Tender For Provision Of Certain E/M Sanction Works (Sr,Rw And Mw) At Aerial Bay, Durgapur, Shibpur Under Ge(South) Diglipur
Tender Value
43.50 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
19 days left
EMD
87000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
North and Middle Andaman → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Certain E/M Sanction Works (Sr,Rw And Mw) At Aerial Bay, Durgapur, Shibpur Under Ge(South) Diglipur
BOQ
| Sl. No. | Item Description |
| 1 | S & F for fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detector 99 module and up to 200 detector and 200 module per loop complete all as specified and as directed. |
| 2 | S & F for complying with any type certified EN 45 addresible type multisensor detector with heat & smoke combination complete all as specified and as directed. |
| 3 | S & F for fire alarm sounders/ Sirens electronic type horizontal single stage continuies normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of (+5) DB, 500 mtr range complete all as specified and as directed. |
| 4 | S & F for Addressable control modular complete all as specified and as directed. |
| 5 | S & F for manual addressable call point resettable type complete all as specified and as directed. |
| 6 | S & F for Addressable sounder complete all as specified and as directed. |
| 7 | Supply, laying & testing PVC insulated, PVC sheathed cable galvinized steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 1.5 sqmm X 2.00 core, 1100 volts complete all as specified and as directed.Note: 2 runs of 1.5 sqmm copper armoured cable and 1 run of PVC conduit will be measured as one unit. |
| 8 | S&F GI tubing medium grade of size 32 mm dia bore ISI marked laying in trench/wall complete with all accessories such as Tees Union,, Bend, Elbow etc all as required at site for cable protection complete all as specified and as directed. |
| 9 | Excavation in trenches n.exc. 1.5 meter width and n.exc. 1.5 meter depth in any type of soil and getting out for pole foundation complete all as specified and as directed. |
| 10 | M&L for PCC (1:4:8) type-D2 (using 40mm graded stone aggregate) as in foundation, filling mass concrete complete all as specified and as directed. |
| 11 | M&L for RCC (1:2:4) type-B1 (using 20mm graded stone aggregate) as in pole foundation, including rafts, footings and mass concrete, complete all as specified and as directed. |
| 12 | M&L for RCC (1:2:4) type-B1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and stuts, complete all as specified and as directed. |
| 13 | Use and Waste for Formwork of square, rectangularor polygonal to side of concrete foundations, footings, bases of colums, raft and raft beams, side and soffits (if any) of foundation and plinth beams, and similar work, vertical or to better complete all as specified and as directed. |
| 14 | Use and Waste for Formwork of square, rectangularor polygonal to side of pillars, posts,stuts, piers, columns and stanchions for fair finished surface complete all as specified and as directed. |
| 15 | M&L for Mild steel TMT bars 10mm dia over as in reinforcement for concrete cut to length, bent to shape required, including cranking, bending, spirally for columns hooking for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 16 | Ditto as per Item No.15 but 6mm dia and over in stirrups, spacer and binder ditto |
| 17 | Returing and filling in including sperading levelling watering and ramming layres n.exc. 25cm complete all as specified and as directed. |
| 18 | Removing excavated material n.exc. 50 meter and deposition where directed at n.exc. 1.5 meter above the starting point complete all as specified and as directed. |
| 19 | Supply, installatoin, testing and commissioning of outdoor type Solar Standalone Street Light including LED Street light, system Voltage 24W, Luminaire Wattage 60W, Limen 6300, in-built Solar Charge Controller MPPT, Solar Panel 250(125x2)Wp, Battery-LMLA 150(75x2)Ah, with HDG Tubler/Oct Pole above ground 7 Mtr Length and Range (2 Days Backup) with all accessories complete all as specified and as directed. |
| 20 | S&F sheet metal enclosure for DBs (double door type) when MCB's to be used, Single pole and neutral, 8 ways including blacking plate with 200 amps rated bus bar, 240 volts fixed sunk/flush to the wall complete all as specified and as directed. |
| 21 | S&F MCB TPN/FP 40 to 100 Amps rating 415V, 10KA with connection and commissioning complete all as specified and as directed. |
| 22 | S&F MCB SP 32 Amps rating 240V, 10KA with connection and commissioning complete all as specified and as directed. |
| 23 | S&F in repair MCB TPN 40 to 100 Amps, 415 Volts, minimum 10 KA, \\"B\\" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and as directed. |
| 24 | S & F in repair MCB SP 5 to 32 Amps, 240 Volts, minimum 10 KA, \\"C\\" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed. |
| 25 | M&L for wiring for circuit/ submain wiring alongwith earth wire with 2x4 sqmm + 1 x4 sqmm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed steel / PVC conduit complete all as specified and as directed.Note: 5 runs of 4.0 sqmm copper cable and 1 run of PVC conduit will be measured as one unit. |
| 26 | Supply, Installation, Testing and commissioning of Online Water monitoring sensors, 220-240 volts, 50/60 Hz, 40 VA, 7\\" resolution, 800x400 pixels, LED backlight capacitive touch screen, stainless steel with epoxy coating, IP 68, micro controller based circuit, automatic wiper, RS 485 output (In-Situ type) as per CPCB guidelines Make NIES Model No-NIES-WA-331 having the following(26.1) parameters with specifications :- |
| 27 | TDS- Standard range 0-10,000 ppm (Accuracy +5%)Hardness (ca++ion)- Standard range- 0-1000 mg/l (Accuracy: <5%)Reisdual chlorine- Standard range- 0-20 mg/l (Accuracy: <+5%)pH- Standard range 0-14 pH (Accuracy :<+5%)Turbidity - Standard ragne 0-4000 ntu (Accuracy :+3%)Nitrates (NO3 ion) - Standard range 0-1000 mg/l (Accuracy: +5%)Iron (Fe++ ion) - Standard range 0-1000 us/cm (Accuracy:+7%)Copper (cu++ion) - Standard range 0-1000 mg/l (Accuracy : +5%)Calcium (Ca++ ion)- Standard range 0-1000 mg/l (Accuracy : +5%)Fluoride (F-ion) - Standard range 0-1000 mg/l (Accuracy : +5%)Chloride (Cl ion)- standard range 0-1000 mg/l (Accuracy\\" +5%)Note: The rates quoted are include necessary infrastructre and utilities, initial testing and supervision at satisfaction of user unit. |
| 28 | Taking down of any description and in any position carefully old unserviceable ACs indoor and outdoor units carefully with stabilizer of any make and capacity with all connecting accessories and deposite to MES store yard for safe custody complete all as specified and as directed. |
| 29 | Supply & install hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of cap of 2.0 TR complete all as specified and as directed. |
| 30 | Supply and install 1.5 Ton Capacity hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2. complete all as specified and as directed. |
| 31 | Ditto all as per item No.29 above but 1.0 TR with 5 star BEE rating ditto |
| 32 | Comprising of the following for Serial Item No. 28 to 30:-(a) Room evaporative indoor unit with speed blower fan of appropriate capacity including PCB, thermostic control, air filter and drain for condesning water.(b) Outdoor condering unit of capacity with condenser fan motor of appropriate capacity 01 No air colled condenser pf capacity -01 No shall be installed outside the building on and including suitable factory made mild steel brackets fixed on wall using fastners for fixing and installation AC’s (c) Refrigerant copper pipe of suction and discharge line with insulation, condensing water drain pipe & protected by suitable sixe of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cabel shall be fixed.(d) Makig good the disturbed surface to amcth the existing surface after pluging the holes etc.Note: (i) Cutting holes in walls/window of any thickenes for installation AC etc connection and making good the disturbed surface to match with the thickness for installation of AC etc, connection and uint rate quoted by contractor (ii) Electircal cable of required size & length to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer.(iii) Coper piping/with insulation (10 fit) and drain piping shall be also deemed to be inclusive in quoted unit rate.(iv) Heavy duty of air conditioner outdoor wall mounting Bracket uint rate quoted by contractor |
| 33 | S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and as directed. |
| 34 | Ditto all as per item No.32 above but of capacity 1 KVA ditto |
| 35 | Ditto all as per item No.32 above but of capacity 5 KVA ditto |
| 36 | S&F new copper tubes of suitable size for suction and discharge lines for split type air conditioner including necessary brazing, wrapping up puff insulation, testing on completion complete all as specified and as directed. |
| 37 | S&F modular surface AC box 4 module with MCB SP 25 Amps in plastic enclosure & unbrakable heavy duty ISI plug top complete all as specified and as directed. |
| 38 | Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity as 40/80 ltrs including taking down old one and deposit in MES store yard for safe custody complete all as specified and as directed. |
| 39 | Supply, installation, commissioning of refrigerator 320 ltrs or nearest capacity frost free BEE 5 star rated double door including taking down old one and deposit in MES store yard for safe custody complete all as specified and as directed. |
| 40 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and as directed. |
| 41 | Ditto all as per item No.39 above but size 16 sqmm 4 core ditto |
| 42 | Supply and laying of DWC (Double Wall Corrugated) HDPE pipe, ISI marked IS 14390 Part-II , of outer dia 50 mm and inner dia 38 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler,'O' Ring etc, for protection of cable complete all as specified and as directed. |
| 43 | Supply and fixing 50mm dia tubes light grade galvanised with all fitting, laid in trenches complete all as specified and as directed. |
| 44 | M&L for sub main wiring with 4 runs of 4.0 sqmm PVC insulated unearthed copper cable multistandard 1100 volts, FRLS grade with drawn in PVC conduit and one run of 4.0 sqmm PVC insulated copper cable as earth continuity conductor drawn in PVC conduit complete all as specified and as directed.Note: 5 runs of 4.0 sqmm copper cable and 1 run of PVC conduit will be measured as one unit. |
| 45 | S&F sheet metal enclosure for DB's Double door, triple pole and neutral, 4 way including blacking plate with 200 amp rated bus bar, 415 volts fixed sunk/flush to the wall complete all as specified and as directed. |
| 46 | S&F sheet metal enclosure for DB's Double door, single pole and neutral, 4 way including blacking plate with 200 amp rated bus bar, 240 volts fixed sunk/flush to the wall complete all as specified and as directed. |
| 47 | M&L for Earthing complete with galvanised steel plate electrode of size 600x600x6.30mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised earth strip 32x6mm by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 40mm bore (Light grade) for protection of earth strip all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar finnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soilwith and including taking down the old one complete all as shown in electrical plate No 3 of SSR Part I 2009 including testing on completion all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysOct 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender