Tender For Repair To Solar Water Heater, Electrical Geysers, Dosing Plant At Water Supply Installations And Sewage Pressure Pipeline In Aor Of Age E/M Of Ge (West) Ferozepur Cantt
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Oct 2026
26 days left
EMD
1.15 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Firozepur → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Solar Water Heater, Electrical Geysers, Dosing Plant At Water Supply Installations And Sewage Pressure Pipeline In Aor Of Age E/M Of Ge (West) Ferozepur Cantt
BOQ
| Sl. No. | Item Description |
| 1 | S&F in repair and replacement chemical inject dosing pumpset of electromagnetic and diaphragm type of capacityacity 10 litres per hour with back pressure 10 Kg per Sqcm, including dismantling complete all as specified and directed. |
| 2 | S&F in repair and replacement chemical inject dosing pumpset of electromagnetic and diaphragm type of capacityacity 5 litres per hour with back pressure 4 Kg per Sqcm, including dismantling complete all as specified and directed. |
| 3 | S&F in repair and replacement Chlorine Agitator Motor 120 Watt, 220 V, 900 RPM, single phase, flange mounted motor with plastic shaft and impeller for making chlorine liquid solution, including dismantling complete all as specified and directed. |
| 4 | S&F in repair and replacement Chlorine Injector Valve for chlorine dosing pump to protect against back flow and generate a defined back pressure to inject the chlorine in delivery head of submersible pumpset, including dismantling complete all as specified and directed. |
| 5 | S&F in repair and replacement Foot valve suction strainer for chlorine dosing pumpset, including dismantling complete all as specified and directed. |
| 6 | S&F in repair and replacement Suction/Discharge tubing (3/6\\" - white) to inject chlorine in the suction of submersible pumpset,including dismantling complete all as specified and directed. |
| 7 | S&F in repair and replacement Impeller with plastic shaft to make liquid solution, including dismantling complete all as specified and directed. |
| 8 | S&F in repair and replacement Spring for EPU suitable for chlorine dosing pump set, including dismantling complete all as specified and directed. |
| 9 | S&F in repair and replacement Coil suitable for chlorine dosing pump set, including dismantling complete all as specified and directed. |
| 10 | S&F in repair and replacement Speed knob suitable for chlorine dosing pump set, including dismantling complete all as specified and directed. |
| 11 | S&F in repair and replacement Diaphragm suitable for chlorine dosing pump set, including dismantling complete all as specified and directed. |
| 12 | S&F in repair and replacementring Seal Teflon suitable for chlorine dosing pump set, including dismantling complete all as specified and directed. |
| 13 | S&F in repair and replacement Ball ceramic suitable for chlorine dosing pump set, including dismantling complete all as specified and directed. |
| 14 | S&F in repair and replacement Fuse suitable for chlorine dosing pump set, including dismantling complete all as specified and directed. |
| 15 | S&F in repair and replacement Speed shaft suitable for chlorine dosing pump set complete all as specified and directed. |
| 16 | S&F in repair and replacement Shim EPU suitable for chlorine dosing pump set, including dismantling complete all as specified and directed. |
| 17 | S&F in repair and replacement 25 litres capacityacity Copper Tank with wall thgickness 0.8mm suitable geyser including taking down existing geyser storage type capacityacity 25 litres including disconnecting electrical and water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling and refixing in position complete all as specified. |
| 18 | S&F in repair and replacement 50 litres capacityacity Copper Tank with wall thgickness 0.8mm suitable geyser including taking down existing geyser storage type capacityacity 50 litres including disconnecting electrical and water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling and refixing in position complete all as specified. |
| 19 | S&F in repair and replacement 25 litres capacityacity Stainless steel (SS 304)Tank with wall thgickness 2.0mm suitable geyser including taking down existing geyser storage type capacityacity 25 litres including disconnecting electrical and water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling and refixing in position complete all as specified. |
| 20 | S&F in repair and replacement 50 litres capacityacity Stainless steel (SS 304)Tank with wall thgickness 2.0mm suitable geyser including taking down existing geyser storage type capacityacity 50 litres including disconnecting electrical and water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling and refixing in position complete all as specified. |
| 21 | S&F in repair and replacement Inner assembly copper with brass pressure screw for 25 litres capacityacitygeyser as per sample produced including taking down existing geyser storage type capacityacity 25 litres, disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling and refixing in position as specified and directed. |
| 22 | S&F in repair and replacement Inner assembly copper with brass pressure screw for 50 litres capacityacitygeyser as per sample produced including taking down existing geyser storage type capacityacity 50 litres, disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling and refixing in position as specified and directed. |
| 23 | S&F in repair and replacement Inner assembly steel with steel pressure screw for 25 litres capacityacity complete all as per sample produced including taking down of geyser storage type capacity 25 ltr, disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & refixing in position all as specified and directed. |
| 24 | S&F in repair and replacement Inner assembly steel with steel pressure screw for 50 litres capacityacity complete all as per sample produced including taking down of geyser storage type capacity 50 litres, disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & refixing in position all as specified and directed. |
| 25 | S&F in repair and replacement Outer body made out of 18 gauge of mild steel sheet for geyser capacityacity 25 litres, size and shape as per sample produced, duly painted with white enameled paint including taking down of geyser storage type capacity 25 litres, disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & refixing in position complete all as specified and directed. |
| 26 | S&F in repair and replacement Outer body made out of 18 gauge of mild steel sheet for geyser capacityacity 50 litres, size and shape as per sample produced, duly painted with white enameled paint including taking down of geyser storage type capacity 50 litres, disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & refixing in position complete all as specified and directed. |
| 27 | S&F in repair and replacement Heating element 1500 Watt capacityacity for geysers (in triangle/round shape) including taking down of geyser storage type capacityacity 25/50 litres, disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & refixing in position complete all as specified. Make: Theeta/Bajaj/Racold/Pioneer or Equivalent. |
| 28 | S&F in repair and replacement Heating element 2000 Watt capacityacity for geysers (in triangle/round shape) including taking down of geyser storage type capacity 25/50 litres, disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & refixing in position complete all as specified. Make: Theeta/Bajaj/Racold/Pioneer or Equivalent. |
| 29 | S&F in repair and replacement Thermostat range 20 to 80 degree centigrade ISI marked for 25/50 litres capacityacity geysers including taking down of geyser storage type capacityacity 25/50 ltr, disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & refixing in position complete all as specified. |
| 30 | S&F in repair and replacement LED indicator lamp red & green as per existing shape and size, 230V etc all as specified. |
| 31 | S&F in repair and replacement PVC 3 core copper conductor flexible cable of size 70/0.0076 for geyser connection etc all as specified. |
| 32 | S&F in repair and replacement PVC 3 core copper conductor flexible cable of size 40/0.0076 for geyser connection etc all as specified. |
| 33 | S&F in repair and replacement 15mm bore Pressure Release valve for 25 litres capacityacity geyser etc complete all as specified. |
| 34 | S&F in repair and replacement Non Return Valve of size 15mm for 25/50 litres capacityacity geyser etc. |
| 35 | S&F in repair and replacement Inlet pressure reducer valve of size 15mm suitable to fix in inlet of geyser of any size and shape complete all as specified. |
| 36 | S&F in repair and replacement Bottom cover (Half round plate) duly powder coated and matching colour of existing geyser of any make for 25 litres capacityacity incl screws and connection of indicator etc including taking down of geyser storage type capacityacity 25 litres, disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & refixing in position complete all as specified. |
| 37 | S&F in repair and replacement Bottom cover (Half round plate) duly powder coated and matching colour of existing geyser of any make for 50 litres capacityacity incl screws and connection of indicator etc including taking down of geyser storage type capacityacity 50 litres, disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & refixing in position complete all as specified. |
| 38 | S&F in repair and replacement Dead nut of suitable size (as per sample produce) for fixing on 25/50 litres capacity geysers of any make and size all as per specified and directed. |
| 39 | S&F in repair and replacement 15mm PVC connections 450mm long heavy duty, with chromium plated brass nuts adaptors and washers and rubber gaskets at both ends, fibre or thread woven and impregnated in flexible PVC tube/hose suitable for hot and cold water supply of geysers complete all as specified and directed. |
| 40 | S&F in repair and replacement 15mm PVC connections 600mm long heavy duty, with chromium plated brass nuts adaptors and washers and rubber gaskets at both ends, fibre or thread woven and impregnated in flexible PVC tube/hose suitable for hot and cold water supply of geysers complete all as specified and directed. |
| 41 | S&F in repair and replacement PVC Washer suitable for fixing in reinforced PVC Connection pipe of size 15mm all as specified and directed. |
| 42 | S&F in repair and replacement 15mm PVC connections 450mm long heavy duty, with steel nuts adaptors and washers and rubber gaskets at both ends, fibre or thread woven and impregnated in flexible PVC tube/hose suitable for hot and cold water supply of geysers complete all as specified and directed. |
| 43 | S&F in repair and replacement 15mm PVC connections 600mm long heavy duty, with steel nuts adaptors and washers and rubber gaskets at both ends, fibre or thread woven and impregnated in flexible PVC tube/hose suitable for hot and cold water supply of geysers complete all as specified and directed. |
| 44 | S&F in repair 15mm bore Angle/Angular stop Valves, fancy type, chromium plated, cast copper alloy, with flange, one way turn, screwed down high pressure, with crutch or butterfly handle, screwed for iron pipe complete all as specified and directed. |
| 45 | S&F in repair and replacement Spacer ring for 25/50 litres capacityacity made out of 1.6 mm thick MS sheet etc complete all as specified and directed. |
| 46 | S&F in repair and replacement Chromium plated hexagonal nipple of 15mm dia of required length as per site requirement for connecting the PVC connection to the geyser complete all as specified and directed. |
| 47 | S&F in repair and replacement Glass wool for geyser for inner side of outer & inner tank for insulation including taking down of geyser storage type capacity 25/50 ltr, disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & refixing in position complete all as specified and directed. |
| 48 | M&L for spray painting of geyser of any capacityacity 25 litres with white duco paint, including taking down of geyser storage type capacity 25 ltr and re-assembling & refixing in position complete all as specified and directed. |
| 49 | M&L for spray painting of geyser of any capacityacity 50 litres with white duco paint, including taking down of geyser storage type capacity 50 litres and re-assembling & refixing in position complete all as specified and directed. |
| 50 | M&L for shifting/fixing of geyser of 25 litres capacityacity in brick wall by taking down it from its existing location to new location by grouting of 04 Nos holding fastener nut bolts in PCC (1:2:4) or cement mortar (1:3) making good the distrubed surfaces to match with existing surfaces complete all as specified and directed. |
| 51 | M&L for shifting/fixing of geyser of 50 litres capacityacity in brick wall by taking down it from its existing location to new location by grouting of 04 Nos holding fastener nut bolts in PCC (1:2:4) or cement mortar (1:3) making good the distrubed surfaces to match with existing surfaces complete all as specified and directed. |
| 52 | S&F in repair and replacement Metal Clad 2 Pin plus earth arrangement (2P+E) top plug of 20 Amp capacityacity 230 volts only for replacement of burnt/unserviceable metal clad top plug for geysers complete all as specified and directed. |
| 53 | S&F in repair and replacement metal clad 2 Pin plus earth arrangement (2P+E) socket of 20 Amp capacityacity 230 volts only for replacement of burnt/unserviceable metal clad socket for geysers complete all as specified and directed. |
| 54 | S&F in repair and replacement Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 20 to 32 Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 55 | S&F in repair and replacement 15/16 Amp Socket outlet 2 in 1, 3 pin flush type ISI marked complete all as specified and directed. |
| 56 | S&F in repair and replacement 3 pin Bakelite Top of 15/16 Amp capacity, 240 V only for replacement of burnt/unserviceable top for geyser complete all as specified and directed. |
| 57 | S&F in repair and replacement 15/16 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed. |
| 58 | S&F in repairs Single Pole two Pin and Earth Plug and Socket including one single pole MCB 20 Amp fixed in and including sheet Metal enclosures, including taking down, complete all as specified and directed. |
| 59 | Taking down for gas welding of minor leakage geyser storage type capacity 25/50 litres any make or type incl disconnecting electrical and water supply connection, dismantling, stripping up for inspection and repair it by gas welding, cleaning, reassembling and refixing in position including dismantling and taking down complete all as specified and directed. Replacement of unserviceable parts shall be measured and paid separately. |
| 60 | S&F in repair and replacement Fuse plug for geyser as per sample all as directed. |
| 61 | M&L for Disconnecting, dismantling of solar water heating system incl all water and electric connection of capacityacity 500 litres per day and refixing the same in existing position after repairs and testing complete. Includes replacement of worn out/missing nuts, bolts, washers, unions, sockets, flanges and screw etc; descaling/desludging hot water pipes and normal water by appropriate chemicals; cleaning/washing copper tube & water circulated pipes; cleaning hot/cold water tanks; repair of collectors incl welding; testing after repair and making Solar Water Heater functional. Spare parts such as solar energy collector panel, toughened glass, rubber gasket, hose pipe, insulation for hot water pipe, heating element, thermostat, water storage tank, gate valve/float valve, MS clamp shall be measured & paid separately. |
| 62 | All as per item No. 1 herein before but of capacityacity 300 litres per day complete all as directed by Engineer-in-Charge. |
| 63 | All as per item No. 1 herein before but of capacityacity 100 litres per day complete all as directed by Engineer-in-Charge. |
| 64 | Supply and installation in replacement of complete one solar energy collector panel (FPC) made of aluminium body with toughened glass complete with copper fins incl all accessories capacityable to heat 100 Litre water per day suitable to be fitted for 500 LPD, 300 LPD & 100 LPD Solar water heating system complete complete all as specified and directed. Make: Tata BP Solar/Sun Stellar/Inter Solar/RES or Equivalent. |
| 65 | S&F in repair and replacement Solar panel toughened glass (1m×2m) or equivalent size as of existing having thickness 4 mm all as existing model of Solar panel system complete complete all as specified and directed. |
| 66 | S&F in repair and replacement Rubber gaskets made out of fine rubber for Solar panel complete to make system air tight dust and water leak proof complete complete all as specified and directed. |
| 67 | S&F in repair and replacement Hose pipe 1\\" (25 mm) inner dia for hot/cold water for solar system of suitable length as existing size complete with 02 Nos clamps for required size complete complete all as specified and directed. |
| 68 | M&L for Legging to pipes used for Hot water supply or plumbing all around with 25mm min thick bonded material wool preformed, snap on pipe section of density of 144 Kg/cum conforming to IS 9842 for 15 mm dia pipe complete complete all as specified and directed. |
| 69 | S&F in repair and replacement Evacuated Tubes Box of 58×1800 MM or equivalent size as of existing. |
| 70 | S&F in repair and replacement Evacuated Tubes Box of 58×2100 MM or equivalent size as of existing complete complete all as specified and directed. |
| 71 | M&L for Lean Cement Concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 72 | M&L for staging of solar system, cross arms, bracings, supports, clamps, and back plates base of existing PVC cold water Tank fabricated from mild steel sections & placing of collector panels on solar panel frame/supporting hot water pipes on hot water tank including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed add inclusive of one primer coat of red oxide, finishing coat of synthetic enamel paint complete complete all as specified and directed. |
| 73 | M&L for submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 4.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 4.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 4.0Sqmm and one run of 4.0Sqmm PVC insulated copper conductor single core (2x4.0Sqmm+1x4.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run) |
| 74 | S&F in repair and replacement Heating element for solar water heater of wattage 3.0 KW operating on 240 V AC complete complete all as specified and directed. |
| 75 | S&F in repair and replacement Heating element for solar water heater of wattage 2.0 KW operating on 240 V AC complete complete all as specified and directed. |
| 76 | S&F in repair and replacement Thermostat for solar water heater of wattage 3.0 KW operating on 240 V AC complete complete all as specified and directed. |
| 77 | S&F in repair and replacement thermostat for solar water heater of wattage 2.0 KW operating on 240 V AC complete complete all as specified and directed. |
| 78 | S&F in repair and replacement 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. hoisted and fixed complete as specified in SSR Part-I. complete all as specified and directed. |
| 79 | S&F in repars 20mm bore Ball valves high pressure of PTMT withepoxy coated Aluminium rod & high density plastic float ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210gms./25mm-455gms/ 40mm - 690 gms) complete all as specified and directed. |
| 80 | S&F in repairs 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and directed. |
| 81 | S&F in repairs Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 40Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 82 | S&F in repair and replacement Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 40 to 63 Amp, 240V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 83 | S&F in repair and replacement sheet metal enclouser single door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 Volts 200 Amps rated bus bar,Neutral link,Earth bar and Din rail, 2 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 84 | S&F in repair and replacement Mild steel clamp of existing size of hose pipe complete complete all as specified and directed. |
| 85 | S&F in repair and replacement panel flange Rubber gasket Fine Rubber complete complete all as specified and directed. |
| 86 | S&F in repair and replacement 15mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, laid in trenches complete all as specified and directed. |
| 87 | S&F 20mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, laid in trenches complete all as specified and directed. |
| 88 | M&L for Painting of Solar Staging System, solar panel Frame, hot water tank frame (one coat) one finishing coat of synthetic enamel paint complete complete all as specified and directed. |
| 89 | Excavating in trenches, in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables and pipes etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out complete all as specified and as direcetd. |
| 90 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceding 25cm in soft/loose soil complete all as directed. |
| 91 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 92 | Taking up or down or out existing 15-75mm bore HDPE/PVC/ Cement water mains (including all fittings) from over head tanks/reservoirs, walls, trenches etc and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 93 | Taking up or down or out existing 100-250mm bore HDPE/PVC/ Cement water mains (including all fittings) from over head tanks/reservoirs, walls, trenches etc and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 94 | Taking up or down or out existing 100mm bore CI/DI/GI/MS/AC/HDPE/PVC water mains, sewage pipes (including all fittings) from over head tanks/reservoirs, walls, trenches etc and removing from site and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 95 | Taking up or down or out existing 150mm bore CI/DI/GI/MS/AC/HDPE/PVC water mains, sewage pipes (including all fittings) from over head tanks/reservoirs, walls, trenches etc and removing from site and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 96 | Taking up or down or out existing 200mm bore CI/DI/GI/MS/AC/HDPE/PVC water mains, sewage pipes (including all fittings) from over head tanks/reservoirs, walls, trenches etc and removing from site and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 97 | Taking up or down or out existing 250mm bore CI/DI/GI/MS/AC/HDPE/PVC water mains, sewage pipes (including all fittings) from over head tanks/reservoirs, walls, trenches etc and removing from site and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 98 | Taking up or down or out existing 50mm bore galvanised steel water tubing, alongwith connections complete and removing from site all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 99 | Supply, lay, joint , fix and commission after test 100mm bore Centrifugally cast (spun) ductile iron with spigot & socket end, class K-7 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000). Pursuant to clause 15.5.1 of IS8329, 10% of pipes in each size, may be supplied in shorter lengths, complete all as specified. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 100 | Supply, lay, joint , fix and commission after test 150mm bore Centrifugally cast (spun) ductile iron with spigot & socket end, class K-7 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000). Pursuant to clause 15.5.1 of IS8329, 10% of pipes in each size, may be supplied in shorter lengths, complete all as specified. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 101 | Supply, lay, joint , fix and commission after test 200mm bore Centrifugally cast (spun) ductile iron with spigot & socket end, class K-7 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000). Pursuant to clause 15.5.1 of IS8329, 10% of pipes in each size, may be supplied in shorter lengths, complete all as specified. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 102 | Supply, lay, joint , fix and commission after test 250 mm bore Centrifugally cast (spun) ductile iron with spigot & socket end, class K-9 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000). Pursuant to clause 15.5.1 of IS8329, 10% of pipes in each size, may be supplied in shorter lengths, complete all as specified. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 103 | Supply, lay, joint , fix and commission after test, 25mm bore HDPE (High Density Polyethylene) pressure pipe, PN-6, condorming to IS 4984-2016, amended upto date, ISI marked with and including fittings,jointing and fixing at site with HDPE Jointing/welding Machine by heatring and giving pressure, as per pipe, laid in trenches, fixed to walls, columns of over head reservoirs, concrete surfaces, under floors etc complete all as specified and directed. |
| 104 | Supply, lay, joint , fix and commission after test, 50mm bore HDPE (High Density Polyethylene) pressure pipe, PN-10, conforming to IS 4984-2016, amended upto date, ISI marked with and including fittings,jointing and fixing at site with HDPE Jointing/welding Machine by heatring and giving pressure, as per pipe, laid in trenches, fixed to walls, columns of over head reservoirs, concrete surfaces, under floors etc complete all as specified and directed. |
| 105 | Supply, lay, joint , fix and commission after test, 75mm bore HDPE (High Density Polyethylene) pressure pipe, PN-10, conforming to IS 4984-2016, amended upto date, ISI marked with and including fittings,jointing and fixing at site with HDPE Jointing/welding Machine by heatring and giving pressure, as per pipe, laid in trenches, fixed to walls, columns of over head reservoirs, concrete surfaces, under floors etc complete all as specified and directed. |
| 106 | Supply, lay, joint , fix and commission after test, 100mm bore HDPE (High Density Polyethylene) pressure pipe, PN-10, condorming to IS 4984-2016, amended upto date, ISI marked with and including fittings,jointing and fixing at site with HDPE Jointing/welding Machine by heatring and giving pressure, as per pipe, laid in trenches, fixed to walls, columns of over head reservoirs, concrete surfaces, under floors etc complete all as specified and directed. |
| 107 | Supply, lay, joint , fix and commission after test, 150mm bore HDPE (High Density Polyethylene) pressure pipe, PN-10, conforming to IS 4984-2016, amended upto date, ISI marked with and including fittings,jointing and fixing at site with HDPE Jointing/welding Machine by heatring and giving pressure, as per pipe, laid in trenches, fixed to walls, columns of over head reservoirs, concrete surfaces, under floors etc complete all as specified and directed. |
| 108 | Supply, lay, joint , fix and commission after test, 100mm bore mild steel black column pipes heavy duty duly coated with black water proof paint , both ends flanged, conforming to IS 1239(i) amended upto date, suitable lenghths, suitable for lowering submersible pupm , any lenght complete all as specified and directed. |
| 109 | S&F in repair and replacement 100mm bore Cast iron body sluice valve heavy duty class ‘PN-1.6’, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, complete all as specified and directed. |
| 110 | S&F in repair and replacement 150mm bore Cast iron body sluice valve heavy duty class ‘PN-1.6’, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, complete all as specified and directed. |
| 111 | S&F in repair and replacement 200mm bore Cast iron body sluice valve heavy duty class ‘PN-1.6’, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, complete all as specified and directed. |
| 112 | S&F in repair and replacement 150mm bore Cast iron body Non-Return Valve R/Flap, FL heavy duty , ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, complete all as specified and directed. |
| 113 | M&L for Cast Iron / Ductile Iron fittings ISI marked for spigot and socketed pipe upto 300mm bore such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs, specials, complete all as specified and directed. |
| 114 | M&L for detecting leakage of Sewage pipe line of any pipe, size below 250mm bore from any location, any depth and repairing by providing jointing materials lead, lead wool, flanged, clamps, nuts, washers and nuts and bolts etc complete all as specified and directed. Note:- Lenghth of pipe shall be measured and paid for separately under respective items of BoQ and complaint of leakge shall be rectified within 48 hours of its occurance, other a penal recovery of Rs 2000.00 per complaint per day beyond the time shall be made from contracor's dues. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 10, 2026
11:30 IST
Tender Published
Tender notice published.
TodayOct 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysOct 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 33 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender