Public Administrative Department Local Bodies Closing in 7 days TDR #57438233

Tender For Replacement Of Old Fittings & Fixtures At Community Center Kaka Nagar And Community Center Laxmi Bai Nagar And Schools Under Lok Nayak Bhawan And Kidwai Nagar Wiring Enquiry New Delhi

Issued by Local Bodies · Delhi, Delhi
Tender Value
36.27 Lakhs
Estimated cost
Bid Submission
18 Sep 2026
7 days left
EMD
72556
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Old Fittings & Fixtures At Community Center Kaka Nagar And Community Center Laxmi Bai Nagar And Schools Under Lok Nayak Bhawan And Kidwai Nagar Wiring Enquiry New Delhi

BOQ

Name of Work:- Replacement of old fittings & fixtures at community center kaka Nagar and community center Laxmi Bai Nagar and schools under Lok Nayak Bhawan and Kidwai Nagar wiring enquiry New Delhi
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required Group C LP-38
2Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
32 X 16 sq. mm + 1 X 6 sq. mm earth wire
4Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
6Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
7LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) 135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).24 -26wattIS code 10322
8Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)IS 374:2019
9LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)36 watt IS code 10322
10Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way Double Door
11Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
12LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy ≥105 <120lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 52 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management:heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). IS code 1032250 watt
13SITC of 18-20 watt LED Post Top Lantern made out of die cast aluminum base and spun aluminum Top with fitted with LED pt Module. Power LED's are mounted directly on inbuilt heat sink. A UV stabilized thermoformed P.C diffuser is provided for glare free lighting with IP-67 Protection and CCT 5700-6500K, CRI>70, Constant current driver suitable for 100-280V AC working range, LM80 certified, Internal wiring Teflon insulated, Cu. Conductor, Efficacy ≥85 im/w Warranty 2 years. Including fixing of GI Pipe of 2\\" dia for installation of LED post top lantern with allied accessories, connection with 2.5 sq.mm copper wire, earthing etc as per BIS. Make:- Syska/ Philips / OsramIS code 10322
14Supply installation, Testing & Commissioning of 15 watt LED down lighter round shape 230 V, 50 Hz. Size 150mm(IS code 10322)
15SITC of wall mounted fan of speed 1280 rpm,400 mm sweep , 3 blades, speed setting, suitable for single phase 230 volts,50 hz with 2 years warranty ,Make: Philips/Havell's Crompton (IS code 555)
16Supply installation, Testing & Commissioning of 24 watt LED down lighter square shape 1X1 ceiling light panels cool temperature 6500 k 230 V, 50 Hz. IS code 10322
17SITC of 200 amp 4 pole manual type Changeover switch 415 Volt, 3 phase heavy duty metal box heavy-duty electrical equipment used to safely and seamlessly transfer a building's electrical load between two power sources, having size 37 cm × 35 cm × 18 cm make Havells/L&T/ABB (IS code 13947 (Part 3) / IEC 60947-3)
18Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
19Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required
20Supply and laying 6 SWG GI wire at 0.50 mtr below ground level for conductor earth electrode including connection/termination with GI thimble etc as required
21Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door (IS code 13032)
22Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required100 amp (IS code 13032)
23Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amp(IS code 13032)
24Deduct - Less Credit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57438233
AUTHORITY Local Bodies
TENDER VALUE 36.27 Lakhs
LAST DATE 18-09-2026
Authority
Authority Name New Delhi Municipal Council
Work Description Tender for Replacement Of Old Fittings & Fixtures At Community Center Kaka Nagar And Community Center Laxmi Bai Nagar And Schools Under Lok Nayak Bhawan And Kidwai Nagar Wiring Enquiry New Delhi
Basic Detail
Tender No 41/EE (BM-II) E/26-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 09 Sep 2026
Submission Date 18 Sep 2026
Open Date 18 Sep 2026
Finance
Tender Value 36.27 Lakhs
Tender Fee Ref. Documents
EMD 72556
Exemption Not Available
Document List
9de22a53-e941-49d7-abf2-88529d1282ee.html
BOQ_397576.xls
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

9de22a53-e941-49d7-abf2-88529d1282ee.html

xls

BOQ_397576.xls

pdf

Tendernotice_1 (19).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders