Tender For Construction Of Smart Park At Ward No 13, Khariar Road
Tender Value
1.03 Crore
Estimated cost
Bid Submission
25 Sep 2026
3 days left
EMD
1.03 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nuapada → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Smart Park At Ward No 13, Khariar Road
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in hard soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge. |
| 2 | Earth work in ordinary soil in embankments wtihin 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per specification approved by the department along with proper compaction with P.R.R. including hire and running charges of P.R.R. |
| 3 | Additional Lift |
| 4 | Supply & Filling in Foundation and Plinth with excavated materials including watering and ramming as directed by Engineer-in- charge for cum. |
| 5 | Supply & Filling in Foundation and Plinth with sand, well watered and rammed. |
| 6 | Plain Cement concrete (1:4:8) work as levelling course with 40 mm size hard granite metal. |
| 7 | Plain Cement concrete (1:3:6) work as levelling course with 40 mm size hard granite metal. |
| 8 | R.C.C. works (M-25) in foundation, footing, beams,plinth band,footing,base of columns,lintels, roofs, chhajas mass concrete etc. using 10 mm & 20 mm size black hard granite crusher broken chips including hoisting, lowering, laying and compacting, watering, curing for 28 days including centering and shuttering and finished the exposed surface smooth including all cost, conveyances, royalties and taxes of all materials and cost of labour with T & P required for the work etc. all complete in all respect but excluding cost of Steel and labour charges for bending and binding as per the Direction of the Engineer in charge. |
| 9 | FOOTINGS |
| 10 | COLUMNS |
| 11 | PLINTH BEAM |
| 12 | COPING BEAM |
| 13 | Store and Toilet |
| 14 | Septic |
| 15 | PERGOLA FOOTINGS,Bank Protection,Boundry |
| 16 | PERGOLA COLUMNS |
| 17 | PLINTH BEAM |
| 18 | Lintel Beam |
| 19 | Roof Slab |
| 20 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specifications. |
| 21 | Fly ash brickwork in Foundation and plinth cement mortar (1:6) by using 9\\" size bricks including all cost, conveyence etc. complete. |
| 22 | Fly ash brickwork in \\"Superstructure\\" cement mortar (1:4) by using 9\\" size bricks including all cost, conveyence etc. complete. |
| 23 | 12cm thick honey comb brick works in cement mortar (1:4) including cement plaster (1:6) complete |
| 24 | 12mm thick cement plaster (1:4) inside & OUTSIDE with cement punning, racking out the joints, watering and curing etc. complete with cost, conveyance royalties and taxes of all materials & all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge. |
| 25 | Priming 1 coat with Wall Cement Primer to Outside Surface of Walls after cleaning the surface including cost of primer, conveyence and taxes all materials including cost of all labour and T & P etc.required for the work complete in all respect as per the direction of the Engineer in Charge. |
| 26 | Painting Two coats to Outside Surface of Walls etc. of Approved Shade & color using Weather Coat to the surface of Walls after cleaning the surface including cost,conveyence and taxes all materials including cost of all labour and T & P etc.required for the work complete in all respect as per the direction of the Engineer in Charge. |
| 27 | Dry stone masonry or rough stone dry masonary for guard walls and retaining walls with hard granite stones |
| 28 | Back filling Granular Material behind Guard Wall complete as per drawing and Technical Specification |
| 29 | 16mm thick cement plaster (1:6) outside with cement punning, racking out the joints, watering and curing etc. complete with cost, conveyance royalties and taxes of all materials & all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge. |
| 30 | 6 mm thick cement plaster (1:4) to R.C.C. Surfaces finished smooth including closed deep chipping and slurry treatment to Ceiling including watering and curing complete with cost, conveyance, royalties, and taxes of all materials and cost of all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge. |
| 31 | Supplying, fitting and fixing of Plain (Ivory) Vetrified tiles of premium grade in floors of size 600mm x 600mm of approved make conforming to IS: 13755 laid on 20mm thick cement mortar (1:4) and filing the joints with white cement of approved quality including cost of all materials, labour T&P taxes etc. complete reuired for the work as per direction of Engineer in charge |
| 32 | Supplying and fixing Colour Coated G.C.I. Sheet (0.4mm THK.) of TATA BLUESCOPE DURASHINE RED COLOR in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc. ,including cost of fitting, conveyances, T&P, etc. |
| 33 | Supplying, hoisting joists and trusses of grade E350 and placing in position including all costs complete, as per direction of Engineer-in-charge. |
| 34 | Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018. |
| 35 | Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. |
| 36 | Supplying, fitting and fixing of Vitrified tile in dados, skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles as per direction of engineer in charge |
| 37 | Supplying , fitting and fixing of fixed UPVC Window/Ventilators of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 38 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 39 | Finishing wall surface with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T & P etc complete. |
| 40 | Wall Painting two Coats with Plastic Emulsion Paint of approved shade on new work to give an even shade including cost, conveyence and taxes all materials including cost of all labour and T & P etc. required for new work complete in all respect as per the Direction of the Engineer in charge. |
| 41 | Plain Cement Concrete of Grade M15 in Ground Floor complete as per Drawing and Technical Specifications. |
| 42 | Cement Concrete ( 1 : 2 : 4 ) with 12mm size HG chips all complete |
| 43 | Fitting & fixing of M.S. Step Iron built in wall complete. |
| 44 | Commissioning of Septic tank with charge full water. |
| 45 | Fixing Water Closet (Orissa type sqatting pan ) 500 mm x 440mm size white glazed Vitreous China Orissa Pattern squatting pan conforming to IS:2556,Part.3-2004 duly embeded in cement conrete (1:4:8) all complete as per specification. |
| 46 | Fixing Bowl Pattern Urinal conforming to IS 2556: PART 6-1996 including connecting the urinal of 430x260x350mm or 340x410x265mm size respectively with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification. |
| 47 | Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. (Seat and cover to be measured and paid separetely. |
| 48 | Fixing Automatic flushing cistern with a pair of Cast Iron or M.S brackets complete with fittings including Cast iron siphonic apparatus, mosquito proof lead, chromium plated brass couplings for connections with inlet, outlet and overflow pipes, making connection with suply main with 12mm dia pvc inlet pipe including cutting holes and making good the same all complete as per specification. |
| 49 | Fixing Counter top wash basin 560x455 mm with hole for pillar taps conforming to IS 2556 : Part 4-2004 with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification. |
| 50 | Fixing bevelled edge mirror of superior glass mounted on 6mm thick AC sheet or ply wood sheetand fixed to wooden plugs with CP brass screws and washers etc complete as per specification. |
| 51 | Fixing CP brass soap holder complete with CP brass brackets fixed to wooden plugs with CP brass screws etc complete as per specification. |
| 52 | Fixing CP double coat hook complete with CP brass brackets fixed to wooden plugs with CP brass screws etc complete as per specification. |
| 53 | 32mm dia |
| 54 | 32mm dia |
| 55 | Fixing of CP Brass Short-body Bib Cock polished bright conforming to IS:781-1995 of 15mm dia nominal bore as per the specification complete. |
| 56 | Fixing of 15mm C.P brass Angular Stop Cock conforming to IS781/1995 of following nominal sizes as per specification complete. |
| 57 | Fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, Urinals complete as per specification complete. |
| 58 | 15 mm nominal dia |
| 59 | 20 mm nominal dia |
| 60 | 25 mm nominal dia |
| 61 | 32 mm nominal dia |
| 62 | Concealled stop cock |
| 63 | Fixing Cast iron floor traps of the following nominal diameter of outlet of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all comlete as per specification |
| 64 | 2000 litre capacity Double Layer Cylinderical Vertical water storage tanks (Without stagging) |
| 65 | 110 mm OD P.V.C. SWR S/S Pipe (ISI type-A) |
| 66 | Single Tee with door |
| 67 | Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc all complete as per specification. |
| 68 | Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification complete. |
| 69 | C.P. Grating |
| 70 | Supplying and fixing of following sizes of PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. |
| 71 | GENTS TOILET |
| 72 | LADIES TOILET |
| 73 | TICKET COUNTER |
| 74 | STORE ROOM |
| 75 | TICKET COUNTER |
| 76 | STORE ROOM |
| 77 | Recessed wiring to for 5/6 amp socket outlet with 6 amp ,250 V clip in type switch ISI marked mounted on modular GI box with modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. |
| 78 | Recessed wiring to for 5/6 amp socket outlet with 2x1.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked in 20mm dia non metallic PVC conduit with 6 amp ,250 V clip in type switch ISI marked mounted on modular GI box with modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havells /HPL/ V Guard ) Group C. |
| 79 | Recessed wiring to for 2x6 amp socket outlet controlled by 2 nos with 6 amp ,250 V clip in type switch ISI marked mounted on modular GI box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. |
| 80 | Recessed wiring to for 5/6 amp socket outlet with 2x1.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked in 20mm dia non metallic PVC conduit with 6 amp ,250 V clip in type switch ISI marked mounted on modular GI box with modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havells /HPL/ V Guard ) Group C. |
| 81 | Recessed wiring to for 6pin 16 amp socket outlet with 5 amp ,250 V clip in type switch ISI marked mounted on GI modular box with modular base face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. |
| 82 | Recessed wiring to submain in 4x 6 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS -694/1990 IN 32 mm dia non metallic heavy duty PVC conduit 1.6 mm thick along with 2x4 sqmm FR-PVC insulated single core multi strand copper conducter as earth wire required. |
| 83 | Recessed wiring to submain in 2x 6 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS -694/1990 IN 25 mm dia non metallic heavy duty PVC conduit 1.6 mm thick along with 1x4 sqmm FR-PVC insulated single core multi strand copper conducter as earth wire required. |
| 84 | Recessed wiring to submain in 2x 4 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS -694/1990 IN 20 mm dia non metallic heavy duty PVC conduit 1.6 mm thick along with 1x2.5 sqmm FR-PVC insulated single core multi strand copper conducter as earth wire required. |
| 85 | Recessed wiring to submain in 2x 2.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS -694/1990 IN 20 mm dia non metallic heavy duty PVC conduit 1.6 mm thick along with 1x1.5 sqmm FR-PVC insulated single core multi strand copper conducter as earth wire required. |
| 86 | Recessed wiring to submain in 2x 1.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS -694/1990 IN 20 mm dia non metallic heavy duty PVC conduit 1.6 mm thick along with 1x1.5 sqmm FR-PVC insulated single core multi strand copper conducter as earth wire required. |
| 87 | Supply and fixing of following way three pole and neutral sheet steel, MCB distribution, 415 V on surface / recess complte with tinned copper bus bar, neutral bus bar, earth bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc as required (but without MCB/RCCB/Isolator). |
| 88 | Supply and fixing of following way single pole MCB with sheet steel enclosure distribution board on surface / recess complte with tinned copper bus bar, neutral bus bar, earth bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc as required (but without MCB/RCCB/Isolator). |
| 89 | Supply and fixing of following rating 240 V Minature circuit breaker (mcb) having a sensitivity current upto 10KA in the existing MCB DB ISIS marked complete with connection testing and commissioning etc as required. |
| 90 | Supply and fixing of following rating 240 V RCBO having a sensitivity current upto 100mA in the existing MCB DB ISIS marked complete with connection testing and commissioning etc as required. |
| 91 | Supply of 1 no. of PVC sheathed/XLP power cable of 1.1 KV grade of following sizes of cable as required (3.5C X 150 sqmm AI) |
| 92 | Supply of 1 no. of insulated and PVC seathed/XLP power cable of 1.1 KV grade of following sizes of cable as required (3.5C X 50 sqmm AI) |
| 93 | Supply of 1 no. of insulated and PVC seathed/XLP power cable of 1.1 KV grade of following sizes of cable as required (3.5C X 25 sqmm AI) |
| 94 | Laying of 1 no. of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sqmm but not exceeding 120 sqmm direct in ground including exacavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 95 | Laying of 1 no. of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size exceeding 120 sqmm but not exceeding 400 sqmm direct in ground including exacavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 96 | Laying of 1 no. of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size exceeding 120 sqmm but not exceeding 400 sqmm direct in ground in the same trench in one tier horizontal formation including exacavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 97 | Laying of 1 no. of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sqmm but not exceeding 400 sqmm in the existing RCC/HUMES/STONEWARE/METAL pipe as required. |
| 98 | Laying and fixing of 1 no. of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sqmm on surface as required. |
| 99 | Laying and fixing of 1 no. of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sqmm but not exceeding 120 sqmm on surface as required. |
| 100 | Supplying and making end termination with brass compression gland and aluminium lugs for the following size of PVC insulated and PVC sheathed/XLPE aluminum cable of 1.1 KV as reqyuired. |
| 101 | Fountains |
| 102 | Precast Benches, Dustbins, Children Play & Gym Equipments Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysSep 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender