Tender For General-V.R Puram Lis-Improvement To Lift Irrigation Schemes In Mi Section Chalakkudy - Reconstruction Of V.R Puram Lift Irrigation Scheme Pump House-General Electrical Work
Tender Value
4.14 Lakhs
Estimated cost
Bid Submission
22 Sep 2026
11 days left
EMD
10371
Bank guarantee accepted
Document Fee
915
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thrissur → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for General-V.R Puram Lis-Improvement To Lift Irrigation Schemes In Mi Section Chalakkudy - Reconstruction Of V.R Puram Lift Irrigation Scheme Pump House-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Electrification |
| 2 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 3 | OD129778/2026-2027:Supply and fixing of 9W LED bulb |
| 4 | OD120450/2026-2027:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. LED light fittings made of CRCA sheet with 0.5mm thickness complete with all accessories and lamps etc. 1200 mm 20 W T8 LED tube , having total efficiency of 100 Lumen /watt with 4 feet Aluminium extrusion in the tube for better heat dissipation,, THD < 20% PF> 0.95 ( LM 79 & LM 80 Certificate from NABL should be submitted ) |
| 5 | OD129791/2026-2027:Supplying and fixing Bulk head fitting of 7/9 W on wall/ceiling including connection etc. as required. |
| 6 | OD129822/2026-2027:Supply Conveyance, installation, testing and commissioning of 35W LED STREET LIGH LED, efficacy >=120 Lm/ watt, IP 66 street light fitting with die-cast aluminium housing, polycarbonate cover complete with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 7 | 90.3.17.2:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.40 mm dia GI pipe |
| 8 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 9 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 10 | 19.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: |
| 11 | 90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. |
| 12 | OD130272/2026-2027:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. - 225 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C. |
| 13 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 14 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 15 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 16 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 17 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 18 | 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 19 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 20 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 21 | 1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm |
| 22 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 23 | 1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm |
| 24 | OD131587/2026-2027:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single corecopper conductor cables conforming to IS 694 part I 1990 in the existing surface /recess conduit as required including giving necessary connections of the followingsizes.35.00 sq.mm 6 Run |
| 25 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 26 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 27 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 28 | OD120821/2026-2027:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current Up to 300milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 29 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 30 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 31 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 32 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 33 | 2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N |
| 34 | 2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N |
| 35 | 2.1.5:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.160 Amp TP&N |
| 36 | OD129887/2026-2027:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to relevent IS Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 37 | 90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. |
| 38 | 90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet |
| 39 | OD131607/2026-2027:Supplying and installation of supports, anchor bolts etc made out of suitable size single section angles/flats etc as required including painting with 2 coats of synthetic enamel paint |
| 40 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 41 | OD131897/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/ (part I)/1988 for XLPE of following size on wall surface as required. 3x10 sqmm (clamped with 1mm thick saddle) |
| 42 | OD131964/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required.. 3.5x240sqmm (clamped with 40x3mm MS flat clamp) |
| 43 | OD131906/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required..3x50sqmm (clamped with 25x3mm MS flat clamp) |
| 44 | OD131909/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/ (part I)/1988 for XLPE of following size on wall surface as required. 4x10 sqmm (clamped with 1mm thick saddle) |
| 45 | 14.15.1:Supplying and laying of following size DWC HDPE pipe ISI marked along with allaccessories like socket, bend, couplers etc. conforming to IS 14930, Part Ilcomplete with fitting and cutting, jointing etc. in the existing trench, complete asrequired.63 mm· dia (OD-63 mm & ID-51 mm nominal) |
| 46 | OD354636/2025-2026:Supplying and clamping the following sizes of corrugated pvc flexible conduit withnecessary compression gland with locking ring and check nut at terminationpointed using suitable size GI/painted MS saddles spacing not exceeding 60 cmson surface including making good the damages.25 mm dia . |
| 47 | OD121003/2026-2027:Supplying and clamping the following sizes of corrugated pvc flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI/painted MS saddles pacing not exceeding 60 cms on surface including making good the damages.50 mm dia |
| 48 | 90.12.24.3:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm |
| 49 | 90.12.24.7:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.35 sq mm |
| 50 | 9.1.7:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm) |
| 51 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 52 | 9.1.11:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 50 sq. mm (32mm) |
| 53 | 9.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) |
| 54 | OD354644/2025-2026:Supplying and providing earth clamps for siemens/ tropodur type cable glands ofsuitable length and other dimensions noted along with each size ofglands for thefollowing sizes of cables as required.(4 sq - 16sq mm with 12 mm wide x 1.20 mmthick clip) |
| 55 | OD354641/2025-2026:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following size of cables as requiered(25sq mm- 95 sqmm with 20 mm wide x 1.2 mm thick clip) |
| 56 | OD354654/2025-2026:Supplying and providing earth clamps made out of copper strips of the followingsizes including cutting and bending the flat exactly to the shape of thegland,drilling necessary holes for nut & bolt, tinning the points of contacts and givingconnections to the main earthing system as required.(25 x 3 mm for earthingglands of size 240 sq mm to 300 sq mm) |
| 57 | OD131634/2026-2027:Supply and fitting Digital Multifunction meter to read V, A, F, 3 phase accuracy class 1 |
| 58 | OD131635/2026-2027:Supply and fixing LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Color. |
| 59 | OD131636/2026-2027:Supply and fixing LED indicators for all voltage ranges - Blue Color. |
| 60 | OD130563/2026-2027:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) |
| 61 | OD130044/2026-2027:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 62 | 90.16.5.5:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) |
| 63 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 64 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 65 | 5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 66 | 5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 67 | 90.14.24.24:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.12.5 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors. |
| 68 | 90.14.24.2:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. |
| 69 | OD130081/2026-2027:Supply and installation of dust and vermin proof wall mounting , sintex make meter box of size 850X350X230 mm GSMB 8535 ( IP65 ) or equivalent suitable for fixing KSEB meter,fuse units, CT etc hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment knock out for cable entry and exit IP65 with neutral CT as required including fixing it and making good the damages etc. as required. providing vision panel for the meter compartment knock out for cable entry and exit IP65 with neutral CT as required including fixing it and making good the damages etc. as required. |
| 70 | OD354655/2025-2026:Supply , Conveyance and fitting 315/400 A, 2 Way neutral links in the existing Meter box. |
| 71 | OD354656/2025-2026:Supply , Conveyance and fitting315/400A, HRC Fuse Base with suitable HRC Fuse link in the existing Meter box |
| 72 | OD131649/2026-2027:Supply and providing 250 mm 2 in one screw driver Taparia make or equivalent - |
| 73 | OD131650/2026-2027:Supply and providing 130 mm Neon line tester Taparia make or equivalent. - |
| 74 | OD131651/2026-2027:Supply and providing adjustable spanner 305 mm Taparia make or equivalent |
| 75 | OD354640/2025-2026:Aluminium anodised Danger Notice Board of size 150 x 100 mm. with inscriptions( both in English and Malayalam) and conventional Skull and Bone in Red colour. |
| 76 | OD133099/2026-2027:Supply and providing ABC 5 Kg Type type Fire Extinguisher with hose and clamps including fixing it to wall as required. |
| 77 | OD354621/2025-2026:Supply and providing 9 Liter capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. |
| 78 | OD354638/2025-2026:Supply of fuse puller up to 630 Amp |
| 79 | OD354627/2025-2026:Supply and providing First Aid Chart duly framed and placed in a conspicuouslocation for clear vision. |
| 80 | OD130108/2026-2027:Supply and providing 2mm thick Elastomeric fire retardant insulating sheet as per IS 15652/2006 to withstand 3.3 KV dielectric strength near panel/substation. |
| 81 | OD354643/2025-2026:Supply and fixing single phasing preventer SM 301 GIC/ L&T or equivalent and giving connections as required |
| 82 | OD21062/2026-2027:supply, Installation, testing and Commissioning of 3 HP Mono block Vacuum pump set KIRLOSKAR KV30 THREE PHASE 3HP (2.2KW) 11/4 X 11/4 MONO BLOCK or equivalent |
| 83 | 90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor |
| 84 | OD354647/2025-2026:Convey the dismantled panel, Cables etc from Departmental store to the site with out damage and installing the panel as per the instructions of departmental staff at site. |
| 85 | OD116363/2026-2027:Revamping of LT switch boards described as following, measured per square meter area of thefront face of panel :1.External cleaning, minor repairs etc. ,and sheet metal works as required.2.Panel Board repairs & Repair of hinges, minor sheet metal work etc.3.Replacing rubber beading as required.4.Panel board interior cleaning including repair of loose termination, bus bars, mountings etc.5.Renewal of perished fasteners, terminals etc.6.Trouble shooting the control the wiring including rectifications7.Renewal of Terminal sockets as required8.Insulation checks and correction of earthing9.Filling of un necessary holes in the panel board using suitable sheet metal work.10. Sealing the cable entry point using expandable PU Foam insulation sealant spray to safeguard from rats.10. Lettering and identification marking. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysSep 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender