Tender for Construction Of Smart Park At Ward No 13, Khariar Road

BOQ

Name of Work:- CONSTRUCTION OF SMART PARK AT WARD NO 13, KHARIAR ROAD
Sl. No. Item Description
1Earth work in hard soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge.
2Earth work in ordinary soil in embankments wtihin 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per specification approved by the department along with proper compaction with P.R.R. including hire and running charges of P.R.R.
3Additional Lift
4Supply & Filling in Foundation and Plinth with excavated materials including watering and ramming as directed by Engineer-in- charge for cum.
5Supply & Filling in Foundation and Plinth with sand, well watered and rammed.
6Plain Cement concrete (1:4:8) work as levelling course with 40 mm size hard granite metal.
7Plain Cement concrete (1:3:6) work as levelling course with 40 mm size hard granite metal.
8R.C.C. works (M-25) in foundation, footing, beams,plinth band,footing,base of columns,lintels, roofs, chhajas mass concrete etc. using 10 mm & 20 mm size black hard granite crusher broken chips including hoisting, lowering, laying and compacting, watering, curing for 28 days including centering and shuttering and finished the exposed surface smooth including all cost, conveyances, royalties and taxes of all materials and cost of labour with T & P required for the work etc. all complete in all respect but excluding cost of Steel and labour charges for bending and binding as per the Direction of the Engineer in charge.
9FOOTINGS
10COLUMNS
11PLINTH BEAM
12COPING BEAM
13Store and Toilet
14Septic
15PERGOLA FOOTINGS,Bank Protection,Boundry
16PERGOLA COLUMNS
17PLINTH BEAM
18Lintel Beam
19Roof Slab
20Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specifications.
21Fly ash brickwork in Foundation and plinth cement mortar (1:6) by using 9\\" size bricks including all cost, conveyence etc. complete.
22Fly ash brickwork in \\"Superstructure\\" cement mortar (1:4) by using 9\\" size bricks including all cost, conveyence etc. complete.
2312cm thick honey comb brick works in cement mortar (1:4) including cement plaster (1:6) complete
2412mm thick cement plaster (1:4) inside & OUTSIDE with cement punning, racking out the joints, watering and curing etc. complete with cost, conveyance royalties and taxes of all materials & all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge.
25Priming 1 coat with Wall Cement Primer to Outside Surface of Walls after cleaning the surface including cost of primer, conveyence and taxes all materials including cost of all labour and T & P etc.required for the work complete in all respect as per the direction of the Engineer in Charge.
26Painting Two coats to Outside Surface of Walls etc. of Approved Shade & color using Weather Coat to the surface of Walls after cleaning the surface including cost,conveyence and taxes all materials including cost of all labour and T & P etc.required for the work complete in all respect as per the direction of the Engineer in Charge.
27Dry stone masonry or rough stone dry masonary for guard walls and retaining walls with hard granite stones
28Back filling Granular Material behind Guard Wall complete as per drawing and Technical Specification
2916mm thick cement plaster (1:6) outside with cement punning, racking out the joints, watering and curing etc. complete with cost, conveyance royalties and taxes of all materials & all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge.
306 mm thick cement plaster (1:4) to R.C.C. Surfaces finished smooth including closed deep chipping and slurry treatment to Ceiling including watering and curing complete with cost, conveyance, royalties, and taxes of all materials and cost of all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge.
31Supplying, fitting and fixing of Plain (Ivory) Vetrified tiles of premium grade in floors of size 600mm x 600mm of approved make conforming to IS: 13755 laid on 20mm thick cement mortar (1:4) and filing the joints with white cement of approved quality including cost of all materials, labour T&P taxes etc. complete reuired for the work as per direction of Engineer in charge
32Supplying and fixing Colour Coated G.C.I. Sheet (0.4mm THK.) of TATA BLUESCOPE DURASHINE RED COLOR in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc. ,including cost of fitting, conveyances, T&P, etc.
33Supplying, hoisting joists and trusses of grade E350 and placing in position including all costs complete, as per direction of Engineer-in-charge.
34Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018.
35Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984.
36Supplying, fitting and fixing of Vitrified tile in dados, skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles as per direction of engineer in charge
37Supplying , fitting and fixing of fixed UPVC Window/Ventilators of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
38Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
39Finishing wall surface with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T & P etc complete.
40Wall Painting two Coats with Plastic Emulsion Paint of approved shade on new work to give an even shade including cost, conveyence and taxes all materials including cost of all labour and T & P etc. required for new work complete in all respect as per the Direction of the Engineer in charge.
41Plain Cement Concrete of Grade M15 in Ground Floor complete as per Drawing and Technical Specifications.
42Cement Concrete ( 1 : 2 : 4 ) with 12mm size HG chips all complete
43Fitting & fixing of M.S. Step Iron built in wall complete.
44Commissioning of Septic tank with charge full water.
45Fixing Water Closet (Orissa type sqatting pan ) 500 mm x 440mm size white glazed Vitreous China Orissa Pattern squatting pan conforming to IS:2556,Part.3-2004 duly embeded in cement conrete (1:4:8) all complete as per specification.
46Fixing Bowl Pattern Urinal conforming to IS 2556: PART 6-1996 including connecting the urinal of 430x260x350mm or 340x410x265mm size respectively with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification.
47Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. (Seat and cover to be measured and paid separetely.
48Fixing Automatic flushing cistern with a pair of Cast Iron or M.S brackets complete with fittings including Cast iron siphonic apparatus, mosquito proof lead, chromium plated brass couplings for connections with inlet, outlet and overflow pipes, making connection with suply main with 12mm dia pvc inlet pipe including cutting holes and making good the same all complete as per specification.
49Fixing Counter top wash basin 560x455 mm with hole for pillar taps conforming to IS 2556 : Part 4-2004 with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification.
50Fixing bevelled edge mirror of superior glass mounted on 6mm thick AC sheet or ply wood sheetand fixed to wooden plugs with CP brass screws and washers etc complete as per specification.
51Fixing CP brass soap holder complete with CP brass brackets fixed to wooden plugs with CP brass screws etc complete as per specification.
52Fixing CP double coat hook complete with CP brass brackets fixed to wooden plugs with CP brass screws etc complete as per specification.
5332mm dia
5432mm dia
55Fixing of CP Brass Short-body Bib Cock polished bright conforming to IS:781-1995 of 15mm dia nominal bore as per the specification complete.
56Fixing of 15mm C.P brass Angular Stop Cock conforming to IS781/1995 of following nominal sizes as per specification complete.
57Fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, Urinals complete as per specification complete.
5815 mm nominal dia
5920 mm nominal dia
6025 mm nominal dia
6132 mm nominal dia
62Concealled stop cock
63Fixing Cast iron floor traps of the following nominal diameter of outlet of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all comlete as per specification
642000 litre capacity Double Layer Cylinderical Vertical water storage tanks (Without stagging)
65110 mm OD P.V.C. SWR S/S Pipe (ISI type-A)
66Single Tee with door
67Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc all complete as per specification.
68Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification complete.
69C.P. Grating
70Supplying and fixing of following sizes of PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
71GENTS TOILET
72LADIES TOILET
73TICKET COUNTER
74STORE ROOM
75TICKET COUNTER
76STORE ROOM
77Recessed wiring to for 5/6 amp socket outlet with 6 amp ,250 V clip in type switch ISI marked mounted on modular GI box with modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.
78Recessed wiring to for 5/6 amp socket outlet with 2x1.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked in 20mm dia non metallic PVC conduit with 6 amp ,250 V clip in type switch ISI marked mounted on modular GI box with modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havells /HPL/ V Guard ) Group C.
79Recessed wiring to for 2x6 amp socket outlet controlled by 2 nos with 6 amp ,250 V clip in type switch ISI marked mounted on modular GI box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge.
80Recessed wiring to for 5/6 amp socket outlet with 2x1.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked in 20mm dia non metallic PVC conduit with 6 amp ,250 V clip in type switch ISI marked mounted on modular GI box with modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havells /HPL/ V Guard ) Group C.
81Recessed wiring to for 6pin 16 amp socket outlet with 5 amp ,250 V clip in type switch ISI marked mounted on GI modular box with modular base face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.
82Recessed wiring to submain in 4x 6 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS -694/1990 IN 32 mm dia non metallic heavy duty PVC conduit 1.6 mm thick along with 2x4 sqmm FR-PVC insulated single core multi strand copper conducter as earth wire required.
83Recessed wiring to submain in 2x 6 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS -694/1990 IN 25 mm dia non metallic heavy duty PVC conduit 1.6 mm thick along with 1x4 sqmm FR-PVC insulated single core multi strand copper conducter as earth wire required.
84Recessed wiring to submain in 2x 4 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS -694/1990 IN 20 mm dia non metallic heavy duty PVC conduit 1.6 mm thick along with 1x2.5 sqmm FR-PVC insulated single core multi strand copper conducter as earth wire required.
85Recessed wiring to submain in 2x 2.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS -694/1990 IN 20 mm dia non metallic heavy duty PVC conduit 1.6 mm thick along with 1x1.5 sqmm FR-PVC insulated single core multi strand copper conducter as earth wire required.
86Recessed wiring to submain in 2x 1.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS -694/1990 IN 20 mm dia non metallic heavy duty PVC conduit 1.6 mm thick along with 1x1.5 sqmm FR-PVC insulated single core multi strand copper conducter as earth wire required.
87Supply and fixing of following way three pole and neutral sheet steel, MCB distribution, 415 V on surface / recess complte with tinned copper bus bar, neutral bus bar, earth bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc as required (but without MCB/RCCB/Isolator).
88Supply and fixing of following way single pole MCB with sheet steel enclosure distribution board on surface / recess complte with tinned copper bus bar, neutral bus bar, earth bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc as required (but without MCB/RCCB/Isolator).
89Supply and fixing of following rating 240 V Minature circuit breaker (mcb) having a sensitivity current upto 10KA in the existing MCB DB ISIS marked complete with connection testing and commissioning etc as required.
90Supply and fixing of following rating 240 V RCBO having a sensitivity current upto 100mA in the existing MCB DB ISIS marked complete with connection testing and commissioning etc as required.
91Supply of 1 no. of PVC sheathed/XLP power cable of 1.1 KV grade of following sizes of cable as required (3.5C X 150 sqmm AI)
92Supply of 1 no. of insulated and PVC seathed/XLP power cable of 1.1 KV grade of following sizes of cable as required (3.5C X 50 sqmm AI)
93Supply of 1 no. of insulated and PVC seathed/XLP power cable of 1.1 KV grade of following sizes of cable as required (3.5C X 25 sqmm AI)
94Laying of 1 no. of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sqmm but not exceeding 120 sqmm direct in ground including exacavation, sand cushioning, protective covering and refilling the trench etc as required.
95Laying of 1 no. of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size exceeding 120 sqmm but not exceeding 400 sqmm direct in ground including exacavation, sand cushioning, protective covering and refilling the trench etc as required.
96Laying of 1 no. of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size exceeding 120 sqmm but not exceeding 400 sqmm direct in ground in the same trench in one tier horizontal formation including exacavation, sand cushioning, protective covering and refilling the trench etc as required.
97Laying of 1 no. of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sqmm but not exceeding 400 sqmm in the existing RCC/HUMES/STONEWARE/METAL pipe as required.
98Laying and fixing of 1 no. of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sqmm on surface as required.
99Laying and fixing of 1 no. of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sqmm but not exceeding 120 sqmm on surface as required.
100Supplying and making end termination with brass compression gland and aluminium lugs for the following size of PVC insulated and PVC sheathed/XLPE aluminum cable of 1.1 KV as reqyuired.
101Fountains
102Precast Benches, Dustbins, Children Play & Gym Equipments Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57439457
AUTHORITY Local Bodies
TENDER VALUE 1.03 Crore
LAST DATE 25-09-2026
Authority
Authority Name Municipal Bodies
Work Description Tender for Construction Of Smart Park At Ward No 13, Khariar Road
Basic Detail
Tender No 3817/KHRD
Bidding Type Tender
Location
City Nuapada
State Odisha
Key Dates
Publish Date 09 Sep 2026
Submission Date 25 Sep 2026
Open Date 29 Sep 2026
Finance
Tender Value 1.03 Crore
Tender Fee 10000
EMD 1.03 Lakhs
Exemption Available
Document List
37536ff0-8db2-4b6e-8669-48839c588c8a.html
BOQ_608754.xls
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

37536ff0-8db2-4b6e-8669-48839c588c8a.html

xls

BOQ_608754.xls

pdf

Tendernotice_1 (19).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders