Tender For Annual Maintenance Works Programme For Office Accomodation Pao(Ors) Corps Of Signal Jabalpur For Fy 2026-27
Tender Overview
Project Description
Tender for Annual Maintenance Works Programme For Office Accomodation Pao(Ors) Corps Of Signal Jabalpur For Fy 2026-27
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 08-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articlesas in walls/parapet wall,s removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces complete all as specified and directed |
| 2 | M&L for Brick work with sub class ‘B’ brick, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed |
| 3 | M&L for Brick work with sub class ‘B’ brick, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed |
| 4 | Taking down cement plaster / terrazzo of any description thickness including raking out joints hacking for key scrubbing down with watercomplete all as specified and directed |
| 5 | M&L for 15 mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all specified and directed. |
| 6 | M&L for rendering on concrete/brick surfaces 15mm thick in CM 1:4 surface finished even and smooth without using extra cement complete all as specified and directed |
| 7 | M&L for 5mm thick rendering in cement mortar 1:3 on concrete surfaces, ceiling etc finished surface even and smooth, without using extra cement complete all as specified and directed |
| 8 | M&L for preparation of newly plastered surfaces and applying three coats of white wash as in ceilling complete all as specified and as directed. |
| 9 | M&L for Preparing newly plastered surfaces of internal wall and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and as directed. |
| 10 | M&L 3mm thick wall care putty on wall complete all as specified and directed |
| 11 | Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces & also providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 12 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets including E- Grid frame work complete all as specified and directed. |
| 13 | S&F suspended false ceiling system using Chicago metallic (E-grid) exposed suspended system, grid size 600x600mm comprising of GI powder coated main runner of dimension 39mmx24mm x 0.8mm thick (Thickness comprising of GI/0.5mm+PPPCGS/0.3mm & weight of runner 1.35 Kg for 3600mm length), cross Tee of dimension 29mm x 24mm x 0.7mm thick (Thickness comprising of GI/0.5mm+PPPCGS/0.3mm & weight of Tee 0.195Kg for 600mm length) and wall angle of dimension 22.2mm x 22.2mm x 0.65mm thick (Thickness comprising of GI/0.35mm + PPPCGS/0.30mm & weight of angle 0.700 Kg for 3050mm length) with and including 4mm thick HSPC (High Pressure Steam Cured) pre-primed, self embossed, textured designer board, water, termite & fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins with butterfly clips (wt 0.007 Kg/clip), hold down clips (wt - 0.0035 Kg/clip), with provisionn of light fixture complete all as per manufacturer instructions and as directed. |
| 14 | Fixing only 6mm thick Non asbestos cement building boards in ceiling flat or sloping fixed or laid/inserted to timber/GI/Aluminium frame work fixed with screw as per manufacturer's instructions Non asbestos cement building boards |
| 15 | S&F Solid PVC wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing all as specified& directed. |
| 16 | S&F 5mm tjocl PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on wall to make PVC frame as per specification and drawing complete all as specified and directed. |
| 17 | Dismantling of asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed |
| 18 | M&L Pre-painted galvalume aluminium zinc coating GI based corrugatged steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 19 | M&L Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 20 | Dismantling timber fillets,posts rafter purlin under 40 sqcm framed work in sectional area,complete all as specified and as directed. |
| 21 | Dismantling timber in scantling 40Sqcm and over in section framed work in any position complete all as specified and directed. |
| 22 | Dismantling wroght iron or mild steel work of any description not oterwise provide for |
| 23 | S&F hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc,) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe410-0 or Fe 310-0 complete all as specified and directed. |
| 24 | Fixing only wind ties complete all as specified and directed |
| 25 | S&F mild steel screw bolt (machine made) with square or hexagonal head at one end, screwed other, fitted with washer and one hexagonal or square n exc 5cm, long and 5 to 10mm dia complete all as specified and directed. |
| 26 | S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to a common rafters, fixed with angle cleats or other connecting plates of Gde Fe 410 -W (Gde E- 250) Quality - A , complete all as specified and directed. |
| 27 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers ,apex stones, bed plates, water troughs and the like including use of formwork (straight or curved) ,including weathering, slightly rounded or chamfered angles and throating, all as specified and as directed (Note :- Reinforcement where provided shall be measured and paid seprately) |
| 28 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 29 | M&L for precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) as in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed. |
| 30 | M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9 mm dia or securing with clips complete. |
| 31 | M&L for Mild steel TMT bars 5 mm and over upto and including 10 mm dia in stirrups,spaces and binders cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire ( annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 32 | Dismantaling floor hearth or wall tiling/china moisac including cement mortar bedding (but not backing ) , removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 33 | M&L for glazed ceramic coloured tiles of size 450 x 300 x 6 to 7 mm,450x350 or 350x250 6 to 7mm thick on vertical surface such as skirting/dado etc. ,set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile with & including rendering 10 mm thick cement plaster as backing coat in cement mortar 1:4 finished rough to fix tiles complete all as specified and directed. |
| 34 | M&L for Non skid coloured ceramic tiles 7 to 8mm thick square/ rectangular area of Each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match, laid over and including 15mm thick cement screed bed in cement mortar 1:6 complete all as specified and directed. |
| 35 | M&L for double charged Virified ceramic tiles dark shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloure of tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specfied and directed. |
| 36 | M&L for double charged Virified ceramic tiles dark shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, as in vertical surfaces such as dados/skirting etc set and jointed in neat cement slury and in coloured cement to match Coloured including plaster (backing coat) 1:4 CM 10mm thick complete all as specified and directed. |
| 37 | M&L for Vitrified ceremic tiles 9-10 mm thick, in LIGHT/DARK SHADE, (Square/rectangular) polished, area of Each tile not exceeding 0.36 Sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specfied and directed. |
| 38 | M&L for Vitriefied ceramic tiles 9-10mm thick LIGHT/DARK SHADE(square/rectangular) polished area of Each tiles not exceeding 0.36 Sqm as in vertical surfaces such as dados/skirting etc set and jointed in neat cement slury and in coloured cement to match Coloured including plaster (backing coat) 1:4 CM 10mm thick complete all as specified and directed. |
| 39 | M&L for Granite (of any type ) 20 mm thick work (table rubbed and polished ) in steps ,jambs,pilllars,window cill,cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2)using marble dust with admixture of pigment to match with shade of Granite laid over 20mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 40 | Demolition of cement concrete in ground floor and paving not exc 15cm thickness (below or above ground level) complete all as specified and directed |
| 41 | M&L for 25mm thick cement concret Type B-1 1:2:4 (Using 20mm graded stone aggregate ) complete all as specified and directed. |
| 42 | M&L 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed |
| 43 | Material and labour 20- 25 mm thick machine cut kota stone flooring 20 to 20 mm thick over cement screed base laid and jointed with neat cement slurry mixed with pigment to match the shade of the slab laid over 20 mm thick bedding layer in cement mortar 1:6 including rubbing and polishing complete all as specified and directed |
| 44 | M&L 20 to 25 mm thick machine cut kota stone as in vertical surfaces risers of steps , skirting, dado and pillars etc set and jointed in neat cement slurry and pointed with grey cement mixed with pigment to match the colour of stone slab laid over and including 10 mm thick rendering in cement mortar 1:4 including rubbing and mirror polishing complete all as specified and directed |
| 45 | M&L 75 mm thick PCC 1:3:6 type C-2 using 20mm graded aggregate as in plinth protection finishing even & fair without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 grade and three part of sand ( all by weight) complete all as specified and directed |
| 46 | Taking down chowkhats or frame (with shutter without taking off shutter from the frame) area not exc 1.5 Sqm Each all as specified. |
| 47 | Taking down chowkhats or frame (with shutter without taking off shutter from the frame) area exc 1.5 Sqm but n-exc 4 Sqm Each . |
| 48 | S&F 2nd class H/W plain solid straight chowkhat or frame, wrought framed rebated on the solid, rounded or chamfered put together with flue pinned at joints etc and in position complete all as specified and directed |
| 49 | S&F, Powder coated (minimum thickness of powder coating 50 micron) Aluminium anodised sections for doors/ windows/ ventilators with one or more rebates including joining cleat for fixing etc complete with frames, shutters and grills of size directed by Engineer-in-charge including handles, tower bolts, grills, etc complete all as specified and directed. Note:- Floor door spring, sheet glass, wire cloth, lock, etc shall be measured and paid seperately. |
| 50 | S & F 30 mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides decorative face veneer with lipping/frame to match supplied and fitted to chowkats, complete all as specified and directed. |
| 51 | S & F 30 mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides supplied and fitted to chowkats.all as specified and directed. |
| 52 | S & F factory made 35 mm thick plain, framed, panelled shutters (Two panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces and size of the members of shutter are as per IS – 1003 (Part – I) made of kiln seasoned & chemically pressure treated 2nd class hardwood rail and style complete all as specified and directed. |
| 53 | S&F 30mm thick 2nd class H/W glazed skelton shutter for window/ventilator, open rebated and prepared to receive glass , gauze etc (with sash bars) edges of framing plain chamfered or rounded , fitted with cut and mitered beads for securing glass etc; size of members of shutters as specified in SSR Part -I,section 8,clause 8.24 (a) complete all as specified and as directed. |
| 54 | S&F steel windows with side hung shutter including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 55 | S&F steel windows with side hung shutter including projecting type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed. |
| 56 | S&F steel windows or ventilators, fixed type with glazing bars complete all as specified and directed |
| 57 | S&F PVC door frame size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinf with MS square tube supplying & fixing in opening as per specificationn complete all as specified and directed |
| 58 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails . M,S frame shall be covered with heat moulded plain colour PVC ,C, channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rails , lock rails and bottom rails on either side and as gap insert for top rail and bottom rail Panelling of plain colour PVC sheet to be fitted in the M.S frame welded /sealed to the stiles & rails with suitable PVC sheet beading , and jointed together with solvent cement , supplying and fising in the frame at site as per specification and drawing complete all as specified and directed |
| 59 | S&F, aluminium anodised, barrel tower bolts of extruded section with length of bolt 200 mm and fixed complete all as specified and directed |
| 60 | S&F, aluminium anodised, barrel tower bolts of extruded section with length of bolt 150 mm and fixed complete all as specified and directed |
| 61 | S&F, aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy with length of bolt 300 mm and fixed complete all as specified and directed. |
| 62 | S&F, 100mm butt hinges extruded aluminium alloy with galvanised mild steel hinge pin,Type-B-21 complete all as specified and directed. |
| 63 | S&F mild steel cold rolled medium weight butt hinges 75mm size fixed screws to wooden frames or with welding to steel frames all as specified and directed by Engr-in-charge. |
| 64 | S&F continuos (piano) hinges,mild steel bright finish or electrogalvanised,width of flaps 30 mm complete all as specified and directed |
| 65 | S&F extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed. |
| 66 | S&F extruded aluminium alloy handles, fabricated type, anodised of size 125 mm complete all as specified and directed. |
| 67 | S&F 150mm long floor door stopper of aluminium alloy body and tongue with hard drawn steel springcomplete all as specified and directed. |
| 68 | S&F door closer hydraulically regulated designation No-2 universal type of aluminium body fixed to door frames with screws or by welding complete for door shutters of 850 to 1000mm in width acomplete all as specified and directed |
| 69 | S&F 300mm long mild steel ordinary rat tail rod pattern springs,including roller and roller plate complete all as specified and directed. |
| 70 | S&F 125mm hasp and staples,aluminium anodized including bolt to hinges plate and fixed with screws complete all as specified and directed |
| 71 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staple/ wooden beads complete all as specified. |
| 72 | M&L for 9 mm thick prelaminated particle board interior grade,prelaminated both sides with decorative choice laminaions fixed with screw to timber/steel frame work as in repair complete all as specified and directed |
| 73 | M&L for 18/19 mm thick prelaminated particle board interior grade,prelaminated both sides with decorative choice laminaions fixed with screw to timber/steel frame work as in repair complete all as specified and directed |
| 74 | S&F 3mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in Each pane complete all as specified and directed |
| 75 | S&F 4mm thick figured glass, pinn headed type and glazing with oil putty in square n. exc 0.5 Sqm Each panes complete all as specified and directed |
| 76 | Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new one complete all as specified |
| 77 | S&F 5.5mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in Each pane complete all as specified and directed |
| 78 | S&F 5.5mm thick Sheet glass,ordinary quality and glazing with oil putty in square exc 0.5 sq. m in Each pane complete all as specified and directed |
| 79 | S&F mild steel framed work conforming to Fe.290.Gde-E-165 such as guard bars/grills,grating etc with end of bars shouldered and/or riveted or forged into spikes and similar works including one shop coat of zinc chromate primer complete all as specified and directed |
| 80 | S&F framed work as in doors or gates of angle or other section with gusset plates ,rails,braces etc complete drilled for fixing of steel gate sheeting or other covering,doors ,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering ,runing rails and guides ) and hanging also fastning and fixing complete all as specified and directed. confirming to FE-290 ( Gde E-165) complete all as specified and directed |
| 81 | M&L for cutting holes in brick walls in exc half brick and nexc one brick in cement in mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 complete all as specified and directed. |
| 82 | Taking down old steel tubing & connection including cleaning for refixing for 15mm bore pipe complete all as specified |
| 83 | Taking down old steel tubing & connection including cleaning for refixing for 20mm bore pipe complete all as specified |
| 84 | Taking down old steel tubing & connection including cleaning for refixing for 25mm or 32 mm bore pipe complete all as specified |
| 85 | S & F tubes medium grade, 15mm bore galvanised with all fittings and fixed to wall (concealed) or ceiling or laid in floors complete all as specified and directed |
| 86 | S&F tubes medium grade, 20mm bore galvanised with all fittings and fixed to wall or ceiling or laid in floors xomplete all as specified and directed. |
| 87 | S&F tubes medium grade, 25mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors xomplete all as specified and directed. |
| 88 | M&L for cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed |
| 89 | S& F in repairs Stop valve / Angle valve fancy type cast copper alloy chromium plated screwed down high pressure with capstan heads screwed both ends for iron pipe or for union and fixed 15mm bore complete all as specified and directed. |
| 90 | S& F in repairs Stop valve / Angle valve concealed type cast copper alloy chromium plated screwed down high pressure with capstan heads screwed both ends for iron pipe or for union and fixed 15mm bore complete all as specified and directed. |
| 91 | S& F in repairs 15 mm bore bib tap cast copper alloy, chromium plated, long body fancy type with capstan headed, screwed down, screwed for iron pipe complete all as specified and directed. |
| 92 | S&F in repair for 15mm chromium plated brass WHB mixer fancy type swan neck long nose- screwed down high pressure with or without lettered hot and cold and flynuts 15 mm dia complete all as specified and directed. |
| 93 | S&F in repair 15mm dia pillar tap cast copper alloy chromium plated capstan head screwed down high pressure with or without lettered hot or cold with long screw shank and fly nutt screw for iron pipe complete all as specified and directed |
| 94 | S&F in repair stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall Size 915mmx460mm with bowl size 410mm x330mm x 160mm complete all as specified and directed |
| 95 | S&F in repair staniless steel sink 1mm thick without drainage board for kitchen with plug , waste pipe , washers, including cantilever cast iron brackets , connecting union to waste pipe etc, overall size 495x420mm with bowl size 410x330x160mm complete all as specified and directed . |
| 96 | S&F soap dish, stainless steel approx size 160mm x 160mm x 90mm complete all as specified and directed. |
| 97 | S&F in repair PVC connection 450 mm long, 15mm size with PTMT nuts complete all as specified |
| 98 | S&F in repair PVC connection 600 mm long, 15mm size with PTMT nuts complete all as specified and directed |
| 99 | S&F in repairs 10 ltr PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle with flush pipe complete all as specified and directed |
| 100 | S&F in repairs grating doom 125mm dia PTMT with waste hole (Min weight 40 grms) complete all as specified and directed |
| 101 | S& F in repairs chromium plated shower rose 125 mm size and 15mm dia with or without swivel joints including fixing to pipe and union complete all as specified and directed |
| 102 | S&F 600x450 bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board of commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 103 | S & F in repairs towel rail 600 mm long and 20 mm dia brass chromium plated D type fixed with screws and wooden or plastic cleats complete all as specified and directed. |
| 104 | M&L for 100mm dia cast iron floor trap plain with grating including jointing and fixed with cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 105 | M&L for 75mm dia PTMT multi floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 106 | Taking down eaves gutters and rainwater pipes (any size or pattern ), including all fittings,heads,shoes,bends,swan necks etc.including cleaning or refixing or removal to store complete all as specified and directed. |
| 107 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches ,110 mm bore complete all as specified and directed. |
| 108 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches,75 mm bore complete all as specified and directed. |
| 109 | S&F PVC (SWR) bends any radius 110 mm bore complete all as specified and directed. |
| 110 | S&F PVC (SWR) bends any radius 75 mm bore complete all as specified and directed. |
| 111 | S&F, 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. |
| 112 | S&F, 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. |
| 113 | S&F in repair vitreous China squatting pan of pattern Orissa Pan , size 580 x440 mm white with integral foot rests any pattertn (excluding flushing cistern and flush pipe) complete including provn of lime concrete bedding connection to flush pipe , trap etc & making good complete all as specified and directed. |
| 114 | S&F in repair vitreous china wash down water closet pan Padestal pattern white excluding fixing bolts, flushing cistern and flush pipe with and incl 'P' or 'S' trap and making good to floor to match with existing all as specified and directed. |
| 115 | S&F in repair PTMT bottle trap ( with internal partition) 32mm bore having minimum water seal of 25mm(Minimum weight 32mm-260 gms complete all as specified and directed. |
| 116 | S& F in repairs Vitreous China wash hand basin, white, flat back, size 550mm x 400mm including brass coupling, mild steel brackets fixed to wall, with pedestal complete all as specified and directed. |
| 117 | S& F in repairs Vitreous China wash hand basin, white, flat back, size 550mm x 400mm including brass coupling, mild steel brackets fixed to wall, complete all as specified and directed. |
| 118 | S&F in repairs vitreous China bowl urinal flat back of size 465x355x265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern flush pipe and waste pipe) including connections to flushing pipe and out going pipes etc complete all as specified and directed |
| 119 | S & F in repairs Vitreous china urinal half stall type ,white including connection to flushing pipe and outgoing pipe complete all as specified and directed. |
| 120 | S&F CP waste fittings brass chromium plated for WHB/sink 32mm dia with long screws sinks and fly nuts , flange end bedded in red lead cement and other in fixed complete all as specified and directed. |
| 121 | S&F CP waste fittings brass chromium plated for sink 40mm dia with long screws sinks and fly nuts , flenge end bedded in red led cement and other in fixed all as specified and directed. |
| 122 | M&L for preparation of newly steel surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint complete all as specified |
| 123 | M&L for Preparation of newly wooden surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of pink primer com all as specified. |
| 124 | S& F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore of pipe complete all as specified and directed. |
| 125 | S & F in repair Gun-metal, globe or gate valves 20mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 126 | S & F in repair Gun-metal, globe or gate valves 25mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 127 | Dismantling exc 500 and n.exc 1000 ltr cpacity water tanks and removing to store complete all as specified and directed. |
| 128 | S&F for 1000 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 25 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed .Note : PVC tank shall be ISI marked and having Triple layers. |
| 129 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons laid in cement mortar complete all as specified and directed. |
| 130 | M & L for Machine pressed precast coloured concrete interlocking paver block M 35 grade any shape and size of 60mm thickness with grey cement and pigment complete all as specified and directed. |
| 131 | M&L for 50mm thick crushed stone sand/ river sand as in cushioning layer below interlocking paver tiles well compacted to a true surface complete all as specified and directed. |
| 132 | M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in Sub base of flooring complete all as specified and directed. |
| 133 | M&L for stone kerb of machine pressed coloured precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate, block of size 30cmX30cmX15cm finished at top bullnosed shape and finished surface even and smooth using coloured pigment and jointed in CM 1:6 struck finished, applying two coats of paints in zebra pattern as directed by Engr-in-Charge |
| 134 | S&F in repair Ball brass valves(25 mm), high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 135 | Roughening surfaces of old concrete floor/terrace by picking including taking down existing detoriated / decayed tar felt PCC tiles or any type of treatment including loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. and removing the scraped materials debris to a distance not exc. 50 m complete all as specified and directed. |
| 136 | M&L for wire brushing and cleaning top surface of tiles, lime terracing or cement concrete including flashing and junction of parapet etc and surface painting with a layer of blown bitumen of any penetration applied hot @1.70 kg per sqm.blinded with grit or pea size gravel @ 0.006 cu.m per sqm and lightly tampered (area of flashing shall be added to the roof area) |
| 137 | M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound @ 3 % by weight of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed. |
| 138 | M&L for APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric ( wt not less than 150 gms /sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 ltr/Sqm by torched application complete all as specified and directed. Four course roof treatment consists of as under :- (a) Applying one coat of bituminous primer conforming to IS-3384 @ 0.30 Ltr per sqm.(b) Laying of APP based membrane as specified thickness and weight.(c) Applying two coat of aluminium paint @ 100ml/sqm. |
| 139 | M & L Bitumastic gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical, complete all as specified and directed. |
| 140 | Supply only Integral water proofing compound all as specified and directed. |
| 141 | Preparation of old decorated plastered/un-plastered surfaces of any height of walls of any description, pillars, cornices by brooming washing, rubbing down and stopping of distempered and paintefd surface wire brushing, scrubbing down smoke, soot, mould moss and efflorescent, salts, trading oil and greasy spots and applying two coat of white wash (lime) complete all as specified and directed. |
| 142 | All as per item No 141 here-in-before but two coat on ceiling |
| 143 | All as per item No 141 here-in-before but two coats of oil bound distemper |
| 144 | M&L preparing surfaces of old wooden surfaces of any description not otherwise described over 10 cm width or girth and applying, one coat of synthetic enamel paint complete all as specified and directed. |
| 145 | All as per item No 144 here-in-before but not exc 10 cm width or girth on wooden surface |
| 146 | M&L preparing surfaces of old steel surfaces of any description not otherwise described but applying one coats of synthetic enamel paint on complete all as specified and directed. |
| 147 | All as per item No 146 here-in-before but not exc 10 cm width or girth on steel surface |
| 148 | M&L for applying two coats of interior emulsion over a coat of alkali resistant cement based primer over and including one coat of birla white wall care putty on wall/ceiling etc surfaces & smoothening the surfaces with sand/emery papers etc, including complete removal of existing treatment of any description before applying all as specified and directed. |
| 149 | M&L for removing existing treatment of any description completely by wire brush and washing the surface with water thoroughly and applying two coats of exterior acrylic emulsion base premium quality weather coat exterior anti fungal paint over a coat of primer plastered surfaces after giving oil putty treatment. Material will be apply with painting roller complete all as directed. |
| 150 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, holders, pendants, regulators, sockets etc and making good disturbed surface by using cement mortar, white cement, putty etc and match with existing surfaces of walls, floors etc complete all as specified as directed. |
| 151 | Taking down carefully any type of old unserviceable submain wiring with PVC/steel conduit surface / concealed or wooden battens etc and making good the disturbed surfaces to match with the existing surface complete all as specified & directed by Engineer-in-Charge. |
| 152 | Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn into and concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylum sheet/plastic laminated white sheet cover for mounting normal/modular switches, sockets, fan regulators fixed with CP screws with cup wahsers as required and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 with putty to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for One light Point/Fan point/Bell point controlled by one switch. Note:- (i) Cost for cutting chases and concealing the conduit pipe in existing wall is deemed to be included in the item rate quoted. (ii) Conduit will not be concealed in ceiling but fixed on ceiling surface only. |
| 153 | All as per item No 152 here-in-before but for one socket point 5 Amp controlled by one switch on same board. |
| 154 | All as per item No 152 here-in-before but for one socket point 5 Amp controlled by one switch on Independent board. |
| 155 | All as per item No 152 here-in-before but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge. |
| 156 | Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn into existing PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick plastic laminated white sheet cover for mounting normal/modular switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for for One light Point/Fan point/Bell point controlled by one switch |
| 157 | All as per item No 156 here-in-before but for one socket point 5 Amp controlled by one switch on same board. |
| 158 | All as per item No 156 here-in-before but for one socket point 5 Amp controlled by one switch on Independent board. |
| 159 | All as per item No 156 here-in-before but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge. |
| 160 | M&L for drawing the wire in with casing caping or conduit complete with point wiring with FRLS PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover or inner outer plates for modular switches with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed for one light/ Fan / Bell Point controlled by one switch. |
| 161 | All as per item No 160 here-in-before but for one socket point 5 Amp controlled by one switch on same board. |
| 162 | All as per item No 160 here-in-before but for one socket point 5 Amp controlled by one switch on Independent board. |
| 163 | All as per item No 156 here-in-before but drawing in with casing caping or conduit on surface all as directed complete with point wiring using 2.5 Sqmm (Nominal area)triple layer FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 2.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete. |
| 164 | M&L for Sub main wiring with two single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, concealed, medium grade not less than 20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Two run of 4 Sqmm & one run of 4.0 Sqmm cable and conduit shall be measured as one unit run. |
| 165 | M&L for sub main wiring with two single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, concealed, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6 Sqmm & one run of 6 Sqmm cable and conduit shall be measured as one unit run. |
| 166 | M&L for sub-main wiring with two single core PVC Insulated cable two run of size 10.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, concealed, medium grade not less than 25 mm dia with all conduit accessories and one run of 10.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Two run of 10 Sqmm & one run of 10 Sqmm cable and conduit shall be measured as one unit run. |
| 167 | M&L for sub-main wiring with four single core, multi stranded, PVC insulated, 1100 Volt grade, FRLS, cable with copper conductor of size 10 Sq mm in and including/drawing through rigid non metalic PVC conduit, concealed or on surface as per directed, medium grade not less than 25 mm dia with all conduit accessorie including continuous PVC insulated copper conductor single core earth continuity conductor of size 10 Sqmm connected common earth. Note :- 4x 10 Sq mm conductor cable, 1 x 10 Sq mm conductor earth continuity cable & PVC conduit shall be measured as one unit length |
| 168 | S&F call bell ding dong sound type suitable for AC 230 volt single pole complete all as specified & directed. |
| 169 | S&F switch bell push flush type suitable for 5/6 Amp 230 Volt of polycarbonate body complete all as specified & directed. |
| 170 | S&F switch piano flush type suitable for 5/6 Amp 230 Volt of polycarbonate body complete all as specified & directed. |
| 171 | S&F socket outlet 2 in 1, 5 Pin 5/6 Amp flush type of polycarbonate body complete all as specified & directed. |
| 172 | S&F Switch socket combination 5 in 1, 5 pin 5/6 Amps flush type universal of polycabonate body complete all as specified & directed. |
| 173 | S&F Switch socket combination 5 in 1, 5 pin 6/16 Amps flush type universal of polycabonate body complete all as specified & directed. |
| 174 | S &F Lamp holder, PVC/ polycarbonate type with back plate for angle holder all as per specified and directed. |
| 175 | S&F Ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified & directed. |
| 176 | S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc, ISI marked complete all as specified & directed. |
| 177 | S&F in replacement of modular switch 6-10 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed. |
| 178 | S&F in replacement of modular switch 16 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed |
| 179 | S&F in replacement of modular socket, 6A -2/3 pin combined 2 module, 230 volts AC as per existing model/ make complete all as specified and as directed. |
| 180 | S&F in replacement of modular socket, 6/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed . |
| 181 | S&F in replacement modular bell push switch piano, flush type, 6 Amps complete all as specified and as directed. |
| 182 | S&F in replacement modular fan regulator, 2 Module 4 step 180 W heavy duty 230 volts as per existing model/make complete all as specified and as directed. |
| 183 | S&F PVC rectangular block of size 200 x150 x50mm for mounting switches,sockets/fan Reg,etc with 3mm thick plastic laminated sheet cover complete all as specified and directed. |
| 184 | S&F in replacement of PVC insulated, unsheathed twin twisted copper conductor wire of nominal size 23/0.0076, 1100 volt grade, ISI marked, complete all as specified and directed. |
| 185 | Taking down old unserviceable DBs/Main switches any type/size complete with all accessories and remove from site all as directed. |
| 186 | Supply and Fixing Sheet metal enclosure for DBs suitable for MCBs/MCCBs to be Used, 4 way, VTP & N, double door type, 440 Volt, suitable for MCCBs income complete all as specified and directed.Note : MCBs/MCCBs will be Measured separately |
| 187 | Supply and Fixing Sheet metal enclosure for DBs when MCBs/MCCBs to be Used, 4 way, TP & N, double door type, 440 Volt, suitable for MCB/MCCBs incomer complete all as specified and directed. Note : MCBs/MCCBs will be Measured separately |
| 188 | Supply and Fixing Sheet metal enclosure for DBs when MCBs to be Used, 8 way, SP & N, double door type, 240 Volt. Note : MCBs will be Measured separately |
| 189 | Supply and Fixing MCCB, four pole, 160 Amp, 415 Volt, of breaking capacity 36 KA complete all as specified and directed |
| 190 | Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB), TPN, 63 Amps current carrying capacity in the DB complete with connection, testing and commissioning, complete all as specified and directed. |
| 191 | Supply and fixing 240V 10KA 'C' curve miniature circuit breaker (MCB), SPN, 40 Amps current carrying capacity in the DB complete with connection, testing and commissioning, complete all as specified and directed |
| 192 | Supply and fixing 240V 10KA 'C' curve miniature circuit breaker (MCB), SP, 6-32 Amps current carrying capacity in the DB complete with connection, testing and commissioning, complete all as specified and directed |
| 193 | Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed. |
| 194 | Supply and fix in repair rigid non metallic, heavy duty, PVC casing caping of size 32 x 16 mm with all accessaries such as couplers, lock nuts, saddles, hook, tees, bends, etc., complete all as specified and directed. |
| 195 | Supply & Fixing in repair of Smart bright Batten Series, LED luminaire using LEDs 20/22 watt min100 LM/watt, natural white(4000K)/ cool white (6500k), THD max 10 % ,CRI min 80 % with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output with wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification complete all as specified and directed |
| 196 | S&F in repair LED Mirror light fitting 2 ft tubelight 10 watt aluminum housing and integrated electronic driver THD max 10 % ,CRI min 80 % complete with fixing arrangements on wall all as specified and directed. |
| 197 | S&F in repair LED light fitting square 2'x2' 35/36 watt, 3000 lumen, Cool white 6500K/ Warm white 5700K, all as per direction, THD max 10 % ,CRI min 80 % warm white along with fixture Surface / Recessed /Pendent mounting LED luminaries with diffuser channel Luminaires ers, connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed by Engineer in charge. |
| 198 | Supply & fixing in repair LED light down lighter by recess or surface mounted 15 watt, cool white/warm white, circular/ Square, 1200 lumen with fixing arrangemnts on ceiling complete all as specified & directed. |
| 199 | Supply & fix in replacement of LED Security Light Luminaire 35 watt with 2500 or more lumen warm white, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver base.pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole/wall fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint complete all as specified and as directed. |
| 200 | S&F in repair LED Bulb 230V AC 9 watt warm white or yellow/cool day light 6500K as per the direction/requirement of site complere all as specified and directed by Engineer-in -charge. |
| 201 | Taking down carefully ceiling fan/exhaust fan any type, size or make with cable and all accessoreis remove from site to store for repair/overhaulling complete all as specified and directed. |
| 202 | Overhauling of Ceiling fan 1200/1400 mm sweep by opening and cleaning rotor, bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and coonecting on its existing position and testing on completion all as specified and as directed. |
| 203 | Dismantling of Ceiling fan 1200/1400 mm sweep along with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding, ball bearing, gun metal bush etc complete to carry out the following repairs :- (a) Removing of burnt out fan winding and rewinding it with suitable size of Copper enamelled wire (weight of copper coil shall be same as per dismantled fan), heating and varnishing as per manufactures design & direction. (b) Re-assembling the ceiling fan by fixing only serviceable spare parts complete to give designed air delivery including greasing, oiling etc, reconnecting / hanging in original position, reconnecting the electric cables and testing complete, all as directed. Note : Items required to be replaced will be measured and paid separately in relevent items as supply only. |
| 204 | Overhauling of exhaust fan 300 mm to 400 mm sweep (steel body/PVC body) after opening and cleaning rotor, bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and coonecting on its existing position and testing on completion all as specified and as directed. |
| 205 | Dismantling of exhaust fan 300/400 mm sweep, unscrewing the body parts, taking out starter, rotor winding, ball bearing, gun metal bush etc.,removing of burnt out fan winding and rewinrng it with suitable size of Copper enamelled wire (weight of copper coil shall be same as per dismantled fan), heating and varnishing as per manufactures design & direction, re-assembling the fan by fixing only serviceable spare parts complete to give designed air delivery including greasing, oiling etc, refixing the same in original position, reconnecting the electric cables and testing complete, all as directed. Note : Items required to be replaced will be measured and paid separately in relevent items as supply only. |
| 206 | Supply only fan condensor 2.5 MFD, 230 volts, 50 Hz AC confirming to IS 1709 |
| 207 | Supply only fan condensor 4 MFD, 230 volts, 50 Hz AC confirming to IS 1709 |
| 208 | Supply only Gun metal bush 15 mm size as per sample. |
| 209 | Supply only split pin of size 25 mm long. |
| 210 | Supply only Ball bearing of size 6201/6202/6203 as per sample. |
| 211 | Supply only 'U' shape shackle clamp assembly incl. checknut, bolts, screws, washer, lock nut, rubber reel etc.and connecting complete all as directed. |
| 212 | Supply only fan hook made out of steel bar as per sample. |
| 213 | Supply, installation, testing and commissioning of 630A, 4-Pole, 415V Automatic Transfer Switch (ATS) with enclosure complete with microprocessor controller, motorized mechanism, mechanical and electrical interlocking, IP54 enclosure, all accessories, control wiring, cable terminations, testing, commissioning and certification, complete all as specified and directed. |
| 214 | Material & Labour for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (Earth pit not less than 2.25 m deep below the normal ground level with top edge of earth plate not less than 1.5 m below normal ground level) connected to galvanised earth wire 4 mm dia as earth wire or earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in Electrical Plate No. 3 of SSR-2009 (Part-I) including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, MS Sheet funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth wire including PCC pit 1:2:4 type B-1 using 20mm graded crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm # TMT bars @ 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-charge and testing for required value complete. Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed to be included in unit rate quoted. |
| 215 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation of poles/stays/cables etc and getting out in any type of soil,complete all as specified and as directed. |
| 216 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers n.exc 25cm complete all as specified and as directed. |
| 217 | Removing excavated material n.exc 50m and depositing were directed at a level n.exc. 1.5m above the starting level complete all as specified and as directed.. |
| 218 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed by Engr-in-Charge. (Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I) |
| 219 | M & L for Fly Ash bricks Sub-class 'B' locally available laid flat in trenches over sand cushioning for cable protection complete all as speciffied and directed. |
| 220 | Supply and fixing 50 mm dia GI tubing light grade ISI marked fixing to pole with suitable clamps / laid under floor/road for protection of cable including complete all as specified and directed. |
| 221 | Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe, floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material of any size complete as directed (Excavation/earth work shall be measured & paid separately under relevant item of this schedule) |
| 222 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, complete all as specified and as directed. |
| 223 | M&L for cutting the existing road/pavement/PCC hard standing including taking out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road/PCC hard standing all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately. |
| 224 | Schedule of credit amount of Rs 1,39,627.00 to be deducted during AOC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender