Drinking Water Supply and Sanitation Government Departments Closing in 2 days TDR #57447769

Tender For Construction And Commissioning Of Tube Wells By Dth/Rotary/ Comb. Rig Of 200 Mm Dia, Under Rwss Jurisdiction Div. Nagaur With 24 Months Defect Liability Period (Arc)

Issued by Government Departments · Nagaur, Rajasthan
Tender Value
1.60 Crore
Estimated cost
Bid Submission
17 Sep 2026
2 days left
EMD
3.20 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nagaur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction And Commissioning Of Tube Wells By Dth/Rotary/ Comb. Rig Of 200 Mm Dia, Under Rwss Jurisdiction Div. Nagaur With 24 Months Defect Liability Period (Arc)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Sep-2026 Corrigendum for Technical bid Technical Bid 17-Sep-2026

BOQ

Name of Work:- Construction and Commissioning of Tube Wells by DTH/Rotary/ Comb. rig of 200 mm dia, under RWSS Jurisdiction Div. Nagaur with 24 months defect liability period (ARC)
Sl. No. Item Description
1Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gra vel & it's primary packing and packing during development,lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water.Rates are exclusive of GST
2Nominal bore 200 mm dia.
3Add 15% extra on above item (BSR Item no 2.1.1 to 2.1.3) for drilling depth beyond 100 mtr and upto 200 mtr, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
4Add 40% extra on above item (BSR Item no 2.1.1 to 2.1.3) for drilling depth beyond 200 mtr, rate shall be applicable for only extra depth beyond 200 mtr .
5Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. Rates are exclusive of GST
6Nominal bore 200 mm dia.
7Add 15% extra on above item (BSR Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
8Add 30% extra on above item (BSR Item No 2.4.1 to 2.4.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .
9Add 15% extra on above item (BSR Item No 2.4.1 to 2.4.4) for drilling, where strata is collapsible and lowering of casing pipe is required . The work includes lowering of casing pipe, but excluding the cost of casing pipe. The rate shall be applicable for stretch of collapsible strata only.
10Construction of Tube Well from ground level and upto 100 mtr. depth to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications for removal of overburden. The work includes the cost of lowering of casing pipe, but excludes the cost of casing pipe. Rates are exclusive of GST
11Nominal bore 200 mm dia
12Add 15% extra on above item (BSR Item No 2.2.1 to 2.2.2) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr
13Construction of tube well from ground level and up to 100 mtr depth and above to accommodate housing assembly pipe in all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work will include lowering of housing and strainer pipe assembly and casing shoe including cost of casing shoe, but excluding cost of the casing pipe. The work would be completed after obtaining sand free water. Rates are exclusive of GST
14Nominal bore 200 mm dia.
15Add 15% extra on above item (BSR Item No 2.3.1 to 2.3.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
16Add 30% extra on above item (BSR Item No 2.3.1 to 2.3.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .
17\\"Add 15% extra on above item (BSR Item No 2.3.1 to 2.3.4) for drilling, where strata is collapsible and lowering of casing pipe is required . The work includes lowering of casing pipe, but excluding the cost of casing pipe. The rate shall be applicable for stretch of collapsible strata only.
18Deepening of existing tube well by DTH system beyond existing depth up to 100 mtr. and above in all type of rocks including flushing of tube well and obtaining sand free water. Rates are exclusive of GST
19Supply & fixing tube well cover of MS sheet 8 mm thick at top & 5 mm thick 100 mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45 cm log & two GI flanges at both end in 80 mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation presuure gauge) shall be provided & welded with 80 mm GI nipple near top plate nipple shall be provided with end plug.Rates are exclusive of GST
20200 mm dia
21Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS: 8110-2000 or as amended up to date Rates are exclusive of GST
22200 mm dia nominal bore of 5.4 mm thickness
23Supply of ERW M.S. black casing pipe ISI marked (IS : 4270/2001) or amended upto date of grade Fe 410 of following sizes Rates are exclusive of GST
24200 mm dia nominal bore of 5.4 mm thickness and mass of tube 28.46 Kg/m)
25Providing & Lowering in tubewell ISI marked GI Pipe \\"B\\" class as per IS : 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25 x 3 mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. Rates are exclusive of GST
2650 mm dia
2765 mm dia
2880 mm dia
29Supply & fixing of ISI marked three core PVC flat submersible cable as per IS : 694:1990 ro amended upto date and conductor as per class 5 of IS 8130:1980 including making connection etc.Rates are exclusive of GST
303 core 4.0 mm2
313 core 6.0 mm2
323 core 10.0 mm2
333 core 16.0 mm2
34Supply, installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS : 8034-2011 (pump) and IS 9283-2013 (motor) or amended upto date of approved make of following duty condition with required accessories includig making connection suitable for tube well/ DCB. The job includes lowering of motor pumps, installation of complete fitting & accessories, jointing of electrical cables upto switch board, testing of submersible pump sets and interconnection up to water mains, complete in all respect. Rates are exclusive of GST
35Up to 5.5 KW (7.5 HP) & head up to 120 mtr
36Up to 5.5 KW (7.5 HP) & head above 120 mtr
377.5 KW (10 HP) & head up to 120 mtr
387.5 KW (10 HP) & head above 120 mtr
399.3 KW (12.5 HP) & head up to 120 mtr
409.3 KW (12.5 HP) & head above 120 mtr
4111 KW (15 HP) & head up to 120 mtr
4211 KW (15 HP) & head above 120 mtr
4313 KW (17.5 HP) & head up to 120 mtr
4413 KW (17.5 HP) & head above 120 mtr
4515 KW (20 HP) & above, head up to 120 mtr
4615 KW (20 HP) & above, head above 120 mtr
47S&F MS clamps set of 50 mm x 6 mm flat form iron with nuts and bolts etc for holding the riser pipe assembly of submersible pumpset Rates are exclusive of GST
48Supply and fixing of electric control feeder panel comprising of suitable rating MCCB, DOL, starter, overload rely, ampere meter, volt meter phase, preventer, phase indicator, lighting arrangment etc. complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage MS sheet with power coating. Panel should be of minimum size 900 x 600 x 300mm with stand (made of angle iron of size 35x35x5 mm) duly bolted/ serewed with enclosure box having 4 elgs, each leg's length 18\\" and double door incuding in built locking system. The legs should be embedded in M-15 cement cocrete platform. The size of CC platform should be equal or bigger than the base size of panel having high of atlest 200 mm from ground level. The panel shoud have opening of suitable size infront of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC supply. Rates are exclusive of GST
49Up to 5.00 HP
50Supply and fixing of electric control feeder panel comprising of suitable rating MCCB, fully automatic star-delta starter, over load relya, ampere n meter with CTs, volt meter, phase preventor, suitable starting copacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these equipments shall be housed by panel box made out form 18 guage MS sheet with powder coating. panel should be of minimum size 900 X 600 x 450 mm with stand (made of angle iron of size 35x35x5m) duly bolted/ screwed with enclosure box having 4 legs, each leg's length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC plate form should be equal or bigger thatn the base size of panel having height of at least 200 mm from gound level. The panel should have opening of suitable size in fron of space for energy meter with glass for meter reading. the operation of panel should be suitable for on 440 volt AC supply Rates are exclusive of GST
51Above 5 HP and up to 10 HP
52Above 10 HP and up to 15 HP
53Above 15 HP and up to 20 HP
54Above 20 HP and up to 30 HP
55Providing and fixing of double flanged, CI body, ISI marked NRV of approved make of size 65 mm dia Rates are exclusive of GST
56Providing and fixing of double flanged, CI body, ISI marked NRV of approved make of size 80 mm dia Rates are exclusive of GST
57Providing, installing, festing and comm. Of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia Rates are exclusive of GST
5850 mm dia
5965 mm dia
60Supplying & Installing 100mm dia mtr. Sealed diaphragm bourden type pressure gauge along with all jointing materials Range 0 to 10 kg of makes specified in specifications with sefety cover Rates are exclusive of GST
61Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required Rates are exclusive of GST
62Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. Rates are exclusive of GST
6310.0 Sq.mm, 4 core
6416.0 Sq.mm, 4 core
6525.0 Sq.mm, 3.5 core
6635.0 Sq.mm, 3.5 core
67Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated CI Sluice valve of Class PN-1.0 Rates are exclusive of GST
6880 mm
69100 mm
70125mm
71150 mm
72SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 32Amp. AC-3 duty PMC based DC contactors (For Star and Main), 40Amp. 1 Pole Contactor for APSC, 22Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. Rates exclusive GST
73Above 5 HP and up to 10 HP (Star Delta type)
74SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 35Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 25Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.
75Above 10 HP and up to 15 HP (Star Delta type)
76SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 35Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 25Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.
77Above 15 HP and up to 20 HP (Star Delta type)
78SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 35Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 25Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.
79Above 20 HP and up to 25 HP (Star Delta type)
80SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 35Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 25Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.
81Above 25 HP and up to 30 HP (Star Delta type)
82Maintiance of TWs which includes round the the clock monitoring of TWs of all sizes, complete including cost of material components required to repair pump sets, staters meters etc. of electrict panel of TWs, lowering and unlowreing of pump sets complete in all respect maintiance of log book and histrory sheets as directed by Engiener - in- charge for TW per month. (excluding repairing of Pump sets)
83O&M for first 2 year (only 70% of total Annual O&M during each year)
84O&M for Third, Fourth & Fifth Year Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57447769
AUTHORITY Government Departments
TENDER VALUE 1.60 Crore
LAST DATE 17-09-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Construction And Commissioning Of Tube Wells By Dth/Rotary/ Comb. Rig Of 200 Mm Dia, Under Rwss Jurisdiction Div. Nagaur With 24 Months Defect Liability Period (Arc)
Basic Detail
Tender No Nit No 12/2026-27 SE
Bidding Type Tender
Location
City Nagaur
State Rajasthan
Key Dates
Publish Date 15 Sep 2026
Submission Date 17 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value 1.60 Crore
Tender Fee 5000
EMD 3.20 Lakhs
Exemption Available
Document List
BOQ_1058164.xls
c3dab99b-d8f5-4a18-b883-de237383bb4a.html
Tech12.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 15, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Sep 17, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Sep 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1058164.xls

html

c3dab99b-d8f5-4a18-b883-de237383bb4a.html

pdf

Tech12.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders