Educational and Research Institute Boards / Undertakings / PSU Closing in 12 days TDR #57439714

Tender For Replacement Of Old Package Units (8.75 Tr X 3 ) Installed At Data Centre With New Ahu Units, Pgimer, Chandigarh.

Issued by Boards / Undertakings / PSU · Chandigarh, Chandigarh
Tender Value
17.61 Lakhs
Estimated cost
Bid Submission
22 Sep 2026
12 days left
EMD
35220
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Old Package Units (8.75 Tr X 3 ) Installed At Data Centre With New Ahu Units, Pgimer, Chandigarh.

BOQ

Name of Work:- Replacement of old package units (8.75 TR X 3 ) installed at Data centre with new AHU units, PGIMER, Chandigarh.
Sl. No. Item Description
1Air Handling unit
2Supply, installation, testing and commissioning of Floor mounted Double skin Air Handling units having precoated/preplasticised GI sheet of 0.8mm on outside & 1.00 mm thick plain Aluminium sheet intside. The minimum panel thickness should be 25+/-2 mm having CFC free PUF ( 40 +/- 2 kg density) injected between the panels with thermal break profile. Filter section with Pre filter & Fine filter. Cooling coil section with combination of 4(w) + 4(s) rows rows coils and atleast 400mm gap between the coils. SS Coil casing, SS Drain Pan with nitrile rubber insulation, aluminium fins (11-13 FPI) & copper tube thickness as per ODU manufacturer standard. Fan section with backward curved fan, energy efficient IE3, TEFC motor(VFD Compatible), V-belt & drive set as per the detail specifications of the DNIT. 6000 CFM (65 mmwg st. press.)
3SITC of 8.5 TR outdoor units for DX coil AHU complete as required.
4Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for HVAC system, complete with fittings ,with suitable adjustable ring type hanger supports, jointing / brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves section so specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
528.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm or as per OEM standard with 19 mm thick insulation
615.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm or as per OEM standard with 19 mm thick insulation.
7Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
822 GUAGE (0.80 mm)
924 GUAGE (0.63 mm)
10Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
1119 mm
12P/F Flexible double canvas connection water proof between indoor units and supply air duct.
13SITC of duly painted MS stand.
14Supply installation testing and commisioning of GI volume control damper complete with neoprene rubber gaskets,nuts,bolts,screw linkages,flanges etc as per specifactions.
15Supplying & Fixing of powder coated extruded aluminium Suplly Air grills with aluminium volume control damper as per specifications.
16Supply fixing of powder coated extruded aluminium return Air grills with louvers but without volume control Damper complete as required.
17Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control Dampers with anti smudge ring & removable core.
18Supply, fixing testing commissioning of return air diffusers of powder coated aluminium without volume control Dampers anti smudge ring & removable core.
19P/F Heater Bank for winter heating comprising of 12 kw capacity having arrangement for on/off in stages with thermostat, geyserstat contactor, interconnected wirting control panel etc.
20Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
21Fire damper
22Actuator
23Supply, Installation, Testing and Commissioning of Electrical Panel Cubical Type, dust and vermin proof ingress protection, IP-42 Floor Mounted Switchboard with Hinged Lockable Doors fabricated out of 14/16 SWG CRCA Sheet with Powder Coating through 7 tank process with all accessories live parts shrouded and busbars insulated with heat shrinkable sleeves including solid / flexible connections, earthing etc., having 3mm thickness Gland Plate. LT Panel should have withstand fault levet of equal to 50 KA for 1 second. Fittted with gaskets, Panel comprising of the following:-
24PANEL No.-1
25INCOMER FEEDER
26MCCB FP 100A. 25KA. TM BASED WITH O/L & S/C PROTECTION (1)
27SPREADER SET (1)
28EXTENDED ROTARY HANDLE (1)
29R,Y PHASE INDICATING LAMP (2)
30B PHASE INDICATING LAMP (1)
316A. SP CONTROL MCB (4)
32DIGITAL AMMETER CL1.0 WITH ASS (1)
33DIGITAL VOLMETER CL1.0 WITH VSS (1)
34CT SHORTING LINK (3)
35NEUTRAL LINK (1)
36OUTGOING FEEDER
373.7KW DOL STR (FOR AHU MOTOR)
38MCB TP 32A. 10KA. C CURVE TYPE (1)
3925A. TP POWER CONTACTOR. (1)
40ADDD ON BLOCK 2NO+2NC (1)
419-15A. THERMAL OVERLOAD RELAY (1)
42START STOP PUSH BUTTON (2)
43ON/OFF INDICATING LAMP (2)
44A/M SELECTOR SWITCH (1)
456A. SP CONTROL MCB (1)
46SPP RELAY (1)
47PLA RELAY (1)
48NEUTRAL LINK (1)
4912KW HEATER BANK- 1NO.
50MCB FP 32A. 10KA. C CURVE TYPE (1)
5125A. TP POWER CONTACTOR (1)
52ON INDICATING LAMP (1)
536A. SP CONTROL MCB (1)
548.5 TR OUTDOOR COMPRESSOR UNIT - 4NOS.
55MCB FP 63A. 10KA. C CURVE TYPE (4)
56RCCB FP 63A. 300MA. (4)
57ENCLOSURE & ACCESSORIES
58FABRICATION IN 1.6/2.0MM CRCA SHEET POWDER COATING IN SIEMENS GRAY SHADE, CABLE ENTRY WILL BE TOP & BOTTOM SUITABLE FOR CABLE ,LOCK, RUBBER GASKET, HARDWARE ETC.
59BUS BAR & HARDWARE
60100A. FP AL. MAIN BUS BAR,LOAD WISE SUB FEEDER BUS BAR COLOUR COATED HEAT SHRINK BUS BAR SLEAVE NUT-BOLT,WASHER
61,HARDWARE ETC.
62WIRING & ACCESSORIES
63POWER & CONTROL WIRING WILL BE (ISI 1100V) FLAME RETARDENT LOW SMOKE PVC SINGLE CORE COPPER WIRE,COPPER LUGGS, PVC SLEEVE, FERRULES, NUMBERS, HARDWARE & LABOUR ETC.
64Supply & laying of XLPE PVC insulated armoured copper cabling 4 core 10 sq mm . complete in all respect as per speification and direction of engineer incharge.
65Supply & laying of XLPE PVC insulated copper wire 4 core 1.5 sq mm armoured complete in all respect as per speification and direction of engineer incharge.
66Supplying and laying 25 mm x 5 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm.)
67Providing & fixing 6 SWG dia. GI wire on surface or in recess for loop earthing as required.
68Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
69300 mm width x 50mm depth x 1.6 mm thickness
70150 mm width x 50mm depth x 1.6 mm thickness.
71SITC of 40 mm GI drain pipe complete with insulation, accessories i.e. bend, union, reducer and teflon tape etc. complete as required.
72Minor civil work including opening of walls, cutting, chieseling etc. complete in all respect.
73Buyback of old dismantled package AC units, ducts, panel,cable,ODU, Copper pipe, MS Stand etc. complete in all respect. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57439714
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 17.61 Lakhs
LAST DATE 22-09-2026
Authority
Authority Name Post Graduate Institute Of Medical Education And Research
Work Description Tender for Replacement Of Old Package Units (8.75 Tr X 3 ) Installed At Data Centre With New Ahu Units, Pgimer, Chandigarh.
Basic Detail
Tender No PGI/Engg/RAC/2026/323
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 10 Sep 2026
Submission Date 22 Sep 2026
Open Date 23 Sep 2026
Finance
Tender Value 17.61 Lakhs
Tender Fee Ref. Documents
EMD 35220
Exemption Not Available
Document List
9134fe58-e87f-4308-86fa-36bf49ae3e75.html
BOQ_972689.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Sep 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Sep 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

9134fe58-e87f-4308-86fa-36bf49ae3e75.html

xls

BOQ_972689.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail