Housing Urban and Rular Development Local Bodies Closing in 2 days TDR #57447116

Tender For Maintenance Of Various Sports Complexes.Sub Head : :- Supply And Replacement Of Pa System, Internal And External Electrical Installations At Vksc & Bgnsc.

Issued by Local Bodies · Delhi, Delhi
Tender Value
22.62 Lakhs
Estimated cost
Bid Submission
16 Sep 2026
2 days left
EMD
45255
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Maintenance Of Various Sports Complexes.Sub Head : :- Supply And Replacement Of Pa System, Internal And External Electrical Installations At Vksc & Bgnsc.

BOQ

Name of Work:- Maintenance of Various Sports Complexes.Sub Head : :- Supply and Replacement of PA System, Internal and External electrical installations at VKSC & BGNSC.
Sl. No. Item Description
1Rewiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group C (DSR_2025_1.15)
2Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required i/c rebate.a) Group C(DSR_20251.55.3 )
3Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required i/c rebate. (DSR_2025_1.57)
4Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required i/c rebate.5/6 A switch (DSR_2025_1.24.1)
515/16 A switch
63 pin 5/6 A socket outlet
76 pin 15/16 A socket outlet
8Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required i/c rebate. (But without MCB/RCCB/Isolator).8 way (4 + 24), Double door(DSR_2025_2.4.3)
9LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) etc. as required i/c rebate.36 watt (DSR_2025_8.8.4)
10LED Batten light (System lumen efficacy ≥105 85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 Colour Matching) 1.20 mm) etc. as required i/c rebate.18-22 Watt (DSR_2025_8.9.1)
11Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required i/c rebate.(DSR_2025_1.12)
12Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required etc. as required i/c rebate.(DSR_2025_1.13)
13Supplying and replacement (including deduction of cost for replaced item) of PVC insulated copper wire of following size in the existing surface/ recessed conduit i/c connection, testing etc. as required i/c rebate.a) 1x 1.5 sq.mm
14b) 1x 2.5 sq.mm
15c) 1x 4.0 sq.mm
16Supplying and replacement of following MCB's for Electrical Panel Board/ feeder pillar/ pole including connection, testing etc as reqd i/c rebate.a) 6 to 32 Amp SP MCB \\"C\\" series. (10 KA Capacity)
17b) 6 Amp to 32 Amp DP MCB \\"C\\" series.
18c) 6 Amp to 32 Amp TPN MCB \\"C\\" series.
19Supply and replacement of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) i/c rebate. (DSR_2025_9.2.3)
20Supply and replacement (including deduction of cost for replaced item) of Plastic Ventilation Fan size 200 mm single phase, fixing the same on existing opening with suitable nut bolt fixture and plywood after cutting making hole in plywood, connection, testing etc as reqd. i/c rebate.
21Supply and replacement (including deduction of cost for replaced item) of Heavy Duty Exhaust Fan size 300 mm single phase, fixing the same on existing opening with suitable nut bolt fixture and plywood after cutting making hole in plywood, connection, testing etc as reqd i/c rebate.
22Supply and replacement of Desert coolers having tank capacity 80 liter etc as required .
23Supply, Installation, Testing and Commissioning of Submersible pumps having capacity 5 hp etc as required i/c rebate.
24Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required i/c rebate. : (DSR_2025 : 27.7.8)a) 150 mm dia
25Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc. of following sizes as required: (i/c rebate.) (DSR_2025 : 27.24.3 )a) 150mm dia
26Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as requireda) Upto 35 sq. mm(DSR_2025 :10.5.1)
27b) Above 35 sq. mm and upto 95 sq. mm (DSR_2025 :10.5.2)
28Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) (DSR_2025 :15.16.1)
2990 mm dia (OD-90 mm & ID-76 mm nominal) (DSR_2025 :15.16.2)
30Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required i/c rebate.a) 3½ X 95 sq. mm (45mm) (DSR_2025 :11.1.24)
31b) 4 X 16 sq. mm (28mm) (DSR_2025 :11.1.33)
32Supply, Installation, Testing of 2x1200 watt Power amplifier (2 Channel of 1200 watt each) having of Multiple outputs - 2, 4, 8, 16 Ohms, 70Vrms, 100Vrms DSP – On-board Digital Signal Processor in each amplifier, Mains, battery back-up, and pilot tone supervision Temperature controlled forced front to back ventilation, directly stackable, Dual inputs with priority switching, Frequency response - (8Ω, 20Hz - 20kHz) (±0.25dB), Input Impedance: 10 kΩ balanced, 5 kΩ unblanced, Crosstalk: >80dB, Distortion - <5% at rated output power, 1 kHz, S/N (flat at max volume) i/c connection etc. complete as required i/c rebate.
33Supply, Installation, Testing of 300 watt amplifier with 6 mic/line inputs Inbuilt Bluetooth & USB input, Limiter circuit for protection, Insert feature to use as a pre/power amplifier, i/c connection etc. complete as required. (i/c rebate)
34Supply and Installation of 90watt PA Wall Speaker in High Impact Polystyrene (HIPS), painted with highly-UV resistant paint, 8\\" woofer with woven fiberglass cone, 1” PEI diaphragm tweeter with fluid cooling, high fidelity sound character with broad frequency response of 45 Hz – 20 kHz. The speaker having arrangements of taping 100 Watt power handling (200 Watt program) in direct 8Ω setting, plus built-in 60, 30, 15 Watt on 70V/100V multi-tap transformer i/c connection testing etc. as required i/c rebate.
35Supply, Installation and Testing of Dual 15\\" subwoofer with 500W continuous power. The subwoofer should have a frequency response 40Hz - 250Hz, sensitivity of 94dB and max SPL of 122dB. The subwoofer should have 1 x 500 mm (15 in) driver with 75 mm (3 in) voice-coil, Nominal Impedance: 8 ohms i/c connection etc. complete as required i/c rebate.
36Supply and installation of suitable size custom built equipment rack suitable No’s of selves to accumulate 02 Nos. Mixer Amplifier and its accessories with lockable door’s arrangements etc. as required i/c rebate.
37Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a)20mm (DSR_2025_1.21.1)
38Supply of 2 x 1.5 sqmm transparent FR PVC insulated, twin core copper conductor (Flexible) Industrial Speaker cable). etc. as required. (i/c rebate.)
39Supply of 2 x 2.5 sqmm Industrial Flexible ABC Conductor, PVC Insulated, Overall Shielded by Al-mylar along with ATC drain wire & Overall PVC Sheathed Cable etc. as required i/c rebate.
40LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >105-120 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, 54 DELHI SCHEDULE OF RATES (E&M)-2025 EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) 135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) i/c rebate.200 watt (DSR_2025) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57447116
AUTHORITY Local Bodies
TENDER VALUE 22.62 Lakhs
LAST DATE 16-09-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for Maintenance Of Various Sports Complexes.Sub Head : :- Supply And Replacement Of Pa System, Internal And External Electrical Installations At Vksc & Bgnsc.
Basic Detail
Tender No 35/EE/ELD-3/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 10 Sep 2026
Submission Date 16 Sep 2026
Open Date 17 Sep 2026
Finance
Tender Value 22.62 Lakhs
Tender Fee Ref. Documents
EMD 45255
Exemption Not Available
Document List
BOQ_972665.xls
c2363d13-697d-49db-bf6d-a46d01c7bc6b.html
NIT.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_972665.xls

html

c2363d13-697d-49db-bf6d-a46d01c7bc6b.html

pdf

NIT.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders