Tender For Replacement Of Old Package Units (8.75 Tr X 3 ) Installed At Data Centre With New Ahu Units, Pgimer, Chandigarh.
Tender Value
17.61 Lakhs
Estimated cost
Bid Submission
22 Sep 2026
12 days left
EMD
35220
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of Old Package Units (8.75 Tr X 3 ) Installed At Data Centre With New Ahu Units, Pgimer, Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | Air Handling unit |
| 2 | Supply, installation, testing and commissioning of Floor mounted Double skin Air Handling units having precoated/preplasticised GI sheet of 0.8mm on outside & 1.00 mm thick plain Aluminium sheet intside. The minimum panel thickness should be 25+/-2 mm having CFC free PUF ( 40 +/- 2 kg density) injected between the panels with thermal break profile. Filter section with Pre filter & Fine filter. Cooling coil section with combination of 4(w) + 4(s) rows rows coils and atleast 400mm gap between the coils. SS Coil casing, SS Drain Pan with nitrile rubber insulation, aluminium fins (11-13 FPI) & copper tube thickness as per ODU manufacturer standard. Fan section with backward curved fan, energy efficient IE3, TEFC motor(VFD Compatible), V-belt & drive set as per the detail specifications of the DNIT. 6000 CFM (65 mmwg st. press.) |
| 3 | SITC of 8.5 TR outdoor units for DX coil AHU complete as required. |
| 4 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for HVAC system, complete with fittings ,with suitable adjustable ring type hanger supports, jointing / brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves section so specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : |
| 5 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm or as per OEM standard with 19 mm thick insulation |
| 6 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm or as per OEM standard with 19 mm thick insulation. |
| 7 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 8 | 22 GUAGE (0.80 mm) |
| 9 | 24 GUAGE (0.63 mm) |
| 10 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. |
| 11 | 19 mm |
| 12 | P/F Flexible double canvas connection water proof between indoor units and supply air duct. |
| 13 | SITC of duly painted MS stand. |
| 14 | Supply installation testing and commisioning of GI volume control damper complete with neoprene rubber gaskets,nuts,bolts,screw linkages,flanges etc as per specifactions. |
| 15 | Supplying & Fixing of powder coated extruded aluminium Suplly Air grills with aluminium volume control damper as per specifications. |
| 16 | Supply fixing of powder coated extruded aluminium return Air grills with louvers but without volume control Damper complete as required. |
| 17 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control Dampers with anti smudge ring & removable core. |
| 18 | Supply, fixing testing commissioning of return air diffusers of powder coated aluminium without volume control Dampers anti smudge ring & removable core. |
| 19 | P/F Heater Bank for winter heating comprising of 12 kw capacity having arrangement for on/off in stages with thermostat, geyserstat contactor, interconnected wirting control panel etc. |
| 20 | Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. |
| 21 | Fire damper |
| 22 | Actuator |
| 23 | Supply, Installation, Testing and Commissioning of Electrical Panel Cubical Type, dust and vermin proof ingress protection, IP-42 Floor Mounted Switchboard with Hinged Lockable Doors fabricated out of 14/16 SWG CRCA Sheet with Powder Coating through 7 tank process with all accessories live parts shrouded and busbars insulated with heat shrinkable sleeves including solid / flexible connections, earthing etc., having 3mm thickness Gland Plate. LT Panel should have withstand fault levet of equal to 50 KA for 1 second. Fittted with gaskets, Panel comprising of the following:- |
| 24 | PANEL No.-1 |
| 25 | INCOMER FEEDER |
| 26 | MCCB FP 100A. 25KA. TM BASED WITH O/L & S/C PROTECTION (1) |
| 27 | SPREADER SET (1) |
| 28 | EXTENDED ROTARY HANDLE (1) |
| 29 | R,Y PHASE INDICATING LAMP (2) |
| 30 | B PHASE INDICATING LAMP (1) |
| 31 | 6A. SP CONTROL MCB (4) |
| 32 | DIGITAL AMMETER CL1.0 WITH ASS (1) |
| 33 | DIGITAL VOLMETER CL1.0 WITH VSS (1) |
| 34 | CT SHORTING LINK (3) |
| 35 | NEUTRAL LINK (1) |
| 36 | OUTGOING FEEDER |
| 37 | 3.7KW DOL STR (FOR AHU MOTOR) |
| 38 | MCB TP 32A. 10KA. C CURVE TYPE (1) |
| 39 | 25A. TP POWER CONTACTOR. (1) |
| 40 | ADDD ON BLOCK 2NO+2NC (1) |
| 41 | 9-15A. THERMAL OVERLOAD RELAY (1) |
| 42 | START STOP PUSH BUTTON (2) |
| 43 | ON/OFF INDICATING LAMP (2) |
| 44 | A/M SELECTOR SWITCH (1) |
| 45 | 6A. SP CONTROL MCB (1) |
| 46 | SPP RELAY (1) |
| 47 | PLA RELAY (1) |
| 48 | NEUTRAL LINK (1) |
| 49 | 12KW HEATER BANK- 1NO. |
| 50 | MCB FP 32A. 10KA. C CURVE TYPE (1) |
| 51 | 25A. TP POWER CONTACTOR (1) |
| 52 | ON INDICATING LAMP (1) |
| 53 | 6A. SP CONTROL MCB (1) |
| 54 | 8.5 TR OUTDOOR COMPRESSOR UNIT - 4NOS. |
| 55 | MCB FP 63A. 10KA. C CURVE TYPE (4) |
| 56 | RCCB FP 63A. 300MA. (4) |
| 57 | ENCLOSURE & ACCESSORIES |
| 58 | FABRICATION IN 1.6/2.0MM CRCA SHEET POWDER COATING IN SIEMENS GRAY SHADE, CABLE ENTRY WILL BE TOP & BOTTOM SUITABLE FOR CABLE ,LOCK, RUBBER GASKET, HARDWARE ETC. |
| 59 | BUS BAR & HARDWARE |
| 60 | 100A. FP AL. MAIN BUS BAR,LOAD WISE SUB FEEDER BUS BAR COLOUR COATED HEAT SHRINK BUS BAR SLEAVE NUT-BOLT,WASHER |
| 61 | ,HARDWARE ETC. |
| 62 | WIRING & ACCESSORIES |
| 63 | POWER & CONTROL WIRING WILL BE (ISI 1100V) FLAME RETARDENT LOW SMOKE PVC SINGLE CORE COPPER WIRE,COPPER LUGGS, PVC SLEEVE, FERRULES, NUMBERS, HARDWARE & LABOUR ETC. |
| 64 | Supply & laying of XLPE PVC insulated armoured copper cabling 4 core 10 sq mm . complete in all respect as per speification and direction of engineer incharge. |
| 65 | Supply & laying of XLPE PVC insulated copper wire 4 core 1.5 sq mm armoured complete in all respect as per speification and direction of engineer incharge. |
| 66 | Supplying and laying 25 mm x 5 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm.) |
| 67 | Providing & fixing 6 SWG dia. GI wire on surface or in recess for loop earthing as required. |
| 68 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 69 | 300 mm width x 50mm depth x 1.6 mm thickness |
| 70 | 150 mm width x 50mm depth x 1.6 mm thickness. |
| 71 | SITC of 40 mm GI drain pipe complete with insulation, accessories i.e. bend, union, reducer and teflon tape etc. complete as required. |
| 72 | Minor civil work including opening of walls, cutting, chieseling etc. complete in all respect. |
| 73 | Buyback of old dismantled package AC units, ducts, panel,cable,ODU, Copper pipe, MS Stand etc. complete in all respect. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 10, 2026
11:30 IST
Tender Published
Tender notice published.
TodaySep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender