Tender For Supply And Installation Of 12 Mtr. High Mast With 6X200w Led Flood Lights At Kallupalam Center,Ward 01 At Manalur Grama Panchayath In Anthikkad Block Panchayath, Thrissur District.
Tender Value
4.53 Lakhs
Estimated cost
Bid Submission
17 Sep 2026
2 days left
EMD
11331
Bank guarantee accepted
Document Fee
1069
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thrissur → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply And Installation Of 12 Mtr. High Mast With 6X200w Led Flood Lights At Kallupalam Center,Ward 01 At Manalur Grama Panchayath In Anthikkad Block Panchayath, Thrissur District.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | 2.26.1Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil |
| 4 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 6 | 5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 7 | 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size |
| 8 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 9 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m |
| 10 | OD132644/2026-2027Supply and fixing of name board with angles, flats, square pipe, ACP sheet including nut and bolts. 2 nos per mast, 1Sqm in area. |
| 11 | OD132643/2026-2027Fabrication ,Supply ,Conveyance & Installation of Granite name board indicating the cost involved,the commencement,completion and inauguration date etc. |
| 12 | ELECTRICAL WORK |
| 13 | 90.15.2.3Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mmbottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm diadouble drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gearbox and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCCfoundation and junction box etc, complete 12 Meters |
| 14 | 90.15.4.11Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 15 | OD132645/2026-2027Supply and installation of a twin-unit aviation LED obstruction light, featuring a yellow-painted, die-cast aluminum alloy housing, a red polycarbonate dome, andBC/EC lamp holders, suitable for High Mast systems. |
| 16 | 90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wallmounting panel board |
| 17 | 90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising ofthe following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions,folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 18 | 90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 19 | OD132654/2026-2027Supply and installation of a Digital timer, operating at 220-250 VAC, 50Hz, with a 25A/1.5HP capacity. It features 5 On/Off program settings for daily and weeklyschedules, along with manual start, ON delay, and OFF delay settings. Equipped with a high-precision, industrial-grade chip and strong anti-interference capabilities, thetimer can automatically turn on and off the power supply of various electrical equipment according to the time set by the user. The controlled objects can includestreet lights, light boxes, neon lights, and high/mini mast systems. It also includes a sufficient battery backup for time memory in case of power failure, and comes withsuitable fittings for use in a distribution box or MV panel with FRLS PVC insulated .5 mm single core cable suitable for control wiring towards contactor |
| 20 | OD132649/2026-2027Supply and installation of a Three pole 25A Contactor, rated for 220-250 VAC, 50Hz operation with suitable copper socket. It can control street lights, light boxes, neon lights, high/mini mast systems, and induction loads including Motors. |
| 21 | OD132651/2026-2027Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 6 sq. mm (19mm |
| 22 | OD132647/2026-2027Supply and installation of a double pole 25A Contactor, rated for 220-250 VAC, 50Hz operation with suitable copper socket. It can control street lights, light boxes,neon lights, high/mini mast systems, and induction loads. |
| 23 | OD132653/2026-2027Supply and installation of an IP20 Surge Protective Device (SPD) with suitable fittings for a distribution box or MV panel. Specifications include: Voltage ProtectionLevel (Up), Nominal Voltage: 230V, UOC: 10kV, L-N: 7kV, L-PE: 7kV, N-PE: 7kV, Nominal Discharge Current (8/20µs): 10kA, Total Discharge Current(8/20µs): 60kA, Response Time: <35 ns, Ambient Temperature (Ta): -10 to55°C. |
| 24 | OD132652/2026-2027Supply and Installation of Selector switch and Flush head push button for F/R motor control. |
| 25 | OD132646/2026-2027Supply and fixing HRC fuse base of 32 A using suitable nut and bolt, 32 A 2- way neutral links mounted on DMC/SMC base. |
| 26 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 27 | 2.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 28 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 29 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 30 | OD132650/2026-2027Supply and installation of 2.5 Sqmm non-insulated CP-1 pin terminals with suitable size heat shrink |
| 31 | 90.6.5.12Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm |
| 32 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 33 | 5.3Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 34 | 90.16.4.2Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip |
| 35 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 36 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 37 | 90.12.1.13Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm |
| 38 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 39 | OD132648/2026-2027Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 2.5sq. mm |
| 40 | Connection charges - KSEB Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysSep 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender