Tender For Comm. Of Tw Drilled By Dept. Rig Including Supply And Installation Of Energy Efficient Submersible Pump Sets & Other Allied Works Under Rwss Jurisdiction Div. Nagaur (Arc)
Tender Value
1.60 Crore
Estimated cost
Bid Submission
17 Sep 2026
1 days left
EMD
3.20 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nagaur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Comm. Of Tw Drilled By Dept. Rig Including Supply And Installation Of Energy Efficient Submersible Pump Sets & Other Allied Works Under Rwss Jurisdiction Div. Nagaur (Arc)
BOQ
| Sl. No. | Item Description |
| 1 | Providing & lowering in tubewell ISI marked GI Pipe \\"B\\" class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3 mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect |
| 2 | nominal bore of 32 mm |
| 3 | nominal bore of 50 mm |
| 4 | nominal bore of 65 mm |
| 5 | Supply & fixing of ISI marked three core PVC flat submersible cable as per IS 694 : 1990 or amended up to date and conductor as per class 5 of IS 8130 : 1980 including making connecting etc |
| 6 | 3 core 4.0 Sq.mm |
| 7 | 3 core 6 Sqmm |
| 8 | 3 core 10 Sqmm |
| 9 | 3 core 16 Sq mm |
| 10 | Supply & Installation of 3 phase ISi marked submersible motor pump set of five star rating by BEE and as per JS: 8034-2011 (pump) and IS 9283-2013 (motor) or amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. |
| 11 | Up to 5.5 KW (7.5 HP) & head up to 120 mtr. |
| 12 | Up to 5.5 KW (7.5 HP) & head above 120 mtr |
| 13 | 7.5 KW (1O HP) & head up to 120 mtr. |
| 14 | 7.5 KW (10 HP) & head above 120 mtr. |
| 15 | 9.3 KW (12.5 HP) & head up to 120 mtr |
| 16 | 9.3 KW (12.5 HP) & head above 120 mt |
| 17 | 11 KW (15 HP) & head up to 120 mtr. |
| 18 | 11 KW (IS HP) & head above 120 mtr |
| 19 | 13 KW (17.5 HP) & head up to 120 rntr. |
| 20 | 13 KW (17.5 HP) & head above 120 mtr |
| 21 | 15 KW (20 HP) and above, head up to 120 mtr |
| 22 | 15 KW (20 HP) and above, head above 120 mtr. |
| 23 | Supply & installation of single phase ISI marked submersible motor pump set of 96 mm dia five star rating by BEE and as per IS : 8034-2018 (pump) and IS 9283-2013 (motor) or amended upto date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables upto switch board, testing of submersible pump set and interconnection upto water mains, complete in all respect |
| 24 | Up to 2.0 KW |
| 25 | Above 2.0 KW |
| 26 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. |
| 27 | Above 5 HP and up to 10 HP |
| 28 | Above 10 HP and up to 15 HP |
| 29 | Above 15 HP and up to 20 HP |
| 30 | Above 20 HP and up to 30 HP |
| 31 | Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply. |
| 32 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & Smm thick I OOmm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both end in 80mm sizes passing through a hole in the centre of MS sheet. A 25mm socket with end plug shall also be welded over top plate (as per drawillg enclosed). A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall tie provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. |
| 33 | 125 mm dia |
| 34 | 150 mm dia |
| 35 | 200 mm dia |
| 36 | 250 mm dia |
| 37 | Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 406411 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia |
| 38 | 50 mm dia |
| 39 | 65 mm dia |
| 40 | 80 mm dia |
| 41 | Providing & Fixing pump safety cage as per specifications or as directed by engineer incharge |
| 42 | Providing & Fixing of double flanged, Cl body, ISi marked NR V of approved make of following sizes |
| 43 | 65 mm dia |
| 44 | 80 mm dia |
| 45 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated CI Sluice valve of Class PN-1.0 |
| 46 | 80 MM |
| 47 | 100 MM |
| 48 | 125 MM |
| 49 | 150 MM |
| 50 | 200 MM |
| 51 | 250 MM |
| 52 | 300 MM |
| 53 | Providing and Fixing of ISI marked PVC storage tank of following capacity as per IS: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long GI overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket, including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and PVC ball complete with brass weight 1000 gm, including P&F 15mm dia CI quarter turn heavy duty Bib Cocks four no's of superior quality and approved make, including interconnections complete job. |
| 54 | 1000 litres capaicty |
| 55 | 2000 litres capaicty |
| 56 | Fabrication & Fixing M.S. Stand of specified class of angle iron L-shaped of 50 mm size with four legs grouted by 300*300*300 mm CC Block M-15 in the ground and all legs tied up with each other through same size of angle iron along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. PVC tank complete in all respect. |
| 57 | Supply & fixing MS clamp set of 50 x 6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump sets |
| 58 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 |
| 59 | 80 mm dia |
| 60 | 100 mm dia |
| 61 | 125 mm dia |
| 62 | 150 mm dia |
| 63 | 200 mm dia |
| 64 | 250 mm dia |
| 65 | 300 mm dia |
| 66 | 350 mm dia |
| 67 | 400 mm dia |
| 68 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 |
| 69 | 80 mm dia |
| 70 | 100 mm dia. |
| 71 | 125 mm dia. |
| 72 | 150 mm dia. |
| 73 | 200 mm dia. |
| 74 | 250 mm dia. |
| 75 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 76 | EFM 80 mm |
| 77 | EFM100 mm |
| 78 | EFM 125 mm |
| 79 | EFM 150 mm |
| 80 | EFM 200 mm |
| 81 | EFM 250 mm |
| 82 | EFM 300 mm |
| 83 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 84 | 10.0 Sq.mm, 4 core |
| 85 | 16.0 Sq.mm, 4 core |
| 86 | 25.0 Sq.mm, 3.5 core |
| 87 | 35.0 Sq.mm, 3.5 core |
| 88 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 89 | Proving and Fixing 32 mm dia Full way valve or wheel valve as per IS:778 or amended up to date of approved make, on pump delivery pipe. |
| 90 | Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover. |
| 91 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. |
| 92 | MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet) |
| 93 | SITC of Digital Type Single Phase DOL Starter Electrical Control Feeder Panel, 63A, suitable for operation of Single-phase pump set on 215V AC supply, comprising input MCB (DP 63A.), GFU with auxiliary contact for earth fault protection, AC-3 duty PMC based DC contactors 50 Amp. 1P (DOL type), Microprocessor basedDigital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal, connectors, complete internal wiring with copper conductors (for control and power), capacitor bank and all necessary hardware. The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. |
| 94 | Upto 5 HP (Single Phase) |
| 95 | SITC of Digital Type DOL Starter Electrical Control Feeder Panel, 40A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input MCB (40Amp. FP), GFU with auxiliary contact for earth fault protection, 32Amp. AC-3 duty PMC based DC contactors (for DOL and APSC type),Microprocessorbased Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications,Heavy Duty terminal, connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and directionof Engineer-in-Charge. |
| 96 | Up to 5 HP (DOL typе) |
| 97 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MМССВ (ТР), GFU with auxiliary contact for earth fault protection, 32Amp. AC-3 duty PMC based DC contactors (For Star and Main), 40Amp. 1 Pole Contactor for APSC, 22Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. |
| 98 | Above 5 HP and up to 10 HP (Star Delta tyре) |
| 99 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MМССВ (TР), GFU with auxiliary contact for earth fault protection, 35Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 25Amp. Contactor for Delta, Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. |
| 100 | Above 10 HP and up to 15 HP (Star Delta type) |
| 101 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MМССВ (ТР), GFU with auxiliary contact for earth fault protection, 40Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 32Amp. Contactor for Delta, Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminalconnectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 7 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features requirelnatire N efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. |
| 102 | Above 15 HP and up to 20 HP (Star Delta type) |
| 103 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 125A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 125Amp. МССВ (TP), GFU with auxiliary contact for earth fault protection, 45 Amp. AC-3 duty PMС based DC contactors (For Star and Main), 50 Amp. 1 Pole Contactor for APSC, 40 Amp. Contactor for Delta, Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 8.3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. |
| 104 | Above 20 HP and up to 25 HP (Star Delta type) |
| 105 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 125A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 125Amp. MМССВ (ТР), GFU with auxiliary contact for earth fault protection, 63 Amp. AC-3 duty PMC based DC contactors (For Star and Main), 80 Amp. 1 Pole Contactor for APSC, 50 Amp. Contactor for Delta, Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 12.5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. |
| 106 | Above 25 HP and up to 30 HP (Star Delta type) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 daySep 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender