Tender For Repairs/ Replacement And Renewal Of Lt/Ht Protection Devices And Switch Gears At installation Baaz, 172 Ta Bn And Its Adjoining Area Under Ge C Bell Bay
Tender Value
64.99 Lakhs
Estimated cost
Bid Submission
09 Oct 2026
27 days left
EMD
1.22 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nicobars → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs/ Replacement And Renewal Of Lt/Ht Protection Devices And Switch Gears At installation Baaz, 172 Ta Bn And Its Adjoining Area Under Ge C Bell Bay
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. n exc 10 sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete as specified and as directed by Engineer-in-Charge. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil all as specified and directed by Engineer-in-Charge. |
| 3 | Removing excavated materials (soil) not exc. 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed by Engineer-in-Charge. |
| 4 | S&F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II having outer dia 120 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed by Engineer-in-Charge. |
| 5 | M&L for road cutting for laying of LT UG cable/galvanised iron pipe complete and making good all as specified and directedby Engineer-in-Charge. |
| 6 | S&F GI pipe 50mm bore light grade with all fittings laid in trenches/on wall / on poles etc/ for protection complete all as specified and directed by Engineer-in-Charge. |
| 7 | S&F GI pipe 100mm bore light grade with all fittings laid in trenches/on wall / on poles etc/ for protection complete all as specified and directed. |
| 8 | Supply, lay, connect test and commissioning of 3.5 core, 300 Sqmm, 1100 Volts grade XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminum conductor laid in trench/under ground/wall/surafce/tunnel/duct including taking out unserviceable burnt out cable complete all as directed by Engineer-in-Charge. |
| 9 | Supply, lay, connect test and commissioning of 3 core, 95 Sqmm, 11000 Volts grade(earthed) XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminum conductor laid in trench/under ground/wall/surafce/tunnel/duct including taking out unserviceable burnt out cable complete all as directed by Engineer-in-Charge. |
| 10 | Supply, lay, connect test and commissioning of 3 core, 120 Sqmm, 11000 volts grade(earthed) XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminum conductor laid in trench/under ground/wall/surafce/tunnel/duct including taking out unserviceable burnt out cable complete all as directed by Engineer-in-Charge.NOTE for item 8, 9 & 10- Excavation, earthwork, GI pipe, etc. will be measured and paid under appropriate Items above |
| 11 | M&L cement concrete 1:4:8 (40mm graded aggregate) as lean concrete in foundation of poles, stay assembly, etc., including formwork (as/if required), complete all as specified and as directed by Engineer-in-Charge. |
| 12 | M&L cement concrete 1:2:4 (20mm graded aggregate) as in coping of poles, etc. and finishing the concrete surfaces fair and even without using extra cement including necessary formwork required at site(s), complete all as specified and as directed by Engineer-in-Charge. |
| 13 | Supply & erecting steel tubular swaged pole type 410-SP-55 (11.0 metre long) including cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws including applying two coats of black bituminous paint internally and externally from bottom end of pole upto PCC coping and applying with two coats of aluminium painting over a coat of aluminium primer (externally from top of coping) including writing MES pole No.with synthetic enamel paint (first grade/quality), complete all as specified and as directed by Engineer-in-Charge.NOTE : Earthwork, cement concrete, etc. will be measured and paid under approprite Items. |
| 14 | M&L cross-arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated/ directed and inclusive of one coat of aluminium primer one under coat and one finishing coat of aluminium paint, complete all as specified and as directed by Engineer-in-Charge. |
| 15 | S&F aluminium conductor steel reinforced (ACSR) (sizes as ordered) with permissible sags and providing Jumper, etc., fixing on electric poles and binding to Insulators with aluminium binding wire as in OH conductors including stringing, tightening, etc., complete all as specified and as directed by Engineer-in-Charge.NOTE : Cost of binding wire is deemed to be included in the quoted unit rate. |
| 16 | Supply and fix lightening arrestor non linear resistor type conforming to IS 3070 (part-3) 1993 complete, line discharge class-3, nominal discharge current 10KA (peak) , 12KV rated system, voltage peak value high current implus of 4/10 mocro Sec. wave shape 100 KA (peak) assembly suitable for 11 KV ,long duration descharge class-II with insulation level 28/75 KV and mounted on hot dip galvanized steel structure including all clamps, nuts, bolts and washers and connecting to earth with 4 mm dia GI wire including removal of existing unservicable one complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and installation in repair of 11 KV, 630 Amp load break switch with 200 Amp DO set and earth switch mounting on 2 pole structure with mechanically operated arrangement from ground and locking system complete including dismanting old unserviceable break switch of any description, complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 18 | Supply and installation in repair of 11 KV, 630 Amp load break switch with 200 Amp DO set and earth switch mounting on 2 pole structure with mechanically operated arrangement from ground and locking system complete including dismanting old unserviceable break switch of any description, complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 27 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 30 daysTender Documents