Tender for Repair/Replacement Of Certain E/M Works Of Internal Wiring And Connecting Works For North C , East C , West C And South C Under Age(I) Mffr.
BOQ
| Sl. No. | Item Description |
| 1 | M&L for replacement of Point wiring for one light point/fan point/exhaust fan/bell point with FRLS copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and sheathed of size 2.5 Sq mm single core multistand in and including PVC concealed conduit Medium class 25 mm dia ISI marked with all fittings such as tees, bends, MS sunken box, modular plates as per site requirement for one fan/ light/Exhaust fan or 5/15Amps socket or bell/buzzer point controlled by one switch including provision of 2.5 Sqmm PVC insulated sheathed copper conductor cable, single core multistand as earth wire to common earth & connecting to earth dolly complete all as specified and as directed by Engineer-in-Charge. |
| 2 | All as per item No 1.00 here-in-before but socket point on the 5/6A independent board with other switches complete all as specifed and as directed by Engineer - In - Charge. |
| 3 | All as per item No 1.00 here-in-before but socket point on the same board with other switches complete all as specifed and as directed by Engineer - In - Charge. |
| 4 | All as per item No 1.00 here-in-before but cable of 4 Sq mm for 15 Amp switch socket outlet on independent board including provision of 4 Sqmm PVC insulated unshethed multistranded copper conductor as earth wire complete all as specifed and as directed by Engineer - In - Charge. |
| 5 | M&L for replacement sub main wiring in PVC conduit/casing-capping with 2 single core 6 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 6 sqmm copper conductor cable connected to common earth and earth dolly complete and including PVC Cassing and Capping complete all as specifed and as directed by Engineer - In - Charge. (Note: two run of 6 sqmm with one run of 6 sqmm earth wire and conduit/casing-caping will be measured as 1 unit. |
| 6 | All as per item No 5.00 here-in-before but of size 4 sqmm with earth wire of 4 sqmm. |
| 7 | All as per item No 5.00 here-in-before but of size 2.5 sqmm with earth wire of 2.5 sqmm. |
| 8 | S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1Nos MCB 20Amps capacity complete all as specified and as directed by Engr-in-charge. |
| 9 | Taking down any size and any capacity Exhaust fan, ceiing fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and as directed by Engr-in-charge. |
| 10 | M&L for Refixing of exhaust fan, taking down vide item ser No-9.00 and connecting up with 3 core of flexible cable of size 1.5 sqmm after make it serviceable by replacing all defective parts like winding coils, ball bearing, motor housing, stator, rotar, shaft etc as per requirement and overhauling of exhaust fan complete all as specified and as directed by Engr-in-charge. |
| 11 | M&L for Refixing of Ceiling fan,taking down vide item ser No-9.00 and connecting up with 3 core of flexible cable of size 1.5 sqmm after make it serviceable by replacing all defective parts like motor housing,stator,rotar,shaft,winding coils,ball bearing etc as per requirement and overhauling of ceiling complete all as specified and as directed by Engr-in-charge. |
| 12 | Supply and fixing PVC fresh air fan of size 250 mm sweep and connecting up including three core PVC insulated multi stranded copper conductor cable of size 1.5 Sqmm wire from ceiling rose/connector to fan of length not less than 1.0 meter complete all as specified and as directed by Engr-in-charge. |
| 13 | Supply and fixing PVC fresh air fan of size 300 mm sweep and connecting up including three core PVC insulated multi stranded copper conductor cable of size 1.5 Sqmm wire from ceiling rose/connector to fan of length not less than 1.0 meter complete all as specified and as directed by Engr-in-charge. |
| 14 | Supply and fixing PVC fresh air fan of size 150 mm sweep and connecting up including three core PVC insulated multi stranded copper conductor cable of size 1.5 Sqmm wire from ceiling rose/connector to fan of length not less than 1.0 meter complete all as specified and as directed by Engr-in-charge. |
| 15 | M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing the same upto 30 cm above normal ground level with plug at top including pipe fittings etc complete and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I complete all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information |
| 16 | M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing the same upto 30 cm above normal ground level with plug at top including pipe fittings etc complete and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I complete all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysOct 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender