Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Electrical System Or Installation; Service Provider - Supplying 1.1 Kv Grade, 3.5 Core 70 Sq.Mm Cross-Linked Polyethylene (Xlpe) Insu
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Electrical System Or Installation; Service Provider - Supplying 1.1 Kv Grade, 3.5 Core 70 Sq.Mm Cross-Linked Polyethylene (Xlpe) Insulated, Pvc Inner Sheathed, Galvanized Steel Strip Armoured, Heavy-Duty Overall Pvc Outer Sheathed Aluminium Conductor Power Cable, (To Be Used As Double Run). , Laying And Fixing 3.5 Core 70 Sq.Mm Aluminium Armoured Cable On Wall Surface With Heavy-Duty Gi Saddles/Cl S, Spacers, And Rawl Plugs/Fasteners ( Laying Shall Be Twin Run System For 3000 S Dc Load Power Plant). , Supplying And Making End Termination With Heavy-Duty Double Compression Brass Cable Gland, Tinned Aluminium Crimping Lugs For 3.5 Core 70 Sq.Mm Aluminium Conductor Xlpe Insulated Armoured Power Cable, Glanding, Crimping Of Lugs Using Hydraulic Crimping Tool, Phase-Color Coding Tape Identification, Earthing Connections, Dressing, Testing, And Commissioning Complete As Reqd. , Dismantaling Of Existing Surge Supressor Panel Box , Mcb Db With Mcb ,25Sq Mm Single Core Copper Conductor Power Plant Wiring (3 Circuits) Along With Pvc Pipe & Acessories , Breaking The Cc Masonary As & Where Required Re-Doing The Same Etc As Reqd. , Supplying And Drawing Following 4X120sq Mm Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable With Copper Lugs In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Following 2X16sq Mm Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable With Copper Lugs In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , S/F Of 100 Mm Dia Pvc Conduit Suitable For Drawing 4 Nos 120Sq Mm Cables Along With 2 Nos 16 Sqq Mm Cables With All Acessories Etc As Reqd. , Sitc Of 315 S 4Pole Ac 3Ph On Load Sdf Switch With All Acessories But With Out Enclosure I/C Fixing & Testing Etc As Reqd. , S/F Of Suitable Size & Design 16G Crca Sheet Cable Adapter Box I/C Al Bus Bars, Insulators, Isolation Barriers Etc As Reqd.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supplying 1.1 kV grade, 3.5 Core 70 sq.mm cross-linked polyethylene (XLPE) insulated, PVC inner sheathed, galvanized steel strip armoured, heavy-duty overall PVC outer sheathed aluminium conductor power cable, (to be used as double run).\\" | Supplying 1.1 kV grade, 3.5 Core 70 sq.mm cross-linked polyethylene (XLPE) insulated, PVC inner sheathed, galvanized steel strip armoured, heavy-duty overall PVC outer sheathed aluminium conductor power cable, (to be used as double run).\\" |
| 2 | Laying and fixing 3.5 Core 70 sq.mm Aluminium Armoured Cable on wall surface with heavy-duty GI saddles/clamps, spacers, and rawl plugs/fasteners ( Laying shall be twin run system for 3000Amps DC load Power plant). | Laying and fixing 3.5 Core 70 sq.mm Aluminium Armoured Cable on wall surface with heavy-duty GI saddles/clamps, spacers, and rawl plugs/fasteners ( Laying shall be twin run system for 3000Amps DC load Power plant). |
| 3 | Supplying and making end termination with heavy-duty double compression brass cable gland, tinned aluminium crimping lugs for 3.5 Core 70 sq.mm aluminium conductor XLPE insulated armoured power cable, glanding, crimping of lugs using hydraulic crimping tool, phase-color coding tape identification, earthing connections, dressing, testing, and commissioning complete as reqd. | Supplying and making end termination with heavy-duty double compression brass cable gland, tinned aluminium crimping lugs for 3.5 Core 70 sq.mm aluminium conductor XLPE insulated armoured power cable, glanding, crimping of lugs using hydraulic crimping tool, phase-color coding tape identification, earthing connections, dressing, testing, and commissioning complete as reqd. |
| 4 | Dismantaling of existing Surge supressor panel box , MCB DB with MCB ,25Sq MM single core copper conductor power plant wiring (3 circuits) along with PVC pipe & acessories , breaking the CC masonary as & where required re-doing the same etc as reqd. | Dismantaling of existing Surge supressor panel box , MCB DB with MCB ,25Sq MM single core copper conductor power plant wiring (3 circuits) along with PVC pipe & acessories , breaking the CC masonary as & where required re-doing the same etc as reqd. |
| 5 | Supplying and drawing following 4X120Sq mm of FRLS/HFFR PVC insulated copper conductor, single core cable with copper lugs in the existing surface/ recessed steel/ PVC conduit as required. | Supplying and drawing following 4X120Sq mm of FRLS/HFFR PVC insulated copper conductor, single core cable with copper lugs in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | Supplying and drawing following 2X16Sq mm of FRLS/HFFR PVC insulated copper conductor, single core cable with copper lugs in the existing surface/ recessed steel/ PVC conduit as required. | Supplying and drawing following 2X16Sq mm of FRLS/HFFR PVC insulated copper conductor, single core cable with copper lugs in the existing surface/ recessed steel/ PVC conduit as required. |
| 7 | S/f of 100 mm dia PVC conduit suitable for drawing 4 nos 120sq mm cables along with 2 nos 16 sqq mm cables with all acessories etc as reqd. | S/f of 100 mm dia PVC conduit suitable for drawing 4 nos 120sq mm cables along with 2 nos 16 sqq mm cables with all acessories etc as reqd. |
| 8 | SITC of 315Amps 4Pole AC 3Ph on load SDF switch with all acessories but with out enclosure i/c fixing & testing etc as reqd. | SITC of 315Amps 4Pole AC 3Ph on load SDF switch with all acessories but with out enclosure i/c fixing & testing etc as reqd. |
| 9 | S/f of suitable size & design 16G CRCA sheet cable adapter box i/c Al bus bars, insulators, isolation barriers etc as reqd. | S/f of suitable size & design 16G CRCA sheet cable adapter box i/c Al bus bars, insulators, isolation barriers etc as reqd. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender