Coal and Mines Boards / Undertakings / PSU Closing in 13 days TDR #57436832

Tender For Miscellaneous Electrical Upgradation Works As Per Boq At Jagannathpur Ocp, Bhatgaon Area

Issued by Boards / Undertakings / PSU · Surajpur, Chhattisgarh
Tender Value
34.69 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
13 days left
EMD
43400
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Surajpur → Chhattisgarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Miscellaneous Electrical Upgradation Works As Per Boq At Jagannathpur Ocp, Bhatgaon Area- 2 Providing And Installing A Restricted Neutral Groundingsystem For The Power Supply, Designed To Limit Theneutral Grounding Current To 10 Amps Using A Suitablyrated Neutral Grounding Resistor (Ngr) With Anappropriate Protection System, For 2 Nos. Of 4 Mva,33Kv/3.3Kv Oil-Cooled Transformers, In Accordancewith Cear 2023 Regulation 103(1) (Includingdismantling Of Existing Ngr) 3 Providing Proper Insulation For The Bare Conductors Inthe Incoming And Outgoing Connections Of The 4Mva, 33Kv/3.3Kv Transformers To Prevent Accidentalcontact And Ensure Operational Safety. (Bareconductor Shall Be Insulated By Required Heatshrinkable Tape/Tube).Length Of Conductor (Panther) = 210 M (210 M X 200Mm2 For One Transformer).Total Length Of Conductor For 02 Transformers Is 420M ( Panther Conductor) 4 Supply, Installation, Testing And Commissioning Of Onedc Undervoltage Relay Along With Ac Hotter Andassociated Wiring In The Battery Charger (A Dcunder-Voltage Rrlay Along With An Ac Hotter Shall Beinstalled In The Battery Charger At The Final Dc Outputterminals Going To The Dcdb, So That Whenever Dcoutput Fails Or Drops Below The Set Limit, An Audiblealarm Will Be Generated) (Compliance For Dc Fail Saferelay Protection Was Not Provided In The33Kv/3.3Kv Mine Substation) 5 Earthing Arrangement For All Lighting Arrester Outside Boundary Wall In Complete Respect 6 Supply And Installation Of Earthing Of 3Mtr. Long 40Mm Dia Gi Pipe With Pit Cover Etc 7 Supply And Laying Of 50X6Mm Gi Strip For Connection Of Earthing Pit . 8 Supply Installation Testing And Commissioning Of Interlocking System Between 3.3Kv Isolator (Ab Switch) And Their Corresponding Vcbs (Wire Required Will Be Provided By E&M Department Jocp)

BOQ

Name of Work:- WORKS AND SERVICES
Sl. No. Item Description
1Item Description/ Heading
2Providing and installing a restricted neutral groundingsystem for the power supply, designed to limit theneutral grounding current to 10 Amps using a suitablyrated Neutral Grounding Resistor (NGR) with anappropriate protection system, for 2 Nos. of 4 MVA,33kV/3.3kV oil-cooled transformers, in accordancewith CEAR 2023 Regulation 103(1) (Includingdismantling of existing NGR)
3Providing proper insulation for the bare conductors inthe incoming and outgoing connections of the 4MVA, 33kV/3.3kV transformers to prevent accidentalcontact and ensure operational safety. (Bareconductor shall be insulated by required heatshrinkable Tape/tube).Length of Conductor (Panther) = 210 M (210 M x 200MM2 for One Transformer).Total Length of Conductor for 02 Transformers is 420M ( Panther Conductor)
4Supply, Installation, Testing and Commissioning of oneDC undervoltage relay along with AC hotter andassociated wiring in the battery charger (A DCUnder-Voltage rRlay along with an AC hotter shall beinstalled in the battery charger at the final DC outputterminals going to the DCDB, so that whenever DCoutput fails or drops below the set limit, an audiblealarm will be generated) (Compliance for DC Fail SafeRelay Protection was not provided in the33KV/3.3KV mine Substation)
5Earthing arrangement for all lighting arrester Outside boundary wall in complete respect
6Supply and Installation of earthing of 3Mtr. long 40MM Dia GI Pipe with Pit Cover etc
7Supply and laying of 50x6mm GI strip for Connection of earthing pit .
8Supply installation testing and Commissioning of Interlocking system between 3.3KV Isolator (AB Switch) and their corresponding VCBs (Wire required will be provided by E&M Department JOCP)
9Supply of Trip Coil Assembly, 110V DC
10Supply of Auxiliary switch 3NO+3NC with crank and limit switch
11Supply of safety Lock (Keshar Lock)
12Wiring with ferrule, lugs & numbering inside the isolator panel box, welding, painting and erection including supply of materials
13Installation, testing & commissioning charges including making of steel enclosure with terminal lock & key other repairing work as per site requirement
14Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57436832
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 34.69 Lakhs
LAST DATE 24-09-2026
Authority
Authority Name South Eastern Coalfields Limited
Work Description Tender For Miscellaneous Electrical Upgradation Works As Per Boq At Jagannathpur Ocp, Bhatgaon Area- 2 Providing And Installing A Restricted Neutral Groundingsystem For The Power Supply, Designed To Limit Theneutral Grounding Current To 10 Amps Using A Suitablyrated Neutral Grounding Resistor (Ngr) With Anappropriate Protection System, For 2 Nos. Of 4 Mva,33Kv/3.3Kv Oil-Cooled Transformers, In Accordancewith Cear 2023 Regulation 103(1) (Includingdismantling Of Existing Ngr) 3 Providing Proper Insulation For The Bare Conductors Inthe Incoming And Outgoing Connections Of The 4Mva, 33Kv/3.3Kv Transformers To Prevent Accidentalcontact And Ensure Operational Safety. (Bareconductor Shall Be Insulated By Required Heatshrinkable Tape/Tube).Length Of Conductor (Panther) = 210 M (210 M X 200Mm2 For One Transformer).Total Length Of Conductor For 02 Transformers Is 420M ( Panther Conductor) 4 Supply, Installation, Testing And Commissioning Of Onedc Undervoltage Relay Along With Ac Hotter Andassociated Wiring In The Battery Charger (A Dcunder-Voltage Rrlay Along With An Ac Hotter Shall Beinstalled In The Battery Charger At The Final Dc Outputterminals Going To The Dcdb, So That Whenever Dcoutput Fails Or Drops Below The Set Limit, An Audiblealarm Will Be Generated) (Compliance For Dc Fail Saferelay Protection Was Not Provided In The33Kv/3.3Kv Mine Substation) 5 Earthing Arrangement For All Lighting Arrester Outside Boundary Wall In Complete Respect 6 Supply And Installation Of Earthing Of 3Mtr. Long 40Mm Dia Gi Pipe With Pit Cover Etc 7 Supply And Laying Of 50X6Mm Gi Strip For Connection Of Earthing Pit . 8 Supply Installation Testing And Commissioning Of Interlocking System Between 3.3Kv Isolator (Ab Switch) And Their Corresponding Vcbs (Wire Required Will Be Provided By E&M Department Jocp)
Basic Detail
Tender No SECL/Bhat/EM/e-open tender/26-27/17 dtd 09.09.2026
Bidding Type Tender
Location
City Surajpur
State Chhattisgarh
Key Dates
Publish Date 09 Sep 2026
Submission Date 24 Sep 2026
Open Date 25 Sep 2026
Finance
Tender Value 34.69 Lakhs
Tender Fee Ref. Documents
EMD 43400
Exemption Not Available
Document List
bf20eba6-fc83-497b-9a3f-1147ba868835.html
BOQ_378134.xls
Tendernotice_1 (26).pdf
Tendernotice_2 (4).pdf
Tendernotice_3 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Sep 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

bf20eba6-fc83-497b-9a3f-1147ba868835.html

xls

BOQ_378134.xls

pdf

Tendernotice_1 (26).pdf

pdf

Tendernotice_2 (4).pdf

pdf

Tendernotice_3 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders