Road Transport and Highways Government Departments Closing in 21 days TDR #57439724

Tender For Renovation Of Cafeteria, Construction Of Pergola And Redesign Of Reception Gate At Iahe C Us, Noida

Issued by Government Departments · Gautam Buddha Nagar, Uttar Pradesh
Tender Value
2.33 Crore
Estimated cost
Bid Submission
05 Oct 2026
21 days left
EMD
4.68 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gautam Buddha Nagar → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Renovation Of Cafeteria, Construction Of Pergola And Redesign Of Reception Gate At Iahe C Us, Noida

BOQ

Name of Work:- Renovation of Cafeteria, Construction of Pergola and Redesign of Reception Gate at IAHE C us, Noida
Sl. No. Item Description
1Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazingand false ceiling including disposal of unserviceable material and stackingof serviceable material with in 50 meters lead as directed by Engineerin-charge. (Aluminium Door and Windows) Holdfasts embedded in masonry must be carefully chiselled out rather than yanked, to avoid deep cavities in the existing brickwork.Serviceable glass, wood, or hardware should be stacked separately for potential salvage or client handover.
2Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 metres lead : of area 3sqm and below (Other door and windows) Holdfasts embedded in masonry must be carefully chiselled out rather than yanked, to avoid deep cavities in the existing brickwork.Serviceable glass, wood, or hardware should be stacked separately for potential salvage or client handover.
3Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (minor brick wall changes + Brick work below kitchen counters)Execution Scope:- Cutting a neat groove using a mechanical cutter at the junction of the wall to be demolished and the wall to be retained. (to prevent crack propagation into the retained masonry.)
4Dismantling stone slab flooring laid in cement mortar including stackingof serviceable material and disposal of unserviceable material within 50metres lead. (kota stone and granite)Execution : Use appropriate chipping hammers to chip off base mortar completely ensuring Zero level, but avoid gouging too deep.
5Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. (For thickness of tiles 10 mm to 25 mm) (wall tiles )
6Dismantling Wash Basin of any size including dismantling of trap, unions, waste coupling, C.P. fittings , breaking of pipes and making good the walls/floors where required, and , stacking useful materials within 50m lead and disposal of unserviceable materials into municipal dumps (within 50m) as per direction of Engineer-in-Charge. (old wash basins)
7Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer -in - charge. (old kitchen counters and slabs AND UTILITY TRENCHES)
8Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (for utility trenches and pergola's RCC pedestals) Excavation Width: 115 mm (Left Brick) + 400 mm (Internal Clear) + 115 mm (Right Brick) = 630 mm total width to dig.Excavation Depth: 100 mm (PCC Base) + 400 mm (Max Internal Depth) = 500 mm total depth to dig.
9Providing and making straight, true and controlled cuts in the existing marble terrazzo flooring, including cement mortar bedding/screed, to a total depth not exceeding 50 mm, using an electrically operated diamond saw-cutting machine, along the marked perimeter of openings required for RCC footing and pedestal works, including setting out, temporary protection of adjoining finished flooring, water/dust suppression, collection and removal of cutting slurry, labour, tools and plants, blade consumption, electricity, transportation and mobilization, complete as directed by the Engineer-in-Charge.
10Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer -in - charge. (Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
11Nominal concrete 1:4:8 or leaner mix (including equivalent design)
12Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Note- Client retains the scrap
13Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
14Demolishing R.B. work manually/ by mechanical means including stacking of steel Bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. NOTE : ALTERNATIVE/PROVSIONAL ITEM. ITEM 15.4 AND 15.53 The quantities provided for demolition of RCC and R.B. members are provisional. Before demolition, representative members shall be locally exposed in the presence of the Engineer-in-Charge. Each member shall be classified as RCC, R.B. work or ordinary brick masonry based on its actual construction. Payment shall be made only under the applicable BOQ item for the actual measured quantity. No member or portion thereof shall be measured under more than one demolition item. (TOTAL VOLUME 8.42)
15Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.
16Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge.
17Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all Leads including all lifts involved. Debris must be cleared from the site daily or stacked neatly in a designated zone to maintain a safe working environment and prevent obstruction to subsequent trades.
18(Providing and laying a leveling course of Plain Cement Concrete (PCC) at the bottom of the excavated trench pit minimum100 mm depth, base for RCC pedestals and Flooring) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)(APPROVED MAKES :- Ultratech, ACC, Ambuja. OR EQUIVALENT AS APPROVED BY EIC)
19Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with cement concrete 1:1.5:3 using graded stone aggregate 20 mm nominal size
20(M25 RCC FOOTING) Providing and laying in position machine-batched and machine-mixed design-mix reinforced cement concrete of M25 grade in foundations and footings, excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures wherever required, complete as directed by the Engineer-in-Charge.
21(M30 RCC PEDESTALS + STRAP BEAMS+ TIE BEAM) Providing and laying in position machine-batched and machine-mixed design-mix M30 grade cement concrete for reinforced cement concrete work, including pumping and approved admixtures, but excluding the cost of centering, shuttering, finishing and reinforcement, for all works up to plinth level, complete as directed by the Engineer-in-Charge.
22(FOR FOOTING)Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
23(FOR RCC PEDESTALS)Centering and shuttering including strutting, propping, removal of formwork and all necessary supports for columns, pillars, piers, abutments, posts and struts, complete.
24(FOR TIE AND STRAP BEAMS, LINTEL) Centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressummers and cantilevers, complete.
25Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
26Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
27Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
28(Column and Top Beeam) Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete:- Concrete of M25 grade with minimum cementcontent of 330 kg /cum
29Formwork for Metal Plaque Inlay: Providing materials and executing temporary blockouts within the structural brickwork to create a 30mm deep niche for the flush installation of the SS directory plaque.(Project Spec: The civil contractor must fabricate a rigid marine-plywood dummy box. The overall outer dimensions shall strictly be 2260mm (Width) x 1435mm (Height) x 150mm (Depth), or as per the final GFC elevation drawings. This formwork must be placed directly below the typography blockout, perfectly plumb and aligned. Once extracted, it must leave a razor-sharp 30mm deep masonry void. Manual chiseling is strictly prohibited). Measurement method = Area only
30Structural Masonry Rebate for Inlay Cladding: Executing a continuous, full-height architectural rebate (setback) of 115 mm depth within the superstructure brickwork (or RCC) of the designated pillars and boundary walls.(Project Spec:1. Execution Method: The rebate must be formed integrally during the masonry phase by modifying the structural bond (e.g., precision-cut brick facings or brick-on-edge courses) to achieve the exact specified depth. For any RCC portions, precision blockouts must be used within the shuttering. 2. Substrate Preparation: The recessed masonry joints must be raked out to a minimum depth of 10mm while the mortar is green, and any RCC surfaces must be mechanically hacked, to provide a sufficient mechanical key for the polymer-modified stone adhesive.3. Tolerances: The depth of the rebate must accommodate the combined thickness of the natural slate (15-20mm) and the Class C2TE adhesive bed (20mm), ensuring the final stone face is atleast 75 mm recessed from the adjacent Archi-Concrete finish for installation of round downlighter as in item :- 4. Prohibitions: The artificial building-up of adjacent wall surfaces using thick cement mortar (plaster) to simulate this recess is strictly prohibited. The rebate must be monolithic to the core structure).
31Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level in 1:4 cement mortar (New Walls +closing door opening from 2.7 m to 2.1 m)
32(vertical retaining walls of the utility trench) Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :Cement mortar 1:4 (1 cement :4 coarse sand)To be built directly on top of the cured PCC base, stopping precisely at the required height to accommodate the SS frame and covers for utility trench
3312 mm cement plaster of mix 1:4 (1 cement : 4 fine sand) on the new brickwork. Area to be measured in Sqm. (both walls and utility trench)Approved makes : - Cement: Ultratech, ACC, Ambuja.
34Extra for Waterproofing of trench plaster :- Cement plaster mix must be mixed with an integral liquid waterproofing compound strictly as per the manufacturer's dosage.The mason must trowel the bottom floor of the trench to create a strict 1:100 slope pitching continuously toward the trench's floor drain. It must be finished smooth with a floating coat of neat cement.(APPROVED MAKES :- Fosroc Conplast or Dr. Fixit PidiproofOR EQUIVALENT AS APPROVED BY EIC)
35Food-Grade Epoxy Trench Lining :- Supplying and applying a chemical-resistant, food-grade epoxy resin coating to the fully cured, dry internal plaster of the trench.Preparation: Mechanical wire-brushing of the plaster to remove loose dust, followed by a coat of compatible epoxy primer.Coating: Two thick top-coats of heavy-duty, solvent-free epoxy floor coating .Empty buckets of the primer and the top-coat to be shown to EIC Color: Light grey or light blue (light colors so that any dirt, leaks, or pests inside the trench can be instantly spotted with a flashlight).(APPROVED MAKES :- MAPEI Mapefloor EP 19, FOSROC NITOFLOR EPOXY MORTAR OR EQUIVALENT AS APPROVED BY EIC)
36Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4
3712 mm cement plaster of mix: 1:6 (1 cement : 6 fine sand) on the new masonry surfaces.
38Extra for Waterproofing in Plaster: Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.Standard dosage to be 1 liter per 5 bag (50kg) of cement(Measured and paid for the exact liters/kilograms of Dr. Fixit or Fosroc added to the plaster mix to fight the capillary dampness from the adjacent drain).
39Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (Hot finished welded type tubes)
40Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
41Providing, fabricating and fixing cast-in high-tensile holding-down anchor-bolt assemblies of property class 8.8, comprising M30 J-type anchor bolts with threaded top ends, double heavy-duty nuts, plain washers, bending, threading, cutting, positioning with template and maintaining line, level and bolt projection during concreting, complete as per approved structural drawings and engineer’s approval.
42Providing and placing approved pre-packed, free-flow, high-strength, non-shrink cementitious grout below structural-steel column base plates, including surface preparation, temporary edge shuttering, mixing, pouring, compacting, finishing and curing, complete as per manufacturer’s specifications and directions of the Engineer-in-Charge. (APPROVED MAKES :- ULTRATECH, FOSROC CONBEXTRA OR EQUIVALENT AS APPROVED BY EIC)
43Providing and fixing wet utility-trench cover and drainage accessories for 300 mm clear-wide masonry trench, comprising SS 304 supporting angle frame, minimum 40 × 40 × 5 mm, anchored securely to RCC coping/masonry with SS fasteners; removable anti-skid SS 304 grating fabricated from serrated flats, suitable for pedestrian and kitchen-trolley loading; SS 304 trapped outlet with minimum 50 mm water seal and removable perforated solid-waste strainer basket, connected to the adjoining separately measured 110 mm dia waste pipe; including cutting, welding, fasteners, sealing, making good, testing for free flow and leakage, complete as per drawings and directions of Engineer-in-Charge.
44Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer.Specification: To be used for fabricating 16mm thick MS insert plates equipped with minimum 150mm, 20 mm dia long welded shear studs/J-bolts (Fe 410 grade). These plates must be embedded perfectly plumb and flush into the M25 RCC column formwork prior to concrete casting to serve as the structural anchorage for the heavy gate hinges (Approved Makes :SAIL, Tata Steel, Jinda or approved equivalent)
45Primary RHS Framing: Fabrication of deep rectangular gate frames using 100x50x5mm RHS and internal verticals using 50x25x2.5mm RHS. (Orienting the 100x50mm tubes with the narrow side facing, while the 100mm depth). Approved Make : Tata Structura, APL Apollo or approved equivalent
46Structural Facade (Stressed Skin Design): Providing, fabricating, and fixing 4mm thick Hot Rolled (HR) Mild Steel Plate (IS 2062 Grade E250). The plate is to be precision CNC Fiber Laser-cut(or water jet cut) to the approved \\"highway and dashed lines\\" architectural graphic design.The scope of work includes continuous/stitch-welding the laser-cut plate to the internal tubular framework to act as a structural shear panel, grinding all welds perfectly flush, and ensuring zero heat distortion (oil-canning).Note: All visible welds must be ground flush and finished smooth with a flap disc to ensure zero weld-splatter is visible before painting. Rate is all inclusive of material, laser-machine time, inert gas, welding consumables, and heavy scrap wastage generated by the cut-out graphics. To prevent warping of the sheet the welder must employ skip welding technique (weld 50mm, skip 200mm or stitch welding). CONTRACTOR MUST ENSURE 1:1 MOCK PANEL MADE OF PAPER AND GET IT APPROVED ROM E-I-C BEFORE EXECUTING THE FINAL DESIGN.EIC'S DECISION REGARDING DESIGN WOULD BE FINAL AND BINDING. EIC RESERVES THE RIGHT TO CHANGE THE DESIGN. Approved Make : SAIL, Tata Steel, Essar or equivalent approved
47Heavy-Duty Hinge Assemblies: Custom fabricated pivot system. Bottom hinges to feature heavy-duty Thrust Roller Bearings (min. 750kg load rating per bearing). Top hinges to be machined MS trunnion/sleeve type with grease nipples. Welded directly to embedded anchorage as in Item 3.1.Approved Make : SKF, FAG, NBC (Bearings) or equivalent approved
48Gate Logo: Providing, fabricating, and fixing custom circular institutional logo plates (\\"IAHE\\").Specification: Made from 2mm or 3mm thick Stainless Steel (SS 304 Grade) plate with a brushed/satin finish and Dia as per drawing (690 mm). Profile and internal lettering to be precision CNC Laser-cut (Nitrogen assist).Mounting: To be mounted using concealed SS threaded studs welded to the rear, incorporating nylon spacer washers to maintain a minimum 2mm isolation gap from the MS gate frame to prevent galvanic corrosion. Approved Make : Jindal Stainless, SAIL, Tata Steel. or equivalent approved
49Portal Sub-Framing and Guard Room Roof Band: Fabrication and fixing of an internal skeleton frame using heavy MS tubular sections (e.g., 40x40x3mm RHS), coated with epoxy primer, to act as the rigid base for the reception portal cladding. Scope includes :- Grid Spacing: MS RHS verticals at 400mm c/c and at Perimeters ; horizontal noggins at 1200mm c/c.Standoff Mounting: Direct wall-mounting of the RHS is strictly prohibited. Frame must be decoupled from the civil wall using the MS cleat system.Load Bearing: For the Guard Room roof band, structural cleats must anchor strictly into the RCC lintel, not infill brickwork.Corrosion Prep: Mechanical grinding all MS members. Applying two coats of Two-Pack Zinc Phosphate Epoxy Primer. All site welds must be ground flush and re-primed immediately. Galvanic Isolation (Mandatory): Direct contact between MS frame and SS cladding is strictly prohibited to prevent rusting. Apply continuous EPDM gasket/VHB tape over the front face of the MS grid before fixing SS panels. Flush Integration : Rate to include precision laser-alignment of MS sub-frames to achieve a \\"Zero-Plane\\" flush finish with adjacent Archi-Concrete walls. Includes provision of a 5mm expansion reveal, machine-finished SS edges, and application of non-staining black structural silicone. No extra payment for stepped-masonry or sub-frame offsets. EXECUTION NOTES :- Wall-to-Cladding Assembly (Order of Fixing)Substrate: RCC or First-Class Brickwork.Anchor: M10x100mm Mechanical Expansion (Hilti HST3 / Fischer FBN II for solid RCC/Brick).Cleat (Standoff): 75x75x6mm MS L-Angle (100mm length).Sub-Frame: 40x40x3mm MS RHS welded to cleats.Galvanic Isolator: 2mm EPDM Gasket or 3M VHB Tape.Fascia: 1.5mm PVD SS Cladding.
50Matte PVD SS Cladding: Providing and fixing 1.5mm thick Stainless Steel (SS 304 Grade) sheet. Surface must be strictly Bead-Blasted (Matte) texture, treated with Titanium PVD coating (Matte Titanium ), and factory-sealed with a baked Anti-Fingerprint (AFP) nano-coating. Scope includes :- CNC V-grooving and 90-degree folding for crisp, seamless edges. Installation strictly via concealed structural cleats and 3M VHB tape to ensure a 100% screw-less, undulation-free aerospace facade).Approved Makes: Jindal Stainless (Base), Specialist PVD coaters
513D Portal and Guard Room Signage: Providing and fixing solid powder-coated metal lettering (\\"RECEPTION GATE / स्वागत\\") in a Matte Black or Dark Anthracite finish, mounted with concealed stud fixings onto the Matte PVD SS fascia on reception portal and Guard Room. No Visible screws permitted Note- measurement by Bounding Box Method i.e. Height x Total Width of all letters. Approved Makes : Jindal Stainless, SAIL or approved equivalent
52Low Relief Typography (75mm Intaglio): Executing structural recessed typography (\\"IAHE\\" or similar branding) into the masonry wall prior to final finishing. Minimum finished depth of recess strictly to be 75mm.Execution Note for 75mm Foam Extraction:Prep: Foam must have a 1°-2° draft angle, embedded pull-screws, and a silicone/water-based release agent (Diesel/oil strictly prohibited).Timing: Extract strictly during the \\"green\\" initial-set phase. Allowing mortar to fully cure before removal is banned.Method: Perpendicular pull via embedded screws only. Prying with tools or wiggling is prohibited.Finishing: Dress and smooth internal returns with a damp sponge immediately upon extraction. Project Spec: Executed using the CNC High-Density XPS Foam Void method. Note: If 75mm thick XPS is unavailable, the vendor must seamlessly laminate 50mm and 25mm sheets prior to CNC routing. Scope includes packing high-strength polymer-modified mortar around the 75mm template, extracting the template, and finishing the internal 75mm returns with the Archi-Concrete texture. The back-face of the deep recess to be coated with Matte Black Aliphatic PU paint to enhance structural shadowing before applying the clear silane-siloxane sealer. Hand-carving into wet plaster is strictly prohibited). Note- measurement by Bounding Box Method i.e. Height x Total Width of all letters
53Internally Illuminated Matte PVD SS Information Plaque: Providing, fabricating, and fixing a high-end, internally lit architectural directory plaque into the pre-formed 30mm masonry niche (executed separately under civil Item 1.6.5).(Project Spec:1. Fabrication: Crafted from 2mm thick SS 304 Grade sheet. Edges must be strictly CNC V-grooved on the reverse side prior to folding to achieve razor-sharp 90-degree returns (25mm deep pan profile). Finish to be Bead-Blasted (Matte) with Titanium PVD Anthracite Black and Anti-Fingerprint (AFP) nano-coating.2. Illuminated Typography: Text strictly CNC laser-cut completely through the metal face, backed internally with 3mm milky-white translucent cast acrylic.3. Lighting: Factory-installed IP67 dot-free LED modules (4000K).4. Installation: Flush-mounted into the pre-existing masonry niche via concealed SS cleats. The vendor must connect the internal LEDs to the pre-laid 12V/24V DC conduit drop. Perimeter gap seamlessly sealed with matte black structural polyurethane sealant (e.g., Sikaflex) to ensure a perfectly flush fit with the Archi-Concrete. No visible hardware permitted). Execution Notes :-Light Containment: Internal pan corners must be 100% opaque; light emission is strictly restricted to the laser-cut typography.Uniform Diffusion: LED depth and density must be calibrated to ensure a smooth, uniform glow across the acrylic without visible \\"hot spots\\" or LED dots.Flush Perimeter Seal: Plaque must be installed perfectly flush within the 30mm niche. The 2–3mm perimeter gap must be masked and sealed with a sharp, straight bead of Matte Black structural PU.Surface Protection: Absolutely no visible hardware permitted. The AFP (Anti-Fingerprint) surface must be protected during sealing; any sealant smudges on the PVD finish are grounds for rejection.
54Premium Vitrified Wooden (medium walnut/smoke teaked) Plank Flooring:- Providing and laying Vitrified tiles in floor, skirting, and steps.Tile Type: Glazed Vitrified Tiles (GVT) with a high-definition digital wooden print and matte/rustic textured finish. Minimum thickness of 9 mm to 10 mm. Water absorption less than 0.05%.Dimensions: Plank format, strictly 200 mm x 1200 mm (or 200 mm x 1000 mm).Base: Laid on a 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) sub-base, including grouting the joints.(APPROVED MAKES :- Kajaria (Woodex series), Somany, Nitco, or Qutone. Epoxy Grout (Make: Laticrete, Ardex Endura, or Roff) OR EQUIVALENT AS APPROVED BY EIC) Planks must be laid in a 33% (1/3rd) offset stagger. 2).TILES should be laid using 2mm plastic T-spacers between every plank. 3)wedge-and-clip tile leveling system should be mandatorily used during installation to ensure flush finish. 4) Epoxy Grout custom color-matched to the darkest grain in the wood tile should be used
55FOH Counter Facade (Moroccan Tile Apron)Specifications: Providing and fixing decorative Moroccan-patterned tiles to the vertical face/apron of the FOH service counter.Adhesive: Fixed using a high-strength, non-slip vertical polymer-modified tile adhesive (Make: Laticrete 290 or Roff Non-Skid) applied with a 6mm notch trowel to ensure zero hollow spots.Grouting: Joints filled with stain-proof, 100% solid epoxy grout in a complementary shade.Corner Detailing (Crucial): Where the tiles meet at the outside corners of the counter, the mason must meticulously miter-cut the edges at 45 degrees.
56Premium Natural Wood Veneer Paneling for FOH Columns (NSR)Providing and fixing premium natural wood veneer paneling to RCC/masonry columns (from FOH Counter level upto 2.2 m height ).Substrate: Framework of 12 mm thick BWP (Boiling Water Proof) Marine Grade Plywood, plumbed perfectly straight and secured to the column using heavy-duty PVC rawl plugs and SS screws.Surface: 4 mm thick premium natural decorative wood veneer ( American Walnut) pressed onto the plywood substrate using premium synthetic resin adhesive (Fevicol Marine or equivalent).Finish/Polish: Finished with 3 to 4 coats of premium Non-Yellowing Acrylic Polyurethane (PU) Polish in a Matte or Satin finish, applied via mechanized spray gun.(APPROVED MAKES :- Veneer: Greenlam (Decowood), CenturyVeneers, or Turakhia. PU Polish: Asian Paints (Woodtech Emporio PU), ICA Pidilite, or Sirca. OR EQUIVALENT AS APPROVED BY EIC)
57Extra for Solid Wood Decorative Beading/Molding (NSR)Extra for providing and fixing solid wood decorative molding (half-round profile) to the face of the veneered columns to create a framed panel aesthetic.Material: Solid timber strictly matching the underlying veneer species (Solid American Walnut beading over Walnut veneer).Placement: Fixed with a precise 50 mm offset inwards from all outer perimeter edges of the column face, forming a continuous rectangular frame.Finish: To be coated and sealed simultaneously with the base veneer using the same 3 to 4 coats of premium Acrylic PU Polish.
58Premium Glazed \\"Handmade-Look\\" Subway Brick Tiles (NSR)Providing and fixing premium glazed ceramic brick/subway tiles to the FOH backwall.Finish: Glossy White glaze with a subtle, undulating \\"handmade\\" (Zellige-style) wavy surface texture.Dimensions: Standard elongated brick format (75 mm x 300 mm).Adhesive: Fixed to the plastered wall using high-strength, White polymer-modified vertical tile adhesive applied with a notch trowel.Grouting: Joints (approx. 2mm wide) to be filled with 100% solid epoxy grout in a contrasting Light Silver Grey or Slate Grey shade.(APPROVED MAKES :- Nexion, Qutone, Somany (Artisan collections), or imported Spanish ceramics. Adhesive ( Laticrete 277 White, Roff White, or equivalent) OR EQUIVALENT AS APPROVED BY EIC) 1.Use of grey cement or grey tile adhesive is prohibhited. 2. Grout should be in contrast to highlight the brick pattern.3.Where the tiled wall ends at an outside corner, the exposed tile edges must be capped with a sleek, Black Aluminum L-profile trim. Cheap PVC plastic corner beads are strictly prohibited.
59Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. OF SIZE 600mm X 600 mm.The heavy-duty floor tiles must be laid first, going all the way to the edge of the wall. (BOH FLOOR TILES)
60Extra over Above Item ( 11.41.2 ) for providing heavy-duty, unglazed Full-Body Anti-Skid Vitrified Tiles (R10/R11 slip-resistance rating, e.g., Kajaria Heavy Duty or Endura) instead of standard glazed vitrified tiles.
61Extra over Item ( 11.41.2 ) or fixing tiles using high-strength, polymer-modified grey tile adhesive (Make: Roff or Laticrete) instead of standard cement slurry, to ensure zero hollow-sounding tiles under heavy trolley movement.
62Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (size 300 x 300) 1. Floor First, Wall SecondThe heavy-duty floor tiles must be laid first, going all the way to the edge of the wall.2. The 75mm Raw Plaster Zone:- Start exactly 75mm above the finished floor level so that there must be raw cement plaster exposed in that bottom 75mm gap. 3.Recommended:-The epoxy team should install the coving before the bottom row of wall tiles is laid.The coving should be troweled flat against the raw plaster. Once laid,the mason should then bring the wall tile down and rests the bottom edge of the tile slightly over the top lip of the epoxy coving. (to create a tiny overhang/drip course so that when the tiles are washed it does not seep into the wall)
63Extra over Item 11.37A for fixing wall tiles using polymer-modified vertical tile adhesive instead of standard 12mm cement mortar bed to prevent tile debonding due to kitchen heat.
64Pointing with 100% Solid Epoxy Grout in floors and dados/skirting of ceramic/vitrified tiles, including cleaning of joints, filling the joints with epoxy grout, finishing and cleaning the surface complete as per manufacturer's specification. (APPROVED MAKES :- MYK Laticrete SP100 or SPECTRA LOCK PRO, KERAKOLL FUGALITE ECO OR EQUIVALENT AS APPROVED BY EIC)
65Providing and executing 50mm radius food-grade epoxy resin mortar coving at all 90-degree floor-to-wall junctions. Work includes surface preparation, applying epoxy primer, and troweling the epoxy mortar to a smooth, seamless curved finish to comply with commercial hygiene standards and Painting over the entire curve with a liquid, high-gloss epoxy top-coat Once the shaped mortar cures rock-hard (usually 12 to 24 hours later).(APPROVED MAKES :- MAPEI Mapefloor EP 19, FOSROC NITOFLOR EPOXY MORTAR OR EQUIVALENT AS APPROVED BY EIC) The 50 radius epoxy should be troweled into the 75 mm Gap left in 11.37AThe applicator must trowel the top edge of the epoxy coving so it finishes absolutely flush with the surface of the ceramic wall tile above it. There should be no bump, lip, or ledge where the tile meets the coving.Recommended:-The epoxy team should install the coving before the bottom row of wall tiles is laid.The coving should be troweled flat against the raw plaster. Once laid,the mason should then bring the wall tile down and rests the bottom edge of the tile slightly over the top lip of the epoxy coving. (to create a tiny overhang/drip course so that when the tiles are washed it does not seep into the wall)
66Bi-Parting Automatic Sliding Glass Door :- Providing and installing a heavy-duty, commercial-grade automatic sliding door system in a Bi-Parting configuration (2 fixed outer panels, 2 sliding inner panels). Designed for an overall opening of approx. 2.4 m (W) x 2.1 m (H), providing a fast-opening 4 ft clear walkway.Operator: Slimline electromechanical operator (under 75mm height) designed for soffit-mounting directly beneath the structural beam. Capable of carrying the heavy dynamic load of 2.1 m tall glass leaves.Aesthetic Fascia: The entire motor housing/track cover must be powder-coated in a custom dark matte grey/black to perfectly match the adjacent aluminium window grid mullions.Glass: 12 mm thick Low-Iron (Extra-Clear) toughened frameless glass for all 4 panels. All exposed vertical edges to be CNC machine-polished.Sensors: Slimline, track-integrated microwave/radar approach sensors (color-matched to the track) to eliminate bulky plastic boxes on the wall. Includes invisible active infrared safety light curtains across the opening.Safety/Egress: System must include an integrated battery backup (UPS) to ensure doors automatically slide open and remain open during a total power failure (fire/safety compliance for 150+ occupancy). Approved Makes: Automation System: Dormakaba (ES 200 series or similar slimline), GEZE (Slimdrive series), ASSA ABLOY or Equivalent as approved by EICGlass: Saint-Gobain (Diamant), Asahi / AIS (Clear).or Equivalent as approved by EICSoffit Mounting: The vendor must anchor the track directly to the concrete soffit (bottom) of beam using heavy-duty chemical fasteners. Vendor must verify the beam bottom is perfectly level before mounting.Zero Threshold : The system must be \\"trackless\\" on the floor. It should only utilize concealed floor guides at the edges of the fixed panels.
67Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built-up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size. Finished with polyester powder coating to give an even shade with minimum thickness of 50 microns (Matte Black / Dark Anthracite).Approved Makes:- Aluminium Sections: Jindal, Hindalco, NALCO. Powder Coating: Jotun, AkzoNobel. 0r Equivalent approved All dash fasteners used to anchor the aluminium frames to the masonry jambs must be heavy-duty, galvanized steel or SS 304 expansion bolts (minimum 8mm dia x 75mm length)
68Providing and fixing 6mm thick Clear Toughened (Tempered) Glass in existing aluminium window frames/sashes.Scope of Work:• Supply of glass with machine-polished edges.• Installation into glazing beads/grooves using existing EPDM gaskets.• Application of neutral cure structural silicone sealant (if required for additional weatherproofing).• Cleaning of glass surface after installation.Inclusions: All material, labor, transportation, handling, wastage, scaffolding (up to 2 floors), applicable taxes (GST), and labor cess.Approved makes : Saint-Gobain / Asahi / Modiguard or approved equivalent
69Providing and fixing SS 304 grade heavy-duty concealed friction hinges to aluminium casement (openable) windows. Sized according to the weight and width of the glass shutter.Approved makes : Dorma, Kinlong, Ozone. or approved equivalent
70Providing and fixing aluminium/zinc alloy locking handles with keys for aluminium windows, color-matched (powder-coated black) to the window frames.Approved makes : Dorma, Kinlong, Ozone or approved equivalent
71WPC Door Frames (Chaukhats) Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 100 mmApproved makes :CENTURY PLY, GREEN PLASTWOOD or approved equivalent
72(Door)Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.35 mm thickApproved makes : CENTURY PLY, GREEN PLASTWOOD or approved equivalent
73Providing and fixing IS : 12817 marked stainless steel butt hinges withstainless steel screws etc. complete : 100X58X1.90 mm
74Providing and fixing heavy-duty mortice latch and lock of approved make, minimum 100 mm size, with six-lever locking mechanism, complete with SS 304-grade satin/matt-finished lever handles on both sides, SS 304 faceplate, strike plate, key escutcheons, spindle, matching keys and necessary stainless-steel screws.The item shall include cutting and forming the mortice in the door shutter and frame, proper alignment, fixing, testing, making good and all labour and accessories required to provide a smooth and fully operational locking arrangement, complete as per manufacturer’s specifications and direction of Engineer-in-Charge.Approved Makes: Dormakaba, Godrej, Dorset, Häfele, Hettich or equivalent approved
75Providing and fixing SS 304 mortice lock set to the active leaf of double-leaf door, complete with pair of SS 304 lever handles, cylinder, keys, faceplate, strike plate/rebate kit, matching dummy handles to inactive leaf, concealed SS flush bolts at top and bottom, screws, accessories, cutting, fitting, alignment, testing and making good, complete.
76Providing and fixing heavy-duty, premium quality Stainless Steel (SS 304 grade) solid extruded tower bolts (barrel type). Minimum size 150 mm length x 10 mm rod diameter (or 250 mm for taller doors as specified). Finished in a matte/satin brushed stainless steel. The item includes providing and fixing the matching SS receiver plate/socket and all necessary SS 304 counter-sunk screwsApproved makes: Godrej, Dorset, Hettich, Ozone, or Kich. or equivalent approved 1. For Fixing, M.S. screws are prohibhited. Only SS screws shall be used
77Heavy-Duty SS 304 Double-Acting Spring Hinges (KITCHEN DOORS) :- Providing and fixing premium quality, heavy-duty double-acting spring hinges (minimum 100mm / 4-inch . Manufactured from SS 304 grade stainless steel with a brushed/satin finish. The hinge must feature an adjustable spring tension mechanism to control the swing and closing speed. Capable of allowing the door shutter to swing up to 90 degrees in both directions and auto-return cleanly to the dead-center closed position. Includes providing and fixing with matching SS 304 counter-sunk wood/WPC screws. (Note: Typically 3 hinges per door leaf).Approved makes: Dorma, Hafele, Hettich, or Ozone. or equivalent approved
78SAFETY VISION PANEL FOR KITCHEN DOORS Providing, making the cutout, and fixing a safety vision panel in solid WPC door shutters (cutout area not exceeding 0.1 Sqm).Glass: 6 mm thick clear toughened (tempered) glass with machine-polished machine edges. (Standard float/annealed glass is strictly prohibited).Beading: Fixed using factory-extruded, color-matched WPC or slimline UPVC snap-on glazing beads with a flush profile. (Wooden beading is strictly prohibited).Approved makes: Glass: Saint-Gobain, Asahi (AIS), Modiguard.Sealant: Dow Corning, McCoy (Anti-fungal/Food-grade silicone) or equivalent approved Height & Alignment : The center of the vision panel must be placed exactly at eye level ( 1500 mm / 5 feet from the finished floor level). For double doors, the vendor must ensure the cutouts are perfectly horizontally aligned with each other.Hygiene & Waterproof Sealing: Before the glass and beading are fixed, the exposed inner core of the WPC cutout must be thoroughly lined with clear, anti-fungal silicone sealant. therefore preventing water seepage and mold/bacteria growthHardware Coordination: The carpenter must map out the cutout size (a vertical rectangle of 200mm x 450mm) to ensure it does not interfere with the mounting zones for the heavy-duty D-handles or the kick-plates.
79SS KICK PLATE FOR KITCHEN DOORS :- Providing and fixing commercial-grade, 1.2 mm thick Stainless Steel (SS 304 grade) kick plates to the bottom face of the door shutters.Dimensions: Height to be 200 mm (8 inches). Width to match the exact width of the door shutter minus a 5 mm clearance margin on each side to prevent the metal from scraping the frame.Finish: Brushed/Satin finish to hide daily scuff marks. All exposed edges must be machine-chamfered (beveled) and deburred at the factory so there are no sharp, knife-like edges to injure staff.Fixing: Fixed flush to the WPC/Laminate surface using a combination of heavy-duty structural adhesive (3M VHB double-sided tape or PU sealant) in the center, secured tightly along the perimeter with SS 304 counter-sunk screws.Approved makes: Ozone, Dorset, Hafele or equivalent approved
80(Window)Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete asper approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for :(i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3(ii) Sites with structure height more than 20m for all wind speedsUsing R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height upto 1.8m).
81(Door chaukhat)Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made Frame size 45 x 85mm
82Supply and Fixing of Dash Fasteners for WPC FramesProviding and fixing 10mm diameter x 100mm long (or suitable length as per site requirement) galvanized mild steel expansion hold fasteners (Dash Fasteners / Anchor Bolts) of approved make (e.g., Hilti / Fischer / Canon / Local Approved) for fixing WPC (Wood Polymer Composite) Door/Window Frames to the masonry/RCC opening.
83Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete: 200x10 mm. Approved Make : DORSET, La Reliant/Bharat Hardware/Azeen Enterprises/ as approved by EIC.
84Providing and fixing bright finished brass 70 X 200 X 70 mm cylindrical door lock of approved quality & design with necessary screws etc. complete. as approved by Engineer in charge (EIC).
85Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. Approved make: DORSET, kitch, ACE HARDWARE as approved by EIC.
86ROLLER BLINDS: Providing and fixing Fiber Plain Foldable Windows Roller Blinds all complete job as per specifications & shade as per directions of engineer in charge. Make: Vista material fabric type roller horizontal thickness 2mm pattern plain/ as approved by EIC. Approved make: VISTA MAC as approved by EIC.
87Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DINING + FOH ROOF+ BOH KITCHEN ROOF)
88Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre (DINING + KITCHEN +FOH ROOF) contractor must tint the primer dark grey/black by adding stainer before applying it. (If standard white primer, any future scratch on black ceiling will show up glaringly white).
89Painting minimum two coats, with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DINING + BOH KITCHEN ROOF+ FOH ROOF)Approved makes: Asian Paints Royale Matte, Dulux, or Berger or equivalent approved
90ANTI FUNGAL WASHABLE PAINT ON KITCHEN CEILING :- Applying two or more coats of High-Gloss, Anti-Fungal/Anti-Bacterial Washable Emulsion in Brilliant White.Approved makes: Asian Paints Apcolite Advanced Heavy Duty, or equivalent approved
91Providing and applying premium opaque white two-component polyurethane paint in satin-matt finish over HDHMR panelling, including sealing of cut and routed edges, filling of joints and imperfections, sanding, compatible PU sealer/primer, minimum two coats of white PU primer-surfacer with intermediate sanding, followed by minimum two spray-applied coats of non-yellowing white 2K PU topcoat, complete as per approved sample and manufacturer’s specifications.The item shall include hardener, thinner, putty, masking, spray application, rubbing, protection, labour, scaffolding and cleaning. The finished surface shall be smooth, uniform and free from visible joints, pinholes, scratches, sagging, orange peel, dust particles and shade variation.All faces, curves, routed edges and side returns shall be measured on the actual finished surface area.Finish: Satin-matt, approximately 20–30 gloss unitsColour: Approved white shade, preferably RAL 9010 / RAL 9016 or equivalentApproved Makes: Asian Paints WoodTech PU Palette Interior Satin / ICA Pidilite Finezza PU Pigmented System / Berger Imperia Trendz Acrylic 2K PU / equivalent approved premium make.Primer, surfacer, hardener, thinner and topcoat shall be from the same manufacturer’s compatible system.
92Providing and applying exterior-grade faux-wood protective coating on structural steel, comprising:1.Surface cleaning and abrasive blasting to Sa 2½.2.Application of zinc-rich epoxy primer.3.Application of high-build epoxy intermediate coat.4.Application of two-component aliphatic PU base coat in approved wood shade.5.Specialist faux-wood grain application.6.Application of UV-resistant, non-yellowing clear aliphatic PU satin topcoat.7.Stripe coating at welds, edges, corners and bolt heads.8.Preparation and approval of sample panel.9.Scaffolding, shop/site touch-up and DFT testing.Minimum total protective DFT: 240–300 microns. Approved Makes (or equivalent approved by Engineer-in-Charge):AkzoNobel International Paints (Interzinc, Intergard, Interthane series)Jotun Paints (Barrier, Jotamastic, Hardtop series)Hempel Paints (Hempadur, Hempathane series)
93Providing and fixing exterior-grade compact HPL cladding with stone-finish surface to all faces of structural-steel columns up to 1500 mm height above finished floor level, comprising:1.6 mm thick UV-resistant exterior compact HPL panels in approved stone finish (granite/marble/sandstone/slate texture as approved by the Architect).2.Galvanised MS supporting framework around the SHS columns.3.Minimum 20–25 mm ventilated cavity behind panels.4.Fixing with SS 304 screws/rivets or manufacturer-approved concealed fixing system.5.Aluminium corner profiles, edge trims and top termination flashing.6.Cutting, drilling, joint sealing, scaffolding and all incidental works complete.Approved makes: Greenlam Clads, Fundermax, Merino Exterior Compact Laminates, Stylam Exterior Cladding, Formica Exterior Compact HPL, or equivalent approved.
94Providing and fixing protective collar at the junction of HPL-clad pergola columns and WPC deck flooring, comprising:1.5 mm thick powder-coated aluminium sheet in matte black finish.100 mm high folded collar around the finished column enclosure.Collar fabricated in removable sections for future inspection.Fixed using concealed SS 304 rivets.EPDM isolation strip between collar, HPL and supporting frame.10 mm clearance between WPC decking and column cladding for movement and drainage.Neatly sealed vertical joints with compatible black exterior-grade sealant.Complete cutting, bending, powder coating, fixing and finishing.
95Stone veneer Cladding (Pillars and Dwarf Walls): Providing and fixing natural cleft Slate Stone (Charcoal / Black Rust ) in the pre-formed masonry recess (Item 1.6.6).(Project Spec:1. Stone: 15mm to 20mm thick natural slate, edges machine-cut for seamless dry-stacking (no visible cement grout lines between the stones).2. Adhesive: Stone MUST be fixed using heavy-duty, polymer-modified thin-set adhesive (Class C2TE S1) suitable for exterior vertical cladding. The use of standard cement-sand mortar is strictly prohibited as it will fail under the weight of the stone.3. Sealer: Upon completion, the stone must be washed and treated with two coats of a premium Color-Enhancing Penetrating Stone Sealer to lock in the \\"wet look\\" and prevent algae/fungus growth during monsoons). It should be done only after the stone is dry.
96Dual-Finish Automotive PU Paint System (Main Gate): Surface prep by mechanical grinding. Application of two-pack Epoxy Primer followed by Aliphatic Polyurethane (PU) exterior paint applied in two distinct finishes:1. Structural RHS Frame: Smooth, flat Matte Black finish.2. Laser-Cut \\"Highway\\" Plates: Dark Grey/Black base infused with a micro-texture/sand additive to achieve an ultra-matte, light-absorbing \\"highway tarmac\\" finish.(Scope includes meticulous masking between elements and stenciling the white dashed lines in matching PU on the textured plates.) Approved make : Asian Paints (Apcolite PU), Berger (Imperia), Nippon or equivalent approved
97Architectural Exposed Concrete System: Providing and applying a multi-layer mineral-based micro-concrete texture system over plastered boundary walls to authentically simulate form-finished brutalist concrete.Execution Scope:1. Primer: Application of quartz-grit adhesion primer.2. Texture Build-up: Trowel application of premium mineral/lime-based concrete plaster (min. 2mm to 3mm thickness in two coats).3. Detailing: Hand-crafted detailing to simulate staggered shuttering panel joints and perfectly aligned faux tie-rod holes at a 1200x600mm grid (or as per architectural elevation). 4. Sealer: Saturation application of two coats of 100% pure Silane-Siloxane penetrating protective sealer. Sealer must be completely invisible, non-yellowing, UV-resistant, and render the wall strictly hydrophobic (water-repellent) to prevent algae and dust ingress.(Note: The contractor must execute a 4ft x 4ft mock-up panel on site for the Enigineer in charge approval regarding color, porosity, and water-repellency before commencing full execution.). Approved Makes : (Luxury): Oikos (Concrete/Travertino), Novacolor (Wall2Floor)(Domestic): Suzuka (Strato), Asian Paints (Royale Play Archi Concrete)
98Stone Coping: Providing and fixing 18mm to 20mm thick Dark Grey Granite (Flamed Finish) for boundary wall capping. Stone to be laid on a 20mm thick cement mortar bed (1:4) mixed with water-proofing compound.Detail: Stone must be sized to provide a minimum 25mm overhang on both sides of the wall, and must feature a machine-cut 'drip groove' on the underside of the overhangs to throw rainwater away from the Archi-Concrete facade. Joints to be filled with matching epoxy grout.)
99Providing and fixing 18 mm thick factory-finished PET felt acoustic ceiling panels, manufactured from recycled polyester fibre, multicoloured, and CNC-cut in circular shapes. The panels are to be installed in a clustered and staggered format (grouped together and suspended at varying elevations to create multi-level, overlapping acoustic clouds) as per approved architectural drawings. Panels to be suspended from the RCC soffit/true ceiling using manufacturer-approved adjustable wire suspension systems (e.g., Gripple cables) or rigid threaded rods, complete in all respects.Finish: Colours strictly matching approved interior design material palette Beige / Taupe / Terracotta / Rust / Olive / Sage / Mustard / CharcoalTechnical Specifications : Density: Minimum 3.0 kg/sqm , Acoustic Performance (NRC) of 0.70 when suspended with an air gap, Fire Rating: Class A (ASTM E84) or Class B-s1, d0 (EN 13501-1)Sustainability: Minimum 60% post-consumer recycled PET contentVOC Emissions: Low VOC, Dimensional Tolerance: $\pm$ 2 mm for CNC-cut edgesColour Fastness: Minimum rating of 6-7 as per ISO 105-B02.AApproved makes:- Autex Acoustics ,Woven Image, MMT or approved equivalent Top-Down Sequencing (Crucial): The raw RCC slab,beams , and fire pipes must be painted in the dark matte black/grey before these acoustic clouds are brought to the site. Airspace Clearance: The suspension cables must be adjusted to hang the clouds as/drawing.
100Providing and fixing factory-finished, interior-grade fine-fluted WPC/CPC wall panelling of 18–20 mm overall finished profile thickness, fixed vertically over 50 mm deep aluminium section framework and 12 mm thick moisture-resistant HDHMR/BWP plywood backing board, complete as per approved elevations and shop drawings upto 900mm from FFL.The aluminium framework shall be fixed securely to masonry/RCC walls, properly levelled and aligned, with horizontal supporting members spaced at maximum 300–350 mm c/c. The backing board shall be mechanically fixed to the framework, with all cut edges duly sealed.WPC panels shall be fixed using manufacturer-approved adhesive, concealed clips and/or stainless-steel self-drilling screws, without any visible fasteners on the finished face., complete as per approved drawings Panels shall have narrow, closely spaced vertical flutes with fine shallow grooves, approximate flute pitch 15–20 mm, groove width 4–6 mm, matte/low-sheen light wood finish such as medium walnut or smoked teak or, golden oak, ash wood, beige oak or approved equivalent. Wide, deep or dark louver-type profiles shall not be accepted.Fixing method : manufacturer-approved adhesive with concealed screws, pins or proprietary fixing system. Exposed fasteners not permitted. Scope includes: surface preparation, adhesive, concealed fixing accessories, cutting, alignment, joints, corner/end trims, finishing around openings and services, wastage, labour, tools and making good complete.The panelling shall terminate neatly above specified skirting with a 3–5 mm shadow gap where indicated and shall include matching top capping/termination profile for separately specified concealed linear LED lighting.Panels shall be installed vertically in true line, level and plumb as per manufacturer’s recommendations. Major wall rectification, skirting, LED lighting components and electrical works shall be measured separately.Approved Makes :Alstone, Ecoste, Floresta,Hardyplast, Action TEsa or Equivalent reputed make approved by the Architect/Engineer-in-ChargeContractor shall submit manufacturer’s technical data sheet, product sample, finish, profile, colour shade and fixing details for approval before procurement and installation. Execution Notes:-Framework:-1. Provide **50 mm deep aluminium framework** fixed securely to wall.2. Maintain supports at maximum **300–350 mm c/c**.3. Check framework for line, level and plumb.Backing:-1. Fix 12 mm moisture-resistant HDHMR/BWP plywood over framework.2. Seal all cut and exposed edges.WPC Panels1.Use 18–20 mm thick fine-fluted WPC louvers.2.Finish: Golden Oak / Rustic Oak / Ash Wood as approved.3.Align all flutes vertically and uniformly.Fixing1.Use approved adhesive, concealed clips and stainless-steel screws.2.No visible fasteners shall be permitted.3.Allow for thermal expansion at joints and ends.Trims1.Provide matching edge trims, corner trims, end caps and top cap.2.Close all exposed or hollow panel edges.Finishing1. Coordinate cutting around doors, windows, switches and services.2. Clean and protect completed panelling until handover.
101Providing and fixing decorative high-relief curved/arched HDHMR wall panelling, comprising 50 mm deep aluminium section framework/furring securely anchored to masonry/RCC wall and 18 mm thick CNC-cut HDHMR front fascia, complete with all necessary spacers, reinforcement, backing members and accessories required to maintain the specified curved profiles, panel joints, edges and service locations.The panelling shall be formed into soft curves, arches, capsules and other profiles as per approved architectural elevations and shop drawings. Exposed edges shall be CNC-routed, smoothly rounded and prepared to receive the specified finish.SCOPE:50 mm deep aluminium framework at maximum 300–400 mm c/cAdditional framing at curves, joints, openings and corners18 mm thick CNC-cut HDHMR fasciaConcealed adhesive, screws, anchors and mechanical fixingsFactory cutting, routing and edge roundingMatching edge bands, side returns, closures and trimsCutting around doors, windows, switches and servicesSealing of all exposed and concealed HDHMR edgesFormation of recessed low-relief areas for decorative infillContinuous concealed COB LED strip, 2700–3000 KAluminium LED profile with opal diffuserConcealed wiring, connectors and LED driversRemovable access panels for electrical maintenanceNecessary shadow gaps and light outletsMaking good adjoining surfacesCleaning, protection and completion in all respects The finished HDHMR fascia shall project approximately 68 mm from the true wall, comprising 50 mm aluminium framework and 18 mm HDHMR fascia. The completed panelling shall be true to line, level and plumb, with uniform curves, accurately aligned joints and no visible fasteners.Approved Makes18 mm HDHMR: Action TESA / Greenpanel / Greenply / equivalent approved makeAluminium framework: Jindal Aluminium / Hindalco / equivalent approved extrusionLED strip and driver: Philips–Signify / Wipro / equivalent approved makeAdhesive and sealant: Sika / Pidilite / Bostik / equivalent approved makeActual materials, shade, technical data and samples shall be approved by the Engineer-in-Charge before procurement.
102Providing and fixing 18–20 mm thick factory-finished engineered quartz stone slab over window sills, in approved colour, shade and pattern, laid to line, level and required slope using manufacturer-approved polymer-modified adhesive, including surface preparation, cutting to required sizes and profiles, making openings, edge polishing, pencil-round/chamfered exposed edges, joints, matching neutral-cure silicone sealant at window-frame junctions, backing/support wherever required, cleaning and finishing, complete as per approved drawings and manufacturer’s specifications.Note: Sill shall project approximately 12–15 mm beyond the finished wall/WPC panelling face, unless otherwise shown in drawings (100 mm sill projection beyond the true wall/plastered wall face)Approved Makes: KalingaStone / Quantra / Johnson Marble & Quartz / AGL / Caesarstone or equivalent approved by the Engineer-in-Charge, subject to approval of actual slab, shade, pattern and physical sample before procurement. Execution Notes-Fix with manufacturer-approved polymer adhesive.-Provide firm backing/support to avoid deflection.-Maintain 100 mm extension beyond true wall.-Keep uniform projection along all windows.-Polish exposed front and side edges.-Provide slight chamfer/pencil-round edge.-Seal frame junction with matching neutral-cure silicone.-Keep sill level or with slight inward fall.-Protect completed quartz from impact and staining.
103Providing and fixing decorative French trim moulding panelling on masonry walls, comprising 12 mm thick HDHMR board fixed over prepared masonry/plastered surfaces with approved adhesive and concealed fasteners, and 25 mm wide ogee-profile HDHMR/MDF moulding trims fixed over the backing board to form decorative wall panelling in approved patterns, complete as per drawings and directions of the Engineer-in-Charge.The HDHMR board shall be of approved make such as Action TESA, CenturyPly, Greenpanel, Rushil Décor (Vir MDF/HDHMR), Archidply or equivalent. MDF mouldings, where specified, shall be of approved make such as Action TESA, Greenpanel, Century MDF, Rushil Décor (Vir MDF), Archidply or equivalent. Adhesive shall be Fevicol (Pidilite), Astral Adhesives, Jubilant Agri & Consumer Products, Huntsman or equivalent approved. The work shall include site measurements, setting out, cutting and fixing of HDHMR boards, fabrication and fixing of moulding frames, accurate mitring at corners, alignment of panel layouts, joint treatment, sealing of exposed edges, cut-outs around services, making good adjoining surfaces, scaffolding, handling, cleaning and protection of finished work, complete.The finished panelling shall be true to line, level and plumb, with neatly mitred corners, concealed fasteners and a uniform decorative appearance, complete as specified and directed.
104Providing and applying premium commercial-grade Type II vinyl wallcovering on non-woven/fabric backing in recessed wall panels, in approved colour, texture and pattern, including substrate preparation and levelling, primer, manufacturer-approved heavy-duty low-VOC adhesive, cutting, pattern matching, curved-edge trimming, joint finishing, wastage, accessories, cleaning and protection, complete.Technical Specifications:Minimum weight: 450–500 gsmHeavy-duty, washable and scrubbable finishStain-, impact- and abrasion-resistant, suitable for hospitality and commercial interiorsExcellent colour retention and light fastnessFire rating: ASTM E84 Class A / EN 13501 B-s2,d0 or equivalentAccurately matched patterns with neat, concealed jointsFinished surface free from bubbles, wrinkles, lifting edges, open joints and adhesive marksApproved Makes: Vescom / Arte Contract / Omexco / Muraspec / Texam Home / Glamora / York Contract / Phillip Jeffries / Asian Paints Nilaya / Marshalls / equivalent approved premium brand. (Base Rate:- 4750/sqm) Outdoor-grade WPC (Wood Plastic Composite) decking or heavy-duty anti-skid vitrified tiles over prepared base.
105Providing and fixing exterior-grade UV-stabilised, anti-skid, co-extruded WPC deck flooring, comprising:1.Minimum 25 mm thick co-extruded WPC decking boards, exterior grade, weather-resistant, termite-proof and fade-resistant, in approved wood shade and texture.2.Heavy-duty joist framework of Hot-dip galvanised steel joists of minimum 40 x 25 x 2.0 mm section with zinc coating not less than 80 micronsinstalled at maximum 300–400 mm c/c spacing as recommended by the manufacturer.3.Adjustable HDPE/PP pedestal supports or levelling pads to achieve approximately 100 mm overall build-up above finished floor level, complete with shims, spacers and fixing accessories.4.Concealed stainless steel (SS 304 grade) clips, screws, fasteners, starter clips, expansion gaps, edge trims and finishing profiles as required.5.Proper alignment, levelling and provision of drainage slope, including cutting and fitting around columns, edges and other obstructions.All labour, materials, tools, wastage, transportation, handling and incidental works complete as per manufacturer's specifications and Engineer-in-Charge's approval.Approved makes for WPC decking: NewTechWood, Alstone, Ecoste, Renox, FunderMax WPC, or equivalent approved make. Expansion Gaps: A longitudinal gap of 3mm must be maintained at all butt joints and a 10mm gap at the perimeter where the deck meets the structural steel portal columns.Hidden Fasteners: No screws should be visible on the top surface of the deck. Only the side-groove clipping system should be utilized.Air Circulation: Ensure the sides of the pavilion allow for some air movement under the deck to prevent moisture buildup and potential warping of the composite material.
106Providing and fixing minimal-joint laminated safety-glass roofing over pergola steel framework, comprising:Glass specification19.52 mm thick laminated safety glass consisting of:10 mm fully toughened, heat-soak-tested, low-iron glass.Approved ivory ceramic-frit pattern on the protected laminated face.1.52 mm ionoplast structural interlayer.8 mm heat-strengthened clear glass.Factory cutting, edge polishing, heat treatment and lamination.Glass panels to be of maximum practical size as per approved structural and fabrication drawings.System shall be certified as suitable for the adopted roof slope of 1:25. Fixing systemProprietary mechanically retained aluminium pressure-plate glazing system fixed over RHS rafters and transoms.Continuous aluminium base profiles with integral drainage channels.EPDM isolation strip between aluminium profiles and painted steel.Upper and lower EPDM glazing gaskets.Neoprene/EPDM setting blocks and concealed anti-creep stops at the lower edge.Aluminium pressure plates fixed with SS 304 screws.Snap-on aluminium cover caps in approved exterior finish.Nominal external sightline: 50 mm; up to 56 mm only where structurally required. Individual glass panels shall remain independently supported and shall not have direct contact with steel or aluminium.Neutral-cure, UV-resistant weatherproof silicone compatible with glass, frit, ionoplast interlayer, EPDM and aluminium.Approved makesGlass: Saint-Gobain / AIS / equivalent approved manufacturer.Ionoplast interlayer: Kuraray SentryGlas or approved equivalent.Weather sealant: DOWSIL 791 or 795 / Sika Sikasil WS-605 S / equivalent approved neutral-cure façade silicone.EPDM gaskets, setting blocks, pressure plates and fasteners: Original components supplied or approved by the selected glazing-system manufacture
107Aluminium Box GutterProviding and fixing 2 mm thick powder-coated aluminium box gutter, approximately 200 × 150 mm, along the low edge of the glass roof, including brackets, cleats, end caps, outlets, expansion joints, sealant, scaffolding and all incidental works complete.
108Aluminium Rainwater DownpipeProviding and fixing 100 mm diameter or equivalent rectangular powder-coated aluminium rainwater downpipe, including clamps, bends, offsets, shoes, connection to nearest drain, scaffolding and all incidental works complete.
109Providing and fixing concealed exterior-grade linear LED strip lighting for pergola glass roof illumination, comprising:24V DC COB/high-density LED strip with continuous dot-free light output.Power consumption: 9.6–12 W per running metre.Colour temperature: 3000K warm white, CRI ≥ 90.Minimum protection rating: IP67.Mounted in concealed matte-black aluminium profile with UV-stabilised opal diffuser, fixed to the steel pergola frame and directed upward towards the glass roof.Fixing only to structural steel members without affecting glass, pressure plates, gaskets or drainage profiles.Complete with end caps, connectors, IP67 glands, waterproof joints and mounting accessories. Dimmable 24V constant-voltage LED drivers with minimum 20% spare capacity in accessible IP65 weatherproof enclosures.FRLS copper wiring, earthing, UV-resistant conduits, junction boxes and control cabling.Including master dimmer, astronomical timer/photocell, MCB, surge protection, testing and commissioning.Submission of night-time lighting mock-up for approval before final installation.Including all materials, labour, transportation, scaffolding and incidental works complete.Approved makes for LED strip: LEDVANCE / Philips-Signify / Wipro Lighting / Havells Professional / equivalent approved make.Approved makes for drivers: Mean Well / Philips Xitanium / Tridonic / LEDVANCE-OSRAM / equivalent approved make.
110Providing and placing custom-fabricated commercial kitchen island counter. The top is to be made of 16 SWG (Standard Wire Gauge) / 1.5mm thick SS 304 grade stainless steel sheet. The top must be sound-deadened from underneath using 19mm waterproof marine ply or high-density sound-absorbing mastic. Framework and legs to be constructed using 38x38mm or 50x50mm SS 304 hollow square pipes (16 SWG), complete with SS adjustable bullet feet for leveling. All joints to be argon welded, ground flush, and finished to a seamless satin/matte polishApproved makes :Jindal Stainless Steel, SAIL or equivalent approved make.
111Wall-Mounted / Perimeter Prep Counters:- Providing and placing custom-fabricated commercial kitchen wall counters. Top made of 16 SWG / 1.5mm thick SS 304 grade stainless steel sheet, featuring an integrated 150mm high rear splashback (upstand). The top must be sound-deadened from underneath. Framework and legs to be constructed using 38x38mm SS 304 hollow square pipes (16 SWG) with adjustable bullet feet. Includes one/two standard SS under-shelves. All joints argon welded and finished to a seamless satin/matte polish.Approved makes : Jindal Stainless Steel, SAIL: Sealant : Dow Corning or equivalent equivalent approved make. the top edge of the SS splashback must be sealed to the wall tiles using a food-grade, anti-fungal silicone sealant ). to water from seeping down the back of the wall.
112Providing, installing, and commissioning a custom fabricated, extended-length 3-compartment stainless steel commercial sink workstation as a complete composite unit, including all integrated sanitary fixtures, drainboards, and waste manifolds.Specification:Fabricated entirely from 304-grade stainless steel. Overall extended dimensions approximately 3000mm (L) x 600mm (W) x 850mm (H) + 150mm splashback. The composite unit shall include:The Structure: Three (3) fully welded, seamless sink bowls (internal dims approx. 500mm x 500mm x 350mm deep). Constructed with 16 SWG (1.5mm) thick SS 304 sheet for the top/bowls and 18 SWG for the under-structure. Supported on 40x40mm SS square tubular legs with adjustable bullet feet. Drainboards: Two (2) extended corrugated drainboards (approx. 750mm each for left and right), sloped toward the bowls.Faucets & Sprayers: One (1) heavy-duty commercial deck/wall-mounted spring-action pre-rinse sprayer unit, and one (1) heavy-duty CP brass swing nozzle faucet (to reach rinse and sanitize bowls).Drainage Fittings: Three (3) heavy-duty brass waste couplings with lever-operated drain valves (waste chutes), interconnected via a PVC/UPVC waste manifold discharging into a single bottle trap/floor drain.Installation: Inclusive of all sealants, fasteners, core cutting, and connection to the main water supply and drainage lines within a 1-meter radius.
113Vegetable Preparation & Wash Sink:- Providing, installing, and commissioning a custom fabricated, composite 2-compartment stainless steel Vegetable Prep and Wash Workstation, including integrated cutting zone and all sanitary fixtures.Specification:Fabricated entirely from food-grade 304 stainless steel. Overall dimensions approximately 2400mm (L) x 600mm (W) x 850mm (H) + 150mm rear splashback. The composite unit shall include:The Structure: Two (2) fully welded, seamless sink bowls (internal dims approx. 450mm x 450mm x 300mm deep) positioned on the left/center. Constructed with heavy-duty 16 SWG (1.5mm) thick SS 304 sheet for the top and bowls, and 18 SWG for the under-structure. Supported on 40x40mm SS square tubular legs with adjustable bullet feet and cross-bracing. Drainboard & Prep Zone: One (1) sloped corrugated drainboard for receiving unwashed veg, and one (1) flat prep zone on the clean side featuring a recessed, removable High-Density Polyethylene (HDPE) food-grade cutting board (approx. 600mm x 400mm) for chopping.Faucets & Sprayers: One (1) commercial deck-mounted pre-rinse spring sprayer (for removing heavy soil/mud from roots/leaves) and one (1) heavy-duty CP brass swing nozzle faucet.Drainage Fittings: Two (2) heavy-duty brass waste couplings with lever-operated drain valves, interconnected via a UPVC waste manifold discharging into a single bottle trap/floor drain.Installation: Inclusive of all sealants, fasteners, and connection to the main water supply and drainage lines within a 1-meter radius.
114Providing and fixing factory-fabricated, heavy-duty 4-tier storage rack suitable for commercial kitchens (grocery, utensils, and vegetable storage). The rack shelves shall be manufactured from 18 SWG (1.2mm) thick food-grade Stainless Steel (SS 304) sheet, with edges properly turned, hemmed, and reinforced with SS channels for structural rigidity to prevent sagging under heavy loads. The upright pillars shall be made of 38mm x 38mm square or 1.5\\" diameter round SS 304 pipes (16 SWG), complete with adjustable heavy-duty SS/nylon bullet feet for floor leveling. All joints shall be seamlessly argon arc welded, ground smooth, and polished to a uniform No. 4 matte finish.Standard Dimensions: 1200mm (L) x 500mm (D) x 1800mm (H).Approved makes :Jindal Stainless Steel, SAIL or equivalent approved make.
115Providing and supplying a heavy-duty, factory-fabricated 3-tier Stainless Steel (SS) utility trolley suitable for moving heavy utensils and kitchenware. The trolley shelves shall be constructed from 18 SWG (1.2mm) thick food-grade SS 304 sheet, featuring die-pressed borders and reinforced underneath with sound-deadening materials and SS channels for load-bearing capacity. The main tubular framework and push handles shall be made of 25mm (1\\") diameter SS 304 round pipes (16 SWG). The unit shall be mounted on 4 nos. of heavy-duty, noise-free 100mm (4\\") polyurethane swivel castor wheels (2 with foot-operated brakes). All welded joints shall be seamlessly argon arc welded, ground smooth, and polished to a uniform No. 4 matte finish.Standard Dimensions: 900mm (L) x 500mm (W) x 850mm (H).Approved makes :Jindal Stainless Steel, SAIL or equivalent approved make.
116Counter-Based Commercial Deep Fat Fryer:- Providing, supplying, installing, testing and commissioning counter-based commercial electric double tank deep-fat fryer unit, fabricated from food-grade SS 304, comprising minimum 1.2 mm thick stainless-steel working top and frying tank, SS body panels, supporting framework and enclosed/open base below.The fryer shall be complete with twin frying baskets having heat-resistant handles, oil drain valve, removable crumb tray, splash guard, adjustable thermostatic temperature control, high-temperature safety cut-out, pilot/indicator lamps, heavy-duty electrical heating elements, and adjustable stainless-steel legs with nylon bullet feet.The unit shall include all internal wiring, controls, switches, contactors, thermostats, power cable, plug top/isolator connection, earthing arrangement, transportation, positioning, installation, testing and commissioning, complete as per approved shop drawings and manufacturer’s specifications. Indicative specifications:Frying capacity: 16 litresConstruction: SS 304 food-contact surfacesFrying baskets: Two numbersTemperature range: Approximately 50°C to 200°CElectrical load: Approximately 6–9 kWPower supply: 230/415 V, 50 Hz AC, as requiredOverall size: Approximately 600–900 mm wide × 700–750 mm deep × 850 mm highOperating type: ElectricComplete with one-year comprehensive warranty
117SITC of Walk-In Cold Room (Chiller) for Vegetable/Dairy Storage (+2°C to +8°C).:- Specification:Overall approximate external dimensions: 3000mm (L) x 3000mm (W) x 2400mm (H).Panels: Walls, ceiling, and floor constructed of 80mm thick High-Density Polyurethane Foam (PUF) panels (density 40±2 kg/m³). Inner and outer skins of 0.5mm thick PPGI (Pre-Painted Galvanized Iron). Interlocking cam-lock system.Flooring: 80mm PUF floor panels overlaid with 2mm thick Aluminum Checker Plate with marine ply backing for trolley movement. Door: One (1) PUF insulated flush door (900mm x 1900mm clear opening) with heavy-duty hinges, POSI-seal latch, internal glow-in-the-dark safety release, and internal PVC strip curtains.Refrigeration System: 1.5 HP to 2.0 HP Split-type refrigeration unit (+2°C). Includes one (1) air-cooled outdoor condensing unit (hermetic scroll/reciprocating compressor) and one (1) ceiling-suspended, low-velocity indoor evaporator unit.Controls & Accessories: Microprocessor-based digital temperature controller, vapour-proof LED lighting, interconnecting copper piping (up to 5 meters) with nitrile insulation, and eco-friendly refrigerant charge.
118Providing and placing 2-Door Vertical Reach-In Commercial Freezer for raw meat storage (-18°C to -22°C).Specification:Capacity: Approx. 500 to 600 Liters.Dimensions: MIN. 700mm (W) x 800mm (D) x 2000mm (H).Construction: Interior and exterior constructed of food-grade 304 Stainless Steel. CFC-free high-density polyurethane insulation. Doors: Two (2) solid SS half-doors (top and bottom) with heavy-duty hinges, magnetic gaskets, integrated handles, and door frame heaters (to prevent freezing shut). Lockable.Cooling System: Ventilated (fan-forced) cooling, maintaining -18°C to -22°C. Auto-defrost system with heated drain pan. Digital microprocessor temperature controller.Internals: Minimum three (3) adjustable PVC-coated or stainless steel wire shelves, compatible with GN 2/1 pans.Mobility: Mounted on heavy-duty lockable castors.
119FOH Open Display Shelving/Custom Industrial Open Shelving Unit Providing and fixing custom-fabricated, wall-mounted open display shelving.Structural Framework: Fabricated from 25 mm x 25 mm (1-inch) heavy-gauge Mild Steel (MS) hollow square tubes. All welding joints must be ground perfectly smooth (seamless).Metal Finish: Finished with anti-rust epoxy primer and 2 coats of Matte Black Powder Coating (spray paint is prohibited as it chips easily).Wooden Shelves: Minimum 25 mm thick premium BWP blockboard finished with natural wood veneer (to match FOH columns) Finished with 3 coats of clear Matte Acrylic PU Polish.Concealed Lighting: The bottom face of the wooden shelves must have a factory-routed 15mm groove to flush-mount an aluminum LED profile strip. 1. For Fixing diamond-tipped tile hole-saw bit on a low-speed rotary drill should be used instead of standard masonry hammer drill to avoid breakage of Brick tiles.2. Concealed Fasteners: The MS frame should be designed with welded anchor plates that sit flush against the wall. The SS anchor bolts should be hidden behind the wooden planks (to ensure floating and clean look )3. The Lighting Wire Path: The electrician must coordinate with the fabricator to pull the low-voltage wires for the LED strips straight out of the wall through the black MS square tubes (to ensure no visible wires)
120Foundation Earthwork: Earthwork in excavation by mechanical/manual means in foundation trenches, including dressing of sides and ramming of bottoms. Spec: excavating the two isolated pits ( 450x450x600mm) in the road as pre drawing to house the heavy RCC pedestals for the boom barriers).
121Pedestal Concrete: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing, and reinforcement - M-25 Grade Design Mix. Spec: To cast the rock-solid concrete pedestals that will absorb the high-torque twisting forces of the barrier motors operating at sub-2-second speeds).
122Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.
123Water Bound Macadem
124Bituminous portion
125Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
126Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
127Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
128Group C
129Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1302 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1312 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1322 X 4 sq. mm + 1 X 4 sq. mm earth wire
1332 X 6 sq. mm + 1 X 6 sq. mm earth wire
1344 X 6 sq. mm + 2 X 6 sq. mm earth wire
1354 X 10 sq. mm + 2 X 6 sq. mm earth wire
1364 X 16 sq. mm + 2 X 6 sq. mm earth wire
137Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top as directed by Engineer-Incharge ,complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
13870 sqmm 3.5 core
13995 sqmm 3.5 core
140Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
1413.5 X 70 sqmm. (45mm)
1423.5 X 95 sqmm. (45mm)
143Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
144Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
145Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 5/6 amps switch
146Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 3 pin 5/6 amp socket outlet
147Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 6 pin 15/16 amp socket outlet
148TV antenna socket outlet
149Telephone socket outlet
150Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C. Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg 1 Run of cable
151Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
152Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
153Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
15420 mm Dia
15525 mm Dia
156Dry Zones (FOH Counter & Dry Prep): 16A and 32A heavy-duty modular sockets
157Wet Zones (Scullery, Meat Prep, Island): IP65-Rated Waterproof/Splashproof industrial sockets
158For the espresso machine and POS (Point of Sale) billing systems, provide grommet holes in the countertop and mount the actual power sockets inside the wooden cabinets below the counter
159Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. Make: Wire: Make: Havells, Ploycab, KEI, Conduit: AKG, Supreme, Precision
160Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
16175 mm X 75 mm X 60 mm deep
162200 mm X 125 mm X 60 mm deep
163Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
164Supplying and drawing 1 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
165Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C. Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg 1 Run of cable
166Supply & fixing of following white RJ 45 cat 6 data outlet / information outlet ETL verified to meet exceed TIA / ETA (only for estimation)
167Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
168Supplying & Laying DWC Pipe: Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. direct in ground, including earth work in excavation and refilling the trench etc. as required. 90 mm dia
169Brush Less DIrect Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
1701200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
171Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.
172Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
173LED Down lighter (COB Type) (System lumen efficacy ≥ 105 < 120lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector.
17412 - 15 watt
175LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
17636 watt
177Supplying, installation, testing & commissioning of Hanging light complete with all accessories including connections etc. as required.
178Supplying, installation, testing & commissioning of LED Spot light complete with all accessories including connections etc. as required.
179Supply, Installation ,Testing, Commissioning of wall lamps per fitting, complete with all accessories including connections etc. as required.
180Providing, supplying, installing, testing and commissioning of Automatic Sensor Operated Hand Dryer of approved make, wall mounted type, complete with ABS/Stainless Steel body, infrared sensor, universal motor, heating element, power cord, mounting accessories, fixing screws, suitable for operation on 230V, 50Hz AC supply, having air velocity not less than 90 m/s, drying time not exceeding 15–20 seconds, protection class IPX1 or better, complete as required and as directed by the Engineer-in-Charge.
181Supply of Mirror Light 10 Watt LED . complete in all respect (only for estimation)
182Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
183Upto 450 mm sweep
184Supply of exhaust fan 250mm (only for estimation)
185Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
186Supply of Wall Fan AC 230/250 Volts, 50 Hz 50w 1350 rpm including nuts, bolts, mounting frame and other accessorieswith connections etc. complete as required.-Make: Havells, Usha, Bajaj
187300 mm sweep.
188OUTDOOR UNIT (VRV/VRF)
189Supply, Installation,Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual seperate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building) For Cooling or Heating or Both
19014 HP to 22 HP
191INDOOR UNIT (VRV/VRF)
192Supply, Installation,Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor)
1932.6 TR
194Supply, Installation, Testing, and Commissioning (SITC) of Turnkey Commercial Kitchen Ventilation System for Kitchen Block (Approx. 115 Sqm, inclusive of Open FOH)Scope & SpecificationsProviding a complete exposed exhaust and make-up air system (balanced for 20% negative pressure). Scope includes all equipment, ducting, structural supports, and necessary masonry wall cut-outs with internal/external finishing, structural silicone weatherproofing, and GI weather cowls with bird screens.Exhaust Hoods: Heavy-duty SS 304 (Min 1.0mm) wall/island hoods featuring SS Baffle Filters (mesh strictly prohibited), pitched grease troughs with cups, and built-in vapor-proof LED lighting.Blowers (Outdoor Mounted):Central Exhaust: 6000 CFM SISW Centrifugal Blower (3-Phase) on heavy-duty rubber isolators.FOH Dedicated Exhaust: 1500 CFM Acoustic Inline Centrifugal Blower with ECM motor (Kruger/S&P/Systemair or eq.). Must be ducted completely independently to the exterior.
195Fresh Air Intake: 5000 CFM Tube Axial Blower with custom GI plenum, 50mm washable Aluminum Mesh Pre-Filters, VCDs, and powder-coated supply diffusers. Routing constraint: Fresh air supply diffusers must be restricted entirely to the enclosed BOH zones to prevent interference with the adjacent air-conditioned dining area.Ducting: Factory-fabricated GI sheet. Exhaust at Min 20 SWG; Fresh Air at Min 22 SWG. Joints lock-formed and sealed with fire-resistant structural silicone. Suspended via heavy-duty GI slotted angles and neoprene gaskets. GFC/AS built Drawing shall also be submitted for the same.(Note: Quantities exceeding the baseline 30 Rft of hoods and 180 Sqm of ducting as per approved GFC drawings shall be paid pro-rata based on this baseline valuation)
196Providing and fixing factory-fabricated galvanized iron (GI) sheet metal ducting for the Fresh Air (Make-Up Air) system. Thickness: 22 SWG. Joints lock-formed and sealed with structural silicone. Includes heavy-duty GI slotted angle ceiling supports, neoprene gaskets, manual Volume Control Dampers (VCDs) at branch take-offs, and extruded aluminum powder-coated supply air diffusers/grilles (4-way or linear slot) as per HVAC drawing.
197Exposed Inverter Cassette AC Units (FOR DRAIN= 25 mmRigid UPVC Drain Lines) 3 tonnes
198High-Velocity Air Curtains
199Supply, Installation, Testing and Commissioning of LED RGB/RGBWW/RG BNW/ RGBA/ RGBW (as per site requirement) Linear Profile / Wall Washer luminaire for Facade lighting with aluminium extruded/ Die Cast housing with inbuilt driver of following wattage as given below.The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, having the rotation degrees scale shall be provided. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage , over volatge protection, driver inbuilt surge protection of 4KV and external surge prootection (SPD) of 10 KV common mode/differential mode , Driver Efficiency>85%, EMI/EMC as per CISPR-15. There should be options of beam angles of 10/20/30/40/60, asymmetric degree.Luminaire should have efficacy of minimum 40 lm/W for RGB/RGBNW/RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors
200DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 24 V DC. Fixture shall be suitable to operate at an ambient temperature range of - -10°C to +50°C and shall have impact resistance of IK 07. Lifetime of complete luminaire (LED ,Driver , Electrical & control circuitary) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum size 1.5sqmm connection cables and accesories , Integral male/female water proof connectors of IP68 etc. as required.The successful bidder shall submit the following certifications/reports for approval beforesupplyof materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer,RoHS Compliance. Wattage per meter
201Pedestrian Bollards: Providing and fixing heavy-duty LED bollard lights along the pedestrian walkways and landscaped driveway edges.(Project Spec: Height strictly 800mm. Housing must be heavy-duty extruded aluminum with a die-cast top. Finish: Matte Anthracite Black. Rating strictly IP65 (Waterproof) and IK08 (Vandal Resistant). Light source to be concealed (indirect/anti-glare design) with a warm 3000K color temperature to safely guide traffic without sky-glow). Approved /make: K-Lite, Ligman, ERCO or equivalent approved.
2025-Way Emission Architectural Pillar Cubes: Providing and fixing surface-mounted, multi-directional LED wall lights centrally on the front faces of the main gate pillars.(Project Spec: Fixture MUST be a minimalist geometric cube. Housing strictly heavy-duty die-cast aluminum finished in Matte Anthracite Black PU. Rating strictly IP65. Light output must feature 5-way emission (Up, Down, Left, Right, and Front) using high-precision acrylic lenses to cast a sharp, defined starburst geometry across the Archi-Concrete finish. Color temperature: 3000K (Warm White)). Approved /make: Philips, K-Lite, Endo or equivalent approved.
203Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
20416 way, Double door
205Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)
2064 way (4 + 12), Double door
207Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: ABB, L&T,Legrand, Siemens
208Single pole
209Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
21040 amp
21163 amp
212Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
21363 amp
214Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2152 MP IP IR Outdoor Bullet Camera
216Supplying Installation Testing and Commissioning of 2MP Fixed Lens IP IR Outdoor Bullet Camera having following spcifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt Smart IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White BalanceAuto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723
2174) Wide Dynamic Range:- WDR (120db or more) 5) Digital Noise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable (Main stream: 2MP (1920 × 1080)@25/30 fps Sub streams minimum: 720P@25/30 fps). 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot. 9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
2182MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet Camera with 2.8/ 3.6mm fixed lens
219Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input,Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance,Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication
220RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc 3KVA
221Supply & installation of LED smart TV 42 Inch (only for estimation)
222Supply and Installation, testing, Commsioning of Automatic High-Speed Dual Boom Barrier System (Hardware): Providing, installing, and commissioning 2 Nos. high-speed boom barriers (opening time < 2 seconds) for a dual-lane (Entry/Exit) setup.(Project Spec: Cabinet to be factory powder-coated in Matte Black or Dark Anthracite to match the portal aesthetics. Standard orange/yellow is strictly prohibited. Boom arm to be a standard 3-Meter octagonal aluminum arm with integrated Red/Green LED light strips. System must feature anti-crush safety mechanisms and be fully compatible with external UHF/RFID FASTag readers and manual push-button override).Barrier Front Design rectangular Barrier Colour Silver/Grey Colour Vega Electromechanical Drive Mechanism Boom-Arm -4-6MTR Opening & Closing Time : 3-4 SecProtection Class : IP 54 Receiver LED illumination on boom armPush Button (Inclusive)Boom-Rest(Inclusive)Photo Cell ( Inclusive) (Approved make :- FAAC, ZKTeco, houston or approved equivalent )
223Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required.
224Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
225Providing & fixing 25 mm x 5 mm. copper strip on surface or in recess for connection etc. as required.
226Providing & fixing 6 SWG dia G.I. on surface or in recess for loop earthing as required.
227Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH each sealed maintenance free batteries -1 set.
228Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required
229Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
230Supplying, installation, testing & commissioning of addressable manual call point complete as required.
231Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required
232Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work
233Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along withsupply of all materials and labour for proper completion of work.
234Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
235Supplying, installation, testing & commissioning of 6 inches dia, 2 watts, 70/100 volts ceiling speaker complete as required.
236Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable Ethylene Propylene Runner (EPR) inshulation and LSZH inner bedding, steel wire armouring & FRLS outer sheath complete as required.
237Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole Basin mixer
238Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
239Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia
240Providing and fixing CP Brass 32mm/40mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
241Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete in all respect.
242Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
243Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
244Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore
245Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
246Providing & fixing storage type electric Hot water Geyser 15 Litre made out of heavy gauge steel jacket finished with rust proof baked-on glossy white enamel paint, inside glass lined heavy gauge copper tank, 25 mm thick polyurethane foam insulation, thermostatically controlled immersion heater with pilot neon lamp, replaceable magnesium anode bar, suitable for 8.0 bar maximum working pressure, cold water inlet and hot water outlet pipe, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. (Horizontal/Vertical) (only for estimation)
247Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms.
248Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. (a) 15mm nominal bore
249Blue Star 200L Cooling Storage Water Cooler SDLX200400B. Features :- Brand Name : Blue Star Refrigerant : R-22 Power Source : Electric Dimensions : 1120 x 750 x 1500 mm Voltage : 230 V Type of Product : Water Cooler
250Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 100 mm dia
251Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm dia
252Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler 110 mm
253Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Single tee with door 110x110x110 mm
254Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Single tee without door 110x110x110 mm
255Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110mm bend
256Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Shoe (Plain) 110mm shoe
257Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
258Making khurras 60x60 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
259Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion: 110 mm diameter.
260Providing and fixing 110 mm diameter UPVC pipe (Type A) as overflow scupper / rain water spout in parapet walls, cut to required length (typically 450mm to 600mm) and projecting a minimum of 150 mm beyond the exterior wall face. Includes making the hole in the brickwork and grouting it leak-proof with cement mortar 1:3 mixed with waterproofing compound.
261Providing and fixing factory-molded UPVC L-shaped corner roof drain / parapet scupper (110 mm diameter outlet) with a built-in ribbed flange for membrane bonding. Includes setting the drain flush into the concrete base/khurra, grouting with polymer-modified cement mortar, and connecting the outlet to the exterior downpipe or projecting it as a free-fall spout.
262Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof
263Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 110 mm dia. (only for estimation)
264Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Bend without door (45°) 110mm (only for estimation)
265Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Y' Fitting without door 110mm (only for estimation)
266Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Single Tee without door 110mm (only for estimation)
267Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Coupler 110mm (only for estimation)
268Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Clean Out Plug 110mm (only for estimation)
269Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin 40mm dia. Pipe (only for estimation)
270Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Elbow (90°) 40mm (only for estimation)
271Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Elbow (45°) 40mm (only for estimation)
272Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . T fitting 40mm (only for estimation)
273Supply and fixing of UPVC S.W.R. pipe Nahni Trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali.
274Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design:150 x 100 mm. size P type
275With Sewer bricks conforming to IS : 4885
276Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
277With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
278Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard designWith 20x20 mm square bar
279Commercial Stainless Steel Grease Trap (TO AVOID FAT COAGULATION ) (IN FOH, MEAT AREA, ISLAND COUNTER AND SCULLERY )Providing and installing a heavy-duty, multi-stage commercial grease interceptor (Grease Trap).Material: 100% Stainless Steel (SS 304), minimum 1.2 mm to 1.5 mm thickness to prevent corrosion from acidic food waste.CAPACITY : 400 mm X 400 mm X 400mmFeatures: Must include removable internal baffle plates, a solid food strainer basket, and an airtight, clamped lid with a neoprene gasket to seal in foul odors.Approved makes :ACO, KITCHENRAMA or EIC approved equivalent Placement: To be installed directly beneath or immediately adjacent to the primary dishwashing/pot-wash sink, before the wastewater enters the main floor drainage line.Accessibility: It must be easily accessible, so that staff can open the lid and scoop out the trapped fat blocks once a week.
28075 mm for secondary branch lines. 50 MM PIPES for commercial kitchen floor prohibhited as it will lead to clogging.
281Floor Catch Basins & Gratings Providing and fixing heavy-duty SS 304 floor drain catch basins ( 250 mm x 250 mm).Features: Must include an internal removable bucket strainer (to catch rice, vegetable peels, and solid debris before it hits the pipes) and a deep water-seal cockroach trap.Load Rating: The top grating must be heavy-gauge and anti-bend, capable of supporting the weight of a loaded kitchen trolley rolling over it.Approved makes :- Jayna, Nirali, or custom-fabricated SS 304 or EIC approved Equivalent 1. 45-degree Y-branches (Shoe bends) with clean-out plugs for every single turn and junction in the underground drainage lines. (90 degree bends) are prohibhited.2. The slope gradient should be 1:60
282Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm dia nominal bore
283Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 20 mm dia nominal bore
284Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 25 mm dia nominal bore
285Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 32 mm dia nominal bore
286Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20mm dia nominal bore
287Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25mm dia nominal bore
288Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore
289Providing and Placing on Terrace (at all floor levels) Polyethylene Water Storage Tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
290Capacity 15000 litre Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57439724
AUTHORITY Government Departments
TENDER VALUE 2.33 Crore
LAST DATE 05-10-2026
Authority
Authority Name Ministry Of Road Transport And Highways
Work Description Tender for Renovation Of Cafeteria, Construction Of Pergola And Redesign Of Reception Gate At Iahe C Us, Noida
Basic Detail
Tender No IAHE/Admin./22/CAFGAT/2026-27
Bidding Type Tender
Location
City Gautam Buddha Nagar
State Uttar Pradesh
Key Dates
Publish Date 10 Sep 2026
Submission Date 05 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 2.33 Crore
Tender Fee Ref. Documents
EMD 4.68 Lakhs
Exemption Available
Document List
BOQ_972675.xls
d7b5e37a-7c00-4642-9803-4c10db9459df.html
Tendernotice_1 (10).pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_972675.xls

html

d7b5e37a-7c00-4642-9803-4c10db9459df.html

pdf

Tendernotice_1 (10).pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders