829/2025-2026:Supply and fitting 63 mm GI Bend on pumping main with flanges welded and nut bolt etc on pumping main. |
| 20 | OD536831/2025-2026:Supply and installation of Pressure meter with accessories and stopper valve, ball valve etc on delivery side of 63 mm GI pipe line as required |
| 21 | OD536832/2025-2026:Supply and fitting 63 mm flange with bolt and nut duly welded |
| 22 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysSep 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender