Tender For Cleaning And Repair To Sewer Lines, Septic Tanks, Manholes Etc For Otm Accn At Aec Trg College And Centre Pachmarhi
Tender Value
9.90 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
17 days left
EMD
19800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hoshangabad → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Cleaning And Repair To Sewer Lines, Septic Tanks, Manholes Etc For Otm Accn At Aec Trg College And Centre Pachmarhi
BOQ
| Sl. No. | Item Description |
| 1 | Cleaning of chocked sewer line of any dia and depth up to 1.5 mtr manually or by means of mechanical appliances and making sewer line functional including working under foul condition and deposting the sludge off the premises at isolated places not exc 1 KM complete all as specified and directed by Engineer-in-charge. |
| 2 | Dewatering/ Desludgeing of existing septic tank, manually or using mechanical appliances including removal of sludge to a distance not exc 1 KM out side of ministry of defence land at isolated places, of 25 Users capacity complete all as specified and as directed by Engineer-in-charge.Note : Item shall be operated when septic tank are over flowing with sludge. This aspect shall be verified by AGE (I) Pachamrhi in respect of every septic tank before allowing the contractor for cleaning of the same. |
| 3 | Description all as per items serial No 2.00 but 50 Users. |
| 4 | Description all as per items serial No 2.00 but 100 Users. |
| 5 | Description all as per items serial No 2.00 but 150 Users. |
| 6 | Description all as per items serial No 2.00 but 200 Users. |
| 7 | Description all as per items serial No 2.00 but 250 Users. |
| 8 | Desludging of existing manhole of any size upto 1.5 mtr deep, manually or using mechanical appliances including removal of sludge to a distance not exc 1KM out side of ministry of defence land at isolated places complete all as specified and as directed by Engineer-in-charge. |
| 9 | Excavating in trenches, n'exc 1.5M wide and n'exc 1.5M depth; for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc n'exc 10 Sqm on plan and n exc 1.5M in depth and getting out in hard/dense soil complete all as specified and as directed by Engineer-in-charge. |
| 10 | Demolition and breaking up drain pipes (PVC/ SGSW/ AC/ RCC pipe) of 150mm bore of pipe, set in cement mortar complete all as specified and as directed by Engineer-in-charge. |
| 11 | M&L concrete bed to pipes in PCC (1:3:6) type C2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid on slope and tested for 150mm bore sewer pipe line complete all as specified and as directed by Engineer-in-charge. |
| 12 | M&L for salt glazed stone ware (SGSW) pipe conforming to IS, laid in trenches and jointed in CM (1:1) of 150mm bore of pipe complete all as specified and as directed by Engineer-in-charge. |
| 13 | M&L for double wall corrugated (DWC) pipe conforming to IS, laid in trenches and jointed in CM (1:1) of 150mm bore of pipe complete all as specified and as directed by Engineer-in-charge. |
| 14 | Taking down PVC pipe (SWR) 110mm dia bore and connection complete all as specified and as directed by Engineer-in-charge. |
| 15 | Taking down PVC pipe (SWR) 75 mm dia bore and connection complete all as specified and as directed by Engineer-in-charge. |
| 16 | S&F 75 mm dia bore pipe (SWR) single socket in any length rubber joints fixed to wall including clamping complete all as specified and as directed by Engineer-in-charge. |
| 17 | S&F 110 mm dia bore pipe (SWR) single socket in any length rubber joints fixed to wall, complete all as specified and as directed by Engineer-in-charge. |
| 18 | S&F in repairs PVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints with solvent cement, laid in trenches or in floors complete all as specified and as directed by Engineer-in-charge. |
| 19 | S&F for PVC (SWR) bends of 110mm bore complete all as specified and as directed by Engineer-in-charge. |
| 20 | S&F for PVC (SWR) bends of 75mm bore complete all as specified and as directed by Engineer-in-charge. |
| 21 | S&F for 110mm bore PVC (SWR) branch piece, double (double Y) equal or unequal, complete all as specified and as directed by Engineer-in-charge. |
| 22 | S&F for 75mm bore PVC (SWR) branch piece, double (double Y) equal or unequal, complete all as specified and as directed by Engineer-in-charge. |
| 23 | S&F for 110mm bore PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and as directed by Engineer-in-charge. |
| 24 | S&F for 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and as directed by Engineer-in-charge. |
| 25 | S&F in repair for 75 mm bore PVC (SWR) vent cowl including taking out existing unserviceable cowl complete all as specified and as directed by Engineer-in-charge. |
| 26 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and as directed by Engineer-in-charge. |
| 27 | Removal of surplus spoil to a distance n'exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed by Engineer-in-charge. |
| 28 | Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed by Engineer-in-charge. |
| 29 | Demolition of of cement concrete in ground floor and paving n.exc 15cm below or above ground level, complete all as specified and as directed by Engineer-in-charge. |
| 30 | M&L for PCC 1:3:6 Type C-2 (Using 40mm graded stone agg as in foundation/mass concrete filling etc complete all as specified and as directed by Engineer-in-charge. |
| 31 | M&L for brick work with modular brick subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and as directed by Engineer-in-charge. |
| 32 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone agg) as in man hole channel and surface drain slightly rounded or chamfered angles etc complete all as specified and as directed by Engineer-in-charge. |
| 33 | Extra for forming fair finished channel 30cm inner girth in cement concrete using extra cement including rounded or chamfered angles etc complete all as specified and as directed by Engineer-in-charge. |
| 34 | Demolition of cement concrete (reinforcement) in ground floor on paving n exc 15 CM thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge. |
| 35 | M&L for precast reinforced cement concrete (1:2:4) type B1 using 20mm graded stone aggregate for cover slabs of manholes, cover slab set in CM 1:4 side portion only with plain surfaces including necessary form work (reinforcement to be measured and paid separately) complete all as specified and as directed by Engineer-in-charge. |
| 36 | M&L for providing reinforced cement concrete, Type B-1, (1:2:4) (using 20 mm graded aggregate as in slab supported on walls, beams and column in floors roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-charge. |
| 37 | M&L form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (horizointal or slooping ) complete all as specified and as directed by Engineer-in-charge. |
| 38 | M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-charge. |
| 39 | M&L for mild steel TMT bars as in reinforcement, 6 to 08mm dia cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-charge. |
| 40 | Taking down cement plaster on brick/block wall etc including racking out joints hacking for key, scrubbing down with water as described, complete all as specified and as directed by Engineer-in-charge. |
| 41 | M&L rendering 15mm thick in cement mortar 1:4 on fair faces of brick work and to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed by Engineer-in-charge. |
| 42 | M&L for 10mm thick plastering on fair faces of brick wall in CM (1:4), surface finished even and fair mixed with WPC as per manufacturer instructions complete all as specified and as directed by Engineer-in-charge.Note :- WPC shall be measured and paid separately as supply only. |
| 43 | S&F in repair PVC jet spray (butterfly) suitable for europian western commode (EWC) including PVC connection 15mm size with PTMT nut and washer of 900mm length complete all as specified and as directed by Engineer-in-charge. |
| 44 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed by Engineer-in-charge. |
| 45 | Supply only WPC integral water proofing compound complete all as specified and as directed by Engineer-in-charge. |
| 46 | S&F in repair 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by Engineer-in-charge. |
| 47 | S&F vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device, ( excluding fixing bolts, flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, anti -syphonage pipe, etc., complete all as specified and as directed by Engineer-in-charge. |
| 48 | S&F in repair vitreous china squatting pan of “Orissa” pattern of size 580 mmx 440mm white with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and as directed by Engineer-in-charge. |
| 49 | S&F PVC 10 ltrs capacity symphonic action type low level flushing cistern including flush pipe, cantilever brackets incluiding taking down existing cistern etc complete all as specified and as directed by Engineer-in-charge. |
| 50 | S & F in repair for Wash basins, Vitreous China (flat back type) 550 x 400mm, including cutting for and pinning in ends of brackets or erecting stand, waste pipe etc fixed in repairs, complete all as specified and as directed by Engineer-in-charge. |
| 51 | S&F 15 mm bore PVC connector pipe of length 450 mm with PTMT nuts at both ends and fixed in repairs, complete all as specified and as directed by Engineer-in-charge. |
| 52 | S&F 32 mm bore PVC waste pipe, suitable for WHB/urinal and fixed in repairs, complete all as specified and as directed by Engineer-in-charge. |
| 53 | S & F for Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, 15 mm fancy type fixed in repairs, complete all as specified and as directed by Engineer-in-charge. |
| 54 | S&F in repair Chromium plated angular stop cock with wall flange fixed to 15mm bore iron pipe and fixed in repairs, complete all as specified and as directed by Engineer-in-charge. |
| 55 | Cleaning of blockage floor/nahani/bottle trap of wash hand basin/sink/bathrooms/kitchen and WC (any type) by using hand pump with rubber bucket or by cleaning rod till clear flow of water is observed all complete all as specified and as directed by Engineer-in-charge. |
| 56 | M&Ldewatering of existing 500 Ltr water tank by open out let valve, manually including removal of slude/visible sediment ,algae growth inside suface using brush /backing soda and cleaning with cleaning with clean water. Apply disinfectant solution (mixture of 01 part of bleach powder and 25 part of water) on inside surface . Finally clean insde tank with clean water two time complete all as specified and as directed by Engineer-in-charge. |
| 57 | M&Ldewatering of existing 1000 Ltr water tank by open out let valve, manually including removal of slude/visible sediment ,algae growth inside suface using brush /backing soda and cleaning with cleaning with clean water. Apply disinfectant solution (mixture of 01 part of bleach powder and 25 part of water ) on inside surface . Finally clean insde tank with clean water two time complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysOct 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender