Tender For Renovation Of Govind Vatika In Rose Garden At Bhakra Dam
Tender Value
7.08 Lakhs
Estimated cost
Bid Submission
10 Oct 2026
26 days left
EMD
14170
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bilaspur → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Govind Vatika In Rose Garden At Bhakra Dam
BOQ
| Sl. No. | Item Description |
| 1 | A.Civl Works :- Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. ( CSR item No. 10.2 ) |
| 2 | Centering and shuttering for columns (circular or curved in plain) ( CSR item No. 9.5 ) |
| 3 | First class burnt brick work laid in cement sand mortar 1:6 in first storey. upto 4 metres above plinth level. ( CSR item No. 11.4 (i) ) |
| 4 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves ( CSR item No. 9.8 ) |
| 5 | Centering and shuttering for sides and soffits of beam, beams. Launching girders, bressumers,lintels ( CSR item No. 9.6 ) |
| 6 | Centring and shuttering for parapet, fascias and other similar items including edges ( CSR item No. 9.1 ) |
| 7 | Cold twisted deformed (Ribbed/ Tor steel) Bars Fe500 grade as per IS 1786-2008) , for R.C.Cworks, where not including in the complete rate of RCC including bending and binding placing in position complete ( CSR item No. 18.18 ) |
| 8 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete a. Size 600x600 mm ( CSR item No. 14.113 (a) |
| 9 | Nicking cement concrete surface (over 28 days old including preparation and laying slurry ( CSR item No. 10.31 ) |
| 10 | Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixedwith pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps 20 ( CSR item No. 14.87 ) |
| 11 | Providing and fixing 10 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings. all complete as per direction of Engineer-in-charge ( CSR item No. 17.101 ) |
| 12 | Plastering on walls 6 mm thick cement plaster 1:3 ( CSR item No. 15.2 ) |
| 13 | 12.5 mm thick cement plaster 1:6 ( CSR item No. 15.11 ) |
| 14 | Terracing consiting of tiles 22.86x11.43x 3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/Sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing ( CSR item No. 13.13 ( i) |
| 15 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 ( CSR item No. 13.45 ) |
| 16 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. ( CSR item No. 13.55 ) |
| 17 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf/cm2) conforming to IS: 4985, including fixing with MS clamps (a) U-PVC pipes (working pressure 4 kgf/sqcm) pipe 110 mm dia. ( CSR item No. 13.74 (a) (i) |
| 18 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge. (a) UPVC 110 mm bend ( CSR item No. 13.75 (a) |
| 19 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish ( CSR item No. 16.65 ) |
| 20 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) ( CSR item No. 16.63 ) |
| 21 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS: 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin-charge. ( CSR item No. 17.48 ) |
| 22 | Handle door lock RFID card + pin based Access Control ( Market rate ) |
| 23 | B. Electrification Charges :- RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1 1⁄2\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring fan point (With fan box) ( CSR item No. 34.02 (i)(b) |
| 24 | White Crystal Circular LED surface ceiling Light ( Market rate) |
| 25 | RECESSED HDPE PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall 1.5sq. mm, 1100volts grade to be laid in HDPE electrical conduit pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-(ii) Wiring light point ( CSR item No. 34.03 (ii) |
| 26 | (i) a. Wiring fan point (Without fan box) ( CSR item No. 34.03 (i)(a) |
| 27 | (iv) Wiring 6Amp. wall socket point ( CSR item No. 34.03 (iv) |
| 28 | (vi) Wiring 16/20Amp. power plug control point ( CSR item No. 34.03 (vi) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender