Tender For Upgradation, Extension And Modernization Of The Existing Auditorium Of Mayailambi Dramatic Union, Thongkhong Laxmi Bazar, Yumnam Huidrom.
Tender Value
5.59 Crore
Estimated cost
Bid Submission
23 Sep 2026
13 days left
EMD
11.19 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Imphal West → Manipur
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Upgradation, Extension And Modernization Of The Existing Auditorium Of Mayailambi Dramatic Union, Thongkhong Laxmi Bazar, Yumnam Huidrom.
BOQ
| Sl. No. | Item Description |
| 1 | A - CONSTRUCTION OF MAIN BUILDING: |
| 2 | EARTH WORK: |
| 3 | Earth work in excavation by mechanical means (Hydraulic Excavator )/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1. 5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (a) All kinds of soil. |
| 4 | Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m |
| 5 | Supplying and filling in plinth with sandy soil under floors including, watering. Ramming consolidating and dressing complete. |
| 6 | CEMENT CONCRETE WORKS: |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level (a) 1:4:8 (1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size ) |
| 8 | (a) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size ) |
| 9 | Providing and laying damp-proof course 50mm thick with cement concrete 1 :2:4 {1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 10 | Extra for providing and mixing water proofing material in cement concrete work @1 kg per 50 kg of cement. |
| 11 | Applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7 kg per sqm on damp-proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in Kerosene oil. |
| 12 | Making plinth protection 50mm thick of cement concrete 1 :3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 13 | REINFORCED CEMENT CONCRETE WORKS: |
| 14 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. - All works upto Plinth level. (a) Concrete of M-25 grade with minimum cement content of 330 kg/cum. |
| 15 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. - All works above Plinth level upto floor V level. - Beam and Slab.(a) Concrete of M-25 grade with minimum cement content of 330 kg/cum. |
| 16 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. - All works above Plinth level upto floor V level. - Colomns. (a) Concrete of M-25 grade with minimum cement content of 330 kg/cum. |
| 17 | STEEL REINFORCEMENT: |
| 18 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. (a) Thermo-Mechanically Treated bars |
| 19 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Above plinth level. (a) Thermo-Mechanically Treated bars |
| 20 | FORM WORKS: |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete. |
| 22 | (b) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 23 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick. |
| 24 | (d) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12mm thick. |
| 25 | (e) Edges of slabs and breaks in floors and walls. (i) Under 20 cm wide |
| 26 | (f) Stairs, (excluding landings) except spiral-staircases. |
| 27 | BRICK WORKS: |
| 28 | Brick work with common burnt clay F.P.S. (non modular) bricks of class in foundation and plinth in : (a) Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 29 | Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in . (a) Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 30 | WOOD WORKS: |
| 31 | Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately) : (a) Local best quality Teak wood |
| 32 | Providing & fixing panelled or panelled and glazed shutters for doors, windows, clerestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (a) Local best quality Teak wood.(i) 35 mm thick shutters |
| 33 | 25mm wooden planking, tongued and grooved in flooring including fixing with iron screws complete with : (a) Ist class teak wood |
| 34 | 25 mm thick plank walling (Tolhao local best quality) and Tolhao wood beading 62mm x 12mm i/c fitting and fixing with necessary screws and nails complete (frame work to be paid separately). |
| 35 | Providing & fixing 25 mm thick plain local quality Uningthou skirting with necessary screws & priming coat on unexposed surface. |
| 36 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : (a) Local best quality Tolhao wood |
| 37 | Providing 40x5 mm. flat iron hold fast 40 cm. i/c fixing to frames with 10 mm. dia. Nuts & wooden plugs and embedding to cement concrete block 30x10x15 cm.1:3:6 mix (1 cement : 3 course sand : 6 stone agrt. 20 mm. nominal gauge) |
| 38 | Providing and fixing bright finished brass 100 mm door mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 39 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (a) 200 x 10mm |
| 40 | (b) 100 x 10mm |
| 41 | Providing & fixing ISI marked oxidised M.S. Sliding bolts with screws etc. Complete.(a) 250X16mm. |
| 42 | STEEL WORKS: |
| 43 | Steel work in built up tubular (round, square or recta ngular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. (a) Electric resistance or induction butt welded tubes. |
| 44 | P/F in position collapsible steel shutters with vertical channels 20mm × 10 mm × 2 mm & braced with flats iron diagonals 20 mm × 5 mm sizes with top & bottom rails of T iron 40mm × 40 mm × 6 mm with 38 mm dia steel pullets complete with bolts and nuts, looking arrangement, stoppers, handles i/c applying a priming coat of approved steel primer. |
| 45 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters. (a) 80 x 1.25mm M.S. laths with 1.25 mm thick top cover. |
| 46 | Extra for providing mechanical device chain and crank operation for operating rolling shutters. (a) Exceeding 16.80 sqm in area. |
| 47 | ROOFING & CEILING: |
| 48 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (a) 1.00mm thick with zinc coating not less than 275gm/m2 |
| 49 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. (a) 0.80mm thick with zinc coating not less than 275gm/m2 |
| 50 | 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS:2095 part I, of size 595 x 595 mm, having perforation of 9.7 x 9.2 mm at 19.4 mm c/c with center borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 51 | FLOORING: |
| 52 | 52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume hardening compound is mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 53 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. (a) Double charge vitrified tile polished finish of size (i) Size of Tile 600 x 600mm. |
| 54 | Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : |
| 55 | (a) Makrana white second quality. |
| 56 | Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. (a) Marble tiles (polished) Raj Nagar. 8 mm thick. |
| 57 | ALUMINIUM WORKS: |
| 58 | P/F aluminium works for doors, windows, ventilators and partitions with extruded built-up standard tubular sections/ appropriate Z- sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners i/c necessary filling up gaps at junctions, at top, bottom and side with required EPDM rubber/ Neoprene gasket etc. Aluminium snap beading for glazing/panelling, CP brass/stainless steel screws, all complete as per architectural drawing and the directions of Engineer -in-charge. (Glazing and panelling to be paid for separately). For shutters of doors, windows & ventilators i/c providing and fixing hinges/pivots and making provision for fixing of fitting wherever required i/c the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid separately). (a) Powder coated aluminium (minimum thickness of powder coating 50 micron). |
| 59 | P/F glazing in aluminium door, windows, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per architectural drawing and the directions of the engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) (a) With float glass panes of 5.50 mm thickness. |
| 60 | FINISHING: |
| 61 | 12mm cement plaster of mix :- (a) 1:4 ( 1 cement : 4 fine sand) |
| 62 | 15 mm cement plaster on rough side of single or half brick wall of mix : (a) 1:4 ( 1 cement : 4 fine sand) |
| 63 | 15 mm cement plaster 1 :3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall. |
| 64 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 65 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(i) Two or more coats on new work- |
| 66 | Applying one coat of water thinnable cement primer of approval brand and manufacture on wall surface: (a) Water thinnable cement primer. |
| 67 | Finishing walls with Acrylic Smooth exterior paint of required shade : (i) New work (Two or more coats applied @ 1.43 ltr/ 1 0 sqm. over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). |
| 68 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 69 | (a) Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 70 | Providing and applying two coats of fire retardant paint unthinned on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. |
| 71 | Applying priming coat: (a) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 72 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: (a) Two or more coats on new work |
| 73 | B - WATER SUPPLY & SANITARY INSTALLATION: |
| 74 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work- 50 mm nominal outer dia Pipes |
| 75 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.Internal work- 32mm nominal outer dia Pipes |
| 76 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. |
| 77 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 78 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass |
| 79 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 80 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 32 mm dia |
| 81 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 82 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. Pan |
| 83 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 84 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia |
| 85 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 86 | Providing and fixing toilet paper holder: C.P. brass |
| 87 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 88 | Providing and fixing PTMT liquid soapcontainer 109 mm wide, 125 mm high and112 mm distance from wall of standardshape with bracket of the same materialswith snap fittings of approved quality andcolour, weighing not less than 105 gms. |
| 89 | Providing and fixing mirror of superiorglass (of approved quality) and of requiredshape and size with plastic moulded frameof approved make and shade with 6 mmthick hard board backing : Rectangularshape 1500x450 mm |
| 90 | Providing and fixing P.V.C. waste pipe forsink or wash basin including P.V.C. wastefittings complete. Flexible pipe 32 mm dia |
| 91 | Providing and fixing UPVC soil, waste, rainwater and vent pipes including all requisitefittings, jointing of pipes & fittings withsolvent cement, trenching, refilling & testing of joints complete as per directionof Engineer in charge.(a).110mm dia |
| 92 | (b).75mm dia |
| 93 | Providing and fixing G.I. pipes completewith G.I. fittings and clamps, i/c cuttingand making good the walls etc.Internal work- Exposed on wall (a) 25 mm diameters |
| 94 | 32 mm diameter |
| 95 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cuttingand making good the walls etc.externalwork - Exposed on wall (a) 15 mm |
| 96 | (b) 20 mm |
| 97 | Making connection of G.I. distribution branch with G.I. main of following sizes byproviding and fixing tee, including cutting and threading the pipe etc.complete : 50 to80 mm nominal bore |
| 98 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to ISstandards and weighing not less than 810gms. 15 mm nominal bore |
| 99 | Providing and fixing C.P. brass stop cock(concealed) of standard design and ofapproved make conforming to IS:8931. : 15mm Nominal bore |
| 100 | Providing and fixing ball valve (brass) ofapproved quality, High or low pressure,with plastic floats complete :15 mm nominal bore |
| 101 | 25 mm nominal bore. |
| 102 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS :12701 marked, with cover and suitablelocking arrangement and making necessaryholes for inlet, outlet and overflow pipes butwithout fittings and the base support for tank. |
| 103 | Supply and fixing self priming single phase (TEXMO or similar brand ) of 1HP waterpump of approved quality |
| 104 | WATER RESERVOIR |
| 105 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (notexceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil asdirected, within a lead of 50 m. a) All kinds of soil. |
| 106 | Filling available excavated earth (excludingrock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to50 m and lift upto 1.5 m. |
| 107 | Providing and laying in position cementconcrete of specified grade excluding thecost of centering and shuttering - a) 1:4:8 (1Cement: 4 coarse sand : 8 graded stoneaggregate 40 mm nominal size) |
| 108 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: (a) 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm |
| 109 | Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a) 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 110 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1 :1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 111 | Centering and shuttering including strutting,propping etc. and removal of form for:(a) Foundations, footings, bases of columns,etc. for mass concrete. |
| 112 | (b) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12mm thick. |
| 113 | (c) Lintels, beams, plinth beams, girders,bressumers and cantilevers. |
| 114 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete up toplinth level.Thermo-Mechanically Treatedbars |
| 115 | Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level ina) Cement mortar 1 : 3 (1 cement : 3 coarse sand) |
| 116 | 12 mm cement plaster finished with a floating coat of neat cement of mix :1 :3 ( 1 cement : 3 fine sand) |
| 117 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.a),40mm thick with 20mm nominal size stone aggregate. |
| 118 | SEPTIC TANK |
| 119 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 120 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 121 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering --All work upto plinth level:a).1:4:8 (1 cement : 4 coarse sand :8 graded stone aggregate 40 mm nominal size) |
| 122 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering --All workupto plinth level:1:1.5:3 (1 cement:1.5 coarse sand:3 graded stone aggregate 20mm nominal size). |
| 123 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : (a).1:1.5:3 (1 Cement : 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size).Upto floor five level |
| 124 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete up toplinth level .a) Thermo-MechanicallyTreated bars. |
| 125 | Centering and shuttering including strutting,propping etc. and removal of form for:(a).Foundation, footing, bases of columnsetc. and mass concrete. |
| 126 | b).Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12mm thick. |
| 127 | c).Walls (any thickness) including attachedpilasters, buttresses, plinth and stringcourses etc. |
| 128 | Providing and fixing C.I. Cover frame (formanhole and chambers).a).600 mm x 450mm (heavy duty) |
| 129 | C - RCC DRAIN: |
| 130 | Earth Works: |
| 131 | Earth work in excavation by mechanical means (Hydraulic Excavator )/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1. 5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (a) All kinds of soil. |
| 132 | Cement Concrete Works: |
| 133 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level (a) 1:4:8 (1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size ) |
| 134 | RCC Works |
| 135 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: (a) 1:1.5:3 ( 1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 136 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. (a) Thermo-Mechanically Treated bars |
| 137 | Form Works |
| 138 | Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete. |
| 139 | (b) Walls (any thickness) including, attached pilasters, buttresses, plinth and, string courses etc. |
| 140 | D - ELECTRICAL WORKS: |
| 141 | Wiring for light/Fan point/Exhaust Fan point/Call bell point with 1.5mm²FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate,suitable G.I.box and earthing the point with 1.5mm² FRPVC insulated copper conductor single core cable etc.as required |
| 142 | 1. Group A |
| 143 | 2. Group B |
| 144 | 3. Group C |
| 145 | Suitable size GI box with modular plate and in front on surface or in recess i/c p/f 6 pin 16/15 amp modular socket outlet 15/16 amp modular switch, connection painting etc as required |
| 146 | s/f suitable size G.I box with modular plate and cover infront on surface or recess i/c p/f 3pin 5/6 amp modular socket outlet 5/6 amp modula |
| 147 | (1.7) Wiring for circuit/sub-main wiring along with earth wire with the (following size of ) FRPVC insulated copper conductor single core cable in surface/recessed steel conduit etc. as reqd. |
| 148 | 1. 2x1.5mm2 + 1x1.5mm2 earth wire. |
| 149 | 2. 2x2.5mm2 + 1x2.5mm2 earth wire. |
| 150 | 3. 2x4mm2 + 1x4mm2 earth wire. |
| 151 | 4. 2x6mm2 + 1x6mm2 earth wire. |
| 152 | 5. 2x10mm2 + 1x10mm2 earth wire. |
| 153 | S/F (following way) single pole and neutral, sheet steel MCCB DB 240v on surface/recessed complete with tinned copper busbar, neutral busbar, earthbar, dinbar, hinged front acrylie cover for the MCCB knobs datacable grand plate, enter connection, phosphatised and power painted including earthing etc. as required (but without MCB/RCCB/isolator) 2+4 Way |
| 154 | P/F8 way, (2+8 way) single door single pole and neutral, prewired, sheet steel MCB distribution board, 240V on surface / recessed complete with loose wire box, terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnection, including poweder coatede painting, earthing etc. as reqd. (but without MCB/RCCB/Isolator). |
| 155 | P/F 12 way, (2+12way) single door single pole and neutral, prewired, sheet steel MCB distribution board, 240V on surface / recessed complete with loose wire box, terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnection, including poweder coatede painting, earthing etc. as reqd. (but without MCB/RCCB/Isolator). |
| 156 | S/F 5amp to 32amp rating 230V “B” series for lighting and other purposes , load of (following poles) in the existing MCB DB complete with connection, testingand commissioning etc. as required.Single pole and neutral |
| 157 | S/F (following rating) double pole 240V isolator in the existing MCB DB complete with connection testing and commissioning as required. |
| 158 | 40 Amp |
| 159 | 63 Amp |
| 160 | S/F CFL bulk head luminaries deep down annodised Al. body, heat resistant primatic glass cover. (Ref 021240, BJBE-19, S-type CFL 1x9W). |
| 161 | Fabrication of control panel board by 16 gauge steel sheet, along with components mounting, making strip wiring auxiliary components, wiring all over the panel i/c fixing charge, painting etc. as reqd. |
| 162 | Indicating Lamp |
| 163 | Voltmeter range 0-500 volts. |
| 164 | Ammeter range 0-200 volts. |
| 165 | Current transformer coil range 0-200 amp. |
| 166 | Hinges for panel door |
| 167 | Panel door locks. |
| 168 | Selector switch for ammeter & voltmeter. |
| 169 | P/F (following capacity TP&N) dis-connector fuse switch unit inside the exiting cubicle panel board with I.S.I mark HRC fuses i/c drilling holes in the cubicle panel board making connection as reqd. |
| 170 | 400 Amp TP&N |
| 171 | 200 AmP TP&N |
| 172 | P/F 400Amp TPN stand ground on load on load change own switch (compact design) 415/500v including connection to as required |
| 173 | S/F Bus bar chamber with 4strips copper busbar of length 600mm suitable for 200amps capacity complete with all accessories i/c connection earthing the body as required. |
| 174 | S/F 48” sweep (1200mm)a.c ceiling fan complete with down rod, canopy, 3 Blades but without regulator etc. as reqd. (Havells or similar 5 star) |
| 175 | 305mm sweep exhaust fan complete with all accessories connection etc as required |
| 176 | S/F stepped type electronic fan regulator on the modular plate switch box i/c connection but excluding modular plate as reqd.\ |
| 177 | S/F brass batten holder i/c connection etc. as reqd. |
| 178 | LED white lamp 18w |
| 179 | S/F 1,5 ton capacity split type air conditioner(Voltas/Hitachi, 3star) |
| 180 | S/F 25 amp Air conditioner power plug point i/c 4modules metal box on surface or in recess 4 module cover plate and cover in front 25 amp moduler starter 25 amp moduler socket outlet and 25 amp plug i/c connection etc as reqd. |
| 181 | S/F recess mounting LED down lighter BGSL 0301WH 220225 Cast alluminium housing fixed with collinated lens 3x1W white lens mounted on MCPCB extruded alluminium heat sink , spring loaded mounting clips ,complete with connection etc as reqd. |
| 182 | P/F lighting conductor finial made of 25mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper plate i/c holes etc. Complete as reqd |
| 183 | P/F copper tape in horizontal run p/f copper tape 2ommx3mm thick on parapet or surface of wall for lightning conductor as reqd(for horizontal run) |
| 184 | p/f copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd(for vertical run) |
| 185 | Earthing with copper earth plate 600 mmx 600mmx6mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) as reqd. |
| 186 | Extra for using Salt & Charcoal for copper plate with electrode as reqd. |
| 187 | Earth connection from earth electrod with 4mm dia in 15mm GI pipe as required |
| 188 | P/F earth bus of 25mmx5mm copper strip on surface or in recessed for connection etc. as reqd. |
| 189 | SITC of 125 KVA 3 phase CPCB+IV DG Set. |
| 190 | Supply,Testing and commisioning of wall Mounted Secondary R.O Plant of 50LPH capable to deliver Output Water at TDS 150PPM for LABS,System to include all Valves, switches, sockets, pipes, reject watermanagement,connections and accessories to make the system comple and functioning. |
| 191 | Supplying,installation,testingandcommisioningofwaterpump,allfittingscomplete. |
| 192 | (18) 9m long steel tubuler pole (410 SP-14) |
| 193 | Erection of steel tubular pole of length not less than 8m but not exceeding 10ms in cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 40mm nominal size) foundation i/c excation and refiling etc as required. |
| 194 | Wiring for circuit/ submain wiring along with earth wire with the (following size of) FRPVC insulated copper conductor single core cable in surface/recessed steel conduit etc as reqd. 2x2.5mm²+ 2.5mm² Earth wire |
| 195 | S/F2.5 m long G.I bracket and pipe for fixing street lamp and lamp post. |
| 196 | Providing of 10mm2 2-core PVC/XLPE insulated heavy duty armoured cable 1.1KV grade. |
| 197 | Laying of 1 no. PVC insulated PVC sheathed power cable of 1.1KV grade of size not less than 25mm2 but not exceeding 120mm2 direct in ground i/c excavation, sand cushioning, protective covering and re-filling the trench etc. as reqd. |
| 198 | S/F (6 X 10) hensen box including fixing etc. as reqd. |
| 199 | S/F 5amp to 32 amp rating 230 V \\"B\\" series for lighting and other purposes, load of (following poles)in the existing MCB DB complete with connection, testing and commissioning etc as required. (i) Single pole and neutral |
| 200 | Fabrication of control panel board by 16 gauge steel sheet, along with components mounting, making strip wiring auxiliary components, wiring all over the panel i/c fixing charge, painting etc. as reqd. |
| 201 | Indicating Lamp |
| 202 | Voltmeter range 0-500 volts. |
| 203 | Ammeter range 0-200 volts. |
| 204 | Current transformer coil range 0-200 amp. |
| 205 | Hinges for panel door |
| 206 | Panel door locks. |
| 207 | Selector switch for ammeter & voltmeter. |
| 208 | S/F Programmable Timer |
| 209 | Providing and fixing 100 amp. 10 KA MCCB in existing cubicle panel board including drilling holes in cubicle panel & making connection as reqd. |
| 210 | P/F 50w street Lamp (Panasonic,Bajaj or Philips) |
| 211 | E - FIRE FIGHTING WORKS: |
| 212 | Providing, laying, testing & Commissioning of C Class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding fitting,like elbow, tees, flances, tapers, nut bolts, gasket etc. and fixing the pipe on the wall/ceiling with suitatble clamp / support frame and painting with two or more coat of synthetic enamel paint of required shade complete as required |
| 213 | (a) 200 MM dia |
| 214 | (b) 150 MM dia |
| 215 | ( c) 100 MM dia |
| 216 | (d) 80 MM dia |
| 217 | (e) 50 MM dia |
| 218 | (f) 40 MM dia |
| 219 | (g) 25 MM dia |
| 220 | Providing ,fixing ,testing & commissioning of 15 mm dia quartzoid bulb type sprinkler of rating 68 degree centigrade with required accessories Pendent sprinkler |
| 221 | Supplying and fixing of 63mm dia 15 m long RRL hose pipe with 63mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required. - Gun Metal |
| 222 | Supplying & fixing of 63 mm dia gun metal short branch pipe with 20mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required. - Gun metal |
| 223 | Supplying and fixing single headed internal hydrant valve with instantaneoues Gunmetal / stailess steel couplingof 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type - A) with blank Gunmetal / Stailess Steel cap and chain as required. - Single headed Gunmetal. |
| 224 | Supplying and fixing single headed external yard hydrant valve with 1 no. 63 mm dia. instantaneoues FM Gunmetal / stailess steel coupling and cast iron wheel ISI marked conforming to IS 5290 (Type - A) with blank Gunmetal / Stailess Steel cap and chain as required. - Single headed Gunmetal. |
| 225 | Supplying and fixing first-aid Swiming Hose reel drum with MS contruction spray painted in post office red, conforming to IS 884 complete with the following as required. 20mm nomonal internal dia water hose theroplastic (textile reinforced) type-2 as per IS 12585. 20mm nominal internal dia gun metal glove valve & nozzle. Drum and brackets for fixing the equipments on wall. Connections from riser with 25mm dia stop gun metal valve & M.S. pipe and socket. |
| 226 | Supply of Double door Glass fronted hose box cabinet suitable for Two hoses and one branch pipe nozzle, with locking arrangement painted red outside and white inside Please Enable Macros to View BoQ information |
| 227 | Supply of Double door Glass fronted hose box cabinet suitable for Two hoses and one branch pipe nozzle, with locking arrangement painted red outside and white inside Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysSep 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender