Communications and Information Technology Government Departments Closing in 9 days TDR #57439295

Tender For Repairing Of Electrical Installation And Other Electrical Works At Various Telephone Exchange Buildings/Bts Sites Under Sirsa Distt. (Ch To repair maintenace Of Ems Under Hisar Ba)

Issued by Government Departments · Sirsa, Haryana
Tender Value
7.93 Lakhs
Estimated cost
Bid Submission
23 Sep 2026
9 days left
EMD
15860
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sirsa → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairing Of Electrical Installation And Other Electrical Works At Various Telephone Exchange Buildings/Bts Sites Under Sirsa Distt. (Ch To repair maintenace Of Ems Under Hisar Ba)

BOQ

Name of Work:- Repairing of Electrical Installation and Other Electrical works at various Telephone Exchange buildings/BTS sites under Sirsa Distt. (Ch to R/M of EMS under Hisar BA)
Sl. No. Item Description
1Replacement of existing 36/40W Fluorescent defective /faulty tube fittings with 4'-1x20/22Watt prewired PVC Batten type LED fitting complete and fixing directly on ceiling / wall i/c making connections with 1.5 sq.mm. PVC insulated copper conductor, cable as reqd.(M/s Bajaj/Philips/Havell's/Surya/Crompton).
2Supplying and fixing of following fans i/c making connections testing etc. complete as required.( make- CROMPTON AND OTHER APPD MAKES)
3Ceiling Fans (48''sweep)
4Exhaust Fans with metallic body (300mm sweep)
5Supplying and fixing of following heavy duty wall mounted fans with metal body i/c making connections testing etc. complete as required.(approved make)
6Wall Fan with metallic body (300mm sweep)
7Repairing of following fans i/c dismntalling the same from site , rewinding the same with super enamelled copper wire of suitable gauge, Varnishing etc., replacement of balL bearings/ greasing etc. and reinstallation of the same back at site after repairing, making connections testing etc. as required.
8Ceiling Fans (48''/56'' sweep)
9Exhaust fan (18'' Sweep)
10Wall fans (16'') sweep
11Replacement of following defective/burnt items of Electrical installation/MCB DB/wiring /Panels i/c dismentlling the defective/burnt one , making connections testin etc. as required.
12100Amps Kit Kat Fuse (Porcelein type) ISI Mark
13200 Amps Kit Kat Fuses (Porcelein type) ISI Mark
1463AMPs 4 Pole isolator (Approved Make)
156-32Amps SPMCB(Approved Make)
1632Amps DP MCB(Approved Make)
1730/45W LED coumpound light fitting (IP 66 rating) suitable for 230V 50HZ AC Supply (M/s PHILIPS / OTHER APPD MAKES)
1836 Watt Electronic Choke (M/s Bajaj/Philips/Havell's/Surya /Crompton)
19Starter for 40W Fluorescent tube fitting ISI Mark
204'-36 W fluorescent tube rod (M/s Bajaj/Philips/Havell's/ Surya /Crompton)
21LED -9 W,230V-50HZ rating (M/s Bajaj/Philips/Havell's/ Surya/Crompton)
22Supplying and drawing 2x1.5 Sqmm PVC insulated copper conductor cable ISI Mark
23Supplying and drawing 2x4 Sqmm PVC insulated copper conductor cable ISI Mark
24Supplying and drawing 2x6 Sqmm PVC insulated copper conductor cable ISI Mark
2520mm dia PVC conduit pipe a/w accessories i/c fixing the same on wall surfacefor covering various wires
262.5Mfd Capacitor for ceiling Fan ISI Mark
27Electronic Fan Regulator (ISI Mark)
285/6Amps Piano type switch (Approved Make)
295/6 Amps 6 Pin Piano type Socket (Approved Make)
3015/16 Amps Piano type Switch (Approved Make)
3115/16 Amps 6 Pin Piano type Socket (Approved Make)
32100 Amps 3 Pole 10 KA MCCB (Approved Make)
33100 Amps 4 Pole 10 KA MCCB (Approved Make)
34MS Enclosure fabricated out of 16 SWG MS Sheet having sufficient space to house 100/200 Amps 3phase MCCB/Kit Kat fuses Complete as required.
35Extension board with 5 Nos 5 way 6Amps multi sockets and common switch with five meters PVC insulated sheathed copper conductor flexible cable of 1.1 kVA Grade complete as required. (ISI Marked)
3663Amps Rotary type Changeover cum selectot switch 3 Position) (M/s Vaishno/SS make)
37Contactor (MN -A1 OR Similar compatible model) -10 A suitable for 3 Phase 415V AC mains supply
38Replacement of following capacity Changeover Switches i/c dismentalling the burnt/faulty one making connections testing/commissioning etc. as required
3963 Amps 415 V rating three phase Changeover switch housed in sheet steel enclosure with side handle (Approved Make)
40100 Amps 415 V rating three phase Changeover switch housed in sheet steel enclosure with side handle (Approved Make)
41100 Amps 415 V rating three phase front Operated Changeover switch for existing MV Panel (Approved Make)
4263 Amps 415 V rating three phase front Operated Changeover switch for existing MV Panel (Approved Make)
43Repairing of 3 HP Monoblock Pump and 3 Phase Motor of Monoblock type water pump motor set i/c dismentalling the same from site,checking and tracing out the faults , checking the windings continuity , rewinding the same with super enamelled copper wire ,varnishing etc. replacement of bearings /bush /greasing and servicing of pump i/c replacement of worn out bush/impeller and other defective parts for smooth functioning , reassembling the same and reinstallation back at site making connections complete testing commissioning as required.
44Wiring for light point/Fan point/exhaust fan point /call bell point with 1.5 Sqmm FRLS PVC insulated Copper conductor cable in surface/recessed medium class PVC conduit with piano type switch phenolic laminated sheet suitable size MS box and earthing the point with 1.5Sqmm FRLS PVC insulated copper conductor cable as required - GROUP-A
45Replacement of following way sheet steel MCB DB 240V/415 V on surface/recess complete with tinned copper busbar neutral busbar earthbar din bar intercoonections powder painted i/c earthing etc. as required.
464way (4+12) double door Triple pole and neutral sheet steel MCB DB 415V rating
4712way double door Single pole and neutral sheet steel MCB DB 240V
48Replacement of following size faulty/ damaged aluminum armoured PVC insulated PVC sheathed/XPLE Power cable ISI mark of 1.1KV Grade etc as reqd -
492x6 Sqmm
503-1/2x25 sqmm
513-1/2x35 Sqmm
523-1/2x50 Sqmm
53Checking, tracing out and removing the electrical installation faults in all electrical equipments such as MV Panel , KIT KAT , TPN SWITCH , MCBDB/SWITCH BOARD/POWER PLUG & any other equipment i/c carbon cleaning of all phase connections , neutral connection , cleaning & tightning of all earthing connections [AC and DC earths ] i/c replacement of thimble , replacement of faulty wires , providing proper tapes with AC Load balancing & cleaning of panels with blower at TE/BTS site as per following distances from district Main Exchange under sirsa and restoring the Electrical mains/DG Supply as per site requirements.
54Upto 25KM Distance
5525Km - 50KM distance
5651 Km and above distance
57Refilling of following Capacity Fire extinguishers installed at various TE/BTS Sites of Sirsa i/c dismentalling the same from site for refilling,Checking the weight/Pressure of Fire extinguisher, i/c taking the same from site to the Refilling Plant, Testing the same and refilling upto the recommended pressure , Pasting the Refilling Schedule slip/Tag , bringing back the refilled Fire extinguisher at site and i/c Supplying (if required)/fixing the same on wall with suitable clamp complete as required.
584.5 KGS CO2 type Fire extinguisher
595/6KG Capacity ABC type Fire Extinguisher
60Replacement of following defective items of fire extinguishers i/c dismentalling the existing defective/worn out ones ,refixing the new items properly, testing the operation of same at site as requird.
61Rubber Hose (One meter length)
62Pressure gauge of ABC type Fireextinguisher
63Brass Valve of Fire Extinguisher
64Replacement of following size damage/defective GI B class pipe i/c replacement required acessories plumbing work for 3HP/5HP pump complete as reqd. (Approved Make)
65Replacement of following defective parts in 3HP/5HP pump i/c replacement of required acessories i/c plumbing work complete as reqd. (Approved Make)
6680 mm dia Foot valve
6750 mm dia Foot valve
6825mm Gate Valve for water Pipeline
6940mm Gate Valve for water pipe line
70Supplying & fixing of flush mounted analog time switch suitable for 230V, 24 Hrs programable, suitable for intermitent ON/OFF for Exhaust fan i/c making electrical connections etc. complete as required. (L&T or Selec Make)
71Making opening for installation of Exhaust fan i/c Cutting the shelter/ Brick wall with the help of suitable cutter/manually , repairing the damages ,Finishing the cut portion and throwing the malba/scrap material away from the site, Plastering etc. all complete as required.
72Supplying, Installation, Testing and Commissioning of Maintenance free Chemical earth station as per latest RDSO specifications and as per BSNL Approved makes , consisting of :-a) Copper bonded steel electrode of 3 mtrs long, 17 mm dia with copper bonded thickness of minimum 250 microns and UL listed and marked - 1No.b) Maintenance free, Environmental friendly, Mineral compounds, Semi soluble, non corrosive, conductivity improving material of RDSO approved) =30 Kgc) Poly-plastic, Heavy Duty, weather-proof, environmental free earth pit chamber with cover size about top dia 250mm bottom 330mm and height 260mm, Heavy duty of 7 TON load capacity, the base unit should have knockouts for interconnection of strips. Note - Note :- This earth value should be less than one ohm .
73Providing and fixing 25x5mm GI strip on surface /recess complete as required
74Providing and fixing the new Earth pit chamber for following type earthing etc complete as required.(6\\"above the ground level) -
75Earth Pit Cover of existing Chemical earth i/c provide the new poly plastic, Heavy Duty, weather-proof, environmental free earth pit chamber with cover suitable for size about the base unit should have knockouts for interconnection of strips and making masonry work etc is tobe done
76Earth Pit Cover of existing GI / Copper plate earth i/c Providing and Making of earthing PIT of 450mmx450 mm size along with earth pit cover of size 300x300 mm for the existing copper plate/GI plate/Chemical gel GI Earthing and chemical gel copper earthing i/c supplying of all the material required for earth pit i.e. bricks , cement , sand etc plastering finishing complete asper requirementat site.
77Supplying and fixing of following Square type Heavy Duty capacitor in a suitable place in MV panel or on wall i/c making connections with suiable size of copper wires etc. complete as required.
781 KVAR TO 5 KVAR
79Less on a/c of dismantled material . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57439295
AUTHORITY Government Departments
TENDER VALUE 7.93 Lakhs
LAST DATE 23-09-2026
Authority
Authority Name Bharat Sanchar Nigam Limited
Work Description Tender for Repairing Of Electrical Installation And Other Electrical Works At Various Telephone Exchange Buildings/Bts Sites Under Sirsa Distt. (Ch To repair maintenace Of Ems Under Hisar Ba)
Basic Detail
Tender No 56(5)/EEE/BSNL/ED/2026-27/22
Bidding Type Tender
Location
City Sirsa
State Haryana
Key Dates
Publish Date 10 Sep 2026
Submission Date 23 Sep 2026
Open Date 25 Sep 2026
Finance
Tender Value 7.93 Lakhs
Tender Fee 590
EMD 15860
Exemption Available
Document List
BOQ_338675.xls
f3beba7d-3624-4735-ac09-840c807b62f4.html
Tendernotice_1 (10).pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_338675.xls

html

f3beba7d-3624-4735-ac09-840c807b62f4.html

pdf

Tendernotice_1 (10).pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders