Housing Urban and Rular Development Boards / Undertakings / PSU Closing in 15 days TDR #57450456

Tender For Construction Work Of Chief Minister Model Composite School (Phase-2) In District-Mathura

Issued by Boards / Undertakings / PSU · Mathura, Uttar Pradesh
Tender Value
19.90 Crore
Estimated cost
Bid Submission
06 Oct 2026
15 days left
EMD
39.80 Lakhs
Bank guarantee accepted
Document Fee
8850
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mathura → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Work Of Chief Minister Model Composite School (Phase-2) In District-Mathura

BOQ

Name of Work:- Construction work of Chief Minister Model Composite School (Phase-2) in District-Mathura
Sl. No. Item Description
1Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, for all Lifts, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. All Kinds of Soil.
2Earth work in excavation by mechanical (Hydraulic excavator)/ manual means over area (exceeding 30cm indepth, 1.5Mtr. in width as well as 10 SQM. on plain) including getting out and disposal of excavetd earth lead upto 50Mtr. and lift upto 1.5Mtr., as directed by engineer-in-charge. All Kind of Soil.
3Earth work in excavation by mechanical (Hydraulic excavator)/ manual means over area (exceeding 30cm indepth, 1.5Mtr. in width as well as 10 SQM. on plain) including getting out and disposal of excavetd earth lead upto 50Mtr. and lift upto 1.5Mtr., as directed by engineer-in-charge. Extra for every additional lift 1.5 Mtr. or part thereof in excavation/blinking excavated are stacked material
4Earth work in excavation by mechanical (Hydraulic excavator)/ manual means over area (exceeding 30cm indepth, 1.5Mtr. in width as well as 10 SQM. on plain) including getting out and disposal of excavetd earth lead upto 50Mtr. and lift upto 1.5Mtr., as directed by engineer-in-charge. All Kind of Soil upto 3Mtr. to 4.5 Mtr. depth
5Earth work in excavation by mechanical (Hydraulic excavator)/ manual means over area (exceeding 30cm indepth, 1.5Mtr. in width as well as 10 SQM. on plain) including getting out and disposal of excavetd earth lead upto 50Mtr. and lift upto 1.5Mtr., as directed by engineer-in-charge. All Kind of Soil upto 4.5Mtr. to 6.0 Mtr. depth
6Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, for all Lifts, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. All Kinds of Soil upto 1.5 M to 3.0M Depth
7Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors.
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
10Providing and laying in position cement concrete of specified grade base excluding the cost of centering and shuttering 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources)
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
12Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
13Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floorWith Chlorpyriphos/Lindane E.C. 20% with 1% concentration
14Reinforced Cement Concrete work in RCC Culvert slab with 1:2:4 (1 cement 2:coarse sand : 4 graded stone aggregate of 20MM nominal size excluding centerring and shuttering and reinforcement.
15Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR LINTEL] M-20.
16Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR SUNSHADE] M-20.
17Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete)
18Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) for slabs (Using 1:1.5:3 Mix concrete)
19Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete)
20Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). in R.C.C. columns in 1:1.5:3 having strength not less than M-20.
21Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 330 kg /cum Water tank
22Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete.All works upto plinth level Concrete of M30 grade with minimum cement content of 330 kg /cum Water tank
23Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
24Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand)
25Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in .foundation and plinth in :Cement mortar 1:4 (1 cement : 4 coarse sand)
26Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
27Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
28Providing and fixing anodised aluminium grill (anodised transparentor dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approvedstandard section and fixed to the existing window frame with C.P.brass/ stainless steel screws @ 200 mm centre to centre, includingcutting the grill to proper opening size for fixing and operation ofhandles and fixing approved anodised aluminium standard sectionaround the opening, all complete as per requirement and directionof Engineer-in-charge. (Only weight of grill to be measured forpayment).
29Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
30Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Kiln seasoned and chemically treated hollock wood
31Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face venners on both faces of shutters 35 mm thick including ISI marked Stainless Steel but hinges with necessary screws
32Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face venners on both faces of shutters 35 mm thick Double leaf
33Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face venners on both faces of shutters 35mm thick Single leaf
34Mild steel or iron work for Fabrication of hold fast for door chaukhats and windows.
35Mild steel or iron work for Fabrication of M.S. Grill
36Mild steel or iron work for Fabrication of M.S. Z-section window and ventilators
37Mild steel or iron work for Fabrication of M.S. Angle iron 40x40x5 mm
38Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
39Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
40Providing and fixing fly proof galvanized M.S. wire guage to windows and lerestory windows using wire guage with average width of aperture 1.4mm in both directions with wire of dia 0.63mm all complete with 12mm steel U beading
41Providing and fixing fly proof wire guage to windows and lerestory windows and Doors with M.S. Flat 15x3 mm and nuts and botls complete Stainless Steel (grade 304) wire guage of 0.5mm dia wire and 1.4mm aperture on both side
42Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia
43Fixing of steel or wooden chaukhats in position. (a) Door chaukhats
44Fixing of steel or wooden chaukhats in position.(b) Window chaukhats
45Fixing of steel or wooden chaukhats in position. (c) Ventilator chaukhats
4615mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand)
4712mm thick plaster with cement mortar in proportion of 1:6 cement & Coarse sand
4812mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand on Ceiling and Soffits of stairs upto Floor Two Level
4915mm thick plaster wit cement mortar in proportion of 1:6 cement & Coarse sand)
5020mm cement plaster 1:3 (1 cement : 3 Coarse sand) finished with of floating coat of neat cement
51Making grooves 10 to 12 mm widex 8mm deep in plaster of the wallor in ceiling vertically or horizontally as required.
52Making drip course in sun shade or facia as per direction of Engineer incharge including supply of all materials,labour T & P etc for proper completion of the work. Excluding GST
5325 mm thick 1:2:4 cement concrete floor with cement approved coarse sand & 2cm graded dala stone grit laid in planels finished with 3mm floating coat of neat cement bor cement and marble dust in ratio of 5:1 as specific over and excluding base concrete and removing any overlapping mortar at the joints of the panels if any giving them a uniform finish, including supply of all materisls labour, T&P etc. required for proper completion of work
5440mm thick 1:2:4 cement concrete floor with cement approved coarse sand & 2cm graded dala stone grit laid in planels finished with 3mm floating coat of neat cement bor cement and marble dust in ratio of 5:1 as specific over and excluding base concrete and removing any overlapping mortar at the joints of the panels if any giving them a uniform finish, including supply of all materisls labour, T&P etc. required for proper completion of work
55Providing and fixing 18mm thick gang saw cut, mirror polisged, permoulded and prepolished, machine cut for kitchen platforms, vanity counters, windows sills, facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated white cement, mixed with matching pigment, epoxy touch usp, including rubbing, curing, moulding and polishing to edgesto give high gloss finish etc. complete at all levels. Granite Stone slabs of colour black, Cherry/Ruby Red area of slab over 0.5 SQM
56Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN FLOORING]
57Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN SKIRTING]
58Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete. In flooring and Walls
59Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. [IN FLOORING]
60Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. [IN SKIRTING]
61Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
62Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
63Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long,
64Painting Wood work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
65Cement Plaster skirting up to 30 cm height, with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement, 18mm thick
66Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two ro more coats on new work over an under coat of suitable shade with ordinary paint approved brand and manufacture
67Finishing walls with water proofing cement paint of required shade : New Work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat.
68Fabrication and supply of T-iron 40x40x5mm door/window chaukhat frame including cost of steel, all carriage welding cutting, labour, grinding smooth finishing, staple plate 6 mm thick welded in back flange at hinges cost of 14 gauge hinges for 50mm size including all drilling, machine threading all screw, nuts, bolts, arrangment for looking of tower bolt, tie roo, hold fasts made of 25x3mm flat iron 15 cm long complete job including applying of one coat of red oxide steel primer paint required for proper completion of the work as per direction of Engineer in charge standard weight of actual weight ever is less than to be paid.
69Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
70Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacture's specifications including appropriatepriming coat, preparation of surface, etc. complte On steel work
71Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre .
72Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm :
73Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
74Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm).
75Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm
76P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 250 mm x 10mm
77P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 150x10mm
78Providing & fixing stainless steel door handles with screws and 150mm long.SI marked
79Making drain along with apron.
80S/F of glass strips for flooring.35mm wide & 4 mm thick
81Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
82Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (Zone III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources).
83Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
84Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
85Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
86Providing and fixing fly and Mosquito proof stainless steel grade 304 wire mesh gaugewith 0.5 mm dia wire and 1.4 mm wire aperture
87Providing and fixing wire gauge shutters using With ISI marked stainless steel butt hinges required sizeof aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :32mm thick shutters With ISI marked stainless steel butt hinges of required sizeSecond class teak wood
88Expension joint teatment with 1.02 mm thick aluminium sheet and 4 cm thick bitumastic sheet with hot bitumen of approved aulity. (As per Rate analysis & specification attached) HORIZONTAL EXPANSION JOINT
89Providing & fixing aluminium sheet ,1.02 mm thick for Vertical expansion joint work including labour and all materials etc . Powder coated aluminium (minimum thickness of powder coating 50 micron) VERTICAL EXPANSION JOINT
90Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
91Centering and shuttering including strutting, propping etc. and removal of form for all heights Foundations, footings, bases of columns, etc. for mass concrete.
92Centering and shuttering including strutting, propping etc. and removal of form for all heights Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick.
93Centering and shuttering including strutting, propping etc. and removal of form for all heights Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick
94Centering and shuttering including strutting, propping etc. and removal of form for all heights Columns,Pillars, Piers, Abutments, Posts and Struts.
95Centering and shuttering including strutting, propping etc. and removal of form for all heights walls (any thickness) including attached plaster butteresses plinth and String courses etc.
96Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
97Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
98Providing and fixing Alumunium sliding door bolts ISI marked to required colour or shade with nuts and screws etc. complete :300x16 mm
99Providing and fixing Alumunium tower bolts with necessary screws etc. complete 300 mm x 10mm
100Providing and fixing Alumunium tower bolts with necessary screws etc. complete 250 mm x 10mm
101Providing and fixing Alumunium handles with screws etc. complete (a) 125 mm
102Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16mm
103Providing and fixing ISI marked oxidised M.S. tower bolts black finish. (Barrel type) with necessary screws etc. complete:
104Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125mm
105Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
106Providing and fixing aluminium hanging floor door stopper. ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
107Chequerred precast cement concrete tiles 20 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
108Providing and fixing anodised aluminium doors,having 2 mm thick Aluminium section excluding coating & an average coating of 20 micron fully glazed made of Aluminium door tube size 83.5x44.65 mm as Vertical member and 11.40x44.45mm size tube in bottom & horizontal members Door chaukhat ahould be ofAluminium tubler vertical with two openable shutter. The rate will include cost of material fixture 5mm glass handles,locks,screw necessary beeding & excluding cost of floor spring if requred for proper complection of work as per direction of Engineer-in-charge. With 5 mm thick glass
109Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 1.0 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
110Supply and filling of cinder in sunken in portion of building including breaking into required sizes including supply of all material, labour T&P required for proper completion of the work.
111Providing and Fixing cup board shutters using with 25mm thick vineered particle board IS : 3097 marked, exterior grade (grade I) of approved make, including Iind class teak wood lipping of 25mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hings, complete as per direction of Engineer-In-Charge
112Aluminium sheet 26 gauge
113Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.
114Providing and fixing C.I. tee at the inlet and outlet of septic tank.
115Providing & fixing 75mm dia vent pipes.
116Providing & fixing of 75mm dia cast iron terminal guard.
117Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality M.D. -10- Circular shape 500mm internal diameter
118Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality M.D. -2.5- Circular shape 450mm internal diameter
119Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality L.D. -2.5- Rectangular shape 600x450mm internal diameter
120Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks
121Supply and fixing M.S. Work in gate 'including all necessary for proper 'completion of the work.
122Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
123Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including colle cting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level .Drilling of 300mm dia bore hole manually.
124Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire& labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia
125Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
126Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge.
127Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
128Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in- charge.
129Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Dumb bell with central bulb (180 mm wide, 8 mm thick)
130Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @ 0.70 kg per sqm
131Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
132Laying of CC Road M-25 with ready mix concrete
133Providing and laying factory made champhered edge cement concrete paver block with earth work, PCC (1:4:8), brick work (1:6) and preperation of subgrade etc.
134Providing, stacking and Displaying Topiary plant of Ficus Panda welldeveloped with fresh & healthy foliage with 3 to 4 Ball and 60 cm to 75cm spread each Ball, 135 cm to 150 cm ht. plant, in 35 cm CementTray /Cement Pot/ Plastic Pot and as per direction of the officer-incharge. DSR LANDSCAPING & HORTICULTURE-2025 (5.40)
135Providing and stacking of Hamelia patens of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge. DSR LANDSCAPING & HORTICULTURE-2025 (8.31)
136Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-incharge. DSR LANDSCAPING & HORTICULTURE-2025 (6.12)
137Providing and stacking of Plumeria alba of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge. DSR LANDSCAPING & HORTICULTURE-2025(7.69)
138Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. DSR LANDSCAPING & HORTICULTURE-2025 (6.31)
139ELECTRICALWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
140Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
141Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
142Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire)
143Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)
144Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2 X 4 sq. mm + 1 X 4 sq. mm earth wire)
145Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2 X 6 sq. mm + 1 X 6 sq. mm earth wire)
146Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2 X 10 sq. mm + 1 X 6 sq. mm earth wire)
147Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (4 X 10 sq. mm + 2 X 6 sq. mm earth wire)
148Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (4 X 16 sq. mm + 2 X 6 sq. mm earth wire)
149Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
150Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
151Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
152Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
153Supplying and fixing Single Pole blanking plate in the existing MCB DB complete etc.as required.
154Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
155Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2 Way 5/6 A switch
156Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
157Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV socket outlet
158Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. RJ45 socket cat 6 with shutter
159Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. DATA Outlet
160Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
161Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
162Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm)
163Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mm X75mm)
164Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
165Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioningetc. as required 40 amps 4P MCB
166Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. As required. 25 amps
167Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required. Single pole 6-32Amp C Curve
168Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kv grade as required. 150 sq. mm 3-1/2 core
169Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
170Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16 A modular switch, connections etc. as required.
171Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/wooden block including connections etc. as required.
172Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
173Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
174Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
175Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable
176Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
177Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing andfixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
178Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) 4 way , Double door
179Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
180Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) 12 Way, Double Door
181Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
182Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 12), Double door
183Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
184Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
185Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door
186Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For 4 Way, Double Door TPN MCBDB
187Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
188Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
189Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 A, 16 KA,TPMCCB
190Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
191Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
192Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
193Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Four Pole
194Supplying and fixing 40/63A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Three poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent.
195Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
196Supplying and fixing 40/63A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent.
197Supply and Laying of Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (150 Sq. mm 3-1/2 Core)
198Supplying and installing following size of perforated paintedwith powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
199Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
200Earthing with G.I. earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
201Supply and laying of 25mm x 5mm copper strip at 0.50 meter below ground as strip earth electrode including connection / terminating with nut ,bolt spring washer etc. jointing shall be done by overlaping and with 2 sets of brass nut bolt&spring washer spaced at 50mm)
202Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
203Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
204Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
205Earthing with G.I. earth Pipe 4.5 Mtr. Long 40 mm dia including Accessories, and providing Masonry enclosure with cover plate heaving locking arrangement and watering pipe etc., with charcoal, coke, and salt. as required.
206Supply of 8W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent.
207Supply of 15W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent.
208Supply of 26W Smart Bright Linear provides an extremely durable and high efficacy yet cost effective linear solution surface mounted and suspended applications like offices, retail stores, metro stations, etc. similar to Philips SP095V LED26S 865 W7L120 PSU WH or equivalent.
209Supply of 40W Smart Bright Linear provides an extremely durable and high efficacy yet cost effective linear solution surface mounted and suspended applications like offices, retail stores, metro stations, etc. similar to Philips SP095V LED40S 865 W7L120 PSU WH or equivalent.
210Supply and fixing of LED Tube Light with heavy duty Metal Box type Mirror Light fitting 10 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended Complète in all respect
211Supply and fixing of wall bricket 10 watt LED bulb Polycarbonate tube light complete Including tube suitable for both surface & suspended Complète in all respect
212Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
213Supply and fixing of Ex-fan 200 mm Complete in all respect
214Supplying installation testing and commissioning of 450mm sweep 1500 RPM heavy Duty Exhaust Fan
215Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (36 Watt)
216Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (40 Watt)
217LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified GlareRating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LEDfixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . (12-15 Watt)
218LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified GlareRating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LEDfixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . (18 Watt)
219Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (18-22 Watt)
220Supply of Pressure die cast housing LED bulkhead with IP66protection and IK09 impact resistance suitable for surface and wall mounting applications. Similar to Philips Cat Ref. WT202W LED6S NW PSU S2 PC or equivalent.
221Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm,3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 19884CX16Sq.mm Cable
222Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm,3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 1988 3.5CX35Sq.mm Cable
223Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm,3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 1988 3.5CX50Sq.mm Cable
224Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm,3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 1988 3.5CX95Sq.mm Cable
225Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm,3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 1988 3.5CX150Sq.mm Cable
226Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm,3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 19883.5CX240Sq.mm Cable
227Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
228Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm)
229Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 95 sq. mm (45mm)
230Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 240 sq. mm (62mm)
231Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm
232Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
233Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm
234Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
235Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
236Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.300 mm dia
237Supply & fixing of water tight-oblong 10 watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK 08, High purity/ transmisivity UV Stabilized Non yellowish diffuser/ for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24
238Supply and fixing of LED Tube Light with heavy duty Metal Box type Tube Light fitting 1x22 watt suitable for upto 1x 22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect
239Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
2403 Phase Input & 3 Phase Output 10KVA UPSSupply, installation, testing, and commissioning of UPS system with following features 1. High freq. PWM inverter using IGBT 2. Manual/Auto bypass switch3. SMF batteries to provide approx. 30 min backup time on IT load alongwith battery rack
241Suplly and burring of safe Earthing Electrode T-39 Cu Copper Coated, Length 2000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reucing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame withhinged cover & mansonry housing.(From electrode terminal to switch board, cost of 25x3 copper strip will be extra) Make: As approved in U.P.P.W.D & C.P.R.I. all respects.
242Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thik) having 3mm thikness with Single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect.
243Supply and fixing of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 and above protection complete in all respect.(Ed e Plus LED Streetli ht)
244Supply installing testing & commissioning of LED Bollard offers a high level of durability with high impact resistance. It is easy to install, comes with ingress protection and provides comfortable soft lighting BGBOL 605 9W LED LED BOLLARDS
245Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 2 X 6 sq. mm
246Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 4 X 10 sq. mm
247Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3½ X 50 sq. mm
248Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3½ X 120 sq. mm
249Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3½ X 150 sq. mm
250Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required,but excluding sand cushioning and protective covering. Upto 35 sq. mm
251Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required,but excluding sand cushioning and protective covering. Above 95 sq. mm and upto 185 sq. mm
252Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
253Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
254Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
255Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Above 95 sq. mm and upto 185 sq. mm
256Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
257Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
258Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 2 Core 6 sq.mm
259Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 50 sq. mm
260Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 120 sq. mm
261Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 150 sq. mm
262Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB’s (Four Pole 36 KA with thermal magnatic release) Switches complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB’s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A & B only. All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this sectionThe minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mmPhase to neutral-minimum 15mmCubical Panel Board ( MCCB Type)Main L.T. Panel (Meter Panel Board)Incoming :- One (1) No.200Amp. MCCB-1No.Metering :- One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etcOne (1) Set of Phase Indication Lamp.Bus Bar :- One (1) No.200 A, TPN aluminimum bus bar of suitable length.Outgoing :- Phase indication lamps on each outgoing to be provided.100 Amp. MCCB- 1 No. 63 Amp. MCCB- 3 No. Or outgoing as per site requirment(AS/SLD)
263MAIN L.T PANELDesign, Manufacturing, Supply, Commissioning & Testing of Main LT Panel. The panel will be totally enclosed type with, free standing, floor mounted, indoor duty, dust & vermin proof, , front operated, electrical panel fabricated from 2 mm thick M.S. Sheet as per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CT's, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness.The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have AMF facility to achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases over 250A & thermal magnetic release below 250A. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 35 MVA.INCOMMER500Amp. 16KA FP With S/C, U/V, E/F Protection MCCB-1 no.160Amp. 16KA FP With S/C, U/V, E/F Protection MCCB-2 no.160Amp. 16KA FP Auto Changeover For Emmergency ConditionBUSBARS1 Nos. 400 Amp FP busbars of aluminium alloy as per SLD.OUTGOING32Amp. 10KA FP MCB 4 No.63Amp. 10KA FP MCB 4 No.63Amp. 10KA FP MCCB 4 No.100Amp. 10KA FP MCCB 4 No.160Amp. 10KA FP MCCB 4 No.INSTRUMENTS2 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power factor on incoming from transformers with RS 485 port.2 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).2 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).2 Sets auto trip indicating lamp .
264The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have AMF facility to achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases over 250A & thermal magnetic release below 250A. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 35 MVA.INCOMMER- 1 Nos. 400Amp. F Protection MCCB, 1 Nos. 125 Amp. ACB BUSBARS- 1 Nos. 500 Amp TPN busbars of aluminium alloy as per SLDAUTO OPERATION OF INCOMMER/BUSCOUPLER ACB's'.Load Management through PLC Contractor for Load Management SystemBuscoupler switching Interlocking OUTGOING4 No. 125 Amp. TP MCCB, 4 Nos. 63 Amp/ TP MCB, 3 Nos. 40 Amp. TP MCBINSTRUMENTS3 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power factor on incoming from transformers with RS 485 port.3 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).3 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).3 Sets auto trip indicating lamp .NOTE: All outgoings should have Ammeter and RYB indications with backup MCB and indicated in single line diagramRELAYS AS PER SLD.
265EXTERNAL LIGHT FEEDER PILLARSupply installing testing & commissioning of out door type street light feeder pillar (Distribution Panel) compartmentalised design, dust tight & vermin proof made out of 14 gauge M.S. sheet, stove powder coated complete as required with following incomming & outgoing as per detail below.Incoming63 Amp. 10 KA FP MCCB 1 No.Suitable contractor and timer for down & dusk100 Amp. TPN Alu. Bus barOutgoing25 Amp. 10KA DP MCB 6 No.
266SITC of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290(Make : Newage/Minimax/Safex/Firex)
267SITC of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Newage/Jayshree/CRC)
268SITC of Short Branch Pipe as per IS:903(Make : Newage/Safex/Firex)
269SITC of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle
270Providing and fixing MS Pipes conforming to IS:1239 (Medium- B class) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required, cutting holes and chases in brick or RCC walls and making good complete. (For Riser) 100mm dia
271Supply, installation, testing and commissioning of Manual Swing Type First aid Fire Hose Reel 40m conforming to IS: 444 complete with all other necessary fixing accessories.
272Supply of Fire Man Axe.
273Providing and fixing weather proof standard Fire Duct Door complete in all respect for internal.
274SITC of Air cushion Tank (2000x1000)mm.
275SITC of Air Release Valve.
276Supply, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts. 150 mm
277SITC of Butterfly Valve complete with all respect. 150 mm
278Supply, Installation, Testing & Commissioning of Pressure Gauge with gauge cock DSR-30.8
279Supply, Installation, Testing & Commissioning of Fire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet.2 way
280Supply, fixing , testing & commissioning of electrical motor driven fire pump suitable for automatic operation consisting of following : (Terrace Pump) (Make : Kirloskar/Mather+Platt) (a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head. The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically. The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.(b) Squirrel cage, TEFC induction motor suitable for 415 V, 3 phase having IP 55 protection and class 'B' insulation for the above pump and flexible coupling with the pump. The motor shall b rated for continuous duty and shall have HP rating necessary to drive th pump at 150% of it's rated discharge at 65% of rated head© Common bed plate of fabricated mild steel channel or cast iron type..(d) Suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc.(e) Pressure switch for automatic operation of motor including necessary wiring upto control panel.(f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CT's protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details.Discharge :450 liter per minuteHead : 35 meter DSR - 27.4.2
281Supply and fixing of ABC type (4 kg.) ISI Marked 1131
282Supply and fixing of CO2 gas type (4.5 kg.) ISI Marked 1132
283Supply and fixing of self glow type exit signage
284Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. Per liters capcity.
2853 Phase Input & 3 Phase Output 10KVA UPS Supply, installation, testing, and commissioning of UPS system with following features - 1. High freq. PWM inverter using IGBT 2. Manual/Auto bypass switch3. SMF batteries to provide approx. 30 min backup time on IT load alongwith battery rack
286Cat6A UTP 4 pair, 23 AWG solid copper cable in existingconduit/ on surface, U/FTP, LSZH, Non-Plenum, Horizontal(solid) Cable suitable for high speed data networkingapplication supporting upto 10Gbps over a 100 meterchannel. 1 Run of Cable
287Supplying, installing, testing and commissioning of 24 port CAT6 jack panel loaded as per the connections required in jack panel.
288Supplying, installing, testing and commissioning of I/O(Information outlet)for CAT6 Cable termination
289Supplying, installing, testing and commissioning of 6 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts.
290Supplying, installing, testing and commissioning of 24 10/100/1000BASE-T PoE-plus
291Supply, Installation, Testing & Commissioning of 4MP IP Network TDN Low-Light IR Rugged Dome Camera, 1/3\\" CMOS, 4 MP @ 25fps or better, triple stream, Min. Illumination required 0.01 lux @ F1.6 (color), 120dB True WDR with Scene Adaptive Control, Min. Pixels 2688 × 1520, Shutter Speed1/3 - 1,00,000; Adavance Video Compression technology such as H.265 &H.264 High Profile , Triple stream, 2.7–13.5 mm 5X motorized focus & zoom lens, BLC, HLC, 3DNR, Minimum Edge Intelligence Video Analytics : Motion Detection, Video Tampering, Face Detection, SD Card Error, SD Card Capacity Warning, Audio Detection, Object Abandoned, Object Missing, Tripwire/Intrusion; Loitering; Privacy Mask, 4 IR LEDs Smart IR with upto50m IR distance, AES-256, SSH/Telnet closed, PCI Data Security Standard compliance; Dual channel Audio G.711a/ G.711Mu/ AAC/G.726, 128GB SD card support, Alarm: 2 In/ 1out, PoE Class 4 (802.3 at) and 12V DC, support aux. power supply of 2W , 12VDC for powering low power devices such as strobe light/hooter, IP 67, IK 10 vandal proof, Die-Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S, G and Q compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55032) , FCC Part 15 & RoHS compliant. Make: Mobotix/ Avgilion/Flir/Axis/Honeywell/Bosch
292Supply, Installation, Testing & Commissioning of 4MP IP Network TDN Low-Light IR Rugged Bullet Camera, 1/3\\" CMOS, 4 MP @ 25fps or better, triple stream, Min. Illumination required 0.01 lux @ F1.6 (color), 120dB True WDR with Scene Adaptive Control, Min. Pixels 2688 × 1520, Shutter Speed1/3 - 1,00,000; Adavance Video Compression technology such as H.265 &H.264 High Profile , Triple stream, 2.7–13.5 mm 5X motorized focus & zoom lens, BLC, HLC, 3DNR, Minimum Edge Intelligence Video Analytics : Motion Detection, Video Tampering, Face Detection, SD Card Error, SD Card Capacity Warning, Audio Detection, Object Abandoned, Object Missing, Tripwire/Intrusion; Privacy Mask, 4 IR LEDs Smart IR with upto 60m IR distance, AES-256, SSH/Telnet closed, PCI Data Security Standardcompliance, Hardware chipset for private key; Dual channel Audio G.711a/ G.711Mu/ AAC/G.726, 128GB SD card support, Alarm: 2 In/ 1out, Long Distance 3X PoE support upto 300m (300m @100Mbps) , PoE Class 4 (802.3 at) and 12V DC,support aux. power supply of 2W ,12VDC for powering low power devices such as strobe light/hooter, IP 67, IK 10 vandal proof, Die-Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S, G and Q compliant, UL, CSA 60950-22, CE (EN50130-4 & EN 55032) , FCC Part 15 & RoHS compliant. Make: Mobotix/ Avgilion/Flir/Axis/Honeywell/Bosch
293SITC of 32 channel Network Video StoragE NVR suitabe to access data from any remote location including backup drive for 30days.
294Supply, Installation, Testing & Commissioning of CCTV Client Operator Station with 1 No.of 55” LED Display - Complete as per specifications & preferred make. Make: SONY/Samsung/LG
295Supply, Installation, Testing & Commissioning of LCD CCTV Joystick Keyboard, LAN POE Connection, 3-Axis Propotional Control, 20 Functional Keys, UL, CE, FCC Listed, Make: Mobotix/ Avgilion/Flir/Axis/Honeywell/Bosch 55'
296Supplying, installing, testing and commissioning of HDMI to HDMI Cable.
297Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
298Supply installing testing & commissioning of out door type junction box, dust tight & vermin proof made out of 14 gauge M.S. sheet, stove powder coated complete as required suitable for mounting of 2 nos. 5/6Amp Switch & Sockets.
299Supplying fixing and commissioning of SILENT (Canopy design) water cooled DG Set with electronic governer with one Diesel Engine with rated capacity (mentioned below) at 0.8 P.F. 1500 RPM, 4 stroke multi-cylinder coupled to brush less type 415 volts 50 cycle/ second self exited alternator completed with cushy pads. Domestic silencer exhaust pipe complete with Alternator auxiliaries, Radiator, 24 volts chargeable battery including initial charging of batteries. suitable for synchronizing complete as per specification. 200 KVA
300Aluminum Frame Green Chalk Board - Sizes 1x1 To 8x5 Available | Modern Rectangular Design For Classroom & EducationDETAILSurface Finish Matte FinishSize StandardColor GreenFeatures Strong quality 5 year warrentyMaterial Aluminum,WoodenShape RectangularFunction Classroom, School & CollegAmount per piece
3011 KVA @ 58480 PER KWP PAR 2025 7.8.1Supply, Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended upto date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required.. a) High Energy Efficiency Solar Photovoltaic Module of capacity330 Wp or above, manufactured in India, conforming to IS14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per degree Celsius. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 Deg C and +85 Deg C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage, range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz,, output voltage suitable to generate AC with a variation of 10% at, nominal voltage. Power with efficiency not less than 97%, total, harmonic distortion less than 3% and suitable for ambient, temperature from 0 to 50 degree C , Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller, Microprocessor /DSP . PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode.It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Shortcircuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232. c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided. d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices. e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminum /cast aluminum alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistantapplied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc. f) Lightning ,surge voltage protection, earthing protection and grid islanding. g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays , supports, lugs, thimble and other accessories etc. as required. h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection inter connection, etc. as required.
302PLUMBING WORKProviding and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size580x440mm with integral type foot rests
303Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked black solid plastic seat and lid
304Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required.White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
305Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required.White Vitreous China Flat Back Wash basin size 550x400 mm with a single 15 mm C.P. brass pillar tap
306Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board of size 510x1040x200mm
307Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia
308Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia
309Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
310Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required: Size 450x300x150 mm
311Providing and fixing white vitreous china flat back half stall urinal of size 430x260x350 mm and 340x410x265mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required:Range of Three half stall urinals with 10 litre P.V.C. automatic flushing cistern
312Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required:Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
313Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required:Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
314Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required:Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern
315Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement:2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade
316Providing and fixing unplasticised PVC connection pipe with brass unions45 cm length 15 mm nominal bore
317Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as approved by Engineer - in - charge.
318Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931a) 15 mm nominal bore
319Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. ( for sink)a) 15 mm nominal bore
320Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931a) 15 mm nominal bore
321Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer- in-charge.
322Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
323Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms.
324Providing & fixing soil, waste and vent pipes. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905a) 100mm dia centrifugally cast iron S & S pipe.
325Providing & fixing soil, waste and vent pipes. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905b) 75mm dia centrifugally cast iron S & S pipe.
326Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. ( for wash basin waste )32mm dia nominal bore
327Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe. a) 100mmSS 304 grade coupling with EPDM rubber gasket
328Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe. b)75mm SS 304 grade coupling with EPDM rubber gasket
329Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate20mm nominal size). Including cost of cutting holes & making good the walls etc.a) for 100mm dia pipe.
330Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate20mm nominal size). Including cost of cutting holes & making good the walls etc.b) for 75mm dia pipe.
331Providing & fixing cast iron coller.a) 100mm dia.
332Providing & fixing cast iron coller.b) 75mm dia.
333Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :a) 100mm inlet & 100mm outlet.
334Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :b) 100mm inlet & 75mm outlet.
335Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.a) 100mm
336Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.b) 75mm
337Providing and fixing plain bend of required degree.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905a) 100mm
338Providing and fixing plain bend of required degree.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905b) 75mm
339Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100x100x100mm
340Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.75x75x75mm
341Providing and fixing centrifugaly cast iron single equal plain junction of required degree.100x100x100mm
342Providing and fixing centrifugaly cast iron single equal plain junction of required degree.75x75x75mm
343Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100x100x75mm
344Providing and fixing single unequal plain invert branch of required degree :100x100x75mm
345Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.)a) 100mm
346Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.)b) 75mm
347Providing and fixing cast iron terminal guard. 100 mm
348Providing and fixing cast iron terminal guard. 75 mm
349Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 100 mm dia
350Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm
351Providing and fixing on wall face unplasticised PVC mouldedfittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler 110 mm
352Providing and fixing on wall face unplasticised PVC mouldedfittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 110 mm Bend 87.5 degree
353Providing and fixing on wall face unplasticised PVC mouldedfittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 110 mm Shoe Shoe (Plain)
354Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
355Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
356Making khurras 45x45 cm with average minimum thickness of5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
357Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.15mm dia nominal outer dia pipes
358Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes
359Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.25mm dia nominal outer dia pipes
360Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work-Exposed on wall 20mm dia nominal bore
361Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in ChargeInternal work-Exposed on wall 25mm dia nominal bore
362Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in ChargeInternal work-Exposed on wall 32mm dia nominal bore
363Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in ChargeInternal work-Exposed on wall 40mm dia nominal bore
364Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in ChargeInternal work-Exposed on wall 50mm dia nominal bore
365Providing and fixing gun metal gate valve with wheel of approved quality. 20mm dia nominal bore
366Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore
367Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore
368Providing and fixing gun metal gate valve with wheel of approved quality. 40mm dia nominal bore
369Providing and fixing gun metal gate valve with wheel of approved quality. 50mm dia nominal bore
370Providing and fixing cp soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
371Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore
372Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
373Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 75 mm O.D.
374Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work.110 mm O.D.
375Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali.
376Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 75 mm
377Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 110 mm
378Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 75/90 mm
379Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 110 mm
380Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. Size 75x75x75 mm
381Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. Size 110x110x110 mm
382Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. Size 75 mm
383Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. Size 110 mm
384Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 1.50 m depthPipes 80 mm to 300 mm diameter
385Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered). Depth not exceeding 1.5 meter
386Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.150 mm. dia. RCC Pipes
387Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.250 mm. dia. RCC Pipes
388Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm. dia.
389Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design250 mm. dia.
390Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cementcomplete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With common burnt clay FPS (non modular) bricks of class designation 75(i) For Sewer Line
391Extra for depth for manholes:Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
392Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).With common burnt clay FPS (non modular) bricks of class designation 75(i) For Sewer Line
393Extra for depth for manholes:Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
394Constructing brick masonary circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and12mm thick cement plaster at the external surface shall be paid for separately):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
395Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
396Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work80 mm nominal dia Pipes
397Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work50 mm nominal dia Pipes
398Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work32 mm nominal dia Pipes
399Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32mm nominal bore.
400Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50mm nominal bore.
401Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80mm nominal bore.
402Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand )12 mm thick finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
403Boring/Drilling borewell of required dia for Casing/strainer pipe, by suitable method prescribed in IS : 2800 (Part-1), including collecting samples from different strata, prepairing and submitting strata chart /bore log, including hire & running charges of all equipments, tools, plants & machineries required for job, all complete as per direction of Engineer-In-Charge, upto 90M depth below the ground level. All types of soil for 350 mm dia
404Boring/Drilling borewell of required dia for Casing/strainer pipe, by suitable method prescribed in IS : 2800 (Part-1), including collecting samples from different strata, prepairing and submitting strata chart /bore log, including hire & running charges of all equipments, tools, plants & machineries required for job, all complete as per direction of Engineer-In-Charge, upto 90M depth below the ground level.Rocky strata including Boulders for 350 mm dia
405Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (RMS) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.150mm nominal size dia
406`Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in-charge.
407Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in- charge.150 mm nominal size dia having minimum wall thickness 5.00 mm.
408Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.150 mm nominal size dia
409Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
410Supplying & Installation of suitable Hp submersible pump B.S or K.S.B or equivalent make with finolex cable 1x3x2.5 squmm(upto 75mtr) withflexible conduit25mm dia, electrical out door pannel with required electrical fitting such as MCB of 0-25Amp (Havell or Indocopp or MDS make), Volt & Ampere meter (AE make), single phase preventer (Minilac or VSP -1 make) starter (L&T or BCH make) etc of approved make, 40mm HDPE Pipe (25 mtr) and all accessories complete as per requirement of site.NOTESa) Contractor shall include the rate of electrical control panels complete with all accessories &controls, all Electrical/Mechanical items as required to operate the system automatic/manual.b) Contractor to select suitable HP of pumps .c) Level Controller with sufficient nos. of low / high level alarms, contacts with electrodes and control wiring for the automatic operation of water supply pumps, Submersible Sump Pumps, to achieve the functional requirement shall be provided. Control wiring between these pumps and water tanks shall be provided.Domestic water pumps must start at low water level in overhead domestic water tank & stop at high level in that water tank. Dry running protection shall be provided for all the pumps.Sequencing shall be provided for each set of pumps.
411Supply of 110mm dia plain PVC.(6kg/sqcm) pressure.
412Supply of 110mm dia sloted PVC (6kg/sqcm) pressure.
413Supply of P.V.C. soket 125mm dia.
414Supply of end cap 110 mm dia.
415Providing necessary boaring T&P including making arrangement of water for boaring 200mm dia bore hole by Rig machine in all type of streta complete item30 metre B.G.L.
416Providing necessary boaring T&P including making arrangement of water for boaring 200mm dia bore hole by Rig machine in all type of streta complete itemBeyond 30 metre.
417Supply & fixing of nylon jalli around the slotted pipe complete as required.
418Lowering of 110mm dia Rogid P.v.c. pipe in bore hole including cutting jointing etc. complete.
419Providing & packing of coarse sand around the P.v.c.pipe.
420Supply of 32mm dia G.i.pipe B class with required fitting. ( SOR Aligarh - 2018 SI No 12 Ch- 23 )
421Supply of India marka - II hand pump ISI marked with cylinder & connecting rods
422Installation of India marka - II hand pump over the bore hole as per direction of E/I
423Development of bore by manual labour till discharge of free from turbity complete item. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57450456
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 19.90 Crore
LAST DATE 06-10-2026
Authority
Authority Name Uttar Pradesh Housing And Development Board
Work Description Tender for Construction Work Of Chief Minister Model Composite School (Phase-2) In District-Mathura
Basic Detail
Tender No 2639/UPHDB/DW-24/215 Dated 02.09.2026
Bidding Type Tender
Location
City Mathura
State Uttar Pradesh
Key Dates
Publish Date 10 Sep 2026
Submission Date 06 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value 19.90 Crore
Tender Fee 8850
EMD 39.80 Lakhs
Exemption Available
Document List
04e1fe28-3212-4703-b845-1522ac8bcd57.html
BOQ_2227892.xls
finbidmathuracomposit.pdf
Techbidmathuracompositcompressed.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

04e1fe28-3212-4703-b845-1522ac8bcd57.html

xls

BOQ_2227892.xls

pdf

finbidmathuracomposit.pdf

pdf

Techbidmathuracompositcompressed.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders