Tender For Repair & Renovation Of Proposed Kaushal Bhawan At Idco Shed No B/4 At Industrial Estate, Paradeep Garh In The District Of Jagatsinghpur For The Year 2026-27.
Tender Value
53 Lakhs
Estimated cost
Bid Submission
19 Sep 2026
3 days left
EMD
53004
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jagatsinghapur → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair & Renovation Of Proposed Kaushal Bhawan At Idco Shed No B/4 At Industrial Estate, Paradeep Garh In The District Of Jagatsinghpur For The Year 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | (CIVIL WORKS) Earth work in excavation of foundation trenches in hard soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete as directed by the Engineer in charge. |
| 2 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge. |
| 3 | Providing and laying P.C.C. (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties, taxes of all materials and cost of all labours, T&P etc complete as per the direction of the Engineer -in –charge. |
| 4 | R.C.C. work of M-20 grade having minimum compressive strength in work test of 200 Kg/Cm2 at 28 days using 20 mm and down graded size black hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting lowering and laying concrete and compacting by using vibrators watering, curing for 28 days, centring & shuttering and finishing the exposed surface smooth providing grooves or beads where necessary in all floors including cost, conveyance, royalties and taxes of all materials , cost of all labour with cost of all T&P required for the work etc. complete in all respect but excluding cost and conveyance of M.S. rods or steel & binding wires and labour charges for strengthening, cutting, bending grills and placing in proper position.(Colomn Base) |
| 5 | RCC M-20 PLINTH BAND |
| 6 | RCC M-20 COLUMN & BEAM |
| 7 | Straightening cutting, bending bent up or coiled rods, including cranking, hooking, welding or jointing the M.S. rods or tor confirming to I.S. 432 (Plain) and 1785 (Tor) steel and binding, tying the grills, hoisting, lowering and placing in proper position required for R.C.C. works including cost, conveyance and taxes of M.S. rods or tor steel and binding wires of 18 to 20 gauge and cost of all labour with all T&P required for the work etc. complete as directed by the Engineer- in-Charge. |
| 8 | Fly ash brick masonry in cement mortar (1:6) using fly ash bricks of 10” size having a crushing strength of not less than 75 kg per Sq.cm with dimensional tolerance + 8 percent after immersing Bricks for six hours in waters before use with all necessary projections, splays cutting, circular moulding, chamfering, corbelling, watering, curing etc. complete including cost, conveyance, royalties, taxes of all materials, cost of all labour, all T&P etc. complete in all respect as directed by the Engineer-in-charge. (Foundation Plinth) |
| 9 | Providing & fixing of wall panelling with EPS panels in exterior walls 75mm thickness. The panels erected must be water & air tight & fixed with GI channel of required thickness help of anchor fastener & 40x40 tubular section welded column to column with base cleat at the bottom.T he clear height from floor to ceiling should be 9'7\\" with all complete as per diriction of Engineer in-charge . |
| 10 | Providing & fixing of wall panelling with EPS panels in exterior walls 50mm thickness. The panels erected must be water & air tight & fixed with GI channel of required thickness help of anchor fastener & 40x40 tubular section welded column to column with base cleat at the bottom.T he clear height from floor to ceiling should be 9'7\\" with all complete as per diriction of Engineer in-charge . |
| 11 | Providing 12 mm thick C.P. with C.M. (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 12 | Providing 6 mm thick C.P. with C.M. (1:4) to RCC Work with screened and washed sharp sand for mortar and finished smooth after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 13 | Supplying, fitting & fixing of Vitrified floor tiles(Plain ivory) of premium grade having thickness 8mm to 10mm confirming to IS 13755 of size 60cm x 60cm coloured/printed series. laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 14 | Supplying, fitting, fixing of tile in dadoo 12mm thick CM (1:3) marbonite or equivalent make in all floors over jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost, conveyance and taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge. |
| 15 | Supplying, fitting & fixing of 30cm x 30cm/40cm x 40cm special plain/printed series Ceramic floor tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755. in floors laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-charge. |
| 16 | Fixing tiles/Marbles in dados skirting and risers of step on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles etc. complete. |
| 17 | Supplying, fitting & fixing of Vitrified Industrial floor tiles of premium grade having thickness 8mm to 10mm confirming to IS 4457 of size 30cm x 30cm laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge |
| 18 | Supplying of M.S. Grills, M.S.Doors, M.S. Gate etc including cost,conveyance of all materials etc.complete as per the instruction of Engineer-in-Charge . |
| 19 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the |
| 20 | Providing & fixing of openable PVC door with all necessary fittings & fixtures with all complete as per direction of engineer- in -charge |
| 21 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete (SOR-2022,Page No-234, Sl.No.-9) |
| 22 | Supplying, fitting, fixing up window (sliding type) made up Powder coated aluminum Section 151-154, 151-155, as windows frame section No. 151-155, 151-153 and 151-167 as shutter frame with 5mm thick Reflective glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc. complete as per direction of Engineer-in-charge. |
| 23 | Providing and fixing M.S grill of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply). |
| 24 | Painting two coats with approved weather seal paints over a coat of wall primer of approved colour, shade on wall surface including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge. |
| 25 | Painting two coats with plastic emulsion paint over a coat of water bond cement primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge. |
| 26 | Painting two coats with approved enamel paints over a coat of primer over new Iron/wood work of approved colour, shade including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge. |
| 27 | Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. |
| 28 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018. |
| 29 | Dismantling & removing Brick / Stone Masonry in C.M./L.M. Under 3m including stacking the useful materials for reuse & removing the debris within 50m lead with cost of all labour etc. complete. |
| 30 | Dismantling & removing RCC Columns / Beams / Slab including stacking the useful materials for reuse & removing the debris within 50m lead with cost of all labour etc. complete. |
| 31 | Removing Old lime or cement plaster including raking out joints 12mm deep and removing the debris within 50m lead with cost of all labour etc. complete. |
| 32 | Dismantling & Removing 2.5cm thick grading concrete from roof slab including removing the debris within 50m lead with cost of all labour etc. complete. |
| 33 | Dismantling & removing doors, windows & ventilators including removal of frame, hinges, fastening and stacking the useful materials for reuse & removing the debris within 50m lead with cost of all labour etc. complete. |
| 34 | Scraping old paint with scraper and wash with soda water including cost of all material labour etc complete. |
| 35 | Supply, Fabrication & Erection of Structural Steel Truss structures in position at all levels and heights to the required size, shape, alignment etc by using M.S. square hollow pipe/Angles of TATA make including necessary Base/Cap Plate, Gusset Plates, Stiffener plates, Brackets, Bolts, Cleats, clit angles,Nuts & Bolts, Column cap plate/ bolt etc. as per approved drawing of Architect / Consultant. All welding to be done by using structural steel welding including painting of the structure with two coats of anticorrosive red oxide primer (non flammable) to the exposed surfaces, including necessary equipments, tools & tackles, etc., all complete as per direction of the Engineer-In-Charge. (Truss Member Squara hollow tube - 96 x 48 (2.6 mm) to 80 x 40 (2.6 mm), Tubular section secondary Member - 96/48 RHS 3.2 mm, Anchor Bolts - Black unpainted, High Strength bolts for primery connection - Ft = 30.30 KN/Sq. cm, Machine bolts for secondary connectior - Fu = 40.00 KN/Sq. cm, and clading (roof) TATA colour sheet - 0.45 mm 550 mpa) NOTE: The sizes given above are tentative, it may vary after final design/drawings. |
| 36 | Providing, Fitting & Fixing of False pre-laminated Novapan board,Ceiling with 12 mm Aluminum anodized T section No -3215 with 2ft center to center L section No-1705 up to 15micron on four walls to be fixed by means of steel screw and PVC plug and Aluminum grid 2'-0\\"x2'-0\\" suspended from ceiling including cost, conveyance, royalties and taxes of all materials with cost of all labour, and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 37 | P.H Work :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge .(Supreme/Ashirvad/Oriplast) 20mm dia C-PVC Pipes In ground floor |
| 38 | 25mm dia C-PVC Pipes |
| 39 | 25mm dia UPVC ASTM-D Pipes |
| 40 | 40mm dia UPVC ASTM-D Pipes |
| 41 | 50mm dia UPVC ASTM-D Pipes |
| 42 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall In Ground Floor |
| 43 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.In ground floor |
| 44 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.15mm dia CP two way bib cock(Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany) |
| 45 | 15mm dia CP S.B bib cock (Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany) |
| 46 | 15mm dia CP angle stop cock (Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany) |
| 47 | 20mm dia CP Con. stop cock (Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany) |
| 48 | 15mm dia CP flange |
| 49 | 15mm Cp extention piece |
| 50 | 25mm dia C-PVC ball valve.(Ashrivad make) |
| 51 | 40mm dia C-PVC ball valve.(Ashrivad make) |
| 52 | 125mmdia C.P.grating |
| 53 | 15mm dia C.P hand shower |
| 54 | Acryalic Shelf |
| 55 | 25mmx600mm long CP towel rail |
| 56 | CP ring towel rail |
| 57 | CP soap holder |
| 58 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge.10 litres capacity pvc low level cistern (Slimline-white) |
| 59 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 3.18m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge.2000litre capacity water storage tanks (1st Floor) |
| 60 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge.110mm dia U-PVC SWR pipes(Supreme/Ashirvad) |
| 61 | 110mm U-PVC door Tee |
| 62 | 110mm U-PVC plain Tee |
| 63 | 110mm U-PVC door bend |
| 64 | 110mm U-PVC plain bend |
| 65 | 110mm dia U-PVC off set |
| 66 | 110mm dia U-PVC 'P' trap |
| 67 | 110mm dia U-PVC cowl |
| 68 | 110mm dia U-PVC clamp |
| 69 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI/PVC SWR pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge.250mm to 375mm thick wall |
| 70 | Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge.Squatting urinal (Parryware make) |
| 71 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral P or S trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge.E.W.C. with S trap plain with seat cover(Parryware/Hind ware/Cera/Kerovit/Somany) |
| 72 | Supplying all materials, labour, T&P and fixing bowl pattern urinal of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge.Half stall urinal (Jaquar)URS-WHT-13261 |
| 73 | 15mm CP spreader |
| 74 | 32mm CP doom waste |
| 75 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps(Plaza make) capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge.550mmx400mm size wash hand basin with pedestall Parryware/Hind ware/Cera/Kerovit/Somany) Class room male & female toilet + Staff M & F toilet |
| 76 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge.600mmx450mm size B.E mirror |
| 77 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:1.5:3) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, fly ash bricks in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI/P-trap gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in chargeInside size 250mmx250mm |
| 78 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeInside size 760mmx760mmx460mm |
| 79 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit |
| 80 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia u-pvc pipe alround concrete |
| 81 | 160mm dia u-pvc pipe alround concrete |
| 82 | E.I Work :- WirringRecessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5Amp, 250V Modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size, MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Make of modular switch -Anchor Roma/Legrand/L & T/ Crabtree)Group- A L.P-45 |
| 83 | Group- B L.P-22 |
| 84 | Group- C F.P-33,EFP-04 |
| 85 | Supply and fixing of 6 Amp plug with 6 Amp switch on existing board (Piano type/cover including connection etc. as required ) |
| 86 | Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 6pin 6Amp & 6Amp socket outlet and 6Amp Modular switches connection (make-Anchor Roma/ Legrand /L & T/ Crabtree) |
| 87 | Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 6pin 6Amp & 16Amp socket outlet and 16Amp Modular switches connection (make-Anchor Roma/ Legrand /L & T/ Crabtree) |
| 88 | Wiring in PVC conduit with modular switch and socket for computer board (4 Nos modular switch and socket) |
| 89 | S/F of 25Amp modular stater with 32 Amp TP connector for AC machine power point incul. All connection (Legrand/Havells/HPL) |
| 90 | Wires Recessed wiring to submain in the following sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with the following sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as required.(Make of wire-Finolex/L&T/Anchor/Havells/V-Guard//HPL)2 X 1.5 sq.mm +1 X 1.5 sq.mm 20 mm dia |
| 91 | 2 X 2.5 sq.mm +1 X 1.5 sq.mm 20 mm dia |
| 92 | 2 x4 sq.mm +1 X 1.5 sq.mm 20 mm dia for AC point and power point |
| 93 | 2x6 sq.mm +1 X 2.5 sq.mm in 25 mm dia |
| 94 | Fitting ItemS/F of 60 watt street light (Make-Havells/ Philips/Bajaj/Crompton) |
| 95 | S/F of 20Watt LED tube light Fitting(4ft) (Make-Havells/ Philips/Bajaj/Crompton) |
| 96 | S/F of 9 Watt LED bulb (Make-Havells/ Philips/Bajaj/Crompton) |
| 97 | Supply & Fixing of BLDC A.C Ceiling fan 48\\" size (1200 mm) having wattage not more than 28 watt and air delivery > 215 meter3 per min replacement warrenty will be 4 years . (Make- Crompton Energion/ Hacvells Efficiencia Neo/ Usha Technix) |
| 98 | Supply Fixing of Exhaust fan 10/12\\" size(make-/ Havells/Usha/almonard) |
| 99 | Supply and fixing of 16 way DD DB box Havells/ C&s / L&t |
| 100 | Supply and Fixing of 63 Amp.DP MCB C series ( Make-Legrand DX3/Scnider Act 9/L&T) |
| 101 | 6-32 amp SP MCB C series( Make-Legrand DX3/Scnider Act 9/L&T) |
| 102 | Supply and fixing of 3.5 C X35 Sq mm PVC Alluminium XLPE armoured cable of make - Havells/ Polycab/ KEI / V-Guard / Glowstar |
| 103 | Supply and fixing of 10 sq mm Almunium service wire including GI Stay wire of make - Polycab/ V-Guard / Havells etc |
| 104 | Earthing S/F of Copper plate Earthing complete in all respect as per specification of SR 2011 and as per Direction of Engineer-in -ChageStandard Earthing as per Govt. Spcn. |
| 105 | Salt and charcoal for G.I or copper pipe earth electrode as required |
| 106 | Supplying and laying 25mm X 5mm G.I strip on surface or in recess for connection etc as required. |
| 107 | Panel and Main switch Supply and fixing of ICDP main switch Switch of 63 Amp make - Cona / Anchor |
| 108 | Supply , installation , testing and commissioning of 100 Amp INDOOR pannel board with danger board with danger board. 16/18 SWG pannel box 24\\"X 24\\" X 10 size for single door made out of CR sheet of 16SWG and boarder angle frame to provide above pannel with proper space ,hinged door must be painted one coated red oxide and two coat enamel gray paint with powder coats. |
| 109 | Supply and fixing of internal wiring to equipment installed in the pannel board with required size of copper multistrand single core cables duly crimped with copper lugs and all connections L X B including cost of copper conductor and other fittings. |
| 110 | S/F of copper bus bar 35x 5mm with required size of insulating material and nut and bolts. |
| 111 | S/F of 100 Amp Changeover ( Make-L&T/ Legrand/Schnider/ C&S/ Havells ) |
| 112 | S/F of digital ammeter for the indoor panel |
| 113 | S/F of digital voltmeter for the indoor panel |
| 114 | Supply and fixing of Indicator lamp with toggler switch and fuse Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysSep 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender