Housing Urban and Rular Development Local Bodies Closing in 12 days TDR #57442050

Tender For Construction Of Boys Hostel (Hostel No. 2) In Ccet, Sector-26, Chandigarh. (Composite Work)

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
23.77 Crore
Estimated cost
Bid Submission
28 Sep 2026
12 days left
EMD
33.77 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Boys Hostel (Hostel No. 2) In Ccet, Sector-26, Chandigarh. (Composite Work)

BOQ

Name of Work:- CONSTRUCTION OF BOYS HOSTEL (HOSTEL NO. 2) IN CCET, SECTOR-26, CHANDIGARH. (COMPOSITE WORK)
Sl. No. Item Description
1CIVIL WORKEARTHWORK Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. : All kinds of soil. (DSR- 2.6.1)
2Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (DSR- 2.25)
3Supplying and filling in plinth with local fine sand under floors, including watering, ramming, consolidating and dressing complete. (DSR- 2.27)
4CONCRETE Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR - 4.1)1:5:10 (1 cement: 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR- 4.1.10)
5Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. up to floor five level, excluding the cost of centering, shuttering and finishing : (DSR- 4.2)1 :5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). (DSR- 4.2.8)
6Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural source (DSR 4.10)
7Providing & applaying a coat of residual petrolium bitumen of grade of VG-10 of approved quality using 1.70kg per square meter on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil (DSR 4.13)
8Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. (DSR- 4.17)
9REINFORCED CEMENT CONCRETE WORK Centering and shuttering including strutting, propping etc. and removal of form for : (DSR - 5.9) Foundations, footings, bases of columns, etc. for mass concrete. (DSR-5.9.1)
10Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR- 5.9.2)
11Suspended floors, roofs, landings, balconies and access platform. (DSR- 5.9.3)
12Shelves (Cast in situ) (DSR- 5.9.4)
13Lintels, beams, plinth beams, girders, bressumers and cantilevers. (DSR- 5.9.5)
14Columns, Pillars, Piers, Abutments, Posts and Struts.: (DSR - 5.9.6)
15Stairs, (excluding landings) except spiral-staircases. : (DSR- 5.9.7)
16Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards. (DSR- 5.9.13)
17Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). : Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). (DSR- 5.11.1)
18Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level : Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR- 5.22.6)
19Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level : Thermo-Mechanically Treated bars of grade Fe-500D or more (DSR-5.22.6A)
20Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. (DSR-5.33)All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum (DSR-5.33.1.1)
21All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum (DSR-5.33.2.1)
22Add for using extra cement in the items of design mix over and above the specified cement content therein. (DSR-5.35)
23Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). : Floor Joint of 100 mm gap (DSR-5.44.1)
24Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self-centering arrangement that freely rotates I moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall conform to ASTM 6063). : Roof Joint of 100 mm gap (DSR-5.46.1)
25BRICK WORK Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.1.2)
26Extra for forming cavity 5 cm to 11.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 300 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design. (DSR-6.6)
27Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks). (DSR- 6.15)
28Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in : Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR- 6.32.1)
29Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). (DSR- 6.44)
30Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS : 12894, in super structure above plinth upto floor V level. : Cement mortar 1 : 4 (1 cement : 4 coarse sand) (DSR-6.45.2)
31Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. {The payment of RCC band and reinforcement shall be made for seperately). (DSR- 6.47)
32STONE WORK Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) upto plinth level with: Cement mortar 1 :6 (1 cement: 6 coarse sand) (DSR-7.1.1)
33Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1 :6: 12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1 :6 (1 cement: 6 coarse sand) (DSR-7.2.1)
34MARBLE & GRANITE WORK Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. : Granite stone slab of colour black, Cherry/Ruby red: Area of slab over 0.50 sqm (DSR-8.2.2.2)
35Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. : Granite work (DSR-8.3.2)
36Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR-8.5)
37Mirror polishing on marble work / Granite work / stone work where ever required to give high gloss finish complete. (DSR 8.6)
38Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. (DSR 8.15)
39Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (DSR-8.31)
40WOOD AND PVC WORKProviding wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). : Second class teak wood (DSR-9.1.1)
41Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick excluding ISI marked Stainless Steel butt hinges with necessary screws (DSR-9.21.1)
42Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). (DSR-9.23)
43Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1 :3:6 mix (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size). (DSR-9.53)
44Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300 x 16 mm (DSR-9.96.1)
45Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete: 200 x 10 mm (DSR-9.97.3)
46Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm (DSR-9.100.1)
47Providing and fixing aluminium hanging floor door stopers ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. : Twin Rubber Stopper (DSR-9.101.2)
48Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. : 1.0 mm thick (DSR-9.127.2)
49Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1. 70 mm for Series R 1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. : Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (ii) Sites with structure height more than 20m for all wind speeds (DSR-9.147)Fixed window/ ventilator with mullion / transom. : Using R3 series with frame (55 mm & above ) x (45 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 2.5 metre) (DSR-9.147.C2.3)
50Casement Window with Double Rebate Frame with one Side Hung Glazed Panel and one Side Hung wire mesh Panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles on both glazed and fly screen panel : Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm & above) x (65 mm & above) & fly screen sash (30 mm & above) x (55 mm & above) & metal grill (if required to be paid separately). (Height upto 1.8 metre) (DSR-9.147.E6.1)
51Casement Window with Double Rebate Frame with two Side Hung Glazed Panel and two Side Hung wire mesh Panel and Fixed Mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles on both glazed and fly screen panel. : Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm & above) x (65 mm & above) & fly screen sash (30 mm & above) x (55 mm & above) & mullion (55 mm & above) x (65 mm & above) & metal grill (if required to be paid separately). (Height upto 1.8 metre) (DSR-9.147.E7.1)
52Casement Door with Double Rebate Frame with one Side Hung Glazed Panel and one Side Hung wire mesh Panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides of glazed panel and zinc alloy (Zamak) powder coated handle along with multi-point locking system on one side of fly screen panel. : Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm & above) x (85 mm & above) & fly screen sash (55 mm & above) x (65 mm & above). (Height upto 2.5 metre). (DSR-9.147.F3.1)
53STEEL WORK Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2)
54Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR-10.28)
55FLOORING Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1 :4 (1 cement: 4 coarse sand). : Ordinary cement without any pigment (DSR-11.20.4)
56Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : (DSR-11.23)Raj Nagar plain (DSR-11.23.2)
57Udaipur green marble (DSR-11.23.5)
58Providing and laying vitrified floor tiles in different sizes thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. : Size of Tile 600x600 mm (DSR-11.41.2)
59Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (DSR-11.46.2)
60Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge : Size of Tile 600x600 mm (DSR- 11.48.2)
61Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. (DSR-11.50)
62Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (DSR-11.55.1)
63ROOFING Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (DSR-12.22)
64Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. : 110 mm diameter (DSR-12.41.2)
65Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR-12.42)Coupler : 110 mm (DSR-12.42.1.2)
66bend 87.5° : 110 mm bend (DSR-12.42.5.2)
67Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. (DSR-12.44)
68Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 0x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws@ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) DSR-12.45.1)
69Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main 'T' runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main 'T' at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. : GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. (DSR-12.52.1)
70Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance> 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1 :4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1 :1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. (DSR-12.55)
71FINISHING 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) (DSR-13.1.1)
7215 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) (DSR-13.2.2)
736 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand) (DSR-13.16.1)
74Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. (DSR-13.26)
75Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including priming coat with cement primer. (DSR-13.41.1)
76Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) (13.47.1)
77Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (DSR-13.62.1)
78Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR-13.80)
79TACTILE TILE Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. (DSR-16.90)
80ALUMINIUM WORK Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR-21.1.1.1)
81Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR-21.1.2.1)
82Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. : Pre-laminated particle board with decorative lamination on both sides (DSR-21.2.2)
83Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as perarchitectural drawings and direction of Engineer-in-charge complete. : Upto 5 mm depth and 5 mm width (DSR 21.8.1)
84WATER PROOFING Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement ompound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (DSR-22.5)
85Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry making pattern of 300x300 mm square 3 mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (DSR 22.7.1 )
86NON-SCHEDULED ITEMS Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Yellow Jaiselmer (NS Based on DSR-11.23)
87Providing and fixing 8mm thick wooden laminated floor class of use 31/23 having wear resistance level of AC-3 as per EN-13329 with a direct pressure laminate surface including profile, treated with aluminium side, flooring of approved colour and shade complete in all respects and to the entire satisfaction of the Engineer in charge.
88Granite Stone work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1 :3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1 :2 (1 white cement : 2 marble dust) with an admixture of pigment to match the granite shade (To be secured to the backing by means of cramps, which shall be paid for separately). : Granite stone slab of colour black, Cherry/Ruby red : Area of slab over 0.50 sqm (NS based on DSR 8.1.1.2)
89Providing and fixing 2'-0\\" deep cupboard /cabinet consisting of 19mm thick commercial board and 6mm thick ply on back side, 1 mm thick mica on the exposed surface and making shelves in cabinet. The rate further includes the cost of lipping, piano hinges, cupboard lock, screws, nails, 2 nos. fancy s.s. handles, 2 nos. magnetic catchers, fevicol and painting two coats over one priming coat and preparation of surface on board and ply surface complete in position as per entire satisfaction of Engineer-in-charge. (NS)
90Providing and fixing BRICKJALLI with class designation 7.5 bricks of size 22.86 cm x 11.43 cm thick alternate layers laid in cement sand mortar 1:4 using 58 number bricks per sqm, compete in all respects and to the entire satisfaction of Engineer-in-charge. (NS)
91Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. - 150mm diameter. (NS)
92Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing, leaving 10 mm gap for thermal expansion. (NS) Coupler : 150 mm
93bend 87.5° : 150 mm bend
94Providing and fixing Brick clading on wall with bricks of class designation 10 having size 9\\"x3\\"x2 1/4\\" of approved shade/sample by Engineer in charge, on outer wall, over 12mm thick cement mortar 1:3 (1 cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm. including scaffolding upto all height complete in all respect as per architectural drawing and to the entire satisfaction of Engineer-in-charge. (N.S)
95Providing and fixing DGU glass (6mm toughened + 12 mm argon gas +6mm toughened), (Make Saint gobain, Modi guard, AIS) as per specifications, drawings and direction of Engineer-in-charge complete.
96Providing and laying antiskid vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality with water absorption less than 0.08% and conforming to IS 15622, of approved make, in all colours and shades. The tiles are to be fixed with 3mm grove using spacers. The tiles are to be laid on 20mm thick bed of cement mortar 1:4 (1) cement: 4 coarse sand), jointing with grey cement slurry @3.3kg/sqm. The grove are to be filled with cementitous grout mix with proportion of 0.90kg grout and 0.10 kg of hardener for each kg of filling material. Antiskid floor vitrified tile of size 600x600mm
97PUBLIC HEALTH SERVICES Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.d DSR 2.8 DSR2.8. All kinds of soil. DSR 2.8.1
98Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : DSR 2.10. DSR2.10.All kinds of soil. DSR 2.10.1 . Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. DSR 2.10.1.2
99Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : DSR 4.1 . 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 4.1.3
100. 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) DSR 4.1.11
101Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR5.3
102Centering and shuttering including strutting, propping etc. and removal of form for : DSR5.9 . Suspended floors, roofs, landings, balconies and access platform DSR5.9.3
103Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. DSR 5.22 . Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 5.22.6
104Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: DSR 6.1 . Cement Mortar 1:4 (1 cement :4 coarse sand) DSR6.1.1
105Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. DSR10.25 . In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25.2
10612 mm cement plaster finished with a floating coat of neat cement of mix : DSR13.7 . 1:3 (1 cement : 3 fine sand) DSR 13.7.1
107Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
108Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
109Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china dual flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : DSR 17.3 . W.C. pan with ISI marked white solid plastic seat and lid.DSR 17.3.1
11012. Providing and fixing wash basin with CI Bracket, 15mm dia CP Brass single hole Basin mixture of appd quality and make including ainting of fittings and brackets , cutting and making good the wall where ever required DSR 17.7 White Vitreous china wash basin size 550x400 with 15mm CP Brass Single whole Basin Mixture DSR 17.7A DSR17.7A
111Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board610x460 mm bowl depth 200 mm
112Providing and fixing white vitreous china water closet squatting pan (Indian type) :Orissa pattern W.C. pan of size 580x440 mm
113Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.10 litre (full flush) capacity-white
114Providing & fixing 8mm dia CP/ SS Jet with flexible tube upto 1mtr long with SS triangular plate to European WC of quality and make as appd by EIC DSR 17.16.A DSR17.16.A
115.Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. DSR 17.28 . Flexible pipe DSR17.28.2 40 mm dia DSR17.28.2.2
116Providing and fixing toilet paper holder C.P. brass
117.Providing and fixing soil, waste and vent pipes : DSR17.35 100 mm dia. DSR17.35.1. Centrifugally cast (spun) iron socketed pipe as per IS: 3989. DSR17.35.1.2
118Providing and fixing heel rest sanitary bend DSR17.40.. 100 mm dia DSR17.40.1. Centrifugally cast iron S&S as per IS: 3989. DSR17.40.1.2
119Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.. 100x100x100 mm DSR17.43.1. Centrifugally cast iron S&S as per IS: 3989. DSR17.43.1.2
12017. Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : DSR17.55. 100 mm DSR17.55.1. Centrifugally cast iron S&S as per IS: 3989. DSR17.55.1.2
121Providing and fixing terminal guard: DSR17.56. 100 mm DSR17.56.1. Centrifugally cast iron S&S as per IS: 3989. DSR17.56.1.2
122Providing and fixing collar: DSR17.57. 100 mm DSR17.57.1. Centrifugally cast iron S&S as per IS: 3989. DSR17.57.1.2
123Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : DSR17.59. 100 mm DSR17.59.1
124Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : DSR17.60..100 mm inlet and 100 mm outlet DSR17.60.1. Centrifugally cast iron S&S as per IS: 3989. DSR17.60.1.1
125Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc DSR18.1. Internal work - Exposed on wall DSR. 20 mm dia nominal bore DSR18.10.2
126. 25 mm dia nominal bore DSR18.10.3
127. 32 mm dia nominal bore DSR18.10.4
12824. Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : DSR18.11. 15 mm dia nominal bore DSR18.11.1
129. 20 mm dia nominal bore DSR18.11.2
130Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed end)20 mm
13125 mm
13232 mm
133Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : DSR18.18. 20 mm nominal bore DSR18.18.2
134Providing and fixing uplasticised PVC connection pipe with brass unions : DSR18.21. 45 cm length DSR18.21.2. 15 mm nominal bore DSR18.21.2.1
135Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :20 mm diameter pipe
13625 mm diameter pipe
13732 mm diameter pipe
138Providing and fixing of GI union in GI pipe including cutting and threading the pipe and making long screws etc complete (new work)20 mm
13925 mm
14032 mm
141Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. DSR18.48
142Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : DSR18.49. 15 mm nominal bore DSR18.49.1
143Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. DSR18.51. 15 mm nominal bore DSR18.51.1
144Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore.
145.Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 DSR18.53 15mm nominal bore DSR18.53.1
146Providing and fixing CP Brass Extension Nipple Size 15x50mm of appd make and quality as per direction of the Engineer In Charge DSR18.53A
147Cutting holes up to 30x30 cm in walls including making good the same: DSR18.76. With F.P.S. bricks DSR18.76.1
148Cutting holes up to 15x15cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. DSR18.77
149. Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : DSR19.1100 mm diameter DSR19.1.1
150. 200 mm diameter DSR19.1.3
151Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : DSR 19.2100 mm diameter S.W. Pipe DSR 19.2.1
152200 mm diameter S.W. pipe DSR 19.2.3
153Providing and fixing square-mouth C I gully trap complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :. 150 x 100 mm size P type.
154Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality DSR 19.19 DSR19.19. H D - 20 DSR 19.19.3 . Circular shape 560 mm internal diameter DSR 19.19.3.1
155Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter
156Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: DSR 19.30 . Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : DSR 19.30.3 DSR19.30.3With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR 19.30.3.1
157Extra for depth beyond 45 cm of brick masonry chamberFor 600x850 mm sizeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
158Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. DSR 22.5
159Providing and fixing of CP Brass/SS Towel Rail 600mm of with screws etc. to the satsifaction of EIC of approved make Jal Model No. 36520 Warna or equialent Model of CERA /Kerovit/ ESSCO
160Providing and fixing of CP Brass/SS Towel Ring with screws etc. to the satsifaction of EIC of approved make Jal Model No. 36524 Warna or equialent Model of CERA /Kerovit/ ESSCO
161Providing and fixing of CP Brass/SS/ABS Soap Tray made of Plastic including glass bowl of approved make Jal Model No. 36540 or equialent Model of CERA /Kerovit/ ESSCO
162Prov. & fixing of looking mirror of size 450x600mm made with 5mm thick (minimum) superior quality glass including cost of hard board, PVC beading and C.P. Screw etc. to satisfaction of EIC of approved make
163.Providing drip seal joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm
164Construction of Curb consisting of cement concrete 1:2:4 including cost of C.P. hinged grating and cost of sand bajri etc.
165Providing and fixing of HCI P trap 4\\" dia complete in all respect.
166Providing & fixing of C.P 1'-4\\" long 32mm bend as per approved make complete in all respect.
167Providing and fixing of Chinaware Half stall Urinal with fittings, standard size C.P. brass flush pipe, spreaders and clamps all in C.P. brass complete in all respect Cat No. S4020112 Make M-cera size 375x390x590mm
168Providing and fixing of white vitreous chinaware urinal partitions of size 90x320x720 mm complete in all respect Make M-cera S4090101
169Providing and fixing of 32 mm SS grab Rail with cutting ,welding, fixing at site with fastner, cup, complete in all respect.
170Providing and fixing Tank Nipple complete in all respect20 mm dia
17125 mm dia
17232 mm dia
173Supplying and Installation of 400 Ltrs Capacity Drinking Water Cooler having (+10%) following specification, full body stainless steel SS 304, ISI marked of approved make Storage Capacity: 400 LtrsCooling Capacity: 150 LPH Tank Material: SS 304, Body SS BIS Approval IS 1475 Make Blue Star/Voltas/Climatrol approved by BIS
174P/F of automatic Line voltage corrector of 4 KVA ( Step type) for domestic use copper wound complete with volt meter and ampere meter, MCB, Copper bindingsilicon core with 3 steps complete with time delay relays/ controls power coated body of 22 gauge with wire 2.0 meter complete in all respects to the entire satisfaction in all respects to the entire satisfaction of the EIC. Make: Deol, V-gaurd, Luminous
175Supplying & Fixing of Water Purifier with 3 Stage Purification system consisting of sediment filter, Activated Carbon Filter and Ultravoilet treatment having purification capacity of 200 LPH, water control sensor for automatic control of purifier as per level of water cooler and valve for back flushing of sediment filter complete of make Usha, Kent, Blue Star or equivalent to the satisfaction of EIC
176Manufacturing, Supplying and fixing of Rain Shelter for Pneumatic Pump / Monoblock Pump made from MS Angle covered with Fibre Sheet including grouting complete to the satisfaction of EICFor Boosting Pump
177Providing , Installing, Testing, Commissoing of mono block pumping 2 HP set of follwing para metre including starter piping connections & other allied works complete in all respect. Of make Kirlosker/ ABB/ Crompton graves.Head 30Mtr Discharge 1.97 LPS RPM 2830 of approved make
178Providing and fixing of 3 core 2.5 sq.mm Multicore flexible cable PVC Insulated and Sheathed with Bare Copper Conductor as per IS 694 marked complete including making connection to the satisfaction of EIC Make : Havells, Polycab, Finolex or as per approved make list
179Providing and fixing Water Heaters Volume 50 Ltr. Approved Make Bajaj,Cera,Racold horizontal ( Manual) Complete in all respect of approved make
180Providing and Fixing Chinaware Counter Top Basin 600 x 400 x 160 make Jaquar / CERA / Kerovit / Hindware
181Providing and fixing of C.P. Steel Grating Heavy (With hole without hole) 100 mm dia, of approved make
182Providing and fixing of CP Brass/SS/ABS overhead shower with swiveling Joint , 125mm dia (min) with C.P Brass/ S.S Shower Arm and flange to the satsifaction of EIC of approved make ESSCO Model No. 536A & 542A or equialent Model of CERA /Kerovit/ Jal
183Providing and installation of Elect. Control Panel with star delta connection suitable for operation of 2 HP submersible motor made out of MS base compring of contract plat on off Switch complete in all respect as per site requirement.
184Providing and laying of UPVC pipe, IS-4985 marked, Pressure 6 kg/cm2 including cutting, joining, solvent and all necessary fittings complete in all respect except excavation.100mm i/d
185Provding and fixing c.p (brass) Centre Hole Mixer make Jaquar CAT No. 167KNB or as per approved make list
186RAIN WATER HARVESTING SYSTEM AND STORM WATER DRAINAGE CONSTRUCTION OF TRENCH OF SIZE 4.59 X 3.73 METRE Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil
187Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.All kinds of soilDepth exceeding 1.5m but not exceeding 3.00m BGL
188Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
189Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
190Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
191Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
192Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
193Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete.
194Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
195Suspended floors, roofs, landings, balconies and access platform.
196Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars.
197Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.MS ladder made of angle iron 50x50x6mm approx 12'6\\" length
198Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality H D - 20Circular shape 560 mm internal diameter
199Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
200Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
201Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
202DRILLING OF T/WELL FOR INJECTION WELL UPTO 100.00M BGLBoring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil400 mm dia.
203Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 400 mm dia.
204Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 200 mm nominal size dia.
205Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 200 mm nominal size dia.
206Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
207Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
208Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
209Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm dia
210Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
211Suppling and fixing MS centring guides complete in all respect as per direction of the Engineer in charge.
212Electric logging after drilling of tubewell for feasibility of installation of blind pipe and slotted pipe in bore by analysing the N-16, N-64 and S.P.-Log. The complete bore log should be submitted in triplicate.
213LAYING OF RCC NP-2 PIPE, COLLECTION CHAMBERS AND MANHOLES ETC. Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil
214Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
215Pipes, cables etc. exceeding450 mm dia. but not exceeding 600 mm dia.
216Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
2171:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
218Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
219Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform.
220Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars.
221Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
22212 mm cement plaster finished with a floating coat of neat cement of mix1:3 (1 cement: 3 fine sand)
223Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia. R.C.C. pipe
224300 mm dia. R.C.C. pipe
225450 mm dia. R.C.C. pipe
226Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Square shape 450mm internal dimension
227H D - 20 Circular shape 560 mm internal diameter
228Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50metres lead as per direction of Engineer-in-charge : bituminous road
229proving and fixing of precast RCC Road gully cover with frame having size 600mmx450mm complete in all respacts
230FIRE FIGHTING SYSTEM Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. (DSR 18.10.6) 50MM DIA
231Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : (DSR 18.46.6) 50mm i/d
232Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
233(A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520© Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (D) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (E) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head
234Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of Post office Red complete as required : 80mm dia
235100mm dia
236Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain as required : Single headed Stainless steel
237Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100mm dia
238Providing, installation, testing and commissioning of Dual plat non-return valve/Check valve of following sizes with rubber gasket, GI bolts, nuts, washers etc.as required : 100mm dia
239Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)
240Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 mtr long
241Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)
242Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way - 100 mm dia M.S. Pipe
243Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
244Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
245Supplying, installing, testing and commissioning of Copper Conductor Cables, XLPE Insulated, unarmoured IS 7098 (Part 1) marked of approved make Havells, Finolex, Polycab to the satisfaction of EIC 2C x 1.5 Sqmm
2463C x 2.5 Sqmm
247Supply, Installation, Testing and Commissioning of 100 mm dia Bourden type, Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2
248Providing and fixing of HOSE CABINET of Size: (600mm x 600mm x 450mm) made of 16 gauge MS sheet with 4mmthick glazed glass door i/c necessary locking arrangement suitable to accommodate 15 mtr. long hose reel pipe & branch pipe mounted on wall or raised bric platform & duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respect as required. Make: Newage/ Minimax/ Omex/ Safeguard.
249Supply, installation, testing and commissioning of ISI marked (IS:15638) portable fire extinguisher, ABC (gas pressure) type capacity 4kg with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets as required as per specifications.
250Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed. 4.5kg capacity cylinder
251Supplying and installing of 3nos set of fire buckets of 24 gauge galvanized steel sheet, standard 9 liter capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters \\"Fire \\" in black and gold.
252Providing and fixing in position automatic brass ball valve in tanks With brass ball Cock with plastic ball 50 mm
253Providing and fixing in position G.I tank nipple of approved make G.I tank nipple 50mm i/d
254Manufacturing, Supplying and fixing of Rain Shelter for Pneumatic Pump / Monoblock Pump made from MS Angle covered with Fibre Sheet including grouting complete to the satisfaction of EIC
255Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
256PROVISION OF ELECTRICAL INSTALLATION WORK :DSR Item No. 1.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A
257DSR Item No. 1.29 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.
258DSR Item No. 1.30 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
259DSR Item No 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.i. 3 x 1.5 sq. mm
2603 x 2.5 sq. mm
261DSR Item No. 1.20 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of Surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. i. 20 mm
26225 mm
263DSR Item No.5.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
264DSR item No.5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
265DSR item No.1.4 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
266DSR Item No.1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
267DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.i. Single pole
268Triple pole
269Triple pole and neutral
270DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator).8 way (4 + 24) Double door
271DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required100 A,30KA,FPMCCB
272125 A,36KA,FPMCCB
273400 A,50KA,FPMCCB
274DSR item no.8.9LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 Hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver& electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 18- 22 watt
27536 watt
276Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making good the damage, Carriage Charges, connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge.Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 300-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only.
277Size 15” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 380-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only.
278DSR item no. 8.7.10 LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver& electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)36 watt
279DSR item No.9.2.4 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
2801400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum)
281Supply and Erection of B.L. Holder of make Anchor Panta / Havells Reo/ Gold Medal Essenza ISI marked on existing Jn. Box / Wooden block including making connection etc. as required.
282S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA / PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen and the driver of the fitting should be workable on 140-260 Volt. The colour temperature of LED should be minimum 5600 degree Kelvin. The LED Bulk Head fitting should be of Philips / Wipro / Bajaj /Crompton / Havells /Panasonic/ Twinkle/ K-Lite/ Trilux/ Jaquar make only. The fitting should be of IP-65/66. The LED should have a life of 50000 burning Hours. The fitting should have THD<15% and power factor 0.9 or above. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer In Charge.
283S/I/T/C of LED Highbay luminaries of Philips/ Wipro/ Bajaj/ LT/ Jaquar/ Havells/ Crompton/ Panasonic/ Keselec/ Surya make only. The job includes the cost of testing, commissioning and making connection with 3x1.5 sq. mm. copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer In Charge. Specification of LED fittings: Wattage of LED fittings As per following parameter.Total lumens of the LED fittings Minimum 9600 lumen Body of fitting Pressure dia cast aluminium body with Extruded Aluminium heat sinkOperating voltage 140 V to 270 V, AC supply or better.Input frequency 50 Hz + 1 Hz Power factor Minimum 0.95 Luminaire efficacy Minimum 120 lm/w Color rendering index CRI shall be greater than 80 Working/ operating temperature 00 to + 450c or better Color temperature 56000K to 60000KElectronic DriverDrive current (LED) As per OEM.Operating voltage 140 V to 270 V AC supply or betterType of driver Constant current output driver THD Less than 10%Surge Protection 10 KV minimum Efficiency Driver >85%Protection Shall have under voltage and over voltage protection.Guarantee/ Warrenty of 5 years against manufacturing defect. LED fittings including LED driver Fixture Should comply with LM 79 test from NABL/UL lab. LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA / Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. Life of LED 50000 burning hours at 70% lumen maintenance
284Supply and Erection of LED Post Top Lantern fittings made of cast aluminium housing with power to be mounted on directly on inbuilt Heat sinks. A UV stabilized PC/PMMA diffuser is provided for Glare Free Lighting with high visual comfort to complete with Electronic LED Driver Power supply & related accessories with the following specifications to be installed on existing pole. The fitting should be of Twinkle make Ruby LUX-MAX PT-151-L (40W)/ Wipro make LP-05-501-XXX-30-G1(45W)/ Bajaj make BGCPNP 45W LED WH/ Jaquar make OGL-GRY-LGTP07X040XW its equivalent model of Crompton/ Homdec/ Lustre/ Philips/ Mayfair/ make only (with subject to the condition of approval of EIC of Work). The sample to be got approved before installation. Specifications of LED fittings:Ingress Protection Level of fittingIP 65 or betterBody of fittingPressure Die cast aluminium with poly methyl methacrylate (PMM) diffuserEfficacyGreater than 90 Lumens per wattOperating Voltage140 V to 270 V, AC supply or betterInput Frequency50 Hz + 1HzPower FactorMinimum 0.95Working /Operating Temperature00 C to + 450 C or betterColour Temperature56000 K to 60000 KElectronic Driver Driver CurrentConstant current less than 600 MAOperating Voltage140 V to 270 V, AC supply or betterTHDLess than 10%Surge protection10 KV minimumEfficiency≥ 85%Make of DriverShould of same make of luminaries.ProtectionShall have under voltage and over voltage protectionGuaranty of LED fitting including LED driver.5 Years against manufacturing defectLED Type/ Make/ ModelPower CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance Complying with LM80 Test report from the original manufacturer.Life of luminaries50000 burning hours
285DSR item no.8.16.4 LED Flood powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying,installation,Testing&CommissioningofFlood Light,powdercoatedpressuredie cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC, freq50/60hz,Operatingtemprange-5degto50deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driverefficiency>85%,THD<10%asperIEC 61000-3-2,P.F.≥0.95,IP-66,IK-10,CRI>70,undervoltage andovervoltageprotection, EMI-EMC asperCISPR-15,lenses for beam angle 30 deg-120deg as per the application andthe project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extra polation IES TM-21-11 report, CCT 3000°K / 4000°K/5700°K/6500°K(AsperANSIBin), SDCM (Standard Deviation Color Matching)<5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sqmm FRLS/ HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.Systemlumenefficacy≥120and<135 lm/Watt output.LM79&LM80Testreport andalltestingrequiredfor LEDfixturesasperBIS shallbesubmitted.Shapesizeand CCTshallbeasapprovedbyEngineer-in-Chargeasper requirement. (Thermalmanagement:heatsinkofaluminium housingsuchthatLEDjunctiontemperatureshallnotriseabove 90°C). 150 Watt
286S/I/T/C of Circular Hanging type surface mountain LED fitting. The fitting should have dia of 600 mm to 800 mm with integral driver to be installed on existing ceiling with the help of fastener, screws etc. The fitting should be make Wipro LM230-821-XX57-XW/ Havells make MONDO600RDP/ S36W LED 830SPSWH/ Crompton make LCSUR4-36-CDL or its equivalent model of Philips/ Bajaj/ LT/ Jaquar/ Panasonic/ Surya only. The job includes the cost of testing, commissioning and making connection with 3x1.5 sq. mm. copper wire from adjacent light point, other petty material and labour etc. as required to complete the job to the entire satisfaction of Engineer In Charge.Specification of LED fittings:A.Wattage of LED fittingsAs per following parametersB.Total lumens of the LED fittingsMinimum 3000 lumenDBody of fittingsCRCA steel sheet with opal acrylic diffuser/ Extruded al. Housing CRCA front frame opal diffuser/ CRCA power coated housing with high efficiency translucent diffuser.EOperating voltage140 V to 270 V, AC supply or better.FInput frequency50 Hz + 1 HzGPower factorMinimum 0.95HLuminaire efficacy100 lm/w (minimum)IColor rendering indexCRI shall be 80 (minimum)JWorking/ operating temperature00 to + 450c or betterKColor temperature56000K to 65000KLElectronic Driver i)Drive current (LED)As per OEM.ii)Operating voltage140 V to 270 V AC supply or betteriii)Type of driverConstant current output driveriv)THDLess than 10%v)Surge Protection2.5 KV minimumvi)Efficiency Driver>85%vii)ProtectionShall have under voltage and over voltage protection.M.Guarantee of LED fittings including LED driver5 years against manufacturing defect.N.FixtureShould comply with LM 79 test from NABL/UL lab.O.LED Type/ Make/ ModelPower CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hour’s @70% lumen maintenance complying with LM 80 test report from the manufacturer.PLife of LED50000 burning hours at 70% lumen maintenance
287S/E of steel pole made out of galvanized mild steel tubes having 114 mm dia at bottom and 60/75 mm dia at top with cast alum. Embellishments. The poles are primer coated and painted with polyurethane paint of 4 Mtr. Height of Twinkle make LUXMAX-SP-114-401/ May fair MFMD-109 or its equivalent make Bajaj/ K-LITE/ HOMDEC/ Valmont only. The cost including the cost of foundation with ratio cement, sand, bajri mixture 1:2:4 and foundation shall be provided with 4 Nos. ‘L’ type nuts/ bolts made out of 16 mm dia M.S. rod having threads upto whole length, the total length of the bolt will be 500 mm including ‘L’ shape. The cost including nuts and washer etc. The foundation shall be laid as per the drawing attached to complete the job. The foundation will be provided with 2 Nos. DWC pipe 50 mm for outgoing & incoming cables. The total length of the pipe will be at least 1 Mtr each. The foundation will be constructed upto plinth level & finished at same level. The job including carriage charges of material & completion the job to the entire satisfaction of Engineer in Charge.
288DSR item No.8.1.5 LED Down lighter (SMD Type) (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver& electrical circuitary), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim. 22 watt
289Supply and erection of 400 Amp. 415 Volt. 4 pole ON Load Change over switch with MS enclosure of following ratings installed in existing switch board/ LT Panel with nuts & bolts of requisite size after making holes etc. The job includes cost of making inter connection with suitable rating copper wire / copper strip with dowels, lugs & thimbles duly crimped, bonding to existing earth and carriage, testing & commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. Make: L&T/ Havells/ ABB/ HPL/ Hager only.
290Supply, erection testing and commissioning of L.T. Cubical panel indoor type with degree of protection IP–54 fabricated from 14 GMS (2mm) thick CRCA sheet and MS flat of suitable size (horizontal/vertical construction) in single piece for single supply respectively having separate fully compartment aliased and front side openable doors for each switch/BBC etc. Each door would be vermin dust proof. The panel shall have air dissipation design (slotted). The panel should be nicely painted with powder coated superior quality paint after degreasing and phosphate treatment. The panel should be marked with the incoming and outgoing feeder. The panel is to be installed on the wall at site with the help of suitable size fasteners by making suitable arrangements and should be bonded to existing earth with the help of spring washers thimbles etc. to secure firm contact. The job includes main interconnections (duly tape) with solid aluminium. bars of requisite cross section capable of taking full load current between each SFU’s / MCCB’s / contactors / MCBDP’s and bus bar. All the incoming and outgoing connection should be made at the front as per site requirement. The cubical panel should have removable gland plates for incoming and outgoing cables duly crimped with dowels lugs/thimbles and provided with PVC tape at each end. The bus bar should be supported on epoxy insulator of suitable length conforming to relevant Indian standard (CPRI) and sufficiently robust to effectively with stand Electro mechanical stresses produced in the event of short circuit. The job includes all material labor carriage of panel to the site testing and commissioning as required to complete the job as per drawing of the panel to the satisfaction of the Engineer in charge. The job include making connection of the outgoing cable with lugs/thimbles duly crimped and making connection with the incoming existing O/H bus trunking or cable as per site requirement. The panel should be upto 1000 mm deep as required at site. The LT panel should have provision of following switchgear and cost of bus bar. BUS BAR: S/E of 1 No.400 Amp. 415 volts 3 phase Bus Bar consisting of 4 Nos. High conductivity electrolytic quality Aluminum bars conforming to relevant IS (each of equal cross sections) of requisite size for a current density of 1 Amp per sq.mm. The bus bar shall be supported on epoxy insulators as per CPRI specifications & should be long enough to accommodate all the switches. The job includes cost of inter connections from the Bus bar to each ACB/ MCCBs in the existing panel by means of solid high conductivity electrolytic Al. strips (current density 1 Amp per square mm) of requisite size capable of carrying full load current. Each connection through bus bar shall be made with nuts & bolts and tightened firmly with washers. The bus bars shall be covered with PVC heat shrinkable sleeves of different colours by suitably heating with Hot gun.INCOMING. S/E of Digital Multifunction meter of Class-0.5 Accuracy (Make: Schneider / ABB / Siemens / L&T). Qty. = 01 No.Space for 1 No. 400 Amp. 415 V 4 pole MCCBOUTGOING:Space for 05 Nos. 100/125 amp. MCCBs Space for 01 No. 400 amp. Chang over switch Space for 24 Nos. MCB SP and 01 No. MCB TPN01 No. LT Panel approx. size 1750 mm x 1200 mm
291Supply, erection testing and commissioning of L.T. Cubical panel indoor type with degree of protection IP–54 fabricated from 14 GMS (2mm) thick CRCA sheet and MS flat of suitable size (horizontal/vertical construction) in single piece for single supply respectively having separate fully compartment aliased and front side openable doors for each switch/BBC etc. Each door would be vermin dust proof. The panel shall have air dissipation design (slotted). The panel should be nicely painted with powder coated superior quality paint after degreasing and phosphate treatment. The panel should be marked with the incoming and outgoing feeder. The panel is to be installed on the wall at site with the help of suitable size fasteners by making suitable arrangements and should be bonded to existing earth with the help of spring washers thimbles etc. to secure firm contact. The job includes main interconnections (duly tape) with solid aluminium. bars of requisite cross section capable of taking full load current between each SFU’s / MCCB’s / contactors / MCBDP’s and bus bar. All the incoming and outgoing connection should be made at the front as per site requirement. The cubical panel should have removable gland plates for incoming and outgoing cables duly crimped with dowels lugs/thimbles and provided with PVC tape at each end. The bus bar should be supported on epoxy insulator of suitable length conforming to relevant Indian standard (CPRI) and sufficiently robust to effectively with stand Electro mechanical stresses produced in the event of short circuit. The job includes all material labor carriage of panel to the site testing and commissioning as required to complete the job as per drawing of the panel to the satisfaction of the Engineer in charge. The job include making connection of the outgoing cable with lugs/thimbles duly crimped and making connection with the incoming existing O/H bus trunking or cable as per site requirement. The panel should be upto 1000 mm deep as required at site. The LT panel should have provision of following switchgear and cost of bus bar.BUS BAR:S/E of 1 No.200 Amp. 415 volts 3 phase Bus Bar consisting of 4 Nos. High conductivity electrolytic quality Aluminum bars conforming to relevant IS (each of equal cross sections) of requisite size for a current density of 1 Amp per sq.mm. The bus bar shall be supported on epoxy insulators as per CPRI specifications & should be long enough to accommodate all the switches. The job includes cost of inter connections from the Bus bar to each ACB/ MCCBs in the existing panel by means of solid high conductivity electrolytic Al. strips (current density 1 Amp per square mm) of requisite size capable of carrying full load current. Each connection through bus bar shall be made with nuts & bolts and tightened firmly with washers. The bus bars shall be covered with PVC heat shrinkable sleeves of different colours by suitably heating with Hot gun.INCOMING.S/E of Digital Multifunction meter of Class-0.5 Accuracy (Make: Schneider / ABB / Siemens / L&T). Qty. = 01 No.Space for 1 No. 125 Amp. 415 V 4 pole MCCBOUTGOING:Space for 04 Nos. 100 amp. MCCBs Space for 24 Nos. MCB SP and 01 No. MCB TPN01 No. LT Panel approx. size 1250 mm x 1200 mm
292DSR Item No.2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required).8way(4+24),Double door
29312way(4+36),Doubledoor
294S/I/T/C of linear suspended luminaire 4 ft. long made up of extruded aluminium with PMMA diffuser for standalone and seamless end to end connectivity. The fitting is to be installed on existing surface with the help of 2 no. suitable length universal suspensions suitable for quick on site adjustment. The fitting should be of Philips / Wipro / Bajaj / Trilux / Jaquar/ Havells/ Crompton/ Panasonic/ LT/ Surya make only. The job includes carriage, erection, making connections with 3x1.5 sq.mm copper wire from adjacent light point, testing and commissioning of the fittings and all the petty material as required to complete the same to the entire satisfaction of Engineer-in-charge. Specification of LED fittings:A.Wattage of LED fittings As per following parameter.B.Total lumens of the LED fittings Minimum 4000 lumen DDiffuser Extrusion Aluminium heat sink with Polycarbonate diffuserEOperating voltage 140 V to 270 V, AC supply or better.FInput frequency 50 Hz + 1 Hz GPower factor Minimum 0.95 HLuminaire efficacy >100 lm/wIColour rendering indexCRI shall be 80 (minimum)JWorking/ operating temperature 00 to + 450c or better KColour temperature 56000K to 60000KLElectronic Driver i)Drive current (LED)As per OEM.ii)Operating voltage 140 V to 270 V AC supply or betteriii)Type of driver Constant current output driveriv)THD Less than 10%v)Surge Protection 3 KV minimumvi)Efficiency Driver>85%vii)ProtectionShall have under voltage and over voltage protection.M.Guarranty of LED fittings including LED driver 5 years against manufacturing defect. N.Fixture Should comply with LM 79 test from NABL/UL lab.O.LED Type/ Make/ ModelPower CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. PLife of LED50000 burning hours at 70% lumen maintenance
295DSR Item No.1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4X6sq.mm+2X6sq.mmearthwire
2964X16sq.mm+2X6sq.mmearthwire
297DSR item No.15.16 Supplying and laying of following size DWC HDPE pipe ISI marked alongwith all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc.,complete as required .63 mm dia (OD-63 mm & ID-51 mm nominal)
29890mmdia(OD-90mm&ID-76mmnominal)
299160mmdia(OD-160mm&ID-135mmnominal)
300Supply and laying of XLPE insulated PVC sheathed Aluminum conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing RCC/Hume/DWC/ Metal pipe. The job include the cost of making connections with suitable size of Aluminium Lugs/ thimbles, testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer In Charge. The cable should be of Polycab/ KEI/ RPG/ Unistar (Universal)/ Havells/ Finolex/ R.R. Kabelmake only. Size 10 Sq.mm 4 Core XLPE Al. Arm. Cond. Cable
301Size 35 Sq.mm 3.5 Core XLPE Al. Arm. Cond. Cable
302Size 185 Sq.mm 3.5 Core XLPE Al. Arm. Cond. Cable
303Supply and laying of XLPE insulated PVC sheathed Aluminium conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid direct on surface with the help of M.S. clamp of suitable thickness. The job include the cost of making connections with suitable size of Al. Lugs / thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. The cable should be of Polycab/ KEI/ RPG/ Unistar (Universal)/ Havells/ Finolex/ R.R. Kabelmake only. Size 10 Sq.mm 4 Core XLPE Al. Arm. Cond. Cable
304S/E of M.S. bracket (‘F’ shape) made from 40mmx40mmx 5mm thick angle iron to be installed on existing parapet / wall with the help of suitable size of nuts, bolts and 1 No. 40mmx5mm MS strip of size approx. 1 feet long should be welded at the end of MS bracket for erection of existing LED flood light fitting. The job includes cost of painting of bracket with superior quality of paint and other all petty material etc. as required to complete the job.
305S/E of Thermo Plastic cable Jn. Box IP55/65 of size 200x160x98 deep (approximate) with 4 nos. thermal block suitable for 1 no. incoming and 3 nos. outgoing cables. The terminal block shall be of Hansel/ Wago/ Elmax/ Siemens make only and cable junction box shall be of Hansel make KF-1616-G or its equivalent Clipsal/ Legrand/ Rittal make only. The job includes all labour and petty material to required complete the job to the entire satisfaction of the Engineer in Charge of work.
306Supply and erection of M.S. box for Computer Point of size 10”x8”x3”deep made out of 16 G.M.S. sheet erected in existing wall and covered with 3mm thick white glazed bakelite sheet with provision of Piano type 4 Nos. 5 Amp. Socket with control switch of each socket. The job includes the cost of making interconnections with suitable copper wires painting of box with approved paint and other petty material required to complete the job as per satisfaction of Engineer-in-Charge at site.
307PROVISION OF LIFTSupplying, Installation, Testing & Commissioning of following capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003,BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including allother equipment and accessories complete asrequired :-Note:- Hoist way available at site: 2500mm(W) x 2100mm(D) as per drawing.Speed- 1MPSFloors- 3 (G+2)Travel -9 Meters (approx.)Stops&opening: 3stopsand 3openingsController: A.C. variable voltage & variable frequencyAutomatic rescue device (ARD) completewith dry maintenance free batteries as required.Operation: Microprocessor based single automatic push button/simplex selective collective/ duplex collective selective with/without attendantPower-415 Volts+10%, 3 phase, 50 Hz, 4 wires systemCar Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LEDfitting.The car flooring should be smooth and antiskidas approved by engineer-in-charge.Typeofdoors:-Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish).Landing doors:stainless steel scratchproof.A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car &Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4MP IP camera, suitable NVR andHDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder.The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency.An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness.In case of failure of ARD or other electronic devices, a provision of manual rescue be provided13 passenger (884kg)
308Provision of CCTVDSR item No.40.6.25/6MPIPIRBullet CameraSupplying Installation Testing and Commissioning of 5/6MP IP IR Bullet Camera having following spcifications and features etc :-Type of Camera: Bullet CameraImage Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night conditionSignal System: PAL/NTSCMinimum Illumination: 0.006Lux@ F1.4, AGC ON, 0 lux with IR or betterImaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.Signal to Noise Ratio: > 50 dBLens Type & Focus: 3.6mm/6mm fixed lens (optional as per site requirement)Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR and 30 Mtrs for colour view in night.Video Compression (Minimum): H.265 or better, H.265, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723Wide Dynamic Range: WDR (120dB or more)Digital Noise Reduction: DNR (2D/3D) On/OffStreaming: Triple streaming, configurableVideo Streaming & Frame Rates: Triple streaming, configurable Main stream: 5/6MP @25/30 fps, Sub streams: D1@25/30 fps or betterImage Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browserProfile Management: User configuration import, exportSecurity: User Authentication, Digital Water MarkingOnboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.Recording Management: Format SD, overwrite, storage management, video to NAS device,Edge Analytics: Tripwire, Intrusion, Motion DetectionAlarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detectionAlarm Support: It should have 1/1 Alarm In/ Out PortAudio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A / G.711Mu/ AAC/ G.726 audio compreesionNetwork Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,System Capability: ONVIFVMS: Camera shall support open source VMSCyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, , video encryption, IP/MAC filtering, HTTPS, trusted upgrade.Ethernet: 1 RJ 45 10/100 Ethernet portPower Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source.Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoEEnclosure: IP67 weather proof, IK10Operating Condition: Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)IR life: 40000 hours or higherVideo Bit rate: 32 KBPS - 8 MBPS or betterStandards: BIS with ER, STQC Certified, CE, FCC and RoHS5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor Bullet Camera.
309DSR Item No. 40.10.2Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below :1. Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth.2. NVR should support H.265 or better, H.264, MJPEG,MPEG4 support3. Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk.4. Intelligent auto power on when power resumes after power outage.5. Storage: It should support minimum 2 SATA Slots with 16TB capacity/ Slot.6. Connectivity Interface: 1 Nos. x 10/100/1000 Mbps Ethernet Ports,1 x RS485,1 x RS2327. Backup Interface: Its should have 2 Nos x USB port (1x USB 3.0, 1 x USB 2.0)8. Video Output Ports: 1 x HDMI and 1VGA9. Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10. Email & SMS Alert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempering, network disconnection and panic11. Web & Mobile Application: Web, Mobile app (For iPhone, iPad, Android Phone) for alerts and viewing.12. Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13. Standards: CE, FCC, RoHS and BIS Certified14. Power Supply : Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply. 15. Operating Condition : Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing)16. The VMS, NVR application shall support all the features & functionalities of the offered cameras.17. VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses, with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18. The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19. The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20. Must support Resolution: 7680x4320 (8K), 3840*2160, 1920×1080, 1280×1024,1280×720, 1024×76821. Must support recording resolution upto 32MP22. Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode23. When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page 24. The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm25. It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to one avi/MP4 file.26. General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.27. Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan28. Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.29. Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection30. Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec.31. Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.32. ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.33. Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cyber security exception34. Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.35. General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.36. Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiencyVCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics 16 Channel Network Video Recorder (NVR) having display split:- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16
310DSR item No.40.12.4 Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 10TB (Terabytes)
311DSR item No.39.3.1 Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 4 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS, TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: FCC, CEmarked, UL/EN, RoHS and relevant MTCTE(TEC)/ BIS compliance/ certification as applicableetc. complete as required. 24portPoELayer2NetworkSwitchwithPoESupportof 370W or higher with each cooper port supporting 802.3at PoE+ min.
312DSR item No.39.1.1 Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 degree Celsius to +50 degree Celsius. Jumbo frame: 9KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP- MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: FCC, CE marked, UL/EN, RoHS and relevant MTCTE(TEC)/ BIS compliance/ certification as applicable etc. complete as required. 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+.
313DSR item no.39.23 Supply and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U Rack
31415U Rack
315DSR item No.39.17.1 Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range: -5° to +60°C. Bending Radius: < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg. 1 Run of cable
316Supply & laying of PVC copper wire 1.5 mm sq. 3 core round sheathed wire on existing surface with suitable clamps/ hanger etc. including making connection and petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The copper wire should be of Polycab/ L&T/ Havells/ Finolex/ R.R. Kables make only
317DSR Item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
318DSR item no.42.4.3 LED Display Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required. 55 inch or larger
319DSR item no.26.1.1 Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz + 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge, 10 KV surge. Display for watt/VA, Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3). The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. 2 KVA
320DSR item No.39.12.1 Supplying, Installation, Testing and commissioning of following CAT6 Patch Cordshould have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D CopperPatchCordsoflength1m(3ft)
321DSR item no.39.11 Supplyof24portCat6PatchPanelloaded.Mustbeof1U heightwithclearlabelholdersandwhitelabelwiththepanel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required
322Provision of Fire Sensing SystemDSR Item No. 28.2.1.2 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loopmodules and capable of supporting not less than 240devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communicationcard, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealedmaintenancefreebatterieswithautomaticcharger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System)and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel.
323DSR Item No. 28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required.
324DSR Item No. 28.5.1 Supplying & laying of 2x1.5 sq. mm fire survival armored cable, 600/1000V rated with annealed copper conducted having glass mica fire barrier tape covered by an extruded layer of cross linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
325DSR item no.26.1.1 Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz + 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge, 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc.2 KVA
326S/I/T/C of fire exit sign board illuminated made from etched sheet with LED illumination and all electrical accessories included battery and battery charge etc. on ceiling/ wall mounted with logo & exist arrow) Make:-Glowline/ HHE/ Ravel/ Honeywell.
327DSR Item No. 1.20 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of Surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25 mm
328DSR Item No. 28.2.16 Supplying, installation, testing & commissioning of addressable strobe complete as required.
329DSR Item No.28.3.1 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
330DSR Item No. 28.3.7 Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
331DSR Item No. 28.3.4 Supplying, installation, testing& commissioning ofceiling/wall mounted loudspeaker,3/1.5Watt in ABS enclosure complete as required.
332DSR Item No. 28.5.3.1 Supplying and drawingof cable Fire Retardant PVCinsulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speakercable Singlepair,2-core,1.5sq. mm
333Supply installation testing and commissioning of 2X12 watt wall mounted Industrial Double Beam emergency LED light with exit sign board. The fitting should have CRCA steel housing, 50000 burning hours, battery of suitable capacity for emergency backup of 4 to 5 hours. The fitting should be fully automatic i.e. automatic on in case of normal supply failure and automatic off as power resumes. The battery should have inbuilt protection for over, under charge and short circuit protection. The job also includes the cost of testing commissioning and making connections and other petty material and labor etc. as required to complete the job to be entire satisfaction of EIC (Make -Mr Lite, Tech Lite, Advent) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57442050
AUTHORITY Local Bodies
TENDER VALUE 23.77 Crore
LAST DATE 28-09-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for Construction Of Boys Hostel (Hostel No. 2) In Ccet, Sector-26, Chandigarh. (Composite Work)
Basic Detail
Tender No CP3/2026/2943888
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 10 Sep 2026
Submission Date 28 Sep 2026
Open Date 28 Sep 2026
Finance
Tender Value 23.77 Crore
Tender Fee Ref. Documents
EMD 33.77 Lakhs
Exemption Not Available
Document List
059df171-c41c-47bc-9388-5e4369caa5a6.html
BOQ_117051.xls
Tendernotice_1 (26).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Sep 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.