Housing Urban and Rular Development Government Departments Closing in 9 days TDR #57443081

Tender For Construction Of 6 Nos Dsp Residences (4 Nos Police Lines Rohtak, 1 No. Police Station Meham And 1 No. Police Post S La) In District - Rohtak.

Issued by Government Departments · Rohtak, Haryana
Tender Value
6.96 Crore
Estimated cost
Bid Submission
24 Sep 2026
9 days left
EMD
13.92 Lakhs
Bank guarantee accepted
Document Fee
23600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rohtak → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of 6 Nos Dsp Residences (4 Nos Police Lines Rohtak, 1 No. Police Station Meham And 1 No. Police Post S La) In District - Rohtak.

BOQ

Name of Work:- Construction of 6 Nos DSP Residences (4 Nos Police Lines Rohtak, 1 No. Police Station Meham and 1 No. Police Post S la) in District - Rohtak.
Sl. No. Item Description
1[10.15]Extra for using hardener at top surface (3.5Kg /sqm) of trimix M25 to finish surface complete in all respect [Through Rate]
2[10.37.1]Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick [Through Rate]
3[10.38]Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. [Through Rate]
4[10.4]Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. [Through Rate]
5[10.45]Extra for pre finished nosing to treads of steps of marble stone. [Through Rate]
6[10.47]Providing and laying Baroda Green marble stone 17mm and above thick in risers of step, skirting , dado, pillars and wall lining included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. [Through Rate]
7[10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate]
8[10.59]Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. [Through Rate]
9[10.62]Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. [Through Rate]
10[10.63.3]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 3. Size of Tile 800x800 mm [Through Rate]
11[10.67.3]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 3. Size of Tile 800x800 mm [Through Rate]
12[10.70.3]Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 3. Size of Tile 800x800 mm [Through Rate]
13[10.9]Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. [Through Rate]
14[11.100.2]Applying a coat of mordant solution on G.S. sheet: 2. With a solution made of 13 gms of hydrochloric acid in a solution of 13 gms each of copper chloride, copper nitrate and ammonium chloride dissolved in a litre of soft water [Through Rate]
15[11.17]Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge [Through Rate]
16[11.46]Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 and II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls and ceiling at all floors and locations, finished in smooth line and level etc. complete. [Through Rate]
17[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate]
18[11.6.1]15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) [Through Rate]
19[11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. [Through Rate]
20[11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer [Through Rate]
21[11.67.1]Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. Water thinnable cement primer [Through Rate]
22[11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate]
23[11.96.1]Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1. New work (Two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate]
24[12.102.1]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm [Through Rate]
25[12.102.2]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 100 mm [Through Rate]
26[12.103.2]Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 2. Twin rubber stopper [Through Rate]
27[12.104.4]Providing and fixing aluminium casement stays, ISI marked, anodised transparent or dyed to required colour and shade or powder coated or polyester powder coated, with necessary screws etc. complete. 4. Polyester powder coated minimum thickness 50 micron aluminium [Through Rate]
28[12.108.3]Providing fixing aluminium round shape handle of outer dia 100mm with screws etc. complete. 3. Polyester powder coated minimum thickness 50 micron [Through Rate]
29[12.157.2.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate]
30[12.158.2]Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 2. Pre-laminated particle board with decorative lamination on both sides [Through Rate]
31[12.159.1]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 1. With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) [Through Rate]
32[12.159.2]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 2. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) [Through Rate]
33[12.159.3]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 3. With float glass panes of 6 mm thickness (weight not less than 15 kg/sqm) [Through Rate]
34[12.36.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate]
35[12.38.1]Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 1. On one side only [Through Rate]
36[12.98.2]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm [Through Rate]
37[12.99.3]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm [Through Rate]
38[12.99.4]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm [Through Rate]
39[12.99.5]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 5. 100x10 mm [Through Rate]
40[13.2]Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. [Through Rate]
41[13.21.2]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 2. Door Frame of size 125mm x 60mm with 37mm wide double rebate for 35mm door shutter [Through Rate]
42[13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate]
43[17.14.1]Granular Sub-Base with Close Graded Material - (Table:- 400-1) Plant mix method Construction of granular sub-base by providing Material as per Grading III (Table 400-I of MORTandH 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORTandH specifications 1. Grading I material [Through Rate]
44[17.24]Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per technical clause 406 of MORT&H specifications [Through Rate]
45[17.69.1]Interlocking Concrete Block Pavement 1. Providing and Laying 100 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 50 over the bed of 30 mm thick fine sand complete in all respect. [Through Rate]
46[17.8.1]Compaction 1. Extra for laying earth/fly ash as per specifications in 20 cm layers and dressing but excluding the cost of rolling [Through Rate]
47[17.8.2]Compaction 2. Extra for watering the earth/fly ash laid in 20 cm layers as per specifications [Through Rate]
48[17.8.3]Compaction 3. Extra for rolling to specifications [Through Rate]
49[20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) [Through Rate]
50[20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate]
51[21.84.1]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 1. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping [Through Rate]
52[21.84.3]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) [Through Rate]
53[21.85.3]Extra for every 0.30 metre depth of Inspection chamber 3. 600 mm x 900 mm inside [Through Rate]
54[21.90.2.1]Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers up to the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surface where required, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in-charge. 2.1. On 150 mm internal diameter pipe sewer -for 1.20 meters depth below ground level [Through Rate]
55[22.103.1]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 1. 15 mm nominal bore [Through Rate]
56[22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate]
57[22.105.1]Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore [Through Rate]
58[22.106.1]Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore [Through Rate]
59[22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore [Through Rate]
60[22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate]
61[22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. [Through Rate]
62[22.119.2]Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 2. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. [Through Rate]
63[22.166.1.2]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.2. 100x100 mm size P type With Sewer bricks conforming to IS : 4885 [Through Rate]
64[22.166.2.2]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 2.2. 150 x 100 mm size P type With sewer bricks conforming to IS : 4885 [Through Rate]
65[22.166.3.2]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.2. 180x150 mm size P type With Sewer bricks conforming to IS : 4885 [Through Rate]
66[22.182]Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet and over flow pipes. The base support i/c fittings and fixtures for tank shall be paid separately. [Through Rate]
67[22.190.1.2]Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 1.2. Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885 [Through Rate]
68[22.190.2.2]Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 2.2. Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With Sewer bricks conforming to IS : 4885 [Through Rate]
69[22.191.1.2]Extra for depth for manholes : 1.2. Size 90x80 cm With Sewer bricks conforming to IS : 4885 [Through Rate]
70[22.191.2.2]Extra for depth for manholes : 2.2. Size 120x90 cm With Sewer bricks conforming to IS : 4885 [Through Rate]
71[22.218.1]Providing and Supplying of class SN 8 structured wall Polyethylene Piping system (Pipe with online/ offline coupler and elastomeric sealing ring) with non smooth external annular corrugated and smooth internal surface (double wall) for non-pressure underground sewerage and drainage application as confirm to IS 16098 (part II):2013 including transportation, frieght charges, inspection charges, loading, unloading, complete as specified and directed by Engineer In-Charge. 1. 250 mm Internal Diameter [Through Rate]
72[22.218.2]Providing and Supplying of class SN 8 structured wall Polyethylene Piping system (Pipe with online/ offline coupler and elastomeric sealing ring) with non smooth external annular corrugated and smooth internal surface (double wall) for non-pressure underground sewerage and drainage application as confirm to IS 16098 (part II):2013 including transportation, frieght charges, inspection charges, loading, unloading, complete as specified and directed by Engineer In-Charge. 2. 300 mm Internal Diameter [Through Rate]
73[22.219.1]Lowering, Laying and jointing of class SN 8 structured wall (External Annular Corrugated and Smooth Internal Surface Polyethylene Piping and fitting with the help of coupler(online/ offline) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the spigot end, lowering the same into the trench, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient, depth and alignment, testing the water tightness of the joints, ensuring the continuity tests of specified pipe segment etc. complete as per drawing, specification and detailed engineering, including cartage of pipes and fitting etc. as per direction of Engineer-in-charge. 1. 1250 mm Internal Diameter [Through Rate]
74[22.219.2]Lowering, Laying and jointing of class SN 8 structured wall (External Annular Corrugated and Smooth Internal Surface Polyethylene Piping and fitting with the help of coupler(online/ offline) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the spigot end, lowering the same into the trench, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient, depth and alignment, testing the water tightness of the joints, ensuring the continuity tests of specified pipe segment etc. complete as per drawing, specification and detailed engineering, including cartage of pipes and fitting etc. as per direction of Engineer-in-charge. 2. 300 mm Internal Diameter [Through Rate]
75[22.221.2]Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 2. Size 550 mm x 400 mm x 815 mm [Through Rate]
76[22.222.1.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 1.2. Single Socket Type A 110mm o/d SWR UPVC pipe lines laid complete [Through Rate]
77[22.222.1.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 1.3. Single Socket Type A 90mm o/d SWR UPVC pipe lines laid complete [Through Rate]
78[22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete [Through Rate]
79[22.222.2.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete [Through Rate]
80[22.24.1]Providing and fixing white vitreous chinaware pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaware flushing cistern and C.P. flush bend with fittings and C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 1. W.C. pan with ISI marked white solid plastic seat and lid [Through Rate]
81[22.33]Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. [Through Rate]
82[22.35]Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. [Through Rate]
83[22.81.1]Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 1. 100 mm dia [Through Rate]
84[22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate]
85[22.87.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 3. 25 mm nominal outer dia Pipes [Through Rate]
86[22.99.2.1]Providing and fixing gun metal non- return valve of approved quality (screwed end) : 2.1. 32 mm nominal bore Horizontal [Through Rate]
87[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA [Through Rate]
88[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate]
89[23.22.4.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.12. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 12 way ( 8 incoming 3phase*12 outgoing) [Through Rate]
90[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
91[23.23.10]MISCELLANEOUS 10. Supplying and drawing of 1 no UTP 4 pair CAT 6a LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]
92[23.24.4.1]MS STAND, BUS BAR CHAMBER AND PANELS 4.1. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 4 way 250 amp. [Through Rate]
93[23.28.11.6]Supplying, installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , Flicker free (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 6. CRCA Sheet Body (Thickness >= 0.50 mm) 18-22 Watt [Rate]
94[23.28.17.3]Supplying, installation, Testing and Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-10, CRI )80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 3. 100 watt [Rate]
95[23.28.3.4]Supplying, installation, Testing and Commissioning of LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 4. Powder coated die cast / Extruded aluminum Body including trim 18 watt [Rate]
96[23.4.1.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A [Through Rate]
97[23.4.4.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.1. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A [Through Rate]
98[23.4.5.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.1. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A [Through Rate]
99[23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
100[23.5.6.2]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate]
101[23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate]
102[23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate]
103[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
104[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
105[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
106[24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) [Through Rate]
107[24.13.48]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 48. 50 Sq mm 4 core (Arm.) [Through Rate]
108[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]
109[25.11.2.3]HI - WALL SPLIT SYSTEMS Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS:1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature). 3. Inverter Type- Cooling only 1.5 TR with 5 Star BEE Rating [Rate]
110[3.1.2]By Mechanical Transport including loading, unloading and stacking 2. Earth [5km]
111[3.1.2]By Mechanical Transport including loading, unloading and stacking 2. Earth [Beyond 5km up to 10km per KM]
112[3.2.2]By Manual Labour including loading, unloading and stacking for lead less than 0.50 KM 2. Earth [Cost of carriage including loading, unloading & stacking for first 50 metres]
113[3.2.2]By Manual Labour including loading, unloading and stacking for lead less than 0.50 KM 2. Earth [Every additional lead of 50m or part thereof beyond1st 50 m up to 9 such additional lead]
114[4.1]Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. [Through Rate]
115[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
116[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate]
117[4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate]
118[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate]
119[4.33]Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. [Through Rate]
120[6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate]
121[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate]
122[6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) [Through Rate]
123[6.15.1]Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate]
124[6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate]
125[6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate]
126[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate]
127[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate]
128[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate]
129[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate]
130[6.39.1]Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate]
131[6.49.1]Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 1. 50 mm thick [Through Rate]
132[7.20.1]Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
133[7.20.2]Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement Mortar 1:6 (1 cement : 6 coarse sand) [Through Rate]
134[7.22.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
135[7.28.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) [Through Rate]
136[7.50]Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor IV level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos. 6 mm dia M.S. bars at every third course of masonry work. [Through Rate]
137[7.51]Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). [Through Rate]
138[7.55]Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay non-modular bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). [Through Rate]
139[8.17]Providing and fixing manufactured jali of reinforced cement concrete consisting of cement , coarse sand and 10mm and down gauge bajri in ratio of 1:1:2 with 8mm dia tor steel. Outer frame of the jail will be 50mm wide and 25mm thick and inner frame of jali will be 25mm wide and 25mm thick with smooth finish as per design approved by the Engineer-in-Charge including fixing in position up to any height with cement sand mortar 1:4 complete in all respect. [Through Rate]
140[9.10.1]Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 1. With residual type petroleum bitumen of grade VG -10 [Through Rate]
141[9.12.1]10cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow-dung) and covered with machine moulded tile bricks, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat. 1. With machine moulded common burnt clay non-modular brick tiles of class designation 12.5, conforming to IS 2690 [Through Rate]
142[9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase [Through Rate]
143[9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate]
144Providing and applying 12-15mm ready mix/ ready plaster RP cement based plaster mortar having density 1500-1600 per m cum and compressive strength in 28 days 10-12 MPA on cement concrete/reinforcement concrete/brick work/AAC Block of approved make as per satisfaction of Engineer in Charge.....
145Supply, Installation, Testing and Commissioning of 55` LED Displays and wall mount with other accessories 55` 4K- Display UHD (3840 X 2160), min 300 Cd/m2 or better, Android, USB 2.0 or better x 2, HDMI IN x 2 or better, RJ-45 X 1, RS232 X 1, Audio IN X1, Audio Out x 1, Digital Audio Out, built in speaker, 24/7 operation.
146S/I/T/C of Energy Meter Panel indoor type dust and vermin proof for 6 nos Single phase Energy Meters but without cost of energy Meters compartmentalized (app. size 1200x1500x300)mm cubical panel made out of 2 mm thick CRCA sheet wall/ floor mounting duly painted by 2 coat of Zinc / Red oxide primer followed by 2coats of powder coating with 7 tank process in grey or required shade after rinsing as per specifications having 1no.100 Amp.25KA FPMCCB with rotary handle as incommer and for outgoings 6nos. 63 Amp. 10KA SPN Mcb`s , IPN Copper Bus bar of required rating ,10sqmm copper cable of required length from bus bar to meterand meter to SPN Mcb for connections, Digital AF metering , control wiring , required hardware, 3mm thick bakelite sheet provided all along the bus bar . The sub panel having PU/ Neoprene rubber gasket of not less than 3mm thickness separate detachable gland plate , hinged door with inter locking arrangement . The panel will be complete with all labour and other petty material required to complete the job upto satisfaction of Engineerincharge.The Drawing of energy metering panel should be got approved from the Engineer-in- Charge of the work before fabrication. /[3Q]
147Supply and erection of co-axial TV cable (RG-6) with electrolytic grade solid bare copper conductor, gas injected physical foamed polythylene insulation, screened with laminated aluminium tape and aluminium alloy wire braided, jelly flooded and UV grade PVC jacketed in existing pipe, complete in all respect including making necessary connections and labour etc. /[3Q]
148Providing and Fixing Sink Coupling etc. complete in all respect (3Q)
149Providing and Fixing CP Waste Coupling etc. complete in all respect (3Q)
150Providing and Fixing Tank Nipple 1” etc. complete in all respect (3Q)
151Providing and fixing PVC Tank cover etc. complete in all respect (3Q)
152Providing and Fixing CP Flunch etc. complete in all respect (3Q).
153Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect. 110MM DIA, COWEL (3Q).
154Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect )110mm Socket (3Q).
155P and F SWR PVC pipe (90mm dia) classic `B` specials ISI marked Fittings (Kisan, Prince, Finolex make) PLAIN BEND. (3Q)
156Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe (90mm dia) class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect ) Cowel. (3Q)
157Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe (90mm dia) class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect) Socket. (3Q)
158Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe (90MM DIA) class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect (FLOOR TRAP). (3Q)
159Providing and fixing CPVC fittings of ISI Marked, Prince make, complete in all respect (Union 25mm). (3Q)
160Providing and fixing CPVC fittings of ISI Marked, Prince make, complete in all respect (Union 40mm). (3Q)
161Providing and fixing CPVC fittings of ISI Marked, Prince make, complete in all respect Ball Valve (Union Type) 25mm. (3Q)
162Providing and fixing CPVC fittings of ISI Marked, Prince make, complete in all respect Ball Valve (Union Type) 40mm. (3Q)
163Supply and fixing Concertina coils of 600mm with 6 line of RBT complete in all respect (3Q)..
164Providing and fixing SWR PVC pipe (110mm dia) classic `B` specials ISI Marked fitting (KISHAN, PRINCE, FINOLEX MAKE) PVC CLAMP. (Three quotation)
165Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect. 90MM DIA, PVC CLAMP. (Three quotation)
166Bored cast in situ M25 grade R.C.C Pile using Hydraulic Rig excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead up to 1000m (HSR NO. 15.28 drived rate). Pile diameter 300mm, M-25 Grade.(NEW)
167Supply Installation Testing and Commissioning of 8 Port PoE Network Switch for Field equipment 1. Ports 10BASE-T/100BASE-TX/1000BASE-T: 8 Port POE plus 2 100/1000 Mbps SFP ports 2. Switch Category Gigabit Managed Switches 3. Performance Switching Capacity: 20 Gbps, Min Packet Forwarding Rate: 14 Mpps, MAC Address Table: 8K and 1 Mb Packet Buffer, Static MAC Entries: 256 entries 4. Physical Features Power Supply: Internal redundant AC Power Supply, min 130 W, Power Saving (Green) 5. Layer 2 Features Spanning Tree (STP) 802.1d, RSTP 802.1w , 802.1s MSTP, Loopback Detection, Link Aggregation LACP 802.3ad, Port Mirroring: One-to-One, Jumbo Frame: 9K Bytes, Dual image and Dual configuration, Multicast Filtering 6. Layer 2 Multicast Features Internet Group Management Protocol (IGMP) Snooping : v1 / v2/v3, IGMP Snooping Groups : 256 7. Virtual LAN (VLAN) Features Tagged VLAN 802.1Q, 256 Static VLANs, Auto Voice and Surveillance VLAN, Asymmetric VLAN 8. Quality of Service (QoS) Features No. of Queues : 4 Queues per port, Traffic Prioritization 802.1p, Strict Priority, Weighted Round Robin (WRR), QoS based on Switch Port, QoS based on 802.1p Priority, QoS based on Differentiated Services Code Point (DSCP), Bandwidth Control: Port-based (Ingress/Egress, min granularity 10/100/1000 is 16 Kbps) 9. Access Control List (ACL) Features Access Control List based on: • 802.1p priority • VLAN • MAC address• Ether type • IP address • DSCP • Protocol type • TCP/UDP port number • IPv6 Traffic Class Max. ACL Profiles / Rules: 50 10. AAA 802.1X Authentication • Supports local/RADIUS database • Supports port-based access control • Supports EAP, OTP, TLS, TTLS • Max. 128 entries when using local database • IPv6 RADIUS server • Support MD5 authentication 11. Security Features DoS attack prevention, Port Security: Max. 64 MAC Addresses per Port, Broadcast/Multicast/Unicast Storm Control, DHCP Server Screening ARP Spoofing Prevention, Support 2 IP Interface and IPv6 Neighbor Discovery (ND), Traffic segmentation..
168Earth cost or compensation for earth taken from private land as per Unique code RM079.
169Supply and Erection of 4 KVA Copper Wound Voltage Stabilizer, Power input-170-250 Volt AC, Power output-230 Volt AC, Watts-4000, single booster, phase-single phase, display- digital, relative humidity(90%, surge indicator, wall mount, circuit breaker- yes, built in thermal overload protection. excessive current consumption due to component damage or interval short circuit in the circuitry or the PCB or the wiring can lead to overheating of device, initial time delay of 30-120 seconds, low and high voltage cut-off, including wall mount accessories. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
170Supply of Erection of L- Bracket Outdoor Stand made of Mild Steel (MS) or Galvanized Iron (GI), 3.0 mm – 4.0 mm thick. Having bearing Load Capacity 80 kg – 150 kg Powder-coated or anti-rust epoxy primer with weather-resistant paint with 10 mm anti-vibration rubber pads. Including material required for erection i.e. Wall Anchors: 4–6 heavy-duty M10/M12 anchor fasteners etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
171Supply and Installation of Copper refrigerant pipe Liquid Line: 1/4`, Suction Line: 1/2` (with 2.5 Sqmm 3/4 core copper flexible cable of approved make) for 1.5 TN A.C. of suitable size with tubular insulation, recess/ surface (as required), including cost of jointing of pipe. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. Make- Totaline/ Metatube/ Hitachi (Ryaku).
172Supply and Erection 10TB Surveillance Hard Disk Drive (HDD) is a specialized storage unit designed for the high-intensity, `always-on` environment of video recording systems (NVR/DVR). Unlike standard desktop drives, these are built to prioritize constant write operations from multiple camera streams. Form Facto 3.5-inch, Interface SATA III (6 Gb/s), Rotational Speed 7200 RPM (High Performance), Cache Size 256 MB, Recording Tech CMR (Conventional Magnetic Recording) — Ideal for random writes etc. complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work.
173Supply, Installation, Testing and Commissioning of 6U rack for switch Mounting with 6U x 500 W x 500 D indoor rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit. Front Glass Door (tinted, Toughened) with Lock and Key. 2 pairs of 19` Mounting Rails with U-Marking. Provision to mount cooling fans Unit / 90 CFM /230V AC (1 No) on the top panel. Rack shall Conforms to DIN 41494 OR equivalent ISO Standards. Welded Side Walls, CRCA steel Frame and powder coated with highest quality standards. 19” Mounting angles made of formed steel. Depth adjustable mounting slots for verticals provide better mounting flexibility and maximizes the usable mounting space. Top and bottom Panel with ventilation and cable entry facility. Rack Powder coated finish with pretreatment process meeting all industry standards. Grounding and Bonding Options. 100% assured compatibility with all equipment conforming to DIN 41494 (General industrial standard for equipment). Rack Welded to Frame Top and Bottom Cover, Vented and Field Cable entry exit cut outs. Standard Accessories: 1U Cable Manager (1), Hardware Pkt of 20 (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Standard Color : Grey, Static Load : 40 kgs.
174Supply, installation, testing and commissioning of 5MP Bullet Camera with Lens 3.6 mm Fixed lens, IR Range 30 Mtr. , SD Slot and audio supported , IP67, IK10 with following specifications: - Image Sensor: -1/1.8”, 5MP Low Illumination Progressive Scan CMOS Sensor Lens: - 3.6mm fixed lens, 5MP (2560(H)x1920(V)) at 25/30 fps with 30 Meter of inbuilt IR, IP 67 and IK 10 rated Resolution: - 5MP 2560(H)x1920(V) at 25/30 fps Min Illumination: - 0.001Lux @ (F1.2, AGC ON), 0.014 Lux @ (F1.4, AGC ON), 0 Lux with IR Day/Night: - Auto (ICR) / Color / BW WDR: - 120 dB S/N Ratio = 50 dB Video Compression: - H.265/H.264/MJPEG Motion Detection: - Yes Alarm Trigger: - Motion Detection, Network Disconnection, Smart Event - Motion Detection - Set Detection Area, Period, Can Set Multi-Level Sensitivity, Tamper Detection - Alerts when the camera is blocked, defocused, or tampered intentionally or unintentionally ,External Input, Audio Alarm, IP Address conflict, illegal Access, Storage anomaly: Iris Control: - Auto Frame Rate: - 1fps - 25/30fps Network Protocol: - ONVIF Profile - S,G,T : Individually configured minimum 04 video streams 2 Way Audio: - Yes Motion Detection: - Yes SD Card: - Minimum 256 GB on-board Class 10 speed SD Card having Linux Unified card encryption key Video In/Out / Other Features: - WDR, BLC, HLC: 120dB WDR: White Balance - Auto / Tungsten / Daylight / Manual: Gain Control 0~100%: 2D/3D DNR: EIS: DEFOG: Minimum 5 Areas of Privacy Masking: Smart IR Light Controller (Auto/Manual)/OFF : TDN - Auto (ICR) / Color / BW Audio In/Out: - 1 in/ 1 out Alarm In/Out: - 1 in/1out Ethernet: - RJ-45 10/100 Base T Security: - Authorized username and password, HTTPS with password, HTTPS digest authentication Watermark, RTSPS, AES 256 encryption, Signed Firmware, TEE (Trusted Execution Environment), User Authentication and encrypted firmware, Hardware Secure Boot Protocol: - TCP/IP, IPv4, IPv6, SSL, TLS, UDP, HTTP/HTTPS, HTTP-Base64, HTTP-Digest, DHCP, DNS, RTP,RTSP , NTP, SMTP, IGMP, Multicast Operating Temperature: - Temperature: -40 °C ~ 70 °C/ Humidity: 0-90% RH , Ingress Protection: - Weather Proof IP67: IK10 IR Range: -30 m with inbuilt IR Light Controller for Auto / Manual / OFF including a minimum of 04 nos of IR Lights : ONVIF - G, S, T, Certifications - CE, FCC, BIS, STQC i.e as Meity Guidelines : ER : Essential Requirement(s) for Security of CCTV have been published in Ministry of Electronics and information Technology (MeitY) Public Procurement (Preference to Make in India) Order 2017-Notifying CCTV/ Video Surveillance System for Security in furtherance of the Order dated 6th March,2024 along with Trusted Supply Chain. The testing agency authorized to do the Essential Requirement testing is STQC or any other agency notified by MeitY from time to time. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
175Supply, installation, testing and commissioning of 5MP Dome Camera with Lens 3.6 mm Fixed lens, IR Range 30 Mtr. , SD Slot and audio supported , IP67, IK10 with following specifications: - Image Sensor: -1/1.8”, 5MP Low Illumination Progressive Scan CMOS Sensor Lens: - 3.6mm fixed lens, 5MP (2560(H)x1920(V)) at 25/30 fps with 30 Meter of inbuilt IR, IP 67 and IK 10 rated Resolution: - 5MP 2560(H)x1920(V) at 25/30 fps Min Illumination: - 0.001Lux @ (F1.2, AGC ON), 0.014 Lux @ (F1.4, AGC ON), 0 Lux with IR Day/Night: - Auto (ICR) / Color / BW WDR: - 120 dB S/N Ratio = 50 dB Video Compression: - H.265/H.264/MJPEG Motion Detection: - Yes Alarm Trigger: - Motion Detection, Network Disconnection, Smart Event - Motion Detection - Set Detection Area, Period, Can Set Multi-Level Sensitivity, Tamper Detection - Alerts when the camera is blocked, defocused, or tampered intentionally or unintentionally, External Input, Audio Alarm, IP Address conflict, illegal Access, Storage anomaly: Iris Control: - Auto Frame Rate: - 1fps - 25/30fps Network Protocol: - ONVIF Profile - S,G,T : Individually configured minimum 04 video streams 2 Way Audio: - Yes Motion Detection: - Yes SD Card: - Minimum 256 GB on-board Class 10 speed SD Card having Linux Unified card encryption key Video In/Out / Other Features: - WDR, BLC, HLC: 120dB WDR: White Balance - Auto / Tungsten / Daylight / Manual: Gain Control 0~100%: 2D/3D DNR: EIS: DEFOG: Minimum 5 Areas of Privacy Masking: Smart IR Light Controller (Auto/Manual)/OFF : TDN - Auto (ICR) / Color / BW Audio In/Out: - 1 in/ 1 out Alarm In/Out: - 1 in/1out Ethernet: - RJ-45 10/100 Base T Security: - Authorized username and password, HTTPS with password, HTTPS digest authentication Watermark, RTSPS, AES 256 encryption, Signed Firmware, TEE (Trusted Execution Environment), User Authentication and encrypted firmware, Hardware Secure Boot Protocol: - TCP/IP, IPv4, IPv6, SSL, TLS, UDP, HTTP/HTTPS, HTTP-Base64, HTTP-Digest, DHCP, DNS, RTP,RTSP , NTP, SMTP, IGMP, Multicast Operating Temperature: - Temperature: -40 °C ~ 70 °C/ Humidity: 0-90% RH , Ingress Protection: - Weather Proof IP67: IK10 IR Range: -30 m with inbuilt IR Light Controller for Auto / Manual / OFF including a minimum of 04 nos of IR Lights : ONVIF - G, S, T : Certifications - CE, FCC, BIS, STQC i.e as Meity Guidelines : ER : Essential Requirement(s) for Security of CCTV have been published in Ministry of Electronics and information Technology (MeitY) Public Procurement (Preference to Make in India) Order 2017-Notifying CCTV/ Video Surveillance System for Security in furtherance of the Order dated 6th March,2024 along with Trusted Supply Chain. The testing agency authorized to do the Essential Requirement testing is STQC or any other agency notified by MeitY from time to time. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
176Supply, installation, testing and commissioning of NVR- 16 Channel, with Incoming and outgoing bandwidth of 270 Mbps, minimum 2 SATA port , support of minimum 32 TB storage (2 no`s HDD X 16 TB each) with minimum features: supporting channel :36 channels, Bandwidth :150 Mbps (Incoming)/120 Mbps (Outgoing) Recording Resolution: Upto 12 MP Video Output: 1 HDMI, 1 VGA Ports, USB interface:3xUSB 2.0, Minimum Support up to 16TB at Each SATA Port, Alerts: Generate alerts for camera or equipment malfunction and replacement, HDD failures, HDD tampering, etc. Auto start/ Resume :should be capable of auto start/Resume operations post power fluctuation/ failure Access Management: Feature to limit access to storage data with access management Connectivity Interface:1 Nos. x 10/100/1000 Base-T Lan Port Backup, Operating Condition:0°C to 55°C, humidity 80% (max), System Capability: Should be ONVIF Profile G, S and T Note: Quoted Model should be listed on ONVIF website and NVR OEM should not be blacklisted by ONVIF. Certifications: BIS Certified, UL/CE/FCC Additional feature - Auto resume, VMS: Must have pre-loaded VMS, ONVIF complaint. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
177SITC of LED Post Top Luminaire (45–50 W) complete with built-in LED module, suitable for mounting on a Ø76 mm OD pole. The luminaire shall operate on 240 VAC, with CCT options of 3000 K, 4000 K, or 5700 K, minimum CRI 80, MacAdam Step 3, and minimum system efficacy of 120 lm/W. It shall have 360° light distribution, IP65 protection, ON/OFF electronic driver with minimum 88% efficiency, power factor =0.96, THD =10%, and 6 kV surge protection. Housing shall be of die-cast/spun aluminium with clear acrylic diffuser, stainless steel fasteners, and polyester powder-coated finish. The luminaire shall have an L70B10 life of at least 50,000 hours at 40°C, operating temperature from –15°C to plus 50°C, and comply with LM-79, LM-80, TM-21, and BIS certification, complete with all accessories, installation, testing, commissioning, and satisfactory operation as directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57443081
AUTHORITY Government Departments
TENDER VALUE 6.96 Crore
LAST DATE 24-09-2026
Authority
Authority Name Haryana Police Housing Corporation Limited
Work Description Tender for Construction Of 6 Nos Dsp Residences (4 Nos Police Lines Rohtak, 1 No. Police Station Meham And 1 No. Police Post S La) In District - Rohtak.
Basic Detail
Tender No 202692D6BCDB D928 4D00 97BB EB44E730650C57HHC
Bidding Type Tender
Location
City Rohtak
State Haryana
Key Dates
Publish Date 10 Sep 2026
Submission Date 24 Sep 2026
Open Date 25 Sep 2026
Finance
Tender Value 6.96 Crore
Tender Fee 23600
EMD 13.92 Lakhs
Exemption Available
Document List
1YBA99Z174510.pdf
BOQ_625554.xls
d23e05cc-4b08-4cd3-8d56-26e8418f82e8.html
OT0174510.pdf
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

1YBA99Z174510.pdf

xls

BOQ_625554.xls

html

d23e05cc-4b08-4cd3-8d56-26e8418f82e8.html

pdf

OT0174510.pdf

pdf

Tendernotice_1 (19).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders